Objective: To study the postoperative evolution of corneal astigmatism following phaco-alternative at the University Hospital Center of Ouémé-Plateau (UHC-OP) in Porto-Novo. Method: This was a prospective, c...Objective: To study the postoperative evolution of corneal astigmatism following phaco-alternative at the University Hospital Center of Ouémé-Plateau (UHC-OP) in Porto-Novo. Method: This was a prospective, cross-sectional study with a descriptive and analytical purpose conducted from April 19 to September 20, 2021;a period of 6 months. The study included all patients presenting with senile or non-senile cataracts without a history of corneal trauma and who underwent phaco-alternative during the study period. Results: A total of 62 eyes underwent phaco-alternative. The average age was 63 ± 12 years with a male predominance of 59.7%. Phaco-alternative was performed with 74.2% linear incision and 25.8% smile incision. Perioperative incidents were mainly capsular ruptures with vitreous loss occurring in 8.1% of cases. The mean preoperative astigmatism was 1.29 ± 1.5 D with an axis of 180˚ ± 20˚, indicating with-the-rule astigmatism. The mean postoperative astigmatism was 2.2 ± 1.5 D with an axis of 90˚ ± 20˚, indicating against-the-rule astigmatism. The mean induced astigmatism at Day 30 was 1.4 ± 1.2 D for smile incision and 1.8 ± 1.2 D for linear incision. Conclusion: Phaco-alternative yields good results with few complications but remains astigmatogenic. The smile incision appears to be less astigmatogenic.展开更多
AIM:To evaluate the effect of low-degree astigmatism on objective visual quality through the Optical Quality Analysis System(OQAS).METHODS:This study enrolled 46 participants(aged 23 to 30y,90 eyes)with normal or corr...AIM:To evaluate the effect of low-degree astigmatism on objective visual quality through the Optical Quality Analysis System(OQAS).METHODS:This study enrolled 46 participants(aged 23 to 30y,90 eyes)with normal or corrected-to-normal vision.The cylindrical lenses(0,0.5,0.75,1.0,and 1.25 D)were placed at the axial direction(180°,45°,90°,and 135°)in front of the eyes with the best correction to form 16 types of regular low-degree astigmatism.OQAS was used to detect the objective visual quality,recorded as the objective scattering index(OSI),OQAS values at contrasts of 100%,20%,and 9%predictive visual acuity(OV100%,OV20%,and OV9%),modulation transfer function cut-off(MTFcut-off)and Strehl ratio(SR).The mixed effect linear model was used to compare objective visual quality differences between groups and examine associations between astigmatic magnitude and objective visual quality parameters.RESULTS:Apparent negative relationships between the magnitude of low astigmatism and objective visual quality were observed.The increase of OSI per degree of astigmatism at 180°,45°,90°,and 135°axis were 0.38(95%CI:0.35,0.42),0.50(95%CI:0.46,0.53),0.49(95%CI:0.45,0.54)and 0.37(95%CI:0.34,0.41),respectively.The decrease of MTFcut-off per degree of astigmatism at 180°,45°,90°,and 135°axis were-10.30(95%CI:-11.43,-9.16),-12.73(95%CI:-13.62,-11.86),-12.75(95%CI:-13.79,-11.70),and-9.97(95%CI:-10.92,-9.03),respectively.At the same astigmatism degree,OSI at 45°and 90°axis were higher than that at 0°and 135°axis,while MTFcut-off were lower.CONCLUSION:Low astigmatism of only 0.50 D can significantly reduce the objective visual quality.展开更多
Among refractive errors,astigmatism is the most common optical aberration,where refraction changes in different meridians of the eye.It causes blurred vision at any distance and includes corneal,lenticular,and retinal...Among refractive errors,astigmatism is the most common optical aberration,where refraction changes in different meridians of the eye.It causes blurred vision at any distance and includes corneal,lenticular,and retinal astigmatism.Cataract surgery used to cause a progressive increase in the pre-exisiting corneal astigmatism because of creating a surgically induced astigmatism,for example,a large size surgery incision.The development of surgical techniques during last decades has made cataract surgery interchange to treat preoperative corneal astigmatism at time of surgery.Nowadays,three surgical approaches can be used.By placing a sutureless clear corneal incision on the steep meridian of the cornea,a preoperative corneal astigmatism less than 1.0 D can be corrected.Single or paired peripheral corneal relaxing incisions(PCRIs)provide 1.0-3.0 D corneal astigmatism correction.PCRIs are typically used for treating 1.0-1.5 D of regular corneal astigmatism,if more than 2.0 D,the risk of overcorrection and irregular astigmatism is increased.When toric intraocular lenses(IOLs)are unavailable in markets,PCRIs are still a reasonable option for patients with up to 3.0 D of pre-existing corneal astigmatism.Toric IOLs implantation can correct 1.0-4.5 D of corneal astigmatism.Several IOLs are approved to correct a high degree of corneal astigmatism with cylinder power up to 12.0 D.These approaches can be used alone or in combination.展开更多
Objective:To explore the corrective effect of posterior chamber intraocular lens implantation with phakic eyes in the treatment of high myopia and astigmatism.Methods:From May 2023,the hospital began to collect the ca...Objective:To explore the corrective effect of posterior chamber intraocular lens implantation with phakic eyes in the treatment of high myopia and astigmatism.Methods:From May 2023,the hospital began to collect the case data of diagnosis and treatment of high myopia and astigmatism.By May 2024,310 cases were included,all of which were treated with posterior chamber intraocular lens implantation.The visual acuity,astigmatism and axial position of the intraocular lens were observed before and after treatment.Results:At different time points after the operation,the patient’s vision was significantly improved compared with that before the operation(P<0.05),and the vision level was equal to or greater than the best-corrected vision before the operation.At different time points after the operation,the average rotation of the intraocular lens was less than 5 degrees.Astigmatism was significantly lower than that before the operation(P<0.05).After the operation,the intraocular pressure increased in 11 cases,accounting for 3.55%,with no adverse complications such as lens turbidity,glare and obvious halo occurring.Conclusion:The posterior chamber intraocular lens implantation with phakic eyes has an ideal correction effect in the treatment of high myopia and astigmatism,which can effectively improve the vision level of patients and reduce the degree of astigmatism,and has high effectiveness and safety.展开更多
AIM:To evaluate the effect of symmetrical arc incision correcting corneal astigmatism in femtosecond laserassisted phacoemulsification(FLACS).METHODS:This study enrolled patients with cataract combined with regular co...AIM:To evaluate the effect of symmetrical arc incision correcting corneal astigmatism in femtosecond laserassisted phacoemulsification(FLACS).METHODS:This study enrolled patients with cataract combined with regular corneal astigmatism of>0.75 D,who underwent FLACS.Symmetrical arc incision was set at 8 mm diameter and 85%depth.The follow-up time was 3-24mo(4.92±3.49mo).Pentacam recorded the corneal astigmatism and higher-order aberration at pre-operation and post-operation.The changes in corneal astigmatism were analyzed by Alpins method.The correlation of astigmatism type,age,corneal horizontal diameter,corneal thickness,arc incision length,and correction index(CI)was analyzed,and the residual corneal astigmatism was compared with the residual whole eye astigmatism.RESULTS:Totally 79 patients(102 eyes)were enrolled,10 patients had corneal epithelial injury,1 patient occurred corneal epithelial hyperplasia.The corneal astigmatism was 1.23±0.38 D pre-operation,and decreased to 0.76±0.39 D post-operation(t=10.146,P=0.000).Corneal high-order aberration was 0.17±0.08μm pre-operation and 0.24±0.11μm post-operation(t=-5.186,P=0.000).The residual corneal astigmatism and residual whole eye astigmatism were no significant difference(t=-0.347,P=0.729).Using Alpin’s method,the following were determined:target-induced astigmatism(TIA)=1.23±0.38 D,surgeryinduced astigmatism(SIA)=0.77±0.45 D,difference vector(DV)=0.77±0.39 D,and CI=0.54±0.28.Age,astigmatism size,corneal horizontal diameter,corneal thickness,and arc incision length were not correlated with CI.The CI for against the rule astigmatism(ATR)was better than that for with the rule astigmatism(WTR;P=0.001).CONCLUSION:Femtosecond laser-assisted astigmatic keratotomy has better CI of ATR,but increase higher-order corneal aberration.CI is not ideal,it’s not a perfect choice if we pursue ideal correction effect.展开更多
