Objective:To assess the effect of proximal femur nail anti-rotation on the functional and radiological outcome of unstable intertrochanteric fractures.Methods:This prospective observational study was conducted in the ...Objective:To assess the effect of proximal femur nail anti-rotation on the functional and radiological outcome of unstable intertrochanteric fractures.Methods:This prospective observational study was conducted in the orthopedic department of a tertiary care hospital.Altogether 86 patients with unstable intertrochanteric fractures treated with proximal femur nail anti-rotation between January 2010 and January 2015 were included.Patients were followed in the outpatient clinic at regular intervals after discharge to assess the radiological union of fractures and complications.The functional outcomes were evaluated after 2 years by Harris hip score.Results:All patients achieved a radiological union of fractures after a mean duration of 24.6 weeks.The follow up showed 23 complications(systemic and local).Eight patients developed urinary tract infections,and three patients developed chest infections,two patients had screw cut-out,one patient had knee stiffness,one patient developed superficial surgical site infection,and four patients developed varus collapse and shortening subsequently.The two year follow up showed that 69(80.2%)patients had an excellent and good functional outcome according to Harris hip score.Conclusions:With lower complication rates,proximal femur nail is a valid and reasonable option especially in treating unstable intertrochanteric fractures.展开更多
Traditional diagnostic techniques including visual examination,ultrasound(US),and magnetic resonance imaging(MRI)have limitations of in-depth information for the detection of nail disorders,resolution,and practicality...Traditional diagnostic techniques including visual examination,ultrasound(US),and magnetic resonance imaging(MRI)have limitations of in-depth information for the detection of nail disorders,resolution,and practicality.This pilot study,for thefirst time,evaluates a dualmodality imaging system that combines photoacoustic tomography(PAT)with the US for the multiparametric quantitative assessment of human nail.The study involved a small cohort offive healthy volunteers who underwent PAT/US imaging for acquiring the nail unit data.The PAT/US dual-modality imaging successfully revealed thefine anatomical structures and microvascular distribution within the nail and nail bed.Moreover,this system utilized multispectral PAT to analyze functional tissue parameters,including oxygenated hemoglobin,deoxyhemoglobin,oxygen saturation,and collagen under tourniquet and cold stimulus tests to evaluate changes in the microcirculation of the nail bed.The quantitative analysis of multispectral PAT reconstructed images demonstrated heightened sensitivity in detecting alterations in blood oxygenation levels and collagen content within the nail bed,under simulated different physiological conditions.This pilot study highlights the potential of PAT/US dual-modality imaging as a real-time,noninvasive diagnostic modality for evaluating human nail health and for early detection of nail bed pathologies.展开更多
Introduction: The management of fractures of the tibia shaft is an important aspect of orthopaedic care, and the selection of the surgical method for fixation can substantially impact patient outcomes. The current rev...Introduction: The management of fractures of the tibia shaft is an important aspect of orthopaedic care, and the selection of the surgical method for fixation can substantially impact patient outcomes. The current review aims to compare the outcomes of adult tibia fractures treated with solid nails to those treated with hollow nails. Methods: A search on Scopus, PubMed, and Cochrane Library, using three keywords (Outcome, Tibia shaft fractures, Nail) was conducted in April 2023. Results were compiled and two independent reviewers screened and selected eligible articles After removing duplicates, titles and abstracts were read to exclude ineligible studies. Full-text articles of the remaining papers were read to select eligible studies which were further critically appraised to ascertain their methodological quality. The data extracted from the selected papers were synthesized using a combination of pooling of results, tests of statistical difference (t-test and chi-square) and narrative synthesis methods. Results: A total of 2295 articles were obtained from the databases and citation searching. A total of 9 papers were identified as eligible and included in the review. Findings revealed that there is no statistical difference in the outcomes of tibia fractures treated with either solid or hollow nail groups such as duration of surgery (p = 0.541), rate of delayed and non-union (p = 0.342), and rate of surgical site infections (p = 0.395). Conclusion: Intramedullary nailing of tibia shaft fractures with either solid or hollow nails have similar functional outcomes.展开更多
