期刊文献+
共找到4,287篇文章
< 1 2 215 >
每页显示 20 50 100
Recent advances and innovations in the design and fabrication of wearable flexible biosensors and human health monitoring systems based on conjugated polymers 被引量:1
1
作者 Vinh Van Tran Viet-Duc Phung Daeho Lee 《Bio-Design and Manufacturing》 SCIE EI CAS CSCD 2024年第4期476-516,共41页
Wearable biosensors have received great interest as patient-friendly diagnostic technologies because of their high flexibility and conformability.The growing research and utilization of novel materials in designing we... Wearable biosensors have received great interest as patient-friendly diagnostic technologies because of their high flexibility and conformability.The growing research and utilization of novel materials in designing wearable biosensors have accelerated the development of point-of-care sensing platforms and implantable biomedical devices in human health care.Among numerous potential materials,conjugated polymers(CPs)are emerging as ideal choices for constructing high-performance wearable biosensors because of their outstanding conductive and mechanical properties.Recently,CPs have been extensively incorporated into various wearable biosensors to monitor a range of target biomolecules.However,fabricating highly reliable CP-based wearable biosensors for practical applications remains a significant challenge,necessitating novel developmental strategies for enhancing the viability of such biosensors.Accordingly,this review aims to provide consolidated scientific evidence by summarizing and evaluating recent studies focused on designing and fabricating CP-based wearable biosensors,thereby facilitating future research.Emphasizing the superior properties and benefits of CPs,this review aims to clarify their potential applicability within this field.Furthermore,the fundamentals and main components of CP-based wearable biosensors and their sensing mechanisms are discussed in detail.The recent advancements in CP nanostructures and hybridizations for improved sensing performance,along with recent innovations in next-generation wearable biosensors are highlighted.CPbased wearable biosensors have been—and will continue to be—an ideal platform for developing effective and user-friendly diagnostic technologies for human health monitoring. 展开更多
关键词 Conjugated polymers Wearable biosensors E-skin electronics Implantable biosensors Conductive polymer hydrogels
下载PDF
Overview of novel nanobiosensors for electrochemical and optical diagnosis of leukemia:Challenge and opportunity
2
作者 Ulya Farahdina Tahta Amrillah +3 位作者 Mashuri Mashuri Vannajan Sanghiran Lee Agus Rubiyanto Nasori Nasori 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第4期116-138,共23页
Leukemia is one of the ten types of cancer that causes the biggest death in the world.Compared to other types of cancer,leukemia has a low life expectancy,so an early diagnosis of the cancer is necessary.A new strateg... Leukemia is one of the ten types of cancer that causes the biggest death in the world.Compared to other types of cancer,leukemia has a low life expectancy,so an early diagnosis of the cancer is necessary.A new strategy has been developed to identify various leukemia biomarkers by making blood cancer biosensors,especially by developing nanomaterial applications so that they can improve the performance of the biosensor.Although many biosensors have been developed,the detection of leukemia by using nanomaterials with electrochemical and optical methods is still less carried out compare to other types of cancer biosensors.Even the acoustic and calorimetric testing methods for the detection of leukemia by utilizing nanomaterials have not yet been carried out.Most of the reviewed works reported the use of gold nanoparticles and electrochemical characterization methods for leukemia detection with the object of study being conventional cancer cells.In order to be used clinically by the community,future research must be carried out with a lot of patient blood objects,develop non-invasive leukemia detection,and be able to detect all types of blood cancer specifically with one biosensor.This can lead to a fast and accurate diagnosis thus allowing for early treatment and easy periodic condition monitoring for various types of leukemia based on its biomarker and future design controlable via internet of things(IoT)so that why would be monitoring real times. 展开更多
关键词 biosensor detection LEUKEMIA NANOMATERIAL IoT
下载PDF
A Review: Biosensor Progression in Glucose Monitoring for Patients with Diabetes
3
作者 Megan Sweeney 《Advances in Bioscience and Biotechnology》 CAS 2024年第8期503-510,共8页