Significance: So far, many scholars have studied the astigmatism caused by glaucoma surgery, but they cannot provide enough useful help for the clinic. When a patient has glaucoma, cataracts and irregular astigmatism ...Significance: So far, many scholars have studied the astigmatism caused by glaucoma surgery, but they cannot provide enough useful help for the clinic. When a patient has glaucoma, cataracts and irregular astigmatism at the same time, it is often difficult to achieve satisfactory results. Purpose: This study intends to describe a case of a patient with glaucoma, irregular astigmatism, and cataract who was successfully treated. Additionally, it can serve as a useful source of inspiration for the future care of patients like this. Case Presentation: A 24-year-old male with keratoconus in the past. He had undergone a corneal crosslinking operation in the right eye and a penetrating keratoplasty in the left eye due to his long history of keratoconus in both eyes. Right now, the keratoconus in that eye is stable. Unfortunately, he has now been diagnosed with open-angle glaucoma and complicated cataracts in both eyes, and he was admitted to our hospital for surgery. The right eye had significant irregular astigmatism, which was discovered during the preoperative assessment, and the implantation of a Toric intraocular lens was unable to produce good results. Finally, we chose to perform EXPRESS glaucoma drainage device implantation + phacoemulsification + intraocular lense (ZEISS CT ASPHINA 409MP) implantation. The patient had stable postoperative astigmatism with rule thanks to the traction effect of the scleral flap suture. Astigmatism was typically stable six months after surgery, and the corrected visual acuity with glasses had improved to 20/25. Conclusion: This patient suffers from cataracts, keratoconus, glaucoma, and irregular astigmatism. Due to the interconnectedness of these four disorders, simultaneous success is challenging. We realized that surgically induced astigmatism, frequently affects vision early after filtering surgery for glaucoma patients. In the instance of this patient, we tightly sutured the scleral flap and using tractive action, established regular astigmatism. After the patient’s astigmatism stabilized, optometry was given to correct the vision. This technique should result in much better visual acuity. Finally, it came to pass.展开更多
AIM:To assess the visual correction of patients with different degrees of astigmatism with toric soft contact lenses(TSC).METHODS:It was a real-world study with prospective and single-arm design.A total of 384 patient...AIM:To assess the visual correction of patients with different degrees of astigmatism with toric soft contact lenses(TSC).METHODS:It was a real-world study with prospective and single-arm design.A total of 384 patients with astigmatism who came for TSC fitting and alignment from November 2022 to January 2023 were included.According to the difference in astigmatism,patients were divided into groups A(cylinder degree:-0.75 to-0.50 D),B(cylinder degree:-1.75 to-1.00 D)and C(cylinder degree≤-2.00 D),and followed up on the day of wear,1wk,1 and 3mo,mainly to observe visual acuity,refraction,lens fit,visual quality and comfort at 1wk after wear.The visual acuity success rate and the overall success rate of the fitting were evaluation indicators(taking into account the four dimensions of visual acuity,fitting,quality of vision and comfort).The visual acuity success rate was calculated by taking“corrected visual acuity with contact lenses is no less than 1 line or better than best spectacle-corrected visual acuity”(i.e.corrected visual acuity with contact lenses is 1 line below,equal to,one line above or more than best spectaclecorrected visual acuity)as the criterion for visual success,and the the overall success rate of the fitting was calculated by using the comprehensive indicators(visual acuity,fit,visual quality,comfort)to meet certain conditions as the judgment criteria for successful fitting.RESULTS:After 1wk of wearing TSC,the visual acuity success rates of patients were 100%(207/207),98.58%(139/141)and 97.22%(35/36)in the three groups,respectively,with residual cylinder closed to 0.The acceptability of the lens fitting was over 95%;the incidence of adverse visual symptoms was within 10%and the comfort acceptability was over 97%.The overall success rate of fitting for patients with high,medium and low astigmatism was 93.72%(194/207),90.78%(128/141)and 88.89%(32/36),respectively.CONCLUSION:TSC(model:G&G POP·CT)are effective in correcting astigmatism in patients with different degrees of astigmatism.展开更多
AIM: To evaluate corneal astigmatism after phacoemulsification using 2.2 mm or 1.8 mm clear corneal micro-incisions and its effects on visual function.METHODS: Sixty cases (60 eyes) with cataract were randomly div...AIM: To evaluate corneal astigmatism after phacoemulsification using 2.2 mm or 1.8 mm clear corneal micro-incisions and its effects on visual function.METHODS: Sixty cases (60 eyes) with cataract were randomly divided into groups A (n=30) and B (n=30) respectively underwent 2.2 mm and 1.8 mm clear corneal tunnel incision phacoemulsification combined with folding intraocular lens implantation from the time direction of 11:00. On day 1 and at 1, 4, and 6wk after operation, patients’ vision was measured and both the corneal curvature and corneal thickness (CT) were recorded using Pentacam.RESULTS: The measured surgery-induced astigmatism (SIA) in both groups A and B peaked on day 1 after operation, and then gradually decreased and eventually stabilized in week 4. No statistically significant difference was found in corneal astigmatism between two groups (P〉0.05). The measured corneal astigmatism at 4wk and 6wk postoperatively were 0.28±0.09 D and 0.27±0.10 D for groups A and 0.27±0.09 D and 0.25±0.10 D for groups B without statistically significant difference (P〉0.05). In addition, no significant differences in visual acuity and CT were found between groups A and B before or after operation.CONCLUSION: Both 2.2 mm and 1.8 mm micro-incision cataract surgeries result in relatively small SIA with no difference in visual function and corneal astigmatism between two surgery approaches. Thus, the two types of surgical systems are safe and efficient for cataract treatment, by which satisfactory uncorrected visual acuity can be regained early postoperatively.展开更多
AIM: To assess the visual outcomes and possible risk factors associated with axis alignment and rotational stability after implantation of Toric implantable collamer lens (TICL) for the correction of high myopic astig...AIM: To assess the visual outcomes and possible risk factors associated with axis alignment and rotational stability after implantation of Toric implantable collamer lens (TICL) for the correction of high myopic astigmatism. METHODS: In this prospective, nonrandomized clinical study, 54 consecutive eyes of 29 patients with high myopic astigmatism received TICL implantation. To evaluate postoperative axis deviation from the intended axis, a digital anterior segment photograph was taken. The ultrasound biomicroscopy(UBM) was used to observe footplate-position. RESULTS: After mean follow-up of 8.6 months, mean manifest refractive cylinder (MRC) decreased 79.3% from (-1.88 +/- 1.49)D preoperatively to (0.39 +/- 0.61)D postoperatively. MRC within 1.00D occurred in 68.5% (37/54) of eyes, whereas 48.1% (26/54) had MRC within 0.50D. Mean manifest refraction spherical equivalent (MRSE) changed from (-1208 +/- 422)D preoperatively to (-0.41 +/- 0.61)D postoperatively. Uncorrected binocular vision of 20/20 or better occurred in 72.2% (39/54) of patients compared with binocular best-corrected visual acuity (BCVA) of 20/20 or better in 44.4% (24/54) preoperatively. The mean difference between intended and achieved TICL axes was (6.96 +/- 8.37)degrees. Footplates of TICLs were in the ciliary sulcus in 22 eyes (46.3%), below the ciliary sulcus in 32 eyes (53.7%). The angle of TICL rotation had significant correlation with the footplates-position (t = 2.127; P=0.045) and the postoperative TICL vaulting (r=-0.516; P=0.000). CONCLUSION: The results of our study further support the safety, efficacy and predictability of TICL for the correct high myopic astigmatism. The footplate-position of TICL and vault value should be taken into consideration as two possible risks factors for TICL rotation.展开更多
