期刊文献+
共找到4,297篇文章
< 1 2 215 >
每页显示 20 50 100
Development and Experimental Study of Air Source Heat Pump Water Heater 被引量:2
1
作者 李海峰 蔡正云 《Meteorological and Environmental Research》 CAS 2010年第2期100-102,共3页
The principle and development prospect of air source heat pump water heat were introduced,as well as the designation of condenser (storage water tank),experimental study on installations was also carried out.The resul... The principle and development prospect of air source heat pump water heat were introduced,as well as the designation of condenser (storage water tank),experimental study on installations was also carried out.The results showed that air source heat pump water heater was superior to conventional system.Under the operation of cooling and heating,heat pump comprehensive utilization equipment could improve heating performance,reduce energy consumption,and recycle condensing heat to provide hot water. 展开更多
关键词 air source heat pump water heater China
下载PDF
Modeling and Optimization of Solar Collector Design for the Improvement of Solar-Air Source Heat Pump Building Heating System
2
作者 Jiarui Wu Yuzhen Kang Junxiao Feng 《Energy Engineering》 EI 2023年第12期2783-2802,共20页
To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an impr... To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an improvement in the system’s heat generation coefficient,overall efficiency,and stability.In this study,we focus on a residential building located in Lhasa as the target for heating purposes.Initially,we simulate and analyze a solar-air source heat pump combined heating system.Subsequently,while ensuring the system meets user requirements,we examine the influence of solar collector installation angles and collector area on the performance of the solar-air source heat pump dual heating system.Through this analysis,we determine the optimal installation angle and collector area to optimize system performance. 展开更多
关键词 Solar energy air source heat pump optimization model solar-air heat pump heating system
下载PDF
Research on Operation Optimization of Heating System Based on Electric Storage Coupled Solar Energy and Air Source Heat Pump
3
作者 Jingxiao Han Chuanzhao Zhang +5 位作者 LuWang ZengjunChang Qing Zhao Ying Shi JiaruiWu Xiangfei Kong 《Energy Engineering》 EI 2023年第9期1991-2011,共21页
For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving e... For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving economic efficiency.In this paper,four cities in three climatic regions in China were selected,namely Nanjing in the hot summer and cold winter region,Tianjin in the cold region,Shenyang and Harbin in the severe cold winter region.The levelized cost of heat(LCOH)was used as the economic evaluation index,and the energy consumption and emissions of different pollutants were analyzed.TRNSYS software was used to simulate and analyze the system performance.The Hooke-Jeeves optimization algorithm and GenOpt software were used to optimize the system parameters.The results showed that ECSA systemhad an excellent operation effect in cold region and hot summer and cold winter region.Compared with ECS system,the systemenergy consumption,and the emission of different pollutants of ECSA system can be reduced by a maximum of 1.37 times.In cold region,the initial investment in an air source heat pump is higher due to the lower ambient temperature,resulting in an increase in the LOCH value of ECSA system.After the LOCH value of ECSA system in each region was optimized,the heating cost of the system was reduced,but also resulted in an increase in energy consumption and the emission of different pollutant gases. 展开更多
关键词 Electric heat storage solar energy air source heat pump multi-objective optimization method LOCH
下载PDF
Operating performance of novel reverse-cycle defrosting method based on thermal energy storage for air source heat pump 被引量:7
4
作者 董建锴 姜益强 +1 位作者 姚杨 张雪丹 《Journal of Central South University》 SCIE EI CAS 2011年第6期2163-2169,共7页
To solve the fundamental problem of insufficient heat available during defrosting while ensuring the efficient and safe system operation for air-source heat pumps (ASHPs). A novel reverse-cycle defrosting (NRCD) metho... To solve the fundamental problem of insufficient heat available during defrosting while ensuring the efficient and safe system operation for air-source heat pumps (ASHPs). A novel reverse-cycle defrosting (NRCD) method based on thermal energy storage to eliminate frost off the outdoor coil surface was developed. Comparative experiments using both the stand reverse cycle defrosting (SRCD) method and the NRCD method were carried out on an experimental ASHP unit with a nominal 2.5 kW heating capacity. The results indicate that during defrosting operation, using the NRCD method improves discharge and suction pressures by 0.24 MPa and 0.19 MPa, respectively, shortens defrosting duration by 60%, and reduces the defrosting energy consumption by 48.1% in the experimental environment, compared with those by the use of SRCD method. Therefore, using the NRCD method can shorten the defrosting duration, improve the indoor thermal comfort, and reduce the defrosting energy consumption in defrosting. 展开更多