Background: Fractures of humeral shaft in adults are common injuries. Humeral shafts non-union either from late presentation after initial treatment by traditional bone setters or failed non-operative orthodox care is...Background: Fractures of humeral shaft in adults are common injuries. Humeral shafts non-union either from late presentation after initial treatment by traditional bone setters or failed non-operative orthodox care is a major problem in this part of the world. This non-union is a major treatment challenge with increased cost of care and morbidity in this part of the world. Humeral shaft non-union can be treated with locked intra-medullary nailing (LIMN) or dynamic compression plating (DCP). Study on comparison of these methods of fixation in this part of the world is scarce in literature search, hence the reason for this study. Objective: The objectives of this study are: (1) to compare early clinical outcome following fixation of humeral shaft fracture nonunion with DCP versus LIMN;(2) to compare the time of radiologic fracture union of DCP with LIMN;(3) to compare complications following fixation of humeral shaft fracture nonunion with DCP versus LIMN. Patients and Methods: This was a randomized control study done for 2 years in which fifty adult patients with humeral shaft non-union were recruited. The patients were grouped into 2 (P = DCP & N = LIMN). Forty five of the patients completed the follow up periods of the study and then analyzed. The P group had ORIF with DCP while the N group had ORIF with LIMN. Both groups had grafting with cancellous bones. Each patient was followed up for a period of 6 months at the time which radiographic union is expected. Any patient without clinical and/or radiographic evidence of union after six months of surgery was diagnosed as having recurrent non-union. The data generated was analyzed using SPSS Version 23. The results were presented in charts and tables. The paired t-test was used while considering p value Result: Forty five patients completed follow up. There was a male preponderance (4:1), right humerus predominated (3:2). Motor vehicular accidents were the commonest cause of the fractures (62%). Most non-union fractures occurred at the level of the middle 3<sup>rd</sup> of the humeral shaft (60%). Failed TBS treatment was the commonest indication for the osteosynthesis (71%). More patients had plating (53%) compared to 47% who had LIMN. Most patients (93.4%) had union between 3 to 6 months irrespective of fixation type with no significant statistical difference between the union rate of DCP and LIMN (p value 0.06) with similar functional outcome and complication rates irrespective of the type of fixation. Conclusion: This study showed that the success rates in term of fracture union, outcome functional grades and complication rates were not directly dependent on the types of the fixation: plating or locked intra-medullary nailing.展开更多
With the aging population,intertrochanteric femur fracture in the elderly has become one of the most serious public health issues and a hot topic of research in trauma orthopedics.Due to the limitations of internal fi...With the aging population,intertrochanteric femur fracture in the elderly has become one of the most serious public health issues and a hot topic of research in trauma orthopedics.Due to the limitations of internal fixation techniques and the insufficient mechanical design of nails,the occurrence of complications delays patient recovery after surgical treatment.Design of a proximal femur bionic nail(PFBN)based on Zhang’s N triangle theory provides triangular supporting fixation,which dramatically decreases the occurrence of complications and has been widely used for clinical treatment of unstable intertrochanteric femur fracture worldwide.In this work,we developed an equivalent biomechanical model to analyze improvement in bone remodeling of unstable intertrochanteric femur fracture through PFBN use.The results show that compared with proximal femoral nail antirotation(PFNA)and InterTan,PFBN can dramatically decrease the maximum strain in the proximal femur.Based on Frost’s mechanostat theory,the local mechanical environment in the proximal femur can be regulated into the medium overload region by using a PFBN,which may render the proximal femur in a state of physiological overload,favoring post-operative recovery of intertrochanteric femur fracture in the elderly.This work shows that PFBN may constitute a panacea for unstable intertrochanteric femur fracture and provides insights into improving methods of internal fixation.展开更多
BACKGROUND The traditional Gamma3 nail is a mainstream treatment for femoral intertrochanteric fractures.Literature reports that the Gamma3U-blade system can increase the stability of the Gamma3 nail and reduce compli...BACKGROUND The traditional Gamma3 nail is a mainstream treatment for femoral intertrochanteric fractures.Literature reports that the Gamma3U-blade system can increase the stability of the Gamma3 nail and reduce complication incidence.However,comparative studies between the Gamma3U-blade and Gamma3 systems are limited;hence,this meta-analysis was performed to explore the clinical efficacy of these two surgical methods.AIM To investigate the clinical efficacy of Gamma3 and Gamma3 U-blade for intertrochanteric fractures.METHODS A computerized search for Chinese and English literature published from 2010 to 2022 was conducted in PubMed,Cochrane,CNKI,Wanfang,and VIP databases.The search keywords were gamma 3,gamma 3 U blade,and intertrochanteric fracture.Additionally,literature tracking was performed on the references of published literature.The data were analyzed using Revman 5.3 software.Two individuals checked the inputs for accuracy.Continuous variables were described using mean difference and standard