AIM: To investigate the influence of astigmatism on visual acuity in school-aged children, and to define a cutoff for clinically significant astigmatism. METHODS: This is a population-based, cross-sectional study. A...AIM: To investigate the influence of astigmatism on visual acuity in school-aged children, and to define a cutoff for clinically significant astigmatism. METHODS: This is a population-based, cross-sectional study. Among 5053 enumerated children aged 5-15 y in Guangzhou, 3729(73.8%) children aged 7-15 with successful cycloplegic auto-refraction(1% cyclopentolate) and a reliable visual acuity measurement were included. Ocular measurement included external eye, anterior segment, media and fundus and cycloplegic auto-refraction. Primary outcome measures included the relationship between severity and subtypes of astigmatism and the prevalence of visual impairment. Three criteria for visual impairment were adopted: best-corrected visual acuity(BCVA) ≤0.7, uncorrected visual acuity(UCVA) ≤0.5 or 〈0.7 in the right eye.RESULTS: Increases of cylinder power was significantly associated with worse visual acuity(UCVA: β=0.051, P〈0.01; BCVA: β=0.025, P〈0.001). A substantial increase in UCVI and BCVI was seen with astigmatism of 1.00 diopter(D) or more. Astigmatism ≥1.00 D had a greater BCVI prevalence than cylinder power less than 1.00 D(OR=4.20, 95%CI: 3.08-5.74), and this was also true for hyperopic, emmetropic and myopic refraction categories. Oblique astigmatism was associated with a higher risk of BCVI relative to with the rule astigmatism in myopic refractive category(OR=12.87, 95%CI: 2.20-75.38).CONCLUSION: Both magnitude and subtypes of astigmatism influence the prevalence of visual impairment in school children. Cylinder ≥1.00 D may be useful as a cutoff for clinically significant astigmatism.展开更多
· AIM: To evaluate and compare aspheric toric intraocular lens(IOL) implantation and aspheric monofocal IOL implantation with limbal relaxing incisions(LRI) to manage low corneal astigmatism(1.0-2.0 D) in catarac...· AIM: To evaluate and compare aspheric toric intraocular lens(IOL) implantation and aspheric monofocal IOL implantation with limbal relaxing incisions(LRI) to manage low corneal astigmatism(1.0-2.0 D) in cataract surgery.· METHODS: A prospective randomized comparative clinical study was performed. There were randomly recruited 102 eyes(102 patients) with cataracts associated with corneal astigmatism and divided into two groups. The first group received toric IOL implantation and the second one monofocal IOL implantation with peripheral corneal relaxing incisions. Outcomes considered were: visual acuity, postoperative residual astigmatism, endothelial cell count, the need for spectacles, and patient satisfaction. To determine the postoperative toric axis, all patients who underwent the toric IOL implantation were further evaluated using an OPD Scan III(Nidek Co, Japan). Follow-up lasted 6mo.· RESULTS: The mean uncorrected distance visual acuity(UCVA) and the best corrected visual acuity(BCVA) demonstrated statistically significant improvement after surgery in both groups. At the end of the follow-up the UCVA was statistically better in the patients with toric IOL implants compared to those patients who underwent implantation of monofocal IOL plus LRI. The mean residual refractive astigmatism was of 0.4 D for the toric IOL group and 1.1 D for the LRI group(P 【0.01). No difference was observed in the postoperative endothelial cell count between the two groups.· CONCLUSION: The two surgical procedures demonstrated a significant decrease in refractive astigmatism. Toric IOL implantation was more effective and predictable compared to the limbal relaxing incision.展开更多
AIM: To determine the difference of surgical induced astigmatism between conventional 20-gauge sutured vitrectomy and 23-gauge transconjunctival sutureless vitrectomy, and the influence of corneal pachymetry and intra...AIM: To determine the difference of surgical induced astigmatism between conventional 20-gauge sutured vitrectomy and 23-gauge transconjunctival sutureless vitrectomy, and the influence of corneal pachymetry and intraocular pressure(IOP) on surgical induced astigmatism in diabetic patients.METHODS: This retrospective, consecutive case series consisted of 40 eyes of 38 diabetic subjects who underwent either 20-gauge or 23-gauge vitrectomy. The corneal curvature and thickness were measured with Scheimpflug imaging before surgery and 1wk; 1, 3mo after surgery. We compared the surgical induced astigmatism(SIA) on the true net power in 23-gauge group with that in 20-gauge group. We determined the correlation between corneal thickness change ratio, IOP and SIA measured by Pentacam. RESULTS: The mean SIAs were 1.082 ±0.085 D( mean ± SEM), 0.689 ±0.070 D and 0.459 ±0.063 D at postoperative 1wk; 1, 3mo respectively in diabetic subjects. The vitrectomy induced astigmatisms were declined significantly with time(F2,36=33.629, P =0.000)postoperatively. The 23-gauge surgery group induced significantly less astigmatism than 20-gauge surgery group(F1,37=11.046, P =0.020). Corneal thickness in diabetes elevated after surgery(F3,78=10.532, P =0.000).The linear regression analysis at postoperatively 1wk went as: SIA =-4.519 +4.931 change ratio(Port3) +0.026IOP(R2=0.46, P =0.000), whereas the rate of cornealthickness change and IOP showed no correlation with the change of astigmatism at postoperatively 1 and 3mo.CONCLUSION: There are significant serial changes in both 20-gauge and 23-gauge group in diabetic subjects.23-gauge induce less astigmatism than 20-gauge and become stable more rapidly than 20-gauge. The elevation of corneal thickness and IOP was associated with increased astigmatim at the early postoperative stage both in 23-gauge and 20-gauge surgery group.展开更多
AIM: To explore the effect of the posterior astigmatism on total corneal astigmatism and evaluate the error caused by substituting the corneal astigmatism of the simulated keratometriy (simulated K) for the total c...AIM: To explore the effect of the posterior astigmatism on total corneal astigmatism and evaluate the error caused by substituting the corneal astigmatism of the simulated keratometriy (simulated K) for the total corneal astigmatism in age-related cataract patients. METHODS: A total of 211 eyes with age-related cataract from 164 patients (mean age: 66.8±9.0y, range: 45-83y) were examined using a multi-colored spot reflection topographer, and the total corneal astigmatism was measured. The power vector components J0 and J45 were analyzed. Correlations between the magnitude difference of the simulated K and total cornea astigmatism (magnitude differenceSimK-Tca), anterior J0, and absolute meridian difference (AMD) between the anterior and posterior astigmatisms were calculated. To compare the astigmatism of the simulated K and total cornea both in magnitude and axial orientation, we drew double-angle plots and calculated the vector difference between the two measures using vector analysis. A corrective regression formula was used to adjust the magnitude of the simulated K astigmatism to approach that of the total cornea. RESULTS: The magnitude differenceSimK-Tca was positively correlated with the anterior corneal J0 (Spearman’s rho= 0.539; P〈0.001) and negatively correlated with the AMDR (Spearman’s rho=-0.875, P〈0.001). When the anterior J0 value was larger than 1.3 D or smaller than -0.8 D, the errors caused by determining the total corneal astigmatism with the karatometric calculation tended to be greater than 0.25 D. An underestimation by 16% was observed for against the rule (ATR) astigmatism and an overestimation by 9% was observed for with the rule (WTR) astigmatism when ignoring the posterior measurements. CONCLUSION: Posterior corneal astigmatism should be valued for more precise corneal astigmatism management, especially for higher ATR astigmatism of the anterior corneal surface. We suggest a 9% reduction in the magnitude of the simulated K in eyes with WTR astigmatism, and a 16% addition of the magnitude of the simulated K in eyes with ATR astigmatism.展开更多