关键词 air source heat pump thermal energy storage phase change material reverse-cycle defrosting
下载PDF
Operation Performance of Air Source Heat Pump System for Space Heating in Tianjin 被引量:2
5
作者 赵军 陈雁 +1 位作者 曲航 李新国 《Transactions of Tianjin University》 EI CAS 2007年第2期137-141,共5页
An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the ... An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the effect of climate conditions and heating load ratio on the operation behavior. Then heating capacity variation caused by evaporator frosting is analyzed as well. Finally, the defrosting parameters and the technical feasibility are studied for a constant heating demand. The experimental results indicate that both the outlet water temperature drop and the system COP should be taken into account when setting defrosting parameters, and ASHPS is a viable technology for space heating and hot-water production in winter in Tianjin, which can maintain the room temperature above 19 ℃ when the outdoor temperature is -2 ℃. 展开更多
关键词 air source heat pump system(ASHPS) space heating defrosting parameter COP
下载PDF
Study on corrosion behavior of heat exchanger in water source heat pump
6
作者 刘作华 龙洋 +2 位作者 李百战 丁勇 周小霞 《化工进展》 EI CAS CSCD 北大核心 2010年第S1期695-698,共4页
Water source heat pump is a new kind of energy saving process.One of the most common problems for water source heat pump system is the corrosion of the copper in heat exchanger.The quality of water is the key factor.T... Water source heat pump is a new kind of energy saving process.One of the most common problems for water source heat pump system is the corrosion of the copper in heat exchanger.The quality of water is the key factor.The river water collected in six different places of the Yangtze River and Jialing River in Chongqing were analyzed.Various parameters(pH,coexisted ions,and hardness value)were investigated.It showed that the Yangtze River and Jialing River water was suitable for developing water source heat pump technology.Further more,aimed at the temperature and pH of the raw water's variation range in a year,the corrosion behavior of copper material was studied by controlling the water environmental condition.Corrosion rate of copper is accelerated at high temperature and lower pH value. 展开更多
关键词 water source heat pump water quality RIVER water corrosion
下载PDF
Performance and Optimization of Air Source Heat Pump Water Heater with Cyclic Heating
7
作者 李凡 陆高锋 +3 位作者 丁云霄 郑春元 李斌 翟晓强 《Journal of Shanghai Jiaotong university(Science)》 EI 2024年第2期179-187,共9页
A new type of microchannel condenser applied in the air source heat pump water heater(ASHPWH)with cyclic heating was proposed in this study.The operating performance of the ASHPWH was frst tested.Then,the structure of... A new type of microchannel condenser applied in the air source heat pump water heater(ASHPWH)with cyclic heating was proposed in this study.The operating performance of the ASHPWH was frst tested.Then,the structure of the microchannel condenser was optimized with the implement of vortex generators.Finally,a numerical model of the ASHPWH was established and the optimized microchannel condenser was studied.The experimental results showed that the average coefficient of performance(COP)of the 1HP(735 W)ASHPWH reached 3.48.In addition,the optimized microchannel condenser could be matched with a 3 HP(2430W)ASHPWH with an average heating capacity of 10.30 kW,and achieving an average COP of 4.24,14.6%higher than the limit value in the national standard. 展开更多
关键词 air source heat pump water heater(ASHPWH) cyclic heating MICROCHANNEL CONDENSER
原文传递
Development of Instantaneous Hot Water Dispenser Based on Water Source Heat Pump
8
作者 Satoshi Yoshida Ryozo Ooka +1 位作者 Toshiyuki Hino Kazuo Kodama 《Journal of Energy and Power Engineering》 2014年第10期1703-1711,共9页
Natural energy use is important to reduce the energy consumption of buildings. However, further reducing energy consumption with traditional systems is difficult. Therefore, we proposed a MMHP (multi-source and multi... Natural energy use is important to reduce the energy consumption of buildings. However, further reducing energy consumption with traditional systems is difficult. Therefore, we proposed a MMHP (multi-source and multi-use heat pump) to achieve higher efficiency than traditional systems. The MMHP system connects multiple heat sources such as solar heat, the ground, and air and multiple heat uses such as cooling, heating, and a hot water dispenser with a water loop. Each type of heat use side can utilize heat efficiently. However, there is a distinct lack of highly efficient hot water dispensers available. Therefore, we developed the IHWD WS (instantaneous hot water dispenser based on a water source) heat pump. In this study, we developed a prototype of the IHWD WS heat pump. The coefficient of performance of the IHWD WS heat pump was 5.2-8.5 throughout a year. When it is improved, COP (coefficient of performance) is expected to be 9.3-9.9. 展开更多
关键词 heat pumps hot water EFFICIENCY COP ground source.
