The close-coupled selective catalytic reduction(cc-SCR)catalyst is an effective technology to reduce tailpipe NOx emission during cold start.This paper investigated the optimal ammonia storage under steady and transie...The close-coupled selective catalytic reduction(cc-SCR)catalyst is an effective technology to reduce tailpipe NOx emission during cold start.This paper investigated the optimal ammonia storage under steady and transient state in the cc-SCR.The study showed that a trade-off between NOx conversion efficiency and ammonia slip is observed on the pareto solutions under steady state,and the optimal ammonia storage is calculated with ammonia slip less than 10μL/L based on the ChinaⅥemission legislation.The rapid temperature increase will lead to severe ammonia slip in the transient test cycle.A simplified 0-D calculation method on ammonia slip under transient state is proposed based on kinetic model of ammonia adsorption and desorption.In addition,the effect of ammonia storage,catalyst temperature and temperature increasing rate on ammonia slip are analyzed.The optimal ammonia storage is calculated with maximum ammonia slip less than 100μL/L according to the oxidation efficiency of ammonia slip catalyst(ASC)downstream cc-SCR.It was found that the optimal ammonia storage under transient state is much lower than that under steady state in cc-SCR at lower temperature,and a phase diagram is established to analyze the influence of temperature and temperature increasing rate on optimal ammonia storage.展开更多
基金supported by the National Natural Science Foundation of China(No.51976100)the co-founding of FAW Jiefang Automobile Co.,Ltd.Wuxi Diesel Engine Factory,Saudi Aramco Technologies CompanyShandong Chambroad Petrochemicals Co.,Ltd.with the project“Fuel and Engine Co-optimization for high Efficiency and Net-Zero Emission Heavy-duty Engine”。
文摘The close-coupled selective catalytic reduction(cc-SCR)catalyst is an effective technology to reduce tailpipe NOx emission during cold start.This paper investigated the optimal ammonia storage under steady and transient state in the cc-SCR.The study showed that a trade-off between NOx conversion efficiency and ammonia slip is observed on the pareto solutions under steady state,and the optimal ammonia storage is calculated with ammonia slip less than 10μL/L based on the ChinaⅥemission legislation.The rapid temperature increase will lead to severe ammonia slip in the transient test cycle.A simplified 0-D calculation method on ammonia slip under transient state is proposed based on kinetic model of ammonia adsorption and desorption.In addition,the effect of ammonia storage,catalyst temperature and temperature increasing rate on ammonia slip are analyzed.The optimal ammonia storage is calculated with maximum ammonia slip less than 100μL/L according to the oxidation efficiency of ammonia slip catalyst(ASC)downstream cc-SCR.It was found that the optimal ammonia storage under transient state is much lower than that under steady state in cc-SCR at lower temperature,and a phase diagram is established to analyze the influence of temperature and temperature increasing rate on optimal ammonia storage.