AIM: To study the impact of scleral flap position, under which the posterior chamber intraocular lenses (PC-IOL) were sulcus-fixed by trans-scleral suture, on cornea astigmatism. METHODS: Twenty-six aphakic or catarac...AIM: To study the impact of scleral flap position, under which the posterior chamber intraocular lenses (PC-IOL) were sulcus-fixed by trans-scleral suture, on cornea astigmatism. METHODS: Twenty-six aphakic or cataract eyes were comprised in this prospective noncomparative case series study. Eleven eyes had traumatic cataract removed without sufficient capsular support, 3 had blunt trauma with subluxated traumatic cataract, 8 had undergone vitreoretinal surgery and 4 had congenital cataract removed. The average age was 54 years (range 21-74 years), with 17 men and 7 women. The foldable PC-IOL was fixed in sulcus by trans-scleral suture. The incision for IOL implantation was made 1mm posterior to limbus along the steepest meridian of cornea, while scleral flaps to bury the knots of trans-scleral suture were made along the flattest meridian. All the surgeries were performed by a single doctor (Ma L), and the follow up was at least 13 months (range 13-28 months). The preoperative, 3 months and 1 year postoperative corneal curvature along the steepest and flattest cornea meridian and overall cornea astigmatism were compared. RESULTS: The curvature along the steepest meridian changed from 44.25 +/- 2.22D preoperatively to 44.08 +/- 2.16D at 3 months postoperatively, and 43.65 +/- 5.23D at 1 year postoperatively (P>0.05); the curvature along the flattest meridian changed from 41.24 +/- 2.21D preoperatively to 43.15 +/- 3.94D at 3 months postoperatively, and 42.85 +/- 5.17D at 1 year postoperatively (P<0.05); and the surgery induced astigmatism (SIA) on cornea was calculated by vector analysis, which was 2.42 +/- 2.13D at 3 months postoperatively, and 2.18 +/- 3.42D at 1 year postoperatively, the difference was statistically significant (P<0.05). CONCLUSION: The scleral flap made along the flattest meridian, under which the posterior chamber intraocular lenses (PCIOL) were sulcus-fixed by trans-scleral suture, can steepen the cornea in varying degrees, thus reducing preexisting corneal astigmatism.展开更多
AIM: To compare visual quality in cataract patients with low corneal astigmatism who underwent intraocular lens(IOL) implantation, and evaluate effects of low levels of astigmatism on visual outcomes in multifocal pse...AIM: To compare visual quality in cataract patients with low corneal astigmatism who underwent intraocular lens(IOL) implantation, and evaluate effects of low levels of astigmatism on visual outcomes in multifocal pseudophakic eyes.METHODS: This retrospective review of clinical records comprised patients with preoperative regular corneal astigmatism of 0.75-1.0 diopters(D) with-the-rule or 0.5-0.75 D against-the-rule who had uneventful cataract surgery and AcrySof IQ ReSTOR Toric-2 IOL(ART2) or AcrySof IQ ReSTOR IOL(ReSTOR) implantation. Retrospective data collection included postoperative ART2 axis rotation, uncorrected astigmatism, uncorrected entire visual acuities, distance corrected entire visual acuities, average modulation transfer function(aMTF), Strehl ratio(SR), spectacle independence, and patient satisfaction between groups.RESULTS: Mean ART2 axis rotation was 3.12°±0.70°. No secondary surgery was required to realign IOL axis. Residual astigmatism values were-0.18±0.07 D and-0.91±0.25 D in groups ART2 and ReSTOR(P<0.05). Three months postoperatively, the mean uncorrected distant, intermediate, and near visual acuities of group A were 0.01±0.05, 0.05±0.07, 0.02±0.07 logMAR, respectively; these were better than those of group R, which were 0.08±0.06, 0.15±0.12, and 0.09±0.08 logMAR, respectively(P<0.05). aMTF, SR, and spectacle independence rates were not significantly different. All patients were satisfied with postoperative results.CONCLUSION: ART2 is more suitable than ReSTOR for cataract patients with regular corneal astigmatism 0.75-1.0 D with-the-rule or 0.5-0.75 D against-the-rule.展开更多
AIM:To evaluate the effects of posterior corneal surface measurements on the accuracy of total estimated corneal astigmatism.METHODS:Fifty-seven patients with toric intraocular lens(IOL) implantation and posterior...AIM:To evaluate the effects of posterior corneal surface measurements on the accuracy of total estimated corneal astigmatism.METHODS:Fifty-seven patients with toric intraocular lens(IOL) implantation and posterior corneal astigmatism exceeding 0.5 diopter were enrolled in this retrospective study.The keratometric astigmatism(KA) and total corneal astigmatism(TA) were measured using a Pentacam rotating Scheimpflug camera to assess the outcomes of AcrySof IOL implantation.Toric lOLs were evaluated in 26 eyes using KA measurements and in 31 eyes using TA measurements.Preoperative corneal astigmatism and postoperative refractive astigmatism were recorded for statistical analysis.The cylindrical power of toric lOLs was estimated in all eyes.RESULTS:In all cases,the difference of toric IOL astigmatism magnitude between KA and TA measurements for the estimation of preoperative corneal astigmatism was statistically significant.Of a total of 57 cases,the 50.88%decreased from Tn to Tn-1 and 10.53%decreased from Tn to Tn-2.In all cases,5.26%increased from Tn to Tn+1.The mean postoperative astigmatism within the TA group was significantly lower than that in the KA group.CONCLUSION:The accuracy of total corneal astigmatism calculations and the efficacy of toric IOL correction can be enhanced by measuring both the anterior and posterior corneal surfaces using a Pentacam rotating Scheimpflug camera.展开更多
AIM: To compare clinical results between toric and spherical periphery design orthokeratology(ortho-k) in myopic children with moderate-to-high corneal astigmatism. METHODS: This retrospective study enrolled 62 ey...AIM: To compare clinical results between toric and spherical periphery design orthokeratology(ortho-k) in myopic children with moderate-to-high corneal astigmatism. METHODS: This retrospective study enrolled 62 eyes of 62 subjects using toric ortho-k lenses. These subjects were assigned to the toric group. Based on the one-to-one match principle(same age, proximate spherical equivalence and corneal astigmatism), 62 eyes of 62 subjects were enrolled and included in the spherical group. At one-year followup visit, visual acuity, corneal astigmatism, treatment zone decentration, axial elongation and adverse reaction were compared between these two groups. RESULTS: At the one-year visit, corneal astigmatism was significantly lower in the toric group(1.22±0.76 D) than in the spherical group(2.05±0.85 D)(P=0.012). The mean magnitude of the treatment zone decentration was 0.62±0.42 mm in the toric group and 1.07±0.40 mm in the spherical group(P=0.004). Axial elongation was significantly slower in the toric group(0.04±0.13 mm) than in the spherical group(0.09±0.13 mm)(P=0.001). The oneyear axial elongation was significantly correlated with initial age(r=-0.487, P〈0.001) and periphery design of ortho-k lens(r=0.315, P〈0.001). The incidence of corneal staining was lower in the toric group(8.1%) than in the spherical group(19.4%)(P〈0.001). CONCLUSION: Toric periphery design ortho-k lenses may provide lower corneal astigmatism, better centration, slower axial elongation and lower incidence of corneal staining in myopic children with moderate-to-high corneal astigmatism.展开更多
Purpose: To compare the impact of induced astigmatism with four different types of multifocal intraocular lenses (MIOLs). Method: Prospective, comparative, interventional, mono-centered study, including 80 eyes of pat...Purpose: To compare the impact of induced astigmatism with four different types of multifocal intraocular lenses (MIOLs). Method: Prospective, comparative, interventional, mono-centered study, including 80 eyes of patients with implantation of four different MIOLs: AcrySof ReSTOR +2.5 D (20 eyes), AcrySof ReSTOR +3.0 D (20 eyes), AcrySof Panoptix (20 eyes) (Alcon Laboratories, Inc., Fort Worth, TX, USA), and Tecnis Symfony ZRX00 (Abbott Medical Optics, Santa Ana, USA) (20 eyes). Patients were followed up for 3 months after surgery. Major parameters were uncorrected (UDVA) and corrected (CDVA) distance visual acuity, subjective refraction and patient satisfaction. Results: Differences between IOLs with regard to the impact of the cylinder sign and axis on visual acuity and patient satisfaction were not significant. With mild added negative cylinder, AcrySof ReSTOR +2.5 D and Tecnis Symfony IOLs maintained the baseline visual acuity, while it was mildly reduced with AcrySof ReSTOR +3.0 D and Panoptix IOLs. With moderate induced cylinder, the Tecnis Symfony IOL maintained good visual acuity and patient associated satisfaction. Panoptix IOL was the IOL most affected by the induced astigmatism with regard to dissatisfaction and visual acuity. The highest tolerance to the astigmatic distortion and blurriness induced with a -1.50 D cylinder was obtained with the Tecnis Symfony IOL. Tecnis Symfony IOL showed less dissatisfaction and less reduction of visual acuity than the other MIOLs. Conclusion: Simulated residual cylinders after the implantation of the Tecnis Symfony IOL up to 1.0 D have a very mild and not clinically relevant impact on visual acuity or patient satisfaction. The ERV IOL showed a better tolerance to unexpected postoperative residual errors than diffractive bifocal and trifocal IOLs.展开更多
AIMTo determine the surgically induced astigmatism (SIA) in Straight, Frown and Inverted V shape (Chevron) incisions in manual small incision cataract surgery (SICS).