Diabetes is a condition that can come to the surface at any point throughout a person’s life. Although Type 1 and Type 2 Diabetes have different triggers that cause them to arise, a person can experience similar comp... Diabetes is a condition that can come to the surface at any point throughout a person’s life. Although Type 1 and Type 2 Diabetes have different triggers that cause them to arise, a person can experience similar complications from either if not monitored and treated accordingly. Through the Diabetes Control and Complications Trial, it was found that a significant way to monitor diabetes is through glucose levels in a person’s body. The research surrounding glucose monitoring dates to the mid-1800s, with the first successful reagent for glucose testing being developed in 1908. Since then, glucose sensing has become one of the most rapidly growing areas of research and development in biosensor technology, creating a competitive market for more advanced, accurate, and convenient glucose monitoring. This article reviews the history of biosensors used for glucose monitoring, and major advancements in biosensor technology to enhance performance and improve quality of life for patients with diabetes. 展开更多
关键词 biosensor Continuous Glucose Monitor SMBG Advances in Glucose Monitoring DIABETES
下载PDF
Nanomaterial-assisted wearable glucose biosensors for noninvasive real-time monitoring:Pioneering point-of-care and beyond
4
作者 Moein Safarkhani Abdullah Aldhaher +5 位作者 Golnaz Heidari Ehsan Nazarzadeh Zare Majid Ebrahimi Warkiani Omid Akhavan YunSuk Huh Navid Rabiee 《Nano Materials Science》 EI CAS CSCD 2024年第3期263-283,共21页
This review explores glucose monitoring and management strategies,emphasizing the need for reliable and userfriendly wearable sensors that are the next generation of sensors for continuous glucose detection.In additio... This review explores glucose monitoring and management strategies,emphasizing the need for reliable and userfriendly wearable sensors that are the next generation of sensors for continuous glucose detection.In addition,examines key strategies for designing glucose sensors that are multi-functional,reliable,and cost-effective in a variety of contexts.The unique features of effective diabetes management technology are highlighted,with a focus on using nano/biosensor devices that can quickly and accurately detect glucose levels in the blood,improving patient treatment and control of potential diabetes-related infections.The potential of next-generation wearable and touch-sensitive nano biomedical sensor engineering designs for providing full control in assessing implantable,continuous glucose monitoring is also explored.The challenges of standardizing drug or insulin delivery doses,low-cost,real-time detection of increased blood sugar levels in diabetics,and early digital health awareness controls for the adverse effects of injectable medication are identified as unmet needs.Also,the market for biosensors is expected to expand significantly due to the rising need for portable diagnostic equipment and an ever-increasing diabetic population.The paper concludes by emphasizing the need for further research and development of glucose biosensors to meet the stringent requirements for sensitivity and specificity imposed by clinical diagnostics while being cost-effective,stable,and durable. 展开更多
关键词 Glucose sensor biosensor Wearable devices NONINVASIVE Real-time monitoring
下载PDF
Novel Sustainable Cellulose Acetate Based Biosensor for Glucose Detection
5
作者 M.F.Elkady E.M.El-Sayed +2 位作者 Mahmoud Samy Omneya A.Koriem H.Shokry Hassan 《Journal of Renewable Materials》 EI CAS 2024年第2期369-380,共12页
In this study,green zinc oxide(ZnO)/polypyrrole(Ppy)/cellulose acetate(CA)film has been synthesized via solvent casting.This film was used as supporting material for glucose oxidase(GOx)to sensitize a glucose biosenso... In this study,green zinc oxide(ZnO)/polypyrrole(Ppy)/cellulose acetate(CA)film has been synthesized via solvent casting.This film was used as supporting material for glucose oxidase(GOx)to sensitize a glucose biosensor.ZnO nanoparticles have been prepared via the green route using olive leaves extract as a reductant.ZnO/Ppy nanocomposite has been synthesized by a simple in-situ chemical oxidative polymerization of pyrrole(Py)monomer using ferric chloride(FeCl3)as an oxidizing agent.The produced materials and the composite films were characterized using X-ray diffraction analysis(XRD),scanning electron microscope(SEM),Fourier transform infrared(FTIR)and thermogravimetric analysis(TGA).Glucose oxidase was successfully immobilized on the surface of the prepared film and then ZnO/Ppy/CA/GOx composite was sputtered with platinum electrode for the current determination at different initial concentrations of glucose.Current measurements proved the suitability and the high sensitivity of the constructed biosensor for the detection of glucose levels in different samples.The performance of the prepared biosensor has been assessed by measuring and comparing glucose concentrations up to 800 ppm.The results affirmed the reliability of the developed biosensor towards real samples which suggests the wide-scale application of the proposed biosensor. 展开更多
关键词 biosensors composite films GLUCOSE POLYPYRROLE green ZnO cellulose acetate
下载PDF
