We could observe the endoluminal stent graft (SG) following thoracic endovascular aneurysm repair (TEVAR) by a coronary artery angioscope and establish intravascular visualization of SG. The patient was a 70-year-old ...We could observe the endoluminal stent graft (SG) following thoracic endovascular aneurysm repair (TEVAR) by a coronary artery angioscope and establish intravascular visualization of SG. The patient was a 70-year-old woman with the distal aortic arch aneurysm and the descending aortic aneurysm, and debranching TEVAR were performed. After 12 months follow up, urgent hospitalization was required for chest pain, and cardiac catheter examination with a coronary artery angioscope was performed. The endoluminal SG was observed. The observation in angioscope which is a video image is better than CT that is a still image, and observation in blood vessel or SG is possible. It may be possible to observe the endoluminal SG, allowing potential investigation of an endoleak, or the covering status of the SG with the native aortic vessel wall, or the state of intimal membrane formation in the endoluminal graft.展开更多
We observed atherosclerotic plaque phantoms using a novel near-infrared (NIR) hyperspectral imaging (HSI) technique. Data were obtained through saline or blood layers to simulate an angioscopic environment for the pha...We observed atherosclerotic plaque phantoms using a novel near-infrared (NIR) hyperspectral imaging (HSI) technique. Data were obtained through saline or blood layers to simulate an angioscopic environment for the phantom. For the study, we developed a NIR-HSI system with an NIR supercontinuum light source and mercury-cadmium-telluride camera. Apparent spectral absorbance was obtained at wavelengths of 1150 - 2400 nm. Hyperspectral images of lipid were constructed using a spectral angle mapper algorithm. Bovine fat covered with saline or blood was observed using hyperspectral images at a wavelength around 1200 nm. Our results show that NIR-HSI is a promising angioscopic technique with the potential to identify lipid-rich plaques without clamping and saline injection.展开更多
文摘We could observe the endoluminal stent graft (SG) following thoracic endovascular aneurysm repair (TEVAR) by a coronary artery angioscope and establish intravascular visualization of SG. The patient was a 70-year-old woman with the distal aortic arch aneurysm and the descending aortic aneurysm, and debranching TEVAR were performed. After 12 months follow up, urgent hospitalization was required for chest pain, and cardiac catheter examination with a coronary artery angioscope was performed. The endoluminal SG was observed. The observation in angioscope which is a video image is better than CT that is a still image, and observation in blood vessel or SG is possible. It may be possible to observe the endoluminal SG, allowing potential investigation of an endoleak, or the covering status of the SG with the native aortic vessel wall, or the state of intimal membrane formation in the endoluminal graft.
文摘We observed atherosclerotic plaque phantoms using a novel near-infrared (NIR) hyperspectral imaging (HSI) technique. Data were obtained through saline or blood layers to simulate an angioscopic environment for the phantom. For the study, we developed a NIR-HSI system with an NIR supercontinuum light source and mercury-cadmium-telluride camera. Apparent spectral absorbance was obtained at wavelengths of 1150 - 2400 nm. Hyperspectral images of lipid were constructed using a spectral angle mapper algorithm. Bovine fat covered with saline or blood was observed using hyperspectral images at a wavelength around 1200 nm. Our results show that NIR-HSI is a promising angioscopic technique with the potential to identify lipid-rich plaques without clamping and saline injection.