In this paper the conception of smart materials and structures is firstly combined with research of air bag,and the main theory of self adapting cushioning of intelligent air bag is expatiated.The intelligent venting...In this paper the conception of smart materials and structures is firstly combined with research of air bag,and the main theory of self adapting cushioning of intelligent air bag is expatiated.The intelligent venting structure is the main part affecting the cushioning result.Electrostrictive material was found having big force,high response speed and wide linearity,and it is fit to utilize in intelligent venting structure. The characteristic of the dynamic response and cushioning actuating of an electrostrictive stack actuator is analyzed,and the result of the computer simulation of the fuzzy control to intelligent venting structure is given.It is concluded that intelligent venting structure has good actuating characteristic and can satisfy the need of intelligent air bag.展开更多
Samples at different setting time were determined by glass syringe method and air bag method, and their results were analyzed. The results showed that concentrations of methane and total hydrocarbons obviously decline...Samples at different setting time were determined by glass syringe method and air bag method, and their results were analyzed. The results showed that concentrations of methane and total hydrocarbons obviously declined with the prolonging of setting time by glass syringe method, and recovery rate of sample declined to 60% after 8 h. In air bag method, analysis results of methane and total hydrocarbons were stabler, and recovery rate of sample was 93% after 8 h.展开更多
We investigated respiratory tumor motion in lung stereotactic body radiotherapy (SBRT) with use of the “Air-Bag System”. 114 patients underwent four-dimensional (4D) computed tomography (CT) from October 2010 to Apr...We investigated respiratory tumor motion in lung stereotactic body radiotherapy (SBRT) with use of the “Air-Bag System”. 114 patients underwent four-dimensional (4D) computed tomography (CT) from October 2010 to April 2012. Gross tumor volume (GTV) was 8.1 ± 11.0 cc (range 0.3 - 77.5 cc). The tumor site was the upper and middle lobes in 62 cases, and lower lobe in 52 cases. The Air-Bag SystemTM consists of an inelastic air bag connected to a second smaller elastic air bag. The inelastic air bag is placed between the patient’s body surface and a HipFix and is secured by pressure adjustment via the elastic air bag. To assess respiratory tumor motion, the centroid of the tumor position is measured in the left-right, anterior-posterior, and caudal-cranial directions using the iPlan RT DoseTM treatment planning system. Respiratory tumor motion vector for patients with upper/middle and lower lobe tumors was 3.0 ± 2.2 mm (range, 0.4 - 11.7 mm) and 6.5 ± 4.6 mm (range, 0.4 - 22.0 mm) respectively, with this difference being significant (p < 0.05). Mean respiratory tumor motion for all patients was 0.9 ± 0.6 mm (range, 0.1 - 3.6 mm) in the left-right direction, 1.5 ± 1.1 mm (range, 0.1 - 5.7 mm) in the anterior-posterior direction, 4.1 ± 4.0 mm (range, 0.1 - 21.4 mm) in the caudal-cranial direction, and 4.7 ± 4.0 mm (range, 0.4 - 22.0 mm) overall. The Air-Bag System is expected to be provided an effective reduction in the motion of lung tumors.展开更多
The air bag deformation data were obtained by high-speed dynamic videos experiments. Based on gas–liquid flow VOF model, dynamic mesh technique and deformation data, numerical simulations for different structure mode...The air bag deformation data were obtained by high-speed dynamic videos experiments. Based on gas–liquid flow VOF model, dynamic mesh technique and deformation data, numerical simulations for different structure models were achieved, and the law of water motion and influencing factors were analyzed.The results show that the flow in the length direction of the jig is smooth, and second pulsation appears in the separation time and forms the secondary separation. The installation position of screen and the number of air bags have a great influence on the uniformity of flow and velocity. The screen height cannot be too low to avoid forming the unstable flow. At the same time, the screen height cannot be too high, otherwise water velocity will be too small and was unable to provide enough power. At the height of 1.4m,velocity unevenness is minimum and the best uniform flow can be obtained. Compared with double air bags, there are the following features of single air bag: water flow is not smooth, the time achieving the maximum velocity is too long, maximum velocity is smaller, and overall effect is worse than double air bags.展开更多
文摘In this paper the conception of smart materials and structures is firstly combined with research of air bag,and the main theory of self adapting cushioning of intelligent air bag is expatiated.The intelligent venting structure is the main part affecting the cushioning result.Electrostrictive material was found having big force,high response speed and wide linearity,and it is fit to utilize in intelligent venting structure. The characteristic of the dynamic response and cushioning actuating of an electrostrictive stack actuator is analyzed,and the result of the computer simulation of the fuzzy control to intelligent venting structure is given.It is concluded that intelligent venting structure has good actuating characteristic and can satisfy the need of intelligent air bag.