下载PDF
Experimental study on characteristics of transcritical heat pump water heater using refrigerant HFC125
9
作者 王方 连之伟 +1 位作者 范晓伟 王凤坤 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期182-186,共5页
To evaluate the performance of heat pumps using refrigerant HFC125,an experimental rig of a DC-inverter heat pump water heater is designed and set up,and the research on the transcritical heat pump water heater is car... To evaluate the performance of heat pumps using refrigerant HFC125,an experimental rig of a DC-inverter heat pump water heater is designed and set up,and the research on the transcritical heat pump water heater is carried out experimentally.It is found that there is a top value of the coefficient of performance(COP)when the system runs at 95 Hz of frequency.The relationships between the COP and compressor frequency,condensation pressure,evaporation pressure,condensation water temperature rise,and discharge temperature are discussed and analyzed at 95 Hz.And the COP of the HFC125 transcritical cycle is also compared with that of a R410 subcritical heat pump under the same conditions.The results indicate that there exists an optimum frequency for a better COP,and the system COP shows an increasing tendency with the decrease in condensation pressure and compressor ratio while the evaporation pressure remains invariant,and the COP decreases rapidly when cooling water temperature rises over 47.5 ℃.Compared with the R410A sub-critical cycle,the COP of HFC125 transcritical cycle significantly increases by 12% on average. 展开更多
关键词 HFC125 transcritical cycle heat pump water heater coefficient of performance(COP)
下载PDF
Experimental Study of Thermoelectric Heat Pump Water Heater with Exhaust Heat Recovery from Kitchens 被引量:4
10
作者 LIU Zhong-bing,ZHANG Ling,YANG Zhang,XU Ming,HAN Tian-he(College of Civil Engineering,Hunan University,Changsha,Hunan 410082,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期131-135,共5页
A new kind of thermoelectric heat pump water heater for kitchens exhaust heat recovery was presented,and its performances were investigated under different operating voltages.The experiment results show that the coeff... A new kind of thermoelectric heat pump water heater for kitchens exhaust heat recovery was presented,and its performances were investigated under different operating voltages.The experiment results show that the coefficient of performance decreases and the temperature difference between the hot and cold sides becomes larger with the increase of the operating voltage,but the heating time becomes short.The higher the temperature of water,the greater the temperature difference between the hot and cold sides,leading to a smaller coefficient of performance.Under an exhaust temperature of 36 ℃,the coefficient of performance decreases from 1.66 to 1.22 when the temperature of water increases from 28 ℃ to 46 ℃ with operating voltage 16 V.Performance tests illustrate that,compared with the conventional electrical water heaters,the new kind of thermoelectric heat pump water heater is more coefficient. 展开更多
关键词 THERMOELECTRIC heat pump KITCHENS EXHAUST water heatER COEFFICIENT of performance
下载PDF
Refrigerant Control Strategies for Residential Air-Conditioning and Heat-Pump System 被引量:1
11
作者 SU Shun-yu,ZHANG Chun-zhi,CHEN Jian(College of Urban Construction,Wuhan University of Science and Technology,Wuhan,Hubei 430070,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期91-95,共5页
This paper simulated the optimal refrigerant charge inventory of a refrigeration system in air-conditioning operation and heat-pump operation respectively,and studied the refrigerant control strategies in this system.... This paper simulated the optimal refrigerant charge inventory of a refrigeration system in air-conditioning operation and heat-pump operation respectively,and studied the refrigerant control strategies in this system.The void fraction in two-phase fluid region was calculated by Harms model.And based on distributed parameter model and Harms model,the refrigerant charge inventory in condenser and evaporator were calculated and analyzed