AIM: To evaluate the results of three photorefractive keratectomy (PRK) procedures in the treatment of astigmatism. · METHODS: In this retrospective comparative case series, 89 eyes of 50 patients who underwent P...AIM: To evaluate the results of three photorefractive keratectomy (PRK) procedures in the treatment of astigmatism. · METHODS: In this retrospective comparative case series, 89 eyes of 50 patients who underwent PRK treatment for astigmatism were enrolled. The patients were divided into 3 groups based on the PRK procedure: Group 1: PRK without mitomycin -C (MMC) application, Group 2: PRK with MMC application, and Group 3: Trans-Photorefractive Keratectomy (T-PRK). The efficacy, safety, predictability, and complications of treatment were assessed at 1, 3 and 6 months after the treatment. ·RESULTS: At postoperative 6 months, the percentage of postoperative uncorrected visual acuity (UCVA) of 20/ 20 or better was 55.6% (20 eyes) in group 1, 75% (15 eyes) in group 2, and 75.8% (25 eyes) in group 3 (P = 0.144). The percentage of postoperative best corrected visual acuity (BCVA) of unchanged or gained ≥1 lines was 80.6% (29 eyes) in group 1, 70% (14 eyes) in group 2, and 90.9% (30 eyes) in group 3 (P =0.151). The percentage of postoperative BCVA of lost ≥2 lines was 11.1% (4 eyes) in group 1, 20% (4 eyes) in group 2, and 6.1% (2 eyes) in group 3. The mean manifest refractive spherical equivalent (MRSE) and mean cylindrical refraction were not significantly different among the each groups (P 】0.05). At postoperative 6 months, the percentage of MRSE of within ±0.50 D was 100% (36 eyes) in Group 1, 100% (20 eyes) in Group 2, and 93.9% (31 eyes) in Group 3. At the each follow-up period, there was no significant difference in number of eyes with haze and mean haze score(P】0.05). ·CONCLUSION: The study showed that PRK without MMC, PRK with MMC and T-PRK appears to have similareffectiveness, safety and predictability in the treatment of astigmatism. The incidence of haze was also similar between the three groups.展开更多
文摘Objective: To study the postoperative evolution of corneal astigmatism following phaco-alternative at the University Hospital Center of Ouémé-Plateau (UHC-OP) in Porto-Novo. Method: This was a prospective, cross-sectional study with a descriptive and analytical purpose conducted from April 19 to September 20, 2021;a period of 6 months. The study included all patients presenting with senile or non-senile cataracts without a history of corneal trauma and who underwent phaco-alternative during the study period. Results: A total of 62 eyes underwent phaco-alternative. The average age was 63 ± 12 years with a male predominance of 59.7%. Phaco-alternative was performed with 74.2% linear incision and 25.8% smile incision. Perioperative incidents were mainly capsular ruptures with vitreous loss occurring in 8.1% of cases. The mean preoperative astigmatism was 1.29 ± 1.5 D with an axis of 180˚ ± 20˚, indicating with-the-rule astigmatism. The mean postoperative astigmatism was 2.2 ± 1.5 D with an axis of 90˚ ± 20˚, indicating against-the-rule astigmatism. The mean induced astigmatism at Day 30 was 1.4 ± 1.2 D for smile incision and 1.8 ± 1.2 D for linear incision. Conclusion: Phaco-alternative yields good results with few complications but remains astigmatogenic. The smile incision appears to be less astigmatogenic.
文摘AIM:To evaluate the effect of low-degree astigmatism on objective visual quality through the Optical Quality Analysis System(OQAS).METHODS:This study enrolled 46 participants(aged 23 to 30y,90 eyes)with normal or corrected-to-normal vision.The cylindrical lenses(0,0.5,0.75,1.0,and 1.25 D)were placed at the axial direction(180°,45°,90°,and 135°)in front of the eyes with the best correction to form 16 types of regular low-degree astigmatism.OQAS was used to detect the objective visual quality,recorded as the objective scattering index(OSI),OQAS values at contrasts of 100%,20%,and 9%predictive visual acuity(OV100%,OV20%,and OV9%),modulation transfer function cut-off(MTFcut-off)and Strehl ratio(SR).The mixed effect linear model was used to compare objective visual quality differences between groups and examine associations between astigmatic magnitude and objective visual quality parameters.RESULTS:Apparent negative relationships between the magnitude of low astigmatism and objective visual quality were observed.The increase of OSI per degree of astigmatism at 180°,45°,90°,and 135°axis were 0.38(95%CI:0.35,0.42),0.50(95%CI:0.46,0.53),0.49(95%CI:0.45,0.54)and 0.37(95%CI:0.34,0.41),respectively.The decrease of MTFcut-off per degree of astigmatism at 180°,45°,90°,and 135°axis were-10.30(95%CI:-11.43,-9.16),-12.73(95%CI:-13.62,-11.86),-12.75(95%CI:-13.79,-11.70),and-9.97(95%CI:-10.92,-9.03),respectively.At the same astigmatism degree,OSI at 45°and 90°axis were higher than that at 0°and 135°axis,while MTFcut-off were lower.CONCLUSION:Low astigmatism of only 0.50 D can significantly reduce the objective visual quality.
基金Supported by Independent Research Foundation of the 305 Hospital of PLA(No.24ZZJJLW-010).
文摘Among refractive errors,astigmatism is the most common optical aberration,where refraction changes in different meridians of the eye.It causes blurred vision at any distance and includes corneal,lenticular,and retinal astigmatism.Cataract surgery used to cause a progressive increase in the pre-exisiting corneal astigmatism because of creating a surgically induced astigmatism,for example,a large size surgery incision.The development of surgical techniques during last decades has made cataract surgery interchange to treat preoperative corneal astigmatism at time of surgery.Nowadays,three surgical approaches can be used.By placing a sutureless clear corneal incision on the steep meridian of the cornea,a preoperative corneal astigmatism less than 1.0 D can be corrected.Single or paired peripheral corneal relaxing incisions(PCRIs)provide 1.0-3.0 D corneal astigmatism correction.PCRIs are typically used for treating 1.0-1.5 D of regular corneal astigmatism,if more than 2.0 D,the risk of overcorrection and irregular astigmatism is increased.When toric intraocular lenses(IOLs)are unavailable in markets,PCRIs are still a reasonable option for patients with up to 3.0 D of pre-existing corneal astigmatism.Toric IOLs implantation can correct 1.0-4.5 D of corneal astigmatism.Several IOLs are approved to correct a high degree of corneal astigmatism with cylinder power up to 12.0 D.These approaches can be used alone or in combination.
文摘Objective:To explore the corrective effect of posterior chamber intraocular lens implantation with phakic eyes in the treatment of high myopia and astigmatism.Methods:From May 2023,the hospital began to collect the case data of diagnosis and treatment of high myopia and astigmatism.By May 2024,310 cases were included,all of which were treated with posterior chamber intraocular lens implantation.The visual acuity,astigmatism and axial position of the intraocular lens were observed before and after treatment.Results:At different time points after the operation,the patient’s vision was significantly improved compared with that before the operation(P<0.05),and the vision level was equal to or greater than the best-corrected vision before the operation.At different time points after the operation,the average rotation of the intraocular lens was less than 5 degrees.Astigmatism was significantly lower than that before the operation(P<0.05).After the operation,the intraocular pressure increased in 11 cases,accounting for 3.55%,with no adverse complications such as lens turbidity,glare and obvious halo occurring.Conclusion:The posterior chamber intraocular lens implantation with phakic eyes has an ideal correction effect in the treatment of high myopia and astigmatism,which can effectively improve the vision level of patients and reduce the degree of astigmatism,and has high effectiveness and safety.
基金Supported by the Natural Science Foundation of Guangdong Province,China(No.2022A1515010742)Hunan Provincial Natural Science Foundation of China(No.2021JJ30045)the Science Research Grant of Aier Eye Hospital Group(No.AF2102D5,No.AF2201D06,No.AF2201D05).
文摘AIM:To evaluate the effect of symmetrical arc incision correcting corneal astigmatism in femtosecond laserassisted phacoemulsification(FLACS).METHODS:This study enrolled patients with cataract combined with regular corneal astigmatism of>0.75 D,who underwent FLACS.Symmetrical arc incision was set at 8 mm diameter and 85%depth.The follow-up time was 3-24mo(4.92±3.49mo).Pentacam recorded the corneal astigmatism and higher-order aberration at pre-operation and post-operation.The changes in corneal astigmatism were analyzed by Alpins method.The correlation of astigmatism type,age,corneal horizontal diameter,corneal thickness,arc incision length,and correction index(CI)was analyzed,and the residual corneal astigmatism was compared with the residual whole eye astigmatism.RESULTS:Totally 79 patients(102 eyes)were enrolled,10 patients had corneal epithelial injury,1 patient occurred corneal epithelial hyperplasia.The corneal astigmatism was 1.23±0.38 D pre-operation,and decreased to 0.76±0.39 D post-operation(t=10.146,P=0.000).Corneal high-order aberration was 0.17±0.08μm pre-operation and 0.24±0.11μm post-operation(t=-5.186,P=0.000).The residual corneal astigmatism and residual whole eye astigmatism were no significant difference(t=-0.347,P=0.729).Using Alpin’s method,the following were determined:target-induced astigmatism(TIA)=1.23±0.38 D,surgeryinduced astigmatism(SIA)=0.77±0.45 D,difference vector(DV)=0.77±0.39 D,and CI=0.54±0.28.Age,astigmatism size,corneal horizontal diameter,corneal thickness,and arc incision length were not correlated with CI.The CI for against the rule astigmatism(ATR)was better than that for with the rule astigmatism(WTR;P=0.001).CONCLUSION:Femtosecond laser-assisted astigmatic keratotomy has better CI of ATR,but increase higher-order corneal aberration.CI is not ideal,it’s not a perfect choice if we pursue ideal correction effect.