deviation,and outcome effect sizes were expressed using ratio OR and 95%confidence interval(CI).High heterogeneity was considered at(P<0.05,I2>50%),moderate heterogeneity at I2 from 25%to 50%,and low heterogeneity at(P≥0.05,I2<50%).RESULTS Following a comprehensive literature search,review,and analysis,six articles were selected for inclusion in this study.This selection comprised five articles in English and one in Chinese,with publication years spanning from 2016 to 2022.The study with the largest sample size,conducted by Seungbae in 2021,included a total of 304 cases.Statistical analysis:A total of 1063 patients were included in this meta-analysis.The main outcome indicators were:Surgical time:The Gamma3U blade system had a longer surgical time compared to Gamma3 nails(P=0.006,I2=76%).Tip-apex distance:No statistical significance or heterogeneity was observed(P=0.65,I2=0%).Harris Hip score:No statistical significance was found,and low heterogeneity was detected(P=0.26,I2=22%).Union time:No statistical significance was found,and high heterogeneity was detected(P=0.05,I2=75%).CONCLUSION Our study indicated that the Gamma3 system reduces operative time compared to the Gamma3 U-blade system in treating intertrochanteric fractures.Both surgical methods proved to be safe and effective for this patient group.These findings may offer valuable insights and guidance for future surgical protocols in hip fracture patients.展开更多
BACKGROUND Among the most frequent hip fractures are trochanteric fractures,which usually occur from low-energy trauma like minor falls,especially in older people with osteoporotic bones.AIM To evaluate the treatment ...BACKGROUND Among the most frequent hip fractures are trochanteric fractures,which usually occur from low-energy trauma like minor falls,especially in older people with osteoporotic bones.AIM To evaluate the treatment efficacy of dynamic condylar screws(DCS)and proximal femoral nails(PFN)for unstable intertrochanteric fractures.METHODS To find pertinent randomized controlled trials and retrospective observational studies comparing PFN with DCS for the management of unstable femoral intertrochanteric fractures,a thorough search was carried out.For research studies published between January 1996 and April 2024,PubMed,EMBASE,Scopus,Web of Science,Cochrane Library,and Google Scholar were all searched.The complete texts of the papers were retrieved,vetted,and independently examined by two investigators.Disputes were settled by consensus,and any disagreements that persisted were arbitrated by a third author.RESULTS This study included six articles,comprising a total of 173 patients.Compared to the DCS,the PFN had a shorter operation time[mean difference(MD):-41.7 min,95%confidence interval(95%CI):-63.04 to-20.35,P=0.0001],higher success rates with closed reduction techniques[risk ratio(RR):34.05,95%CI:11.12-104.31,P<0.00001],and required less intraoperative blood transfusion(MD:-1.4 units,95%CI:-1.80 to-1.00,P<0.00001).Additionally,the PFN showed shorter fracture union time(MD:-6.92 wk,95%CI:-10.27 to-3.57,P<0.0001)and a lower incidence of reoperation(RR:0.37,95%CI:0.17-0.82,P=0.01).However,there was no discernible variation regarding hospital stay,implant-related complications,and infections.CONCLUSION Compared to DCS,PFN offers shorter operative times,reduces the blood transfusions requirements,achieves higher closed reduction success,enables faster fracture healing,and lowers reoperation incidence.展开更多
In this editorial,I present my comments on the article by Solarino et al.Conversion hip arthroplasty,which is an optional salvage procedure performed following unsuccessful fixation of intertrochanteric femur fracture...In this editorial,I present my comments on the article by Solarino et al.Conversion hip arthroplasty,which is an optional salvage procedure performed following unsuccessful fixation of intertrochanteric femur fractures in elderly pati-ents,entails more complex processes and higher rates of operative complications than primary arthroplasty.Hence,it is important to consider the appropriateness of the primary treatment choice,as well as the adequacy of nailing fixation for intertrochanteric fractures.This article briefly analyzes the possible factors contributing to the nailing failure of intertrochanteric fractures and attempts to find corresponding countermeasures to prevent fixation failures.It also analyzes the choice of treatment between nailing fixation and primary arthroplasty for intertrochanteric fractures.展开更多
Objective To investigate the operative method and evaluate the clinical outcomes of long proximal femoral nail anti-rotation (PFNA-long) in treating long-segment fracture in middle-up part of femoral bone.Methods From...Objective To investigate the operative method and evaluate the clinical outcomes of long proximal femoral nail anti-rotation (PFNA-long) in treating long-segment fracture in middle-up part of femoral bone.Methods From June 2006 to展开更多