in air-conditioning conditions and heat-pump conditions,respectively.The calculating results of different refrigerant mass between refrigeration and heating conditions indicate that the optimal refrigerant charge inventory in heat-pump conditions is lower than that in air-conditioning conditions.To avoid the decrease of COP due to the surplus refrigerant in heating conditions,we introduced the liquid reservoir control method and associate capillary control method.Both of them could increase the heating capacity of the air-source heat pump.The difference of optimal refrigerant charge inventory in air-conditioning and heat-pump system can be controlled by the liquid reservoir or the associate capillary. 展开更多
关键词 air-source heat pump control strategy distributed PARAMETER model CHARGE INVENTORY
下载PDF
Thermodynamic Simulation of CCP in Air-Cooled Heat Pump Unit with HFCs and CO<sub>2</sub>Trans-Critical 被引量:2
12
作者 Feihu Chen Shuguang Liao Guangcai Gong 《Journal of Power and Energy Engineering》 2018年第9期141-164,共24页
The exergy analysis and finite time thermodynamic methods had been employed to analyze the compound condensation process (CCP). It was based on the air-cooling heat pump unit. The cooling capacity of the chiller unit ... The exergy analysis and finite time thermodynamic methods had been employed to analyze the compound condensation process (CCP). It was based on the air-cooling heat pump unit. The cooling capacity of the chiller unit is about 1 kW, and the work refrigerant is R22/R407C/R410A/CO2. The MATLAB/SIMULINK software was employed to build the simulation model. The thermodynamic simulation model is significant for the optimization of parameters of the unit, such as condensation and evaporation temperature and mass flow of the sanitary hot water and size of hot water storage tank. The COP of the CCP of R410A system is about 3% - 5% higher than the CCP of the R22 system, while CCP of the R407C system is a little lower than the CCP of R22 system. And the CCP of CO2 trans-critical system has advantage in the hot supply mode. The simulation method provided a theoretical reference for developing the production of CCP with substitute refrigerant R407C/R410A/CO2. 展开更多
关键词 air-Cooled heat pump Unit Compound Condensation Process (CCP) Exergy Analysis Method Sanitary Hot water MATLAB/SIMULINK Software Fluorine SUBSTITUTE REFRIGERANT R407C/R410A Natural REFRIGERANT CO2
下载PDF
Numerical and Experimental Study on Dynamic Performance of Heat Pump Water Heater with Electronic Expansion Valve
13
作者 Liang Zhang Xianmin Guo Weiguo Li Weihua Wang 《Journal of Energy and Power Engineering》 2012年第10期1582-1588,共7页
A series of experiments on the dynamic performance of the HPWH (heat pump water heater) unit with EXV (electronic expansion valve) under different environmental conditions were conducted. The dynamic heating capac... A series of experiments on the dynamic performance of the HPWH (heat pump water heater) unit with EXV (electronic expansion valve) under different environmental conditions were conducted. The dynamic heating capacity and COP (coefficient of performance) of the HPWH unit under different EXV openings were measured. The effects of the EXV opening on the performance of the HPWH unit were analyzed. Meanwhile, the dynamic performance of the HPWH with EXV was simulated and the results were compared with the experimental one. The experimental results indicate that during heating process, the COP increases firstly and then decreases for a fixed EXV opening, which is in good agreement with the numerical result. For different EXV openings, the COP and heating capacity of the system using larger EXV opening are superior to those using the smaller one in the initial heating stage. While in the late stage, the performance of system using smaller EXV opening is better. It is found that the system performance is improved significantly by changing the EXV opening in the different heating period and the average COP of the HPWH system is increased by 7.6%. 展开更多
关键词 heat pump water heater electronic expansion valve experimental investigation simulation.
