Debonding at the cement-casing interface is recognized as a principal failure mechanism leading to CO_(2) leakage in wells.This detachment gives rise to a microannulus,which notably possesses greater permeability than...Debonding at the cement-casing interface is recognized as a principal failure mechanism leading to CO_(2) leakage in wells.This detachment gives rise to a microannulus,which notably possesses greater permeability than undamaged cement,undermining its sealing efficacy.Conventionally,the permeability of the microannulus is regarded as a uniform value throughout the well.However,fundamentally,a microannulus is one type of fracture,and its gap or aperture size is affected by the effective stress.In this work,we developed a unique experimental apparatus.This equipment facilitates the curing of cement inside a steel casing,the formation of a microannulus between the casing and the cement,and the investigation of the fluid flow dynamics along the microannulus under laboratory-replicated in situ conditions.The microannulus was formed by injecting fluid from one end of the setup,and receiving similar amount of fluid on the other end signified the development of the leakage channel.Additionally,strain gauges affixed to the casing’s external surface yielded key information on the microannulus’s opening and closure.We observed a noticeable decline in microannulus hydraulic aperture(or permeability)in relation to effective stress and an exponential equation fits their relationship.Our findings also indicate a distinct behavior when comparing liquid CO_(2) with water.Specifically,it is easier for liquid CO_(2) to create the microannulus.However,the hydraulic aperture range for this microannulus(0.7-6 mm)is considerably smaller than that created by water flow(2-17 mm).Finally,we integrated the stressdependent microannulus aperture size into the combined analysis of well mechanical integrity and well leakage.The outcomes consistently demonstrated that when factoring in the stress-dependent aperture sizes,the leakage rates are 3e5 times compared to a fixed aperture model.The traditional assumption of a constant aperture significantly underestimates fluid leakage risks.展开更多
We investigate a novel Ga As-based laser power converters(LPCs) grown by metal-organic chemical vapor deposition(MOCVD),which uses a single monolithic structure with six junctions connected by tunnel junctions to obta...We investigate a novel Ga As-based laser power converters(LPCs) grown by metal-organic chemical vapor deposition(MOCVD),which uses a single monolithic structure with six junctions connected by tunnel junctions to obtain a high output voltage. The LPCs with diameters of active aperture of 2 mm and 4 mm were fabricated and tested. The test results show that under an 808 nm laser,two LPCs both show an open circuit voltage of above 6.5 V. A maximum power conversion efficiency of 50.2% is obtained by 2 mm sample with laser power of 0.256 W,and an output electric power of 1.9 W with laser power of 4.85 W is obtained by 4 mm sample. The performances of the LPCs are deteriorated under illumination of high flux,and the 4 mm sample shows a higher laser power tolerance.展开更多
基金Financial support for this work from the U.S.Department of Energy(DOE)Office of Basic Energy Sciences for“Center for Coupled Chemo-Mechanics of Cementitious Composites for EGS(C4M)”,DOE’s“National Risk Assessment Partnership(NRAP)”programDOE Office of Energy Efficiency&Renewable Energy’s Geothermal Technologies Office for“Advanced Downhole Acoustic Sensing for Wellbore Integrity”is gratefully acknowledged.
文摘Debonding at the cement-casing interface is recognized as a principal failure mechanism leading to CO_(2) leakage in wells.This detachment gives rise to a microannulus,which notably possesses greater permeability than undamaged cement,undermining its sealing efficacy.Conventionally,the permeability of the microannulus is regarded as a uniform value throughout the well.However,fundamentally,a microannulus is one type of fracture,and its gap or aperture size is affected by the effective stress.In this work,we developed a unique experimental apparatus.This equipment facilitates the curing of cement inside a steel casing,the formation of a microannulus between the casing and the cement,and the investigation of the fluid flow dynamics along the microannulus under laboratory-replicated in situ conditions.The microannulus was formed by injecting fluid from one end of the setup,and receiving similar amount of fluid on the other end signified the development of the leakage channel.Additionally,strain gauges affixed to the casing’s external surface yielded key information on the microannulus’s opening and closure.We observed a noticeable decline in microannulus hydraulic aperture(or permeability)in relation to effective stress and an exponential equation fits their relationship.Our findings also indicate a distinct behavior when comparing liquid CO_(2) with water.Specifically,it is easier for liquid CO_(2) to create the microannulus.However,the hydraulic aperture range for this microannulus(0.7-6 mm)is considerably smaller than that created by water flow(2-17 mm).Finally,we integrated the stressdependent microannulus aperture size into the combined analysis of well mechanical integrity and well leakage.The outcomes consistently demonstrated that when factoring in the stress-dependent aperture sizes,the leakage rates are 3e5 times compared to a fixed aperture model.The traditional assumption of a constant aperture significantly underestimates fluid leakage risks.
基金supported by the National Natural Science Foundation of China(Nos.61376065 and 61604171)Zhongtian Technology Group Co.Ltd
文摘We investigate a novel Ga As-based laser power converters(LPCs) grown by metal-organic chemical vapor deposition(MOCVD),which uses a single monolithic structure with six junctions connected by tunnel junctions to obtain a high output voltage. The LPCs with diameters of active aperture of 2 mm and 4 mm were fabricated and tested. The test results show that under an 808 nm laser,two LPCs both show an open circuit voltage of above 6.5 V. A maximum power conversion efficiency of 50.2% is obtained by 2 mm sample with laser power of 0.256 W,and an output electric power of 1.9 W with laser power of 4.85 W is obtained by 4 mm sample. The performances of the LPCs are deteriorated under illumination of high flux,and the 4 mm sample shows a higher laser power tolerance.