BACKGROUND Proximal femur fractures,including both intracapsular(femoral neck fractures)and extracapsular fractures(intertrochanteric femoral fractures,IFFs),affect around 1.5 million people per year worldwide.Mechani...BACKGROUND Proximal femur fractures,including both intracapsular(femoral neck fractures)and extracapsular fractures(intertrochanteric femoral fractures,IFFs),affect around 1.5 million people per year worldwide.Mechanical failures of intertrochanteric nailing in IFFs could be managed with revision total hip arthroplasty(THA).AIM To describe the surgical complexity and the procedure-related complication rates in patients with trochanteric nailing failure and treated with THA.METHODS Patients referred to our level I trauma center between April 2012 and July 2018 with failed cephalomedullary nailing following trochanteric fractures were retrospectively recruited.All patients underwent a salvage surgical procedure,i.e.,cephalomedullary nail removal and conversion to THA.The same surgical and anesthesiology team performed the surgical procedures under spinal anesthesia.All patients underwent clinical and radiographic follow-ups for at least 24 mo.Complications and re-operations were recorded.RESULTS Seventy-four patients met the inclusion criteria(male:29;female:45;mean age:73.8-years-old;range:65-89)and were included in the current study.The average operative time was 117 min(76-192 min).The average blood loss was 585 mL(430-1720 mL).Among the 74 patients,43(58.1%)required transfusion of three or more blood units.Two patients died within the 4th d after surgery because of pulmonary embolism,and 1 patient died 9 mo after surgery due to ischemic myocardial infarction.The complication rate in the 71 patients who completed the minimum 24-mo follow-up was 22.5%.In 3 cases out of 71(4.2%)periprosthetic acetabular fracture was observed during the followup.One of these periacetabular fractures occurred intraoperatively.An intraoperative periprosthetic femur fracture was observed in 5 patients out of 71(7.0%).Four of these patients needed a re-operation to fix the fracture with plates and cerclages;in one of these patients,femoral stem revision was also necessary.In 4 patients out of 71(5.6%),an early THA dislocation was observed,whereas in 1 case(1.4%)a late THA dislocation was observed.Three patients out of 71(4.2%)developed a periprosthetic joint infection during the study follow-up.CONCLUSION The present study demonstrated that salvage options for IFF fixation failure are complex procedures with a relevant intraoperative and postoperative complication rate.展开更多
Screw connection is a type most commonly applied to timber structures.As important commercial tree species in China,Masson pine and Chinese fir have the potential to prepare wood structures.In this study,the effects o...Screw connection is a type most commonly applied to timber structures.As important commercial tree species in China,Masson pine and Chinese fir have the potential to prepare wood structures.In this study,the effects of the diameter of the self-tapping screw and the guiding bores on the nail holding performance on different sections of Masson pine and Chinese fir dimension lumbers were mainly explored.The results showed that:(1)The nail holding strength of the tangential section was the maximum,followed by that of the radial section,and that of the cross section was the minimum.(2)The nail holding strength of Masson pine was higher than that of Chinese fir.(3)The nail holding strength grew with the increase in the diameter of self-tapping screws,but a large diameter would lead to plastic cracking of the timber,thus further affecting the nail holding strength.Masson pine and Chinese fir reached the maximum nail holding strength when the diameter of self-tapping screws was 3.5 mm.(4)Under a large diameter of screws,prefabricated guiding bores could mitigate timber cracking and improve its nail holding strength.(5)Prefabricated guiding bores were more necessary for the screw connection of Masson pine.The results obtained could provide a scientific basis for the screw connection design of Masson pine and Chinese fir timber structures.展开更多
BACKGROUND The femoral neck dynamic intersection system(FNS)is mechanically more stable than other internal fixation techniques.Current studies have confirmed that the structural design of FNS has good biomechanical p...BACKGROUND The femoral neck dynamic intersection system(FNS)is mechanically more stable than other internal fixation techniques.Current studies have confirmed that the structural design of FNS has good biomechanical properties in European and American populations.However,whether the suitability of the FNS's 130°main nail angle design for Asian populations has been thoroughly investigated remains unclear.AIM To compare the biomechanical stability differences among different main nail angles of the FNS in the treatment of femoral neck fractures in Asian populations.METHODS Computed tomography data of the femur of healthy adult male volunteers were imported into Mimics software to create a three-dimensional model of the femur.The model was adapted to the curve using Geomagic software and imported into Solidworks software to construct the Pauwels I femoral neck fracture model and design the FNS internal fixation model using different main nail angles.Afterward,the models were assembled with the FNS fracture model and meshed using the preprocessing Hypermesh software.Subsequently,they were imported into Abaqus software to analyze and evaluate the biomechanical effects of different angles of the FNS main nail on the treatment of femoral neck fractures.RESULTS The peak displacement of the proximal femur under different angles of FNS fixation under stress was 7.446 millimeters in the 120°group and 7.416 millimeters in the 125°group;in the 130°,135°,and 140°FNS fixation groups,the peak displacement was 7.324 millimeters,8.138 millimeters,and 8.246 millimeters,respectively.In the 120°and 125°FNS fixation groups,the maximum stresses were concentrated at the main nail and the anti-rotation screw,which intersected the fracture line of the femur neck,resulting in peak stresses of 200.7 MPa and 138.8 MPa,respectively.Peak stresses of 208.8 MPa,219.8 MPa,and 239.3 MPa were observed on the angular locking plate distal to the locking screw in the 130°,135°,and 140°fixation groups.CONCLUSION FNS has significant stress distribution properties,a minimal proximal femoral displacement,and an optimal stability for treating femoral neck fractures in Asian populations when performed with a 130°main nail angle.展开更多