下载PDF
Experimental Study of Energy-Saving Air-Conditioner with Hot Water
14
作者 CHEN Jian-bo,CHEN Dan,LU Ying(University of Shanghai for Science and Technology,Shanghai,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期75-78,共4页
Energy-saving air-conditioner with hot water is an air source heat pump air-conditioner,which can also supply hot water.The hot water is heated by a double pipe condenser connected with an air-cooled condenser in seri... Energy-saving air-conditioner with hot water is an air source heat pump air-conditioner,which can also supply hot water.The hot water is heated by a double pipe condenser connected with an air-cooled condenser in series in the system.This experiment of the energy-saving air-conditioner was carried out in the enthalpy-difference air-conditioner laboratory.The hot water temperature and the compressor's discharge and suction pressure were recorded in the working condition,where the ambient temperature was at 43 ℃,35 ℃,21 ℃,7 ℃,and 2 ℃ separately.The results showed that the system operated stably and reliably.This system can supply 240 L hot water at 50 ℃ in the whole year,and its coefficience of performance(COP)is much higher than the conventional air source heat pump system.Its energy conservation was proved by comparing the thermal efficiency with other sourece water heaters. 展开更多
关键词 air-CONDITIONING water heaters energy CONSERVATION heat pump systems thermal efficiency
下载PDF
太阳能-空气源热泵牧草干燥系统制热性能研究 被引量:1
15
作者 钱珊珠 杨海巍 +5 位作者 郭文斌 钱丹珠 张清杨 王振彬 屠旭杰 黄长华 《农机化研究》 北大核心 2024年第2期235-241,共7页
以太阳能-空气源热泵牧草干燥系统为研究对象,通过系统不同工作模式的温升、恒温制热试验及带载试验,分析了温升速率、单位温升能耗、COP及除湿效率。研究结果表明:联合制热模式与太阳能单独制热相比,单位温升耗电量降低了86.2%,温升速... 以太阳能-空气源热泵牧草干燥系统为研究对象,通过系统不同工作模式的温升、恒温制热试验及带载试验,分析了温升速率、单位温升能耗、COP及除湿效率。研究结果表明:联合制热模式与太阳能单独制热相比,单位温升耗电量降低了86.2%,温升速率提高了99~112倍。联合制热模式与热泵单独制热试验相比,在温升过程中温升速率降低了7.7%~17.6%,单位温升耗电量降低8.0%;在恒温制热过程中,前者COP比后者提高了6.5%~11.1%,耗电量降低了5.8%~10.7%;在升温制热过程中前者COP比后者提高了6.0%~10.4%,耗电量降低了6.6%~11.1%。联合干燥模式比热泵单独干燥模式的SMER值高19.8%~36.2%。 展开更多
关键词 牧草 太阳能—空气源热泵 干燥系统 制热性能
下载PDF
光伏光热联合双源热泵系统运行模式研究(1):最佳切换模式验证 被引量:1
16
作者 曲明璐 刘锡荣 +1 位作者 王海洋 张斌 《暖通空调》 2024年第8期67-72,80,共7页
讨论了光伏光热联合双源热泵系统制热运行的最佳切换模式。利用TRNSYS软件建立了仿真模型,对双源(水源、空气源)热泵系统性能系数(COP_(s))进行了计算,提出以某时刻空气源热泵模式或水源热泵模式运行COP_(s)较大者优先运行作为COP_(s)... 讨论了光伏光热联合双源热泵系统制热运行的最佳切换模式。利用TRNSYS软件建立了仿真模型,对双源(水源、空气源)热泵系统性能系数(COP_(s))进行了计算,提出以某时刻空气源热泵模式或水源热泵模式运行COP_(s)较大者优先运行作为COP_(s)切换模式。通过前期实验结果验证了模拟结果的正确性,并与常规的集热水箱温度切换模式进行了对比实验,验证了COP_(s)切换模式的有效性。结果表明,该实验系统以COP_(s)最佳切换模式运行时发电量和发电效率较集热水箱温度切换模式分别提高了5.35%和1.73%,耗电量降低了17.03%,COP_(s)提高了4.91%。 展开更多
