In the process of membrane absorption,spontaneous wetting of hydrophobic microporous membrane causes membrane modification and increases membrane phase mass transfer resistance,which have attracted wide interest.Howev...In the process of membrane absorption,spontaneous wetting of hydrophobic microporous membrane causes membrane modification and increases membrane phase mass transfer resistance,which have attracted wide interest.However,due to the limitations of previous testing methods,the study of the spontaneous membrane wetting process is limited.Herein,we present a method for monitoring spontaneous membrane wetting by measuring its alternating current(AC)impedance.The impedance tests of the PVDF flat membranes and hollow fiber membranes were conducted in a two-electrode system.The results of equivalent circuit fitting indicate that the impedance value of the unwetted membrane is about 1.02×10^(10)Ω,which is close to the theoretical value of 1.4×10^(10)Ω,and this method can quantify the electrochemical impedance value of membranes with different degrees of spontaneous wetting.In addition,a method of impedance test for real-time monitoring of spontaneous wetting was designed.During the experiment,the timeliness and continuity of this method are confirmed with exact judgment under different conditions.In future work,the impedance data will be used to build model to predict the percentage of membrane wetting degree.展开更多
基金Fanatical support from the National Natural Science Foundation of China(21576011)and the kind supply of electrochemical workstation from Prof。
文摘In the process of membrane absorption,spontaneous wetting of hydrophobic microporous membrane causes membrane modification and increases membrane phase mass transfer resistance,which have attracted wide interest.However,due to the limitations of previous testing methods,the study of the spontaneous membrane wetting process is limited.Herein,we present a method for monitoring spontaneous membrane wetting by measuring its alternating current(AC)impedance.The impedance tests of the PVDF flat membranes and hollow fiber membranes were conducted in a two-electrode system.The results of equivalent circuit fitting indicate that the impedance value of the unwetted membrane is about 1.02×10^(10)Ω,which is close to the theoretical value of 1.4×10^(10)Ω,and this method can quantify the electrochemical impedance value of membranes with different degrees of spontaneous wetting.In addition,a method of impedance test for real-time monitoring of spontaneous wetting was designed.During the experiment,the timeliness and continuity of this method are confirmed with exact judgment under different conditions.In future work,the impedance data will be used to build model to predict the percentage of membrane wetting degree.