文摘Objective:To assess the effect of proximal femur nail anti-rotation on the functional and radiological outcome of unstable intertrochanteric fractures.Methods:This prospective observational study was conducted in the orthopedic department of a tertiary care hospital.Altogether 86 patients with unstable intertrochanteric fractures treated with proximal femur nail anti-rotation between January 2010 and January 2015 were included.Patients were followed in the outpatient clinic at regular intervals after discharge to assess the radiological union of fractures and complications.The functional outcomes were evaluated after 2 years by Harris hip score.Results:All patients achieved a radiological union of fractures after a mean duration of 24.6 weeks.The follow up showed 23 complications(systemic and local).Eight patients developed urinary tract infections,and three patients developed chest infections,two patients had screw cut-out,one patient had knee stiffness,one patient developed superficial surgical site infection,and four patients developed varus collapse and shortening subsequently.The two year follow up showed that 69(80.2%)patients had an excellent and good functional outcome according to Harris hip score.Conclusions:With lower complication rates,proximal femur nail is a valid and reasonable option especially in treating unstable intertrochanteric fractures.
基金supported by the program of Chengdu Fifth people's hospital Fund,No.KYJJ 2021-29the Xinglin Scholars research program,No.YYZX2021037+1 种基金the Chengdu Medical Research Project,Nos.2022055 and 2023022,Chongqing Education Commission,Youth Fund(No.KJQN202000607)Chongqing postdoctoral research project(special funding project,No.2021XM3040).
文摘Traditional diagnostic techniques including visual examination,ultrasound(US),and magnetic resonance imaging(MRI)have limitations of in-depth information for the detection of nail disorders,resolution,and practicality.This pilot study,for thefirst time,evaluates a dualmodality imaging system that combines photoacoustic tomography(PAT)with the US for the multiparametric quantitative assessment of human nail.The study involved a small cohort offive healthy volunteers who underwent PAT/US imaging for acquiring the nail unit data.The PAT/US dual-modality imaging successfully revealed thefine anatomical structures and microvascular distribution within the nail and nail bed.Moreover,this system utilized multispectral PAT to analyze functional tissue parameters,including oxygenated hemoglobin,deoxyhemoglobin,oxygen saturation,and collagen under tourniquet and cold stimulus tests to evaluate changes in the microcirculation of the nail bed.The quantitative analysis of multispectral PAT reconstructed images demonstrated heightened sensitivity in detecting alterations in blood oxygenation levels and collagen content within the nail bed,under simulated different physiological conditions.This pilot study highlights the potential of PAT/US dual-modality imaging as a real-time,noninvasive diagnostic modality for evaluating human nail health and for early detection of nail bed pathologies.
文摘Introduction: The management of fractures of the tibia shaft is an important aspect of orthopaedic care, and the selection of the surgical method for fixation can substantially impact patient outcomes. The current review aims to compare the outcomes of adult tibia fractures treated with solid nails to those treated with hollow nails. Methods: A search on Scopus, PubMed, and Cochrane Library, using three keywords (Outcome, Tibia shaft fractures, Nail) was conducted in April 2023. Results were compiled and two independent reviewers screened and selected eligible articles After removing duplicates, titles and abstracts were read to exclude ineligible studies. Full-text articles of the remaining papers were read to select eligible studies which were further critically appraised to ascertain their methodological quality. The data extracted from the selected papers were synthesized using a combination of pooling of results, tests of statistical difference (t-test and chi-square) and narrative synthesis methods. Results: A total of 2295 articles were obtained from the databases and citation searching. A total of 9 papers were identified as eligible and included in the review. Findings revealed that there is no statistical difference in the outcomes of tibia fractures treated with either solid or hollow nail groups such as duration of surgery (p = 0.541), rate of delayed and non-union (p = 0.342), and rate of surgical site infections (p = 0.395). Conclusion: Intramedullary nailing of tibia shaft fractures with either solid or hollow nails have similar functional outcomes.