文摘Significance: So far, many scholars have studied the astigmatism caused by glaucoma surgery, but they cannot provide enough useful help for the clinic. When a patient has glaucoma, cataracts and irregular astigmatism at the same time, it is often difficult to achieve satisfactory results. Purpose: This study intends to describe a case of a patient with glaucoma, irregular astigmatism, and cataract who was successfully treated. Additionally, it can serve as a useful source of inspiration for the future care of patients like this. Case Presentation: A 24-year-old male with keratoconus in the past. He had undergone a corneal crosslinking operation in the right eye and a penetrating keratoplasty in the left eye due to his long history of keratoconus in both eyes. Right now, the keratoconus in that eye is stable. Unfortunately, he has now been diagnosed with open-angle glaucoma and complicated cataracts in both eyes, and he was admitted to our hospital for surgery. The right eye had significant irregular astigmatism, which was discovered during the preoperative assessment, and the implantation of a Toric intraocular lens was unable to produce good results. Finally, we chose to perform EXPRESS glaucoma drainage device implantation + phacoemulsification + intraocular lense (ZEISS CT ASPHINA 409MP) implantation. The patient had stable postoperative astigmatism with rule thanks to the traction effect of the scleral flap suture. Astigmatism was typically stable six months after surgery, and the corrected visual acuity with glasses had improved to 20/25. Conclusion: This patient suffers from cataracts, keratoconus, glaucoma, and irregular astigmatism. Due to the interconnectedness of these four disorders, simultaneous success is challenging. We realized that surgically induced astigmatism, frequently affects vision early after filtering surgery for glaucoma patients. In the instance of this patient, we tightly sutured the scleral flap and using tractive action, established regular astigmatism. After the patient’s astigmatism stabilized, optometry was given to correct the vision. This technique should result in much better visual acuity. Finally, it came to pass.
基金Supported by Key R&D Plan of Shaanxi Province:Key Industrial Innovation Chain(Cluster)-Social Development Field(No.2022ZDLSF03-10).
文摘AIM:To assess the visual correction of patients with different degrees of astigmatism with toric soft contact lenses(TSC).METHODS:It was a real-world study with prospective and single-arm design.A total of 384 patients with astigmatism who came for TSC fitting and alignment from November 2022 to January 2023 were included.According to the difference in astigmatism,patients were divided into groups A(cylinder degree:-0.75 to-0.50 D),B(cylinder degree:-1.75 to-1.00 D)and C(cylinder degree≤-2.00 D),and followed up on the day of wear,1wk,1 and 3mo,mainly to observe visual acuity,refraction,lens fit,visual quality and comfort at 1wk after wear.The visual acuity success rate and the overall success rate of the fitting were evaluation indicators(taking into account the four dimensions of visual acuity,fitting,quality of vision and comfort).The visual acuity success rate was calculated by taking“corrected visual acuity with contact lenses is no less than 1 line or better than best spectacle-corrected visual acuity”(i.e.corrected visual acuity with contact lenses is 1 line below,equal to,one line above or more than best spectaclecorrected visual acuity)as the criterion for visual success,and the the overall success rate of the fitting was calculated by using the comprehensive indicators(visual acuity,fit,visual quality,comfort)to meet certain conditions as the judgment criteria for successful fitting.RESULTS:After 1wk of wearing TSC,the visual acuity success rates of patients were 100%(207/207),98.58%(139/141)and 97.22%(35/36)in the three groups,respectively,with residual cylinder closed to 0.The acceptability of the lens fitting was over 95%;the incidence of adverse visual symptoms was within 10%and the comfort acceptability was over 97%.The overall success rate of fitting for patients with high,medium and low astigmatism was 93.72%(194/207),90.78%(128/141)and 88.89%(32/36),respectively.CONCLUSION:TSC(model:G&G POP·CT)are effective in correcting astigmatism in patients with different degrees of astigmatism.
文摘AIM: To evaluate corneal astigmatism after phacoemulsification using 2.2 mm or 1.8 mm clear corneal micro-incisions and its effects on visual function.METHODS: Sixty cases (60 eyes) with cataract were randomly divided into groups A (n=30) and B (n=30) respectively underwent 2.2 mm and 1.8 mm clear corneal tunnel incision phacoemulsification combined with folding intraocular lens implantation from the time direction of 11:00. On day 1 and at 1, 4, and 6wk after operation, patients’ vision was measured and both the corneal curvature and corneal thickness (CT) were recorded using Pentacam.RESULTS: The measured surgery-induced astigmatism (SIA) in both groups A and B peaked on day 1 after operation, and then gradually decreased and eventually stabilized in week 4. No statistically significant difference was found in corneal astigmatism between two groups (P〉0.05). The measured corneal astigmatism at 4wk and 6wk postoperatively were 0.28±0.09 D and 0.27±0.10 D for groups A and 0.27±0.09 D and 0.25±0.10 D for groups B without statistically significant difference (P〉0.05). In addition, no significant differences in visual acuity and CT were found between groups A and B before or after operation.CONCLUSION: Both 2.2 mm and 1.8 mm micro-incision cataract surgeries result in relatively small SIA with no difference in visual function and corneal astigmatism between two surgery approaches. Thus, the two types of surgical systems are safe and efficient for cataract treatment, by which satisfactory uncorrected visual acuity can be regained early postoperatively.
基金Ningxia Scientific and Technological Projects (2012) from Department of Science and Technology in Ningxia Hui Autonomous Region,China(No.2012ZYS175)
文摘AIM: To assess the visual outcomes and possible risk factors associated with axis alignment and rotational stability after implantation of Toric implantable collamer lens (TICL) for the correction of high myopic astigmatism. METHODS: In this prospective, nonrandomized clinical study, 54 consecutive eyes of 29 patients with high myopic astigmatism received TICL implantation. To evaluate postoperative axis deviation from the intended axis, a digital anterior segment photograph was taken. The ultrasound biomicroscopy(UBM) was used to observe footplate-position. RESULTS: After mean follow-up of 8.6 months, mean manifest refractive cylinder (MRC) decreased 79.3% from (-1.88 +/- 1.49)D preoperatively to (0.39 +/- 0.61)D postoperatively. MRC within 1.00D occurred in 68.5% (37/54) of eyes, whereas 48.1% (26/54) had MRC within 0.50D. Mean manifest refraction spherical equivalent (MRSE) changed from (-1208 +/- 422)D preoperatively to (-0.41 +/- 0.61)D postoperatively. Uncorrected binocular vision of 20/20 or better occurred in 72.2% (39/54) of patients compared with binocular best-corrected visual acuity (BCVA) of 20/20 or better in 44.4% (24/54) preoperatively. The mean difference between intended and achieved TICL axes was (6.96 +/- 8.37)degrees. Footplates of TICLs were in the ciliary sulcus in 22 eyes (46.3%), below the ciliary sulcus in 32 eyes (53.7%). The angle of TICL rotation had significant correlation with the footplates-position (t = 2.127; P=0.045) and the postoperative TICL vaulting (r=-0.516; P=0.000). CONCLUSION: The results of our study further support the safety, efficacy and predictability of TICL for the correct high myopic astigmatism. The footplate-position of TICL and vault value should be taken into consideration as two possible risks factors for TICL rotation.