关键词 光伏光热 双源热泵 空气源热泵 水源热泵 运行模式 切换模式 系统性能系数(COP_(s))
下载PDF
中深层地埋管热泵供热系统运行特性实测研究 被引量:2
17
作者 邓杰文 彭晨玮 +5 位作者 朱超 李骥 孔维政 李建峰 强文博 魏庆芃 《暖通空调》 2024年第4期113-119,共7页
通过大量工程实测研究,总结了中深层地埋管热泵供热技术的运行特性。中深层地埋管具有出水温度高、取热功率大、长期运行稳定的特点,为热泵系统提供了高品位的低温热源,以提升其运行性能;同时中深层地埋管自身存在间歇蓄热特性,能很好... 通过大量工程实测研究,总结了中深层地埋管热泵供热技术的运行特性。中深层地埋管具有出水温度高、取热功率大、长期运行稳定的特点,为热泵系统提供了高品位的低温热源,以提升其运行性能;同时中深层地埋管自身存在间歇蓄热特性,能很好地满足建筑供热需求变化与柔性用能;无级变频热泵机组更适合与中深层地埋管匹配运行,节能减排效果显著;热源侧水系统具有小流量、大扬程,且阻力随着流量变化而大幅度变化的特性。研究结果可为提升该技术的供热性能提供关键指导。 展开更多
关键词 中深层地埋管 热泵系统 热源侧水系统 运行特征 阻力特性 实测研究
下载PDF
基于ANFIS的太阳能-空气源热泵供暖系统温度控制研究
18
作者 谭心 吴林锋 +3 位作者 虞启辉 刘泽江 王亚辉 孙国鑫 《太阳能学报》 EI CAS CSCD 北大核心 2024年第2期16-22,共7页
针对太阳能-空气源热泵供暖系统运行环境复杂多变,模糊控制器的设计高度依赖人工经验的问题,提出一种基于自适应神经模糊推理系统(ANFIS)改进的模糊控制方法。该方法利用ANFIS在复杂系统建模中的优势,结合供暖系统温度响应特性和实际运... 针对太阳能-空气源热泵供暖系统运行环境复杂多变,模糊控制器的设计高度依赖人工经验的问题,提出一种基于自适应神经模糊推理系统(ANFIS)改进的模糊控制方法。该方法利用ANFIS在复杂系统建模中的优势,结合供暖系统温度响应特性和实际运行数据,建立联合供暖系统变工况ANFIS模型,生成与系统性能适配的模糊规则库并传递给模糊控制器执行。Matlab/Simulink仿真对比试验表明,与单一的模糊控制相比,该方法的控制精度提高了17.65%,调节时间缩短了36.4%,具有更高的控制精度和响应速度。 展开更多
关键词 太阳能 空气源热泵 联合供暖 模糊控制 温度控制 ANFIS
下载PDF
家用空气源热泵热水器微通道冷凝器仿真研究
19
作者 许树学 王家正 +3 位作者 勾倩倩 赵谱 卢天宇 马国远 《北京工业大学学报》 CAS CSCD 北大核心 2024年第5期600-609,共10页
为提升家用空气源热泵热水器水箱外微通道冷凝器的性能,建立了家用空气源热泵热水器水箱外微通道冷凝器的准稳态模型,实验验证结果显示模型误差能控制在±9%以内。依据模型对微通道冷凝器的换热量、换热系数、压降等性能进行仿真研... 为提升家用空气源热泵热水器水箱外微通道冷凝器的性能,建立了家用空气源热泵热水器水箱外微通道冷凝器的准稳态模型,实验验证结果显示模型误差能控制在±9%以内。依据模型对微通道冷凝器的换热量、换热系数、压降等性能进行仿真研究。结果发现,微通道冷凝器为四流程时能够减小压降并保证换热量满足需要;关键参数微通道截面的最佳尺寸在1.6~2.6 mm^(2)系统性能最优,同时扁管内微通道数应控制在16~24根。研究结果为家用空气源热泵热水器微通道冷凝器的设计提供借鉴。 展开更多
关键词 热泵热水器 微通道冷凝器 数学模型 仿真 制热量 优化
下载PDF
严寒地区空气源热泵耦合电磁能系统模拟运行研究
20
作者 冯国会 贾敏 +2 位作者 张磊 李旭林 赫娜 《沈阳建筑大学学报(自然科学版)》 CAS 北大核心 2024年第2期322-329,共8页
目的 为了促进空气源热泵耦合电磁能供热系统在严寒地区住宅建筑中的应用,研究该系统的运行性能和稳定性。方法 以沈阳地区某住宅建筑为例,应用Trnsys软件建立了空气源热泵耦合电磁能供热系统仿真模型,并用实测值对模型进行了验证;深入... 目的 为了促进空气源热泵耦合电磁能供热系统在严寒地区住宅建筑中的应用,研究该系统的运行性能和稳定性。方法 以沈阳地区某住宅建筑为例,应用Trnsys软件建立了空气源热泵耦合电磁能供热系统仿真模型,并用实测值对模型进行了验证;深入探讨空气源热泵耦合电磁能供热系统在供热期的运行特点,并与空气源热泵和电磁能供热系统分别进行比较。结果 空气源热泵耦合电磁能供热系统模型可靠,相对误差可以控制在15%以内;在供热期,室内平均温度可保持在17.97~21.84℃;空气源热泵耦合电磁能供热系统比电磁能供热系统的COP提高了59.17%,空气源热泵耦合电磁能供热系统CO_(2)减排量比空气源热泵和电磁能供热系统分别提高1.47%和59.50%。结论 空气源热泵耦合电磁能供热系统运行和COP变化更为稳定,系统环境效益更佳,室内热舒适性更高。 展开更多
关键词 空气源热泵 电磁能系统 COP 严寒地区 耦合系统
下载PDF
上一页 1 2 215 下一页 到第
使用帮助 返回顶部