The complete experimental IR spectra and vibrational analysis of the title complex Co(mnt)(dmbpy) were reported in this paper. The results show that the complex molecule has a planar geometry belonging to point group ...The complete experimental IR spectra and vibrational analysis of the title complex Co(mnt)(dmbpy) were reported in this paper. The results show that the complex molecule has a planar geometry belonging to point group C 2v and ground electronic state with spin quartet. A new method for analyzing vibrational spectra of complicated molecule is established. The essential of this method is to point out main fixed points and pivotal vibrational units in assignment for each fundamental band. Two new symbols η (heaving along the specified direction) and M (midpoint of a bond or unit) were defined for describing the vibrational modes accurately.展开更多
Prom investigation of the advantages and disadvantages of conventional tri-voltage method,a method for the measurement of the transmitting transducer's impedance was presented to solve the difficult problem of examin...Prom investigation of the advantages and disadvantages of conventional tri-voltage method,a method for the measurement of the transmitting transducer's impedance was presented to solve the difficult problem of examining the consistency of the transmitting phased array on the single-mode excitation sea spot.In the method based on the system function, the circuit structure of tri-voltage method was used but new parameters were measured.The principle of the method was given first.Then when resistors with different nominal values were used in the circuit,the measured results for the impedance of transducers were reported.The results were compared with the higher precision impedance analyzer.Finally,the error analysis was performed according to the impedance formula and the equivalent circuit parameters were fitted.Under the condition of guaranteeing the sampling precision,by performance analyzing, the resistor value in series was chosen relatively smaller than the impedance of transducer,the measurement of impedance could achieve the same precision as the higher precision impedance analyzer.Finally,the least squares curve-fitting of measured curves indicated that the transducer equivalent electrical parameters could be extracted accurately and used to design the matching network.展开更多
基金Supported by the National Natural Science F oundation of China( No. 2 97710 2 5 )
文摘The complete experimental IR spectra and vibrational analysis of the title complex Co(mnt)(dmbpy) were reported in this paper. The results show that the complex molecule has a planar geometry belonging to point group C 2v and ground electronic state with spin quartet. A new method for analyzing vibrational spectra of complicated molecule is established. The essential of this method is to point out main fixed points and pivotal vibrational units in assignment for each fundamental band. Two new symbols η (heaving along the specified direction) and M (midpoint of a bond or unit) were defined for describing the vibrational modes accurately.
基金supported by the National Natural Science Foundation of China(11004214,10574137)
文摘Prom investigation of the advantages and disadvantages of conventional tri-voltage method,a method for the measurement of the transmitting transducer's impedance was presented to solve the difficult problem of examining the consistency of the transmitting phased array on the single-mode excitation sea spot.In the method based on the system function, the circuit structure of tri-voltage method was used but new parameters were measured.The principle of the method was given first.Then when resistors with different nominal values were used in the circuit,the measured results for the impedance of transducers were reported.The results were compared with the higher precision impedance analyzer.Finally,the error analysis was performed according to the impedance formula and the equivalent circuit parameters were fitted.Under the condition of guaranteeing the sampling precision,by performance analyzing, the resistor value in series was chosen relatively smaller than the impedance of transducer,the measurement of impedance could achieve the same precision as the higher precision impedance analyzer.Finally,the least squares curve-fitting of measured curves indicated that the transducer equivalent electrical parameters could be extracted accurately and used to design the matching network.