基金Supported by the World Health Organization under National Institute of Health contract N01-EY-2103Fundamental Research Funds of the State Key Laboratory in Ophthalmology+2 种基金National Natural Science Foundation of China (No.81125007)The Research Accelerator Program was at University of Melbourne and the CERA FoundationThe Centre for Eye Research Australia receives Operational Infrastructure Support from the Victorian State Government
文摘AIM: To investigate the influence of astigmatism on visual acuity in school-aged children, and to define a cutoff for clinically significant astigmatism. METHODS: This is a population-based, cross-sectional study. Among 5053 enumerated children aged 5-15 y in Guangzhou, 3729(73.8%) children aged 7-15 with successful cycloplegic auto-refraction(1% cyclopentolate) and a reliable visual acuity measurement were included. Ocular measurement included external eye, anterior segment, media and fundus and cycloplegic auto-refraction. Primary outcome measures included the relationship between severity and subtypes of astigmatism and the prevalence of visual impairment. Three criteria for visual impairment were adopted: best-corrected visual acuity(BCVA) ≤0.7, uncorrected visual acuity(UCVA) ≤0.5 or 〈0.7 in the right eye.RESULTS: Increases of cylinder power was significantly associated with worse visual acuity(UCVA: β=0.051, P〈0.01; BCVA: β=0.025, P〈0.001). A substantial increase in UCVI and BCVI was seen with astigmatism of 1.00 diopter(D) or more. Astigmatism ≥1.00 D had a greater BCVI prevalence than cylinder power less than 1.00 D(OR=4.20, 95%CI: 3.08-5.74), and this was also true for hyperopic, emmetropic and myopic refraction categories. Oblique astigmatism was associated with a higher risk of BCVI relative to with the rule astigmatism in myopic refractive category(OR=12.87, 95%CI: 2.20-75.38).CONCLUSION: Both magnitude and subtypes of astigmatism influence the prevalence of visual impairment in school children. Cylinder ≥1.00 D may be useful as a cutoff for clinically significant astigmatism.
文摘· AIM: To evaluate and compare aspheric toric intraocular lens(IOL) implantation and aspheric monofocal IOL implantation with limbal relaxing incisions(LRI) to manage low corneal astigmatism(1.0-2.0 D) in cataract surgery.· METHODS: A prospective randomized comparative clinical study was performed. There were randomly recruited 102 eyes(102 patients) with cataracts associated with corneal astigmatism and divided into two groups. The first group received toric IOL implantation and the second one monofocal IOL implantation with peripheral corneal relaxing incisions. Outcomes considered were: visual acuity, postoperative residual astigmatism, endothelial cell count, the need for spectacles, and patient satisfaction. To determine the postoperative toric axis, all patients who underwent the toric IOL implantation were further evaluated using an OPD Scan III(Nidek Co, Japan). Follow-up lasted 6mo.· RESULTS: The mean uncorrected distance visual acuity(UCVA) and the best corrected visual acuity(BCVA) demonstrated statistically significant improvement after surgery in both groups. At the end of the follow-up the UCVA was statistically better in the patients with toric IOL implants compared to those patients who underwent implantation of monofocal IOL plus LRI. The mean residual refractive astigmatism was of 0.4 D for the toric IOL group and 1.1 D for the LRI group(P 【0.01). No difference was observed in the postoperative endothelial cell count between the two groups.· CONCLUSION: The two surgical procedures demonstrated a significant decrease in refractive astigmatism. Toric IOL implantation was more effective and predictable compared to the limbal relaxing incision.
基金Supported by National Natural Science Foundation of China (No.31100991) Natural Science Foundation of Tianjin, China (No.15JCQNJ11400)
文摘AIM: To determine the difference of surgical induced astigmatism between conventional 20-gauge sutured vitrectomy and 23-gauge transconjunctival sutureless vitrectomy, and the influence of corneal pachymetry and intraocular pressure(IOP) on surgical induced astigmatism in diabetic patients.METHODS: This retrospective, consecutive case series consisted of 40 eyes of 38 diabetic subjects who underwent either 20-gauge or 23-gauge vitrectomy. The corneal curvature and thickness were measured with Scheimpflug imaging before surgery and 1wk; 1, 3mo after surgery. We compared the surgical induced astigmatism(SIA) on the true net power in 23-gauge group with that in 20-gauge group. We determined the correlation between corneal thickness change ratio, IOP and SIA measured by Pentacam. RESULTS: The mean SIAs were 1.082 ±0.085 D( mean ± SEM), 0.689 ±0.070 D and 0.459 ±0.063 D at postoperative 1wk; 1, 3mo respectively in diabetic subjects. The vitrectomy induced astigmatisms were declined significantly with time(F2,36=33.629, P =0.000)postoperatively. The 23-gauge surgery group induced significantly less astigmatism than 20-gauge surgery group(F1,37=11.046, P =0.020). Corneal thickness in diabetes elevated after surgery(F3,78=10.532, P =0.000).The linear regression analysis at postoperatively 1wk went as: SIA =-4.519 +4.931 change ratio(Port3) +0.026IOP(R2=0.46, P =0.000), whereas the rate of cornealthickness change and IOP showed no correlation with the change of astigmatism at postoperatively 1 and 3mo.CONCLUSION: There are significant serial changes in both 20-gauge and 23-gauge group in diabetic subjects.23-gauge induce less astigmatism than 20-gauge and become stable more rapidly than 20-gauge. The elevation of corneal thickness and IOP was associated with increased astigmatim at the early postoperative stage both in 23-gauge and 20-gauge surgery group.
基金Supported by the National Natural Science Foundation of China(No.81670837)the Scientific and Technological Project of Tianjin Health Bureau(No.2015KY38)
文摘AIM: To explore the effect of the posterior astigmatism on total corneal astigmatism and evaluate the error caused by substituting the corneal astigmatism of the simulated keratometriy (simulated K) for the total corneal astigmatism in age-related cataract patients. METHODS: A total of 211 eyes with age-related cataract from 164 patients (mean age: 66.8±9.0y, range: 45-83y) were examined using a multi-colored spot reflection topographer, and the total corneal astigmatism was measured. The power vector components J0 and J45 were analyzed. Correlations between the magnitude difference of the simulated K and total cornea astigmatism (magnitude differenceSimK-Tca), anterior J0, and absolute meridian difference (AMD) between the anterior and posterior astigmatisms were calculated. To compare the astigmatism of the simulated K and total cornea both in magnitude and axial orientation, we drew double-angle plots and calculated the vector difference between the two measures using vector analysis. A corrective regression formula was used to adjust the magnitude of the simulated K astigmatism to approach that of the total cornea. RESULTS: The magnitude differenceSimK-Tca was positively correlated with the anterior corneal J0 (Spearman’s rho= 0.539; P〈0.001) and negatively correlated with the AMDR (Spearman’s rho=-0.875, P〈0.001). When the anterior J0 value was larger than 1.3 D or smaller than -0.8 D, the errors caused by determining the total corneal astigmatism with the karatometric calculation tended to be greater than 0.25 D. An underestimation by 16% was observed for against the rule (ATR) astigmatism and an overestimation by 9% was observed for with the rule (WTR) astigmatism when ignoring the posterior measurements. CONCLUSION: Posterior corneal astigmatism should be valued for more precise corneal astigmatism management, especially for higher ATR astigmatism of the anterior corneal surface. We suggest a 9% reduction in the magnitude of the simulated K in eyes with WTR astigmatism, and a 16% addition of the magnitude of the simulated K in eyes with ATR astigmatism.
基金Government Foundation of Liaoning Province, Shenyang,China(No.20081059,2008860)
文摘AIM: To study the impact of scleral flap position, under which the posterior chamber intraocular lenses (PC-IOL) were sulcus-fixed by trans-scleral suture, on cornea astigmatism. METHODS: Twenty-six aphakic or cataract eyes were comprised in this prospective noncomparative case series study. Eleven eyes had traumatic cataract removed without sufficient capsular support, 3 had blunt trauma with subluxated traumatic cataract, 8 had undergone vitreoretinal surgery and 4 had congenital cataract removed. The average age was 54 years (range 21-74 years), with 17 men and 7 women. The foldable PC-IOL was fixed in sulcus by trans-scleral suture. The incision for IOL implantation was made 1mm posterior to limbus along the steepest meridian of cornea, while scleral flaps to bury the knots of trans-scleral suture were made along the flattest meridian. All the surgeries were performed by a single doctor (Ma L), and the follow up was at least 13 months (range 13-28 months). The preoperative, 3 months and 1 year postoperative corneal curvature along the steepest and flattest cornea meridian and overall cornea astigmatism were compared. RESULTS: The curvature along the steepest meridian changed from 44.25 +/- 2.22D preoperatively to 44.08 +/- 2.16D at 3 months postoperatively, and 43.65 +/- 5.23D at 1 year postoperatively (P>0.05); the curvature along the flattest meridian changed from 41.24 +/- 2.21D preoperatively to 43.15 +/- 3.94D at 3 months postoperatively, and 42.85 +/- 5.17D at 1 year postoperatively (P<0.05); and the surgery induced astigmatism (SIA) on cornea was calculated by vector analysis, which was 2.42 +/- 2.13D at 3 months postoperatively, and 2.18 +/- 3.42D at 1 year postoperatively, the difference was statistically significant (P<0.05). CONCLUSION: The scleral flap made along the flattest meridian, under which the posterior chamber intraocular lenses (PCIOL) were sulcus-fixed by trans-scleral suture, can steepen the cornea in varying degrees, thus reducing preexisting corneal astigmatism.