文摘Background: Fractures of humeral shaft in adults are common injuries. Humeral shafts non-union either from late presentation after initial treatment by traditional bone setters or failed non-operative orthodox care is a major problem in this part of the world. This non-union is a major treatment challenge with increased cost of care and morbidity in this part of the world. Humeral shaft non-union can be treated with locked intra-medullary nailing (LIMN) or dynamic compression plating (DCP). Study on comparison of these methods of fixation in this part of the world is scarce in literature search, hence the reason for this study. Objective: The objectives of this study are: (1) to compare early clinical outcome following fixation of humeral shaft fracture nonunion with DCP versus LIMN;(2) to compare the time of radiologic fracture union of DCP with LIMN;(3) to compare complications following fixation of humeral shaft fracture nonunion with DCP versus LIMN. Patients and Methods: This was a randomized control study done for 2 years in which fifty adult patients with humeral shaft non-union were recruited. The patients were grouped into 2 (P = DCP & N = LIMN). Forty five of the patients completed the follow up periods of the study and then analyzed. The P group had ORIF with DCP while the N group had ORIF with LIMN. Both groups had grafting with cancellous bones. Each patient was followed up for a period of 6 months at the time which radiographic union is expected. Any patient without clinical and/or radiographic evidence of union after six months of surgery was diagnosed as having recurrent non-union. The data generated was analyzed using SPSS Version 23. The results were presented in charts and tables. The paired t-test was used while considering p value Result: Forty five patients completed follow up. There was a male preponderance (4:1), right humerus predominated (3:2). Motor vehicular accidents were the commonest cause of the fractures (62%). Most non-union fractures occurred at the level of the middle 3<sup>rd</sup> of the humeral shaft (60%). Failed TBS treatment was the commonest indication for the osteosynthesis (71%). More patients had plating (53%) compared to 47% who had LIMN. Most patients (93.4%) had union between 3 to 6 months irrespective of fixation type with no significant statistical difference between the union rate of DCP and LIMN (p value 0.06) with similar functional outcome and complication rates irrespective of the type of fixation. Conclusion: This study showed that the success rates in term of fracture union, outcome functional grades and complication rates were not directly dependent on the types of the fixation: plating or locked intra-medullary nailing.
基金supported by the National Natural Science Foundation of China(32130052,82072447,and 82272578)the Fundamental Research Funds for the Central Universities,Nankai University(730-C02922112 and 730-DK2300010314).
文摘With the aging population,intertrochanteric femur fracture in the elderly has become one of the most serious public health issues and a hot topic of research in trauma orthopedics.Due to the limitations of internal fixation techniques and the insufficient mechanical design of nails,the occurrence of complications delays patient recovery after surgical treatment.Design of a proximal femur bionic nail(PFBN)based on Zhang’s N triangle theory provides triangular supporting fixation,which dramatically decreases the occurrence of complications and has been widely used for clinical treatment of unstable intertrochanteric femur fracture worldwide.In this work,we developed an equivalent biomechanical model to analyze improvement in bone remodeling of unstable intertrochanteric femur fracture through PFBN use.The results show that compared with proximal femoral nail antirotation(PFNA)and InterTan,PFBN can dramatically decrease the maximum strain in the proximal femur.Based on Frost’s mechanostat theory,the local mechanical environment in the proximal femur can be regulated into the medium overload region by using a PFBN,which may render the proximal femur in a state of physiological overload,favoring post-operative recovery of intertrochanteric femur fracture in the elderly.This work shows that PFBN may constitute a panacea for unstable intertrochanteric femur fracture and provides insights into improving methods of internal fixation.
基金Supported by The Clinical Medical Science and Technology Development Fund Project of Jiangsu University,No.JLY2021185.
文摘BACKGROUND The traditional Gamma3 nail is a mainstream treatment for femoral intertrochanteric fractures.Literature reports that the Gamma3U-blade system can increase the stability of the Gamma3 nail and reduce complication incidence.However,comparative studies between the Gamma3U-blade and Gamma3 systems are limited;hence,this meta-analysis was performed to explore the clinical efficacy of these two surgical methods.AIM To investigate the clinical efficacy of Gamma3 and Gamma3 U-blade for intertrochanteric fractures.METHODS A computerized search for Chinese and English literature published from 2010 to 2022 was conducted in PubMed,Cochrane,CNKI,Wanfang,and VIP databases.The search keywords were gamma 3,gamma 3 U blade,and intertrochanteric fracture.Additionally,literature tracking was performed on the references of published literature.The data were analyzed using Revman 5.3 software.Two individuals checked the inputs for accuracy.Continuous variables were described using mean difference and standard deviation,and outcome effect sizes were expressed using ratio OR and 95%confidence interval(CI).High heterogeneity was considered at(P<0.05,I2>50%),moderate heterogeneity at I2 from 25%to 50%,and low heterogeneity at(P≥0.05,I2<50%).RESULTS Following a comprehensive literature search,review,and analysis,six articles were selected for inclusion in this study.This selection comprised five articles in English and one in Chinese,with publication years spanning from 2016 to 2022.The study with the largest sample size,conducted by Seungbae in 2021,included a total of 304 cases.Statistical analysis:A total of 1063 patients were included in this meta-analysis.The main outcome indicators were:Surgical time:The Gamma3U blade system had a longer surgical time compared to Gamma3 nails(P=0.006,I2=76%).Tip-apex distance:No statistical significance or heterogeneity was observed(P=0.65,I2=0%).Harris Hip score:No statistical significance was found,and low heterogeneity was detected(P=0.26,I2=22%).Union time:No statistical significance was found,and high heterogeneity was detected(P=0.05,I2=75%).CONCLUSION Our study indicated that the Gamma3 system reduces operative time compared to the Gamma3 U-blade system in treating intertrochanteric fractures.Both surgical methods proved to be safe and effective for this patient group.These findings may offer valuable insights and guidance for future surgical protocols in hip fracture patients.