The biofilm characteristics and enhanced performance of a marine microbial-electrolysis-cell-based biosensor under positive anodic potential
6
作者 CAO Yuanyuan ZHANG Chaoqun +2 位作者 LIU Xiang CHENG Liang YANG Yang 《土木与环境工程学报(中英文)》 CSCD 北大核心 2024年第6期221-230,共10页
Microbial fuel cells have already been used as biosensors to monitor assimilable organic carbon(AOC).However,their signal production from AOC is known to be completely suppressed by dissoved oxygen(DO).In this study,t... Microbial fuel cells have already been used as biosensors to monitor assimilable organic carbon(AOC).However,their signal production from AOC is known to be completely suppressed by dissoved oxygen(DO).In this study,two identical microbial electrolysis cell(MEC)based biosensors were inoculated with marine sediment and operated at two different anodic potentials,namely-300 mV and+250 mV relative to Ag/AgCl.The MEC biosensor operated under positive anodic potential conditions had electrochemically active microbial communities on the anode,including members of the Shewanellaceae,Pseudoalteromonadaceae,and Clostridiaceae families.However,the strictly anaerobic members of the Desulfuromonadaceae,Desulfobulbaceae and Desulfobacteraceae families were found only in the negative anodic potential MEC biosensor.The positive anodic potential MEC biosensor showed several other advantages as well,such as faster start-up,significantly higher maximum current production,fivefold improvement in the AOC detection limit,and tolerance of low dissolved oxygen,compared to those obtained from the negative anodic potential MEC biosensor.The developed positive anodic potential MEC biosensor can thus be used as a real-time and inexpensive detector of AOC concentrations in high saline and low DO seawater. 展开更多
关键词 biosensor microbial fuel cell anodic potential marine biofilm assimilable organic carbon
下载PDF
Construction of Electrochemical Biosensors Based on the CRISPR/Cas12 System for Applications
7
作者 Hongqu Liang Liu Huang +3 位作者 Peng Yan Fa Huang Hongchao Zhang Qisheng Luo 《Materials Sciences and Applications》 2024年第9期285-304,共20页
The current major issue in improving detection sensitivity and selectivity is to design an electrochemical sensor that does not require PCR amplification for nucleic acid identification and measurement. Because of the... The current major issue in improving detection sensitivity and selectivity is to design an electrochemical sensor that does not require PCR amplification for nucleic acid identification and measurement. Because of their great sensitivity, precision, and simplicity of downsizing, electrochemical biosensors have emerged as a research hotspot in the field of nucleic acid detection. The CRISPR/Cas12 system has emerged as a potent tool for nucleic acid detection due to its powerful cleavage activity and selectivity. Specific electrode changes combined with the CRISPR/Cas12 system can greatly improve the performance of electrochemical biosensors. In this study, the design concepts of electrochemical biosensors based on the CRISPR/Cas12 system and their application advancements in nucleic acid detection are discussed. 展开更多
关键词 CRISPR Cas12 Electrochemical biosensor
下载PDF
Advancing healthcare through laboratory on a chip technology:Transforming microorganism identification and diagnostics
8
作者 Carlos M Ardila 《World Journal of Clinical Cases》 SCIE 2025年第3期9-19,共11页
In a recent case report in the World Journal of Clinical Cases,emphasized the crucial role of rapidly and accurately identifying pathogens to optimize patient treatment outcomes.Laboratory-on-a-chip(LOC)technology has... In a recent case report in the World Journal of Clinical Cases,emphasized the crucial role of rapidly and accurately identifying pathogens to optimize patient treatment outcomes.Laboratory-on-a-chip(LOC)technology has emerged as a transformative tool in health care,offering rapid,sensitive,and specific identification of microorganisms.This editorial provides a comprehensive overview of LOC technology,highlighting its principles,advantages,applications,challenges,and future directions.Success studies from the field have demonstrated the practical benefits of LOC devices in clinical diagnostics,epidemiology,and food safety.Comparative studies have underscored the superiority of LOC technology over traditional methods,showcasing improvements in speed,accuracy,and portability.The future integration of LOC with biosensors,artificial intelligence,and data analytics promises further innovation and expansion.This call to action emphasizes the importance of continued research,investment,and adoption to realize the full potential of LOC technology in improving healthcare outcomes worldwide. 展开更多
关键词 Laboratory-on-a-chip Microorganism identification DIAGNOSTICS Point-ofcare testing biosensors
下载PDF
Mushroom Pulp Tissue-Based Membrane-Ferrocene-Modified L-Tyrosine Biosensor
9
作者 马全红 邓家祺 《Journal of Southeast University(English Edition)》 EI CAS 2000年第1期106-110,共5页