文摘AIM: To compare visual quality in cataract patients with low corneal astigmatism who underwent intraocular lens(IOL) implantation, and evaluate effects of low levels of astigmatism on visual outcomes in multifocal pseudophakic eyes.METHODS: This retrospective review of clinical records comprised patients with preoperative regular corneal astigmatism of 0.75-1.0 diopters(D) with-the-rule or 0.5-0.75 D against-the-rule who had uneventful cataract surgery and AcrySof IQ ReSTOR Toric-2 IOL(ART2) or AcrySof IQ ReSTOR IOL(ReSTOR) implantation. Retrospective data collection included postoperative ART2 axis rotation, uncorrected astigmatism, uncorrected entire visual acuities, distance corrected entire visual acuities, average modulation transfer function(aMTF), Strehl ratio(SR), spectacle independence, and patient satisfaction between groups.RESULTS: Mean ART2 axis rotation was 3.12°±0.70°. No secondary surgery was required to realign IOL axis. Residual astigmatism values were-0.18±0.07 D and-0.91±0.25 D in groups ART2 and ReSTOR(P<0.05). Three months postoperatively, the mean uncorrected distant, intermediate, and near visual acuities of group A were 0.01±0.05, 0.05±0.07, 0.02±0.07 logMAR, respectively; these were better than those of group R, which were 0.08±0.06, 0.15±0.12, and 0.09±0.08 logMAR, respectively(P<0.05). aMTF, SR, and spectacle independence rates were not significantly different. All patients were satisfied with postoperative results.CONCLUSION: ART2 is more suitable than ReSTOR for cataract patients with regular corneal astigmatism 0.75-1.0 D with-the-rule or 0.5-0.75 D against-the-rule.
文摘AIM:To evaluate the effects of posterior corneal surface measurements on the accuracy of total estimated corneal astigmatism.METHODS:Fifty-seven patients with toric intraocular lens(IOL) implantation and posterior corneal astigmatism exceeding 0.5 diopter were enrolled in this retrospective study.The keratometric astigmatism(KA) and total corneal astigmatism(TA) were measured using a Pentacam rotating Scheimpflug camera to assess the outcomes of AcrySof IOL implantation.Toric lOLs were evaluated in 26 eyes using KA measurements and in 31 eyes using TA measurements.Preoperative corneal astigmatism and postoperative refractive astigmatism were recorded for statistical analysis.The cylindrical power of toric lOLs was estimated in all eyes.RESULTS:In all cases,the difference of toric IOL astigmatism magnitude between KA and TA measurements for the estimation of preoperative corneal astigmatism was statistically significant.Of a total of 57 cases,the 50.88%decreased from Tn to Tn-1 and 10.53%decreased from Tn to Tn-2.In all cases,5.26%increased from Tn to Tn+1.The mean postoperative astigmatism within the TA group was significantly lower than that in the KA group.CONCLUSION:The accuracy of total corneal astigmatism calculations and the efficacy of toric IOL correction can be enhanced by measuring both the anterior and posterior corneal surfaces using a Pentacam rotating Scheimpflug camera.
基金Supported by Capital’s Funds for Health Improvement and Research(No.2018-2-4092)
文摘AIM: To compare clinical results between toric and spherical periphery design orthokeratology(ortho-k) in myopic children with moderate-to-high corneal astigmatism. METHODS: This retrospective study enrolled 62 eyes of 62 subjects using toric ortho-k lenses. These subjects were assigned to the toric group. Based on the one-to-one match principle(same age, proximate spherical equivalence and corneal astigmatism), 62 eyes of 62 subjects were enrolled and included in the spherical group. At one-year followup visit, visual acuity, corneal astigmatism, treatment zone decentration, axial elongation and adverse reaction were compared between these two groups. RESULTS: At the one-year visit, corneal astigmatism was significantly lower in the toric group(1.22±0.76 D) than in the spherical group(2.05±0.85 D)(P=0.012). The mean magnitude of the treatment zone decentration was 0.62±0.42 mm in the toric group and 1.07±0.40 mm in the spherical group(P=0.004). Axial elongation was significantly slower in the toric group(0.04±0.13 mm) than in the spherical group(0.09±0.13 mm)(P=0.001). The oneyear axial elongation was significantly correlated with initial age(r=-0.487, P〈0.001) and periphery design of ortho-k lens(r=0.315, P〈0.001). The incidence of corneal staining was lower in the toric group(8.1%) than in the spherical group(19.4%)(P〈0.001). CONCLUSION: Toric periphery design ortho-k lenses may provide lower corneal astigmatism, better centration, slower axial elongation and lower incidence of corneal staining in myopic children with moderate-to-high corneal astigmatism.
文摘Purpose: To compare the impact of induced astigmatism with four different types of multifocal intraocular lenses (MIOLs). Method: Prospective, comparative, interventional, mono-centered study, including 80 eyes of patients with implantation of four different MIOLs: AcrySof ReSTOR +2.5 D (20 eyes), AcrySof ReSTOR +3.0 D (20 eyes), AcrySof Panoptix (20 eyes) (Alcon Laboratories, Inc., Fort Worth, TX, USA), and Tecnis Symfony ZRX00 (Abbott Medical Optics, Santa Ana, USA) (20 eyes). Patients were followed up for 3 months after surgery. Major parameters were uncorrected (UDVA) and corrected (CDVA) distance visual acuity, subjective refraction and patient satisfaction. Results: Differences between IOLs with regard to the impact of the cylinder sign and axis on visual acuity and patient satisfaction were not significant. With mild added negative cylinder, AcrySof ReSTOR +2.5 D and Tecnis Symfony IOLs maintained the baseline visual acuity, while it was mildly reduced with AcrySof ReSTOR +3.0 D and Panoptix IOLs. With moderate induced cylinder, the Tecnis Symfony IOL maintained good visual acuity and patient associated satisfaction. Panoptix IOL was the IOL most affected by the induced astigmatism with regard to dissatisfaction and visual acuity. The highest tolerance to the astigmatic distortion and blurriness induced with a -1.50 D cylinder was obtained with the Tecnis Symfony IOL. Tecnis Symfony IOL showed less dissatisfaction and less reduction of visual acuity than the other MIOLs. Conclusion: Simulated residual cylinders after the implantation of the Tecnis Symfony IOL up to 1.0 D have a very mild and not clinically relevant impact on visual acuity or patient satisfaction. The ERV IOL showed a better tolerance to unexpected postoperative residual errors than diffractive bifocal and trifocal IOLs.
文摘AIMTo determine the surgically induced astigmatism (SIA) in Straight, Frown and Inverted V shape (Chevron) incisions in manual small incision cataract surgery (SICS).
文摘AIM: To evaluate the results of three photorefractive keratectomy (PRK) procedures in the treatment of astigmatism. · METHODS: In this retrospective comparative case series, 89 eyes of 50 patients who underwent PRK treatment for astigmatism were enrolled. The patients were divided into 3 groups based on the PRK procedure: Group 1: PRK without mitomycin -C (MMC) application, Group 2: PRK with MMC application, and Group 3: Trans-Photorefractive Keratectomy (T-PRK). The efficacy, safety, predictability, and complications of treatment were assessed at 1, 3 and 6 months after the treatment. ·RESULTS: At postoperative 6 months, the percentage of postoperative uncorrected visual acuity (UCVA) of 20/ 20 or better was 55.6% (20 eyes) in group 1, 75% (15 eyes) in group 2, and 75.8% (25 eyes) in group 3 (P = 0.144). The percentage of postoperative best corrected visual acuity (BCVA) of unchanged or gained ≥1 lines was 80.6% (29 eyes) in group 1, 70% (14 eyes) in group 2, and 90.9% (30 eyes) in group 3 (P =0.151). The percentage of postoperative BCVA of lost ≥2 lines was 11.1% (4 eyes) in group 1, 20% (4 eyes) in group 2, and 6.1% (2 eyes) in group 3. The mean manifest refractive spherical equivalent (MRSE) and mean cylindrical refraction were not significantly different among the each groups (P 】0.05). At postoperative 6 months, the percentage of MRSE of within ±0.50 D was 100% (36 eyes) in Group 1, 100% (20 eyes) in Group 2, and 93.9% (31 eyes) in Group 3. At the each follow-up period, there was no significant difference in number of eyes with haze and mean haze score(P】0.05). ·CONCLUSION: The study showed that PRK without MMC, PRK with MMC and T-PRK appears to have similareffectiveness, safety and predictability in the treatment of astigmatism. The incidence of haze was also similar between the three groups.