基金Supported by Shantou Environmental Protection Science and Technology Project of 2018
文摘Samples at different setting time were determined by glass syringe method and air bag method, and their results were analyzed. The results showed that concentrations of methane and total hydrocarbons obviously declined with the prolonging of setting time by glass syringe method, and recovery rate of sample declined to 60% after 8 h. In air bag method, analysis results of methane and total hydrocarbons were stabler, and recovery rate of sample was 93% after 8 h.
文摘We investigated respiratory tumor motion in lung stereotactic body radiotherapy (SBRT) with use of the “Air-Bag System”. 114 patients underwent four-dimensional (4D) computed tomography (CT) from October 2010 to April 2012. Gross tumor volume (GTV) was 8.1 ± 11.0 cc (range 0.3 - 77.5 cc). The tumor site was the upper and middle lobes in 62 cases, and lower lobe in 52 cases. The Air-Bag SystemTM consists of an inelastic air bag connected to a second smaller elastic air bag. The inelastic air bag is placed between the patient’s body surface and a HipFix and is secured by pressure adjustment via the elastic air bag. To assess respiratory tumor motion, the centroid of the tumor position is measured in the left-right, anterior-posterior, and caudal-cranial directions using the iPlan RT DoseTM treatment planning system. Respiratory tumor motion vector for patients with upper/middle and lower lobe tumors was 3.0 ± 2.2 mm (range, 0.4 - 11.7 mm) and 6.5 ± 4.6 mm (range, 0.4 - 22.0 mm) respectively, with this difference being significant (p < 0.05). Mean respiratory tumor motion for all patients was 0.9 ± 0.6 mm (range, 0.1 - 3.6 mm) in the left-right direction, 1.5 ± 1.1 mm (range, 0.1 - 5.7 mm) in the anterior-posterior direction, 4.1 ± 4.0 mm (range, 0.1 - 21.4 mm) in the caudal-cranial direction, and 4.7 ± 4.0 mm (range, 0.4 - 22.0 mm) overall. The Air-Bag System is expected to be provided an effective reduction in the motion of lung tumors.
基金provided by the Project of National Scientific and Technical Supporting Programs Funded of China(No.2012BAB13B03)
文摘The air bag deformation data were obtained by high-speed dynamic videos experiments. Based on gas–liquid flow VOF model, dynamic mesh technique and deformation data, numerical simulations for different structure models were achieved, and the law of water motion and influencing factors were analyzed.The results show that the flow in the length direction of the jig is smooth, and second pulsation appears in the separation time and forms the secondary separation. The installation position of screen and the number of air bags have a great influence on the uniformity of flow and velocity. The screen height cannot be too low to avoid forming the unstable flow. At the same time, the screen height cannot be too high, otherwise water velocity will be too small and was unable to provide enough power. At the height of 1.4m,velocity unevenness is minimum and the best uniform flow can be obtained. Compared with double air bags, there are the following features of single air bag: water flow is not smooth, the time achieving the maximum velocity is too long, maximum velocity is smaller, and overall effect is worse than double air bags.