A new approach for assembling amperometric mushroom pulp tissue based membrane electrode for determination of L tyrosine analysis is proposed. Ferrocene is used as a mediator of electron transfer between tyrosinase ... A new approach for assembling amperometric mushroom pulp tissue based membrane electrode for determination of L tyrosine analysis is proposed. Ferrocene is used as a mediator of electron transfer between tyrosinase in mushroom tissue and a graphite electrode. The optimal operation conditions are studied. The linear response range of the biosensor is 2 0×10 -4 to 4 5×10 -3 mol·L -1 with response time of less than 5 min and lifetime of at least 30 d. The biosensor can be applied to practical sample analysis. 展开更多
关键词 biosensor tissue based membrane electrode modified electrode FERROCENE L tyrosine
下载PDF
Toxicity assessment of heavy metals and organic compounds using CellSense biosensor with E.coli 被引量:15
10
作者 Hong Wang Xue Jiang Wang Jian Fu Zhao Ling Chen 《Chinese Chemical Letters》 SCIE CAS CSCD 2008年第2期211-214,共4页
A new strategy using an arnperometric biosensor with Escherichia coli (E. coli) that provides a rapid toxicity determination of chemical compounds is described. The CellSense biosensor system comprises a biological ... A new strategy using an arnperometric biosensor with Escherichia coli (E. coli) that provides a rapid toxicity determination of chemical compounds is described. The CellSense biosensor system comprises a biological component immobilized in intimate contact with a transducer which converts the biochemical signal into a quantifiable electrical signal. Toxicity assessment of heavy metals using E.coli biosensors could be finished within 30 min and the 50% effective concentrations (ECso) values of four heavy metals were determined. The results shows that inhibitory effects of four heavy metals to E.coli can be ranked in a decreasing order of Hg^2+ 〉 Cu^2+ 〉 Zn^2+ 〉 Ni^2+, which accords to the results of conventional bacterial counting method. The toxicity test of organic compounds by using CellSense biosensor was also demonstrated. The CellSense biosensor with E. coli shows a good, reproducible behavior and can be used for reproducible measurements. 展开更多
关键词 Whole-cell biosensor Heavy metal Organic compounds TOXICITY
下载PDF
Using a Surface Plasmon Resonance Biosensor for Rapid Detection of Salmonella Typhimurium in Chicken Carcass 被引量:18
11
作者 Yu-bin Lan Shi-zhou Wang +2 位作者 Yong-guang Yin W. Clint Hoffmann Xian-zhe Zheng 《Journal of Bionic Engineering》 SCIE EI CSCD 2008年第3期239-246,共8页
Chicken is one of the most popular meat products in the world. Salmonella Typhimurium is a common foodbome pathogens associated with the processing of poultry. An optical Surface Plasmon Resonance (SPR) biosensor wa... Chicken is one of the most popular meat products in the world. Salmonella Typhimurium is a common foodbome pathogens associated with the processing of poultry. An optical Surface Plasmon Resonance (SPR) biosensor was sensitive to the presence of Salmonella Typhimurium in chicken carcass. The Spreeta biosensor kits were used to detect Salmonella Typhimurium on chicken carcass successfully. A taste sensor like electronic tongue or biosensors was used to basically "taste" the object and differentiated one object from the other with different taste sensor signatures. The surface plasmon resonance biosensor has potential for use in rapid, real-time detection and identification of bacteria, and to study the interaction of organisms with dif- ferent antisera or other molecular species. The selectivity of the SPR biosensor was assayed using a series of antibody con- centrations and dilution series of the organism. The SPR biosensor showed promising to detect the existence of Salmonella Typhimurium at 1 x 106 CFU/ml. Initial results show that the SPR biosensor has the potential for its application in pathogenic bacteria monitoring. However, more tests need to be done to confirm the detection limitation. 展开更多
关键词 biosensor Salmonella Typhimurium food safety chicken carcass detection limitation Surface Plasmon Resonance
下载PDF
A New Method for the Synthesis of Selenium Nanoparticles and the Application to Construction of H_2O_2 Biosensor 被引量:7
12
作者 JuanZHANG ShengYiZHANG JingJuanXU HongYuanCHEN 《Chinese Chemical Letters》 SCIE CAS CSCD 2004年第11期1345-1348,共4页
The well-distributed, stable selenium nanoparticles (10 nm) with good adhesive ability and biocompatibility were successfully synthesized by using the template of chitosan cross-linked with glutaradehyde. The resulti... The well-distributed, stable selenium nanoparticles (10 nm) with good adhesive ability and biocompatibility were successfully synthesized by using the template of chitosan cross-linked with glutaradehyde. The resulting selenium nanoparticles were used as a new carrier for horseradish peroxidase to construct H2O2 biosensors with good performances. 展开更多
关键词 Selenium nanoparticle synthesis IMMOBILIZATION H2O2 biosensor.