文摘BACKGROUND Among the most frequent hip fractures are trochanteric fractures,which usually occur from low-energy trauma like minor falls,especially in older people with osteoporotic bones.AIM To evaluate the treatment efficacy of dynamic condylar screws(DCS)and proximal femoral nails(PFN)for unstable intertrochanteric fractures.METHODS To find pertinent randomized controlled trials and retrospective observational studies comparing PFN with DCS for the management of unstable femoral intertrochanteric fractures,a thorough search was carried out.For research studies published between January 1996 and April 2024,PubMed,EMBASE,Scopus,Web of Science,Cochrane Library,and Google Scholar were all searched.The complete texts of the papers were retrieved,vetted,and independently examined by two investigators.Disputes were settled by consensus,and any disagreements that persisted were arbitrated by a third author.RESULTS This study included six articles,comprising a total of 173 patients.Compared to the DCS,the PFN had a shorter operation time[mean difference(MD):-41.7 min,95%confidence interval(95%CI):-63.04 to-20.35,P=0.0001],higher success rates with closed reduction techniques[risk ratio(RR):34.05,95%CI:11.12-104.31,P<0.00001],and required less intraoperative blood transfusion(MD:-1.4 units,95%CI:-1.80 to-1.00,P<0.00001).Additionally,the PFN showed shorter fracture union time(MD:-6.92 wk,95%CI:-10.27 to-3.57,P<0.0001)and a lower incidence of reoperation(RR:0.37,95%CI:0.17-0.82,P=0.01).However,there was no discernible variation regarding hospital stay,implant-related complications,and infections.CONCLUSION Compared to DCS,PFN offers shorter operative times,reduces the blood transfusions requirements,achieves higher closed reduction success,enables faster fracture healing,and lowers reoperation incidence.
文摘In this editorial,I present my comments on the article by Solarino et al.Conversion hip arthroplasty,which is an optional salvage procedure performed following unsuccessful fixation of intertrochanteric femur fractures in elderly pati-ents,entails more complex processes and higher rates of operative complications than primary arthroplasty.Hence,it is important to consider the appropriateness of the primary treatment choice,as well as the adequacy of nailing fixation for intertrochanteric fractures.This article briefly analyzes the possible factors contributing to the nailing failure of intertrochanteric fractures and attempts to find corresponding countermeasures to prevent fixation failures.It also analyzes the choice of treatment between nailing fixation and primary arthroplasty for intertrochanteric fractures.
文摘Objective To investigate the operative method and evaluate the clinical outcomes of long proximal femoral nail anti-rotation (PFNA-long) in treating long-segment fracture in middle-up part of femoral bone.Methods From June 2006 to
文摘BACKGROUND Proximal femur fractures,including both intracapsular(femoral neck fractures)and extracapsular fractures(intertrochanteric femoral fractures,IFFs),affect around 1.5 million people per year worldwide.Mechanical failures of intertrochanteric nailing in IFFs could be managed with revision total hip arthroplasty(THA).AIM To describe the surgical complexity and the procedure-related complication rates in patients with trochanteric nailing failure and treated with THA.METHODS Patients referred to our level I trauma center between April 2012 and July 2018 with failed cephalomedullary nailing following trochanteric fractures were retrospectively recruited.All patients underwent a salvage surgical procedure,i.e.,cephalomedullary nail removal and conversion to THA.The same surgical and anesthesiology team performed the surgical procedures under spinal anesthesia.All patients underwent clinical and radiographic follow-ups for at least 24 mo.Complications and re-operations were recorded.RESULTS Seventy-four patients met the inclusion criteria(male:29;female:45;mean age:73.8-years-old;range:65-89)and were included in the current study.The average operative time was 117 min(76-192 min).The average blood loss was 585 mL(430-1720 mL).Among the 74 patients,43(58.1%)required transfusion of three or more blood units.Two patients died within the 4th d after surgery because of pulmonary embolism,and 1 patient died 9 mo after surgery due to ischemic myocardial infarction.The complication rate in the 71 patients who completed the minimum 24-mo follow-up was 22.5%.In 3 cases out of 71(4.2%)periprosthetic acetabular fracture was observed during the followup.One of these periacetabular fractures occurred intraoperatively.An intraoperative periprosthetic femur fracture was observed in 5 patients out of 71(7.0%).Four of these patients needed a re-operation to fix the fracture with plates and cerclages;in one of these patients,femoral stem revision was also necessary.In 4 patients out of 71(5.6%),an early THA dislocation was observed,whereas in 1 case(1.4%)a late THA dislocation was observed.Three patients out of 71(4.2%)developed a periprosthetic joint infection during the study follow-up.CONCLUSION The present study demonstrated that salvage options for IFF fixation failure are complex procedures with a relevant intraoperative and postoperative complication rate.