下载PDF
A novel thermal biosensor based on enzyme reaction for pesticides measurement 被引量:7
13
作者 ZHENGYi-hua HUATse-chao XUFei 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2005年第4期615-619,共5页
A novel thermal biosensor based on enzyme reaction for pesticides detection has been developed. This biosensor is a flow injection analysis system and consists of two channels with enzyme reaction column and identical... A novel thermal biosensor based on enzyme reaction for pesticides detection has been developed. This biosensor is a flow injection analysis system and consists of two channels with enzyme reaction column and identical reference column, which is set for eliminating the unspecific heat. The enzyme reaction takes place in the enzyme reaction column at a constant temperature(40℃) realized by a thermoelectric thermostat. Thermosensor based on the thermoelectric module containing 127 serial BiTe-thermocouples is used to monitor the temperature difference between two effluents from enzyme reaction column and reference column. The ability of this biosensor to detect pesticides is demonstrated by the decreased degree of the hydrolytic heat in two types of thermosensor mode. The hydrolytic reaction is inhibited by 36% at 1 mg/L DDVP and 50 % at 10 mg/L DDVP when cell-typed thermosensor is used. The percent inhibition is 30% at 1 mg/L DDVP and 42% at 10 mg/L DDVP in tube-typed thermosensor mode. The detection for real sample shows that this biosensor can be used for detection of organophosphate pesticides residue. 展开更多
关键词 thermal biosensor pesticides residue thermoelectric module flow injection analysis(FIA)
下载PDF
Preparation of Anti-cardiac Troponin I Monoclonal Antibodies and Their Characterization with Surface Plasmon Resonance Biosensor 被引量:4
14
作者 WEIJing-yan LIUXia +3 位作者 SONGDa-qian BULi-sha HUXing MUYing 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2003年第2期183-189,共7页
Cardiac troponin I(cTnI) was separated and purified from human left ventricular tissue by affinity chromatographic method and used to immunize Balb/c mice by intraperitoneal injection and four hybridoma cell lines, wh... Cardiac troponin I(cTnI) was separated and purified from human left ventricular tissue by affinity chromatographic method and used to immunize Balb/c mice by intraperitoneal injection and four hybridoma cell lines, which secreted monoclonal antibody(mAb) against human cTnI, were obtained by cell fusion, identification and cloning twice. Three mAbs(9F5, 2F11, 8C12) were produced from the ascites of Balb/c mice injected intraperitoneally the hybridoma cells and characterized by means of a surface plasmon resonance(SPR) biosensor. An optimal and specific sensing membrane for troponin I was prepared with staphylococcal protein A(SPA) as the intermediate layer and mAb against human cTnI as the capture antibody. On the basis of the sensing membrane, two modes of operation of the SPR biosensor were developed, i.e ., a direct detection of antigen antibody affinity and a sandwich assay. In the sandwich assay detection mode, the mAbs competition was measured by monitoring whether the secondary antibody had been attached to the cTnI already captured by the first antibody on the sensor surface. The SPR biosensor was shown to be able to directly detect the antigen antibody affinity and the order of the affinity was found to be 9F5>2F11>8C12. In the sandwich detection mode, it was found that the different epitopes on the cTnI molecules were recognized by the three mAbs respectively, but the asymmetrical competition was shown between 2F11 and 8C12 and no competition was found between 9F5 and 2F11 or 8c12. Based on these results, a double monoclonal sandwich immunoassay for cTnI was developed by using the optimal antibody pair of 9F5 and 2F11 and the SPR biosensor with SPA substrate membrane, which showed an excellent sensitivity of 0.8 μg/L for both the buffer and the serum samples compared with the direct detection of cTnI for the buffer with the lowest detection limit of 4 μg/L and conventional ELISA with the sensitivity of 1.9 μg/L. 展开更多
关键词 Troponin I Monoclonal antibodies CHARACTERIZATION SPR biosensor
下载PDF
Hydrogen peroxide biosensor based on electrodeposition of zinc oxide nanoflowers onto carbon nanotubes film electrode 被引量:4
15
作者 Hui Ping Bai Xu Xiao Lu Guang Ming Yang Yun Hui Yang 《Chinese Chemical Letters》 SCIE CAS CSCD 2008年第3期314-318,共5页
A new amperometric biosensor for hydrogen peroxide was developed based on adsorption of horseradish peroxidase at the glassy carbon electrode modified with zinc oxide nanoflowers produced by electrodeposition onto mul... A new amperometric biosensor for hydrogen peroxide was developed based on adsorption of horseradish peroxidase at the glassy carbon electrode modified with zinc oxide nanoflowers produced by electrodeposition onto multi-walled carbon nanotubes (MWNTs) film. The morphology of the MWNTs/nano-ZnO electrode has been investigated by scanning electron microscopy (SEM), and the electrochemical performance of the electrode has also been studied by amperometric method. The resulting electrode offered an excellent detection for hydrogen peroxide at -0.11 V with a linear response range of 9.9×10^-7 to 2.9×10^-3 mol/L with a correlation coefficient of 0.991, and response time 〈5 s. The biosensor displays rapid response and expanded linear response range, and excellent stability. 展开更多
关键词 Multi-walled carbon nanotubes biosensor ELECTRODEPOSITION Horseradish peroxidase ZnO nanoflowers
下载PDF
Non-enzymatic Glucose Biosensor Based on Cu/SWNTs Composite Film Fabricated by One-step Electrodeposition 被引量:3
16
作者 SUN Fang LIU Peng +1 位作者 LI Li LIAN Yong-fu 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2011年第6期1049-1054,共6页
Based on the adsorption of copper ions on single-walled carbon nanotubes(SWNTs) in electrolyte, Cu/SWNTs nanocomposite film was initially prepared on indium-doped tin oxide(ITO) substrate by one-step electrodeposi... Based on the adsorption of copper ions on single-walled carbon nanotubes(SWNTs) in electrolyte, Cu/SWNTs nanocomposite film was initially prepared on indium-doped tin oxide(ITO) substrate by one-step electrodeposition. This method may provide a versatile and facile pathway to fabricate other SWNTs-supported metal composite films. Electrochemical experiments revealed that the obtained Cu/SWNTs/ITO electrode offered an excellent electrocatalytic activity towards the oxidation of glucose and could be applied to the construction of non-enzymatic glucose biosensor. The linear range of the sensor was 1.0×10–6 to 6.0×10–4 mol/L and the response time was within 2 s. Particularly, its sensitivity reached as high as 1434.67 μA?L?mmol–1?cm–2, which was superior to any other non-enzymatic glucose biosensor based on copper-carbon nanotubes electrode reported previously. 展开更多
关键词 Carbon nanotube COPPER Nanocomposite film Glucose biosensor
下载PDF
Attachment of tyrosinase on mixed self-assembled monolayers for the construction of electrochemical biosensor 被引量:2
17
作者 Xue Ping Ji Xian Rui Li Na Wang Rui Xing Ni Xiao Hong Liu Hua Ai Xiong 《Chinese Chemical Letters》 SCIE CAS CSCD 2010年第10期1239-1242,共4页
A mixed self-assembled monolayers (SAMs) of thioctic acid (T-COOH) and thioctic acid amide (T-NH2) were used to immobilize tyrosinase for fabricating biosensor. The results showed that the mixed SAMs prepared fr... A mixed self-assembled monolayers (SAMs) of thioctic acid (T-COOH) and thioctic acid amide (T-NH2) were used to immobilize tyrosinase for fabricating biosensor. The results showed that the mixed SAMs prepared from solution at the ratio of 1:4 provided an excellent microenvironment for enzymatic reaction between tyrosinase and substrate. The biosensor exhibited a fast response and high sensitivity for sensing substrate. 展开更多