基金funded by the National Natural Science Foundation of China (32160348)Forestry Science and Technology Research Project of Guizhou Forestry Bureau (J[2022]21 and[2020]C14)+1 种基金Department Program of Guizhou Province ([2020]1Y128)the Cultivation Project of Guizhou University of China ([2019]37).
文摘Screw connection is a type most commonly applied to timber structures.As important commercial tree species in China,Masson pine and Chinese fir have the potential to prepare wood structures.In this study,the effects of the diameter of the self-tapping screw and the guiding bores on the nail holding performance on different sections of Masson pine and Chinese fir dimension lumbers were mainly explored.The results showed that:(1)The nail holding strength of the tangential section was the maximum,followed by that of the radial section,and that of the cross section was the minimum.(2)The nail holding strength of Masson pine was higher than that of Chinese fir.(3)The nail holding strength grew with the increase in the diameter of self-tapping screws,but a large diameter would lead to plastic cracking of the timber,thus further affecting the nail holding strength.Masson pine and Chinese fir reached the maximum nail holding strength when the diameter of self-tapping screws was 3.5 mm.(4)Under a large diameter of screws,prefabricated guiding bores could mitigate timber cracking and improve its nail holding strength.(5)Prefabricated guiding bores were more necessary for the screw connection of Masson pine.The results obtained could provide a scientific basis for the screw connection design of Masson pine and Chinese fir timber structures.
基金Supported by Tianjin Science and Technology planning Project,No.21JCQNJC01060Key Project of Tianjin Natural Science Foundation,No.22JCZDJC00340National Key Research and Development Project of China,No.2022YFC3601904.
文摘BACKGROUND The femoral neck dynamic intersection system(FNS)is mechanically more stable than other internal fixation techniques.Current studies have confirmed that the structural design of FNS has good biomechanical properties in European and American populations.However,whether the suitability of the FNS's 130°main nail angle design for Asian populations has been thoroughly investigated remains unclear.AIM To compare the biomechanical stability differences among different main nail angles of the FNS in the treatment of femoral neck fractures in Asian populations.METHODS Computed tomography data of the femur of healthy adult male volunteers were imported into Mimics software to create a three-dimensional model of the femur.The model was adapted to the curve using Geomagic software and imported into Solidworks software to construct the Pauwels I femoral neck fracture model and design the FNS internal fixation model using different main nail angles.Afterward,the models were assembled with the FNS fracture model and meshed using the preprocessing Hypermesh software.Subsequently,they were imported into Abaqus software to analyze and evaluate the biomechanical effects of different angles of the FNS main nail on the treatment of femoral neck fractures.RESULTS The peak displacement of the proximal femur under different angles of FNS fixation under stress was 7.446 millimeters in the 120°group and 7.416 millimeters in the 125°group;in the 130°,135°,and 140°FNS fixation groups,the peak displacement was 7.324 millimeters,8.138 millimeters,and 8.246 millimeters,respectively.In the 120°and 125°FNS fixation groups,the maximum stresses were concentrated at the main nail and the anti-rotation screw,which intersected the fracture line of the femur neck,resulting in peak stresses of 200.7 MPa and 138.8 MPa,respectively.Peak stresses of 208.8 MPa,219.8 MPa,and 239.3 MPa were observed on the angular locking plate distal to the locking screw in the 130°,135°,and 140°fixation groups.CONCLUSION FNS has significant stress distribution properties,a minimal proximal femoral displacement,and an optimal stability for treating femoral neck fractures in Asian populations when performed with a 130°main nail angle.