关键词 biosensor TYROSINASE CATECHOL Self-assembled monolayers Gold electrode
下载PDF
Biosensors for hepatitis B virus detection 被引量:2
18
作者 Chun-Yan Yao Wei-Ling Fu 《World Journal of Gastroenterology》 SCIE CAS 2014年第35期12485-12492,共8页
A biosensor is an analytical device used for the detection of analytes,which combines a biological component with a physicochemical detector.Recently,an increasing number of biosensors have been used in clinical resea... A biosensor is an analytical device used for the detection of analytes,which combines a biological component with a physicochemical detector.Recently,an increasing number of biosensors have been used in clinical research,for example,the blood glucose biosensor.This review focuses on the current state of biosensor research with respect to efficient,specific and rapid detection of hepatitis B virus(HBV).The biosensors developed based on different techniques,including optical methods(e.g.,surface plasmon resonance),acoustic wave technologies(e.g.,quartz crystal microbalance),electrochemistry(amperometry,voltammetry and impedance) and novel nanotechnology,are also discussed. 展开更多
关键词 biosensor Hepatitis B virus DIAGNOSIS DETECTION Quartz crystal microbalance
下载PDF
A Novel Biosensor for the Rapid Determination of Biochemical Oxygen Demand 被引量:2
19
作者 JIN-SONG CHEN LI-SHENG ZHANG JIAN-LONG WANG 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2007年第1期78-83,共6页
Objective To investigate the function of a novel biosensor used for the rapid determination of biochemical oxygen demand (BOD) which is developed by our research group based on suspended immobilized microbial cell s... Objective To investigate the function of a novel biosensor used for the rapid determination of biochemical oxygen demand (BOD) which is developed by our research group based on suspended immobilized microbial cell system in a completely mixed determining chamber as a substitute of the traditional membrane system. Methods Activated sludge was immobilized by PVA gel and used as a bio-sensing element. The novel biosensor was used to measure the short time BOD value and the conventional cultivation method was used for BOD5 measurement. Results A linear relationship was observed for the difference between the current and the concentration of glucose-glutamic acid (GGA) solution below 200 mg/L with a correlation coefficient of 0.995. The optimal response of the sensor was obtained at pH 7.0 and 30℃. The sensor response was within 15 min and was reproducible within ±5% of the mean in a series of eight samples containing 75 mg/L BOD using standard GGA solution. The novel sensor response was found to be fairly constant over a period of 30 days, with ±5% fluctuations. Conclusion A relatively good agreement is found between BOD estimated by the novel BOD biosensor and that determined by the conventional 5-day BOD method. This novel BOD biosensor has good sensitivity, stability and reproducibility. 展开更多
关键词 BOD BOD biosensor WASTEWATER Water quality Water pollution
下载PDF
A Novel Cholesterol Oxidase Biosensor Based on Pt-nanoparticle/Carbon Nanotube Modified Electrode 被引量:2
20
作者 Qiao Cui SHI Tu Zhi PENG 《Chinese Chemical Letters》 SCIE CAS CSCD 2005年第8期1081-1084,共4页
A Pt-nanooarticle/carbon nanotube modified graphite electrode immobilized with cholesterol oxidase/sol'-gel layer was developed for monitoring cholesterol.Using this electrode,cholesterol concentration(4.0×10^-... A Pt-nanooarticle/carbon nanotube modified graphite electrode immobilized with cholesterol oxidase/sol'-gel layer was developed for monitoring cholesterol.Using this electrode,cholesterol concentration(4.0×10^-6 tp 1.0×10^-4mol/L)could be determined accurately in the presence of ascorbic or uric acid,and the response time was rapid (〈 20 s). This biosensor has high sensitivity and selectivity. 展开更多
关键词 Pt- nanoparticle carbon nanotube cholesterol oxidase biosensor.
下载PDF
上一页 1 2 215 下一页 到第
使用帮助 返回顶部