Conventional blood sampling for glucose detection is prone to cause pain and fails to continuously record glucose fluctuations in vivo.Continuous glucose monitoring based on implantable electrodes could induce pain an...Conventional blood sampling for glucose detection is prone to cause pain and fails to continuously record glucose fluctuations in vivo.Continuous glucose monitoring based on implantable electrodes could induce pain and potential tissue inflammation,and the presence of reactive oxygen species(ROS)due to inflammationmay affect glucose detection.Microneedle technology is less invasive,yet microneedle adhesion with skin tissue is limited.In this work,we developed a microarrow sensor array(MASA),which provided enhanced skin surface adhesion and enabled simultaneous detection of glucose and H_(2)O_(2)(representative of ROS)in interstitial fluid in vivo.The microarrows fabricated via laser micromachining were modified with functional coating and integrated into a patch of a three-dimensional(3D)microneedle array.Due to the arrow tip mechanically interlocking with the tissue,the microarrow array could better adhere to the skin surface after penetration into skin.The MASA was demonstrated to provide continuous in vivo monitoring of glucose and H_(2)O_(2) concentrations,with the detection of H_(2)O_(2) providing a valuable reference for assessing the inflammation state.Finally,the MASA was integrated into a monitoring system using custom circuitry.This work provides a promising tool for the stable and reliable monitoring of blood glucose in diabetic patients.展开更多
In Fukushima Daiichi Nuclear Power Plant (FDNPP) accident, the fuel debris formed in the Reactor Pressure Vessel (RPV) and Primary Containment Vessel (PCV) at Unit 1</span><span style="font-family:Verdan...In Fukushima Daiichi Nuclear Power Plant (FDNPP) accident, the fuel debris formed in the Reactor Pressure Vessel (RPV) and Primary Containment Vessel (PCV) at Unit 1</span><span style="font-family:Verdana;"> </span><span style="font-family:Verdana;">-</span><span style="font-family:Verdana;"> </span><span style="font-family:Verdana;">3. To accelerate and decide further decommissioning steps of the FDNPP, it is crucial to obtain realistic information of the debris and localize contaminated water leakage from PCV. Due to high radiation and dark environment inside the PCV, investigating instruments and techniques should necessarily to meet specification of radiation resistance, waterproofness, dust resistance and so on. This study focuses on development of ultrasonic measurement system using a couple of sectorial array sensors to localize contaminated water leakage and visualize shape of object that repre</span><span style="font-family:Verdana;">- </span><span style="font-family:Verdana;">senting fuel debris, simultaneously. In this study, Total Focusing Method</span><span style="font-family:Verdana;"> (TFM) and Ultrasonic Velocity Profiler (UVP) methods are considered to visualize object shape and flow pattern around it, respectively. To demonstrate applicability and reliability of developed measurement system with sectorial array sensors, a mock-up experiment result</span><span style="font-family:Verdana;"> </span><span style="font-family:Verdana;">of simulated water leakage and fuel debris shape were discussed in this paper.展开更多
Novel potassium ion selective electrodes (K^+ISEs) and cDNA array sensors based on porous silicon (PS) have been developed.The calibration curve for the K^+ISEs is linear within a wide range of pK=2.0~6.0 with the sl...Novel potassium ion selective electrodes (K^+ISEs) and cDNA array sensors based on porous silicon (PS) have been developed.The calibration curve for the K^+ISEs is linear within a wide range of pK=2.0~6.0 with the slope of 56 mV per decade,which is near Nernst response.The response time and detection limit are within 31 s and 0.5μmol/L,respectively.The selective coefficient for Na^+ is-3.8,satisfies the requirement for the assay of blood potassium.The response variation is within 2 mV during 2 months.The binding capacity,the dynamic range and the detection limit of the DNA sensors were improved by replacing glass slide with PS substrates.The cDNA array sensors can bear 80℃of high temperature,75% of humidity,3.6 kLx of irradiation and keep stable within 10 days when they are exposed in air.Good performances of the K^+ISE and the cDNA array sensor are attributed to the large internal surface area and the easily modified microstructure of PS.展开更多
The full-field multiaxial strain measurement is highly desired for application of structural monitoring but still challenging,especially when the manufacturing and assembling for largearea sensing devices is quite dif...The full-field multiaxial strain measurement is highly desired for application of structural monitoring but still challenging,especially when the manufacturing and assembling for largearea sensing devices is quite difficult.Compared with the traditional procedure of gluing commercial strain gauges on the structure surfaces for strain monitoring,the recently developed Direct-Ink-Writing(DIW)technology provides a feasible way to directly print sensors on the structure.However,there are still crucial issues in the design and printing strategies to be probed and improved.Therefore,in this work,we propose an integrated strategy from layered circuit scheme to rapid manufacturing of strain rosette sensor array based on the DIW technology.Benefit from the innovative design with simplified circuit layout and the advantages of DIW for printing multilayer structures,here we achieve optimization design principle for strain rosette sensor array with scalable circuit layout,which enable a hierarchical printing strategy for multiaxial strain monitoring in large scale or multiple domains.The strategy is highly expected to adapt for the emerging requirement in various applications such as integrated soft electronics,nondestructive testing and small-batch medical devices.展开更多
The increasing morbidity of internal diseases poses serious threats to human health and quality of life.Exhaled breath analysis is a noninvasive and convenient diagnostic method to improve the cure rate of patients. I...The increasing morbidity of internal diseases poses serious threats to human health and quality of life.Exhaled breath analysis is a noninvasive and convenient diagnostic method to improve the cure rate of patients. In this study, a self-powered breath analyzer based on polyaniline/polyvinylidene fluoride(PANI/PVDF) piezogas-sensing arrays has been developed for potential detection of several internal diseases. The device works by converting exhaled breath energy into piezoelectric gassensing signals without any external power sources. The five sensing units in the device have different sensitivities to various gas markers with concentrations ranging from 0 to 600 ppm. The working principle can be attributed to the coupling of the in-pipe gas-flow-induced piezoelectric effect of PVDF and gas-sensing properties of PANI electrodes. In addition, the device demonstrates its use as an ethanol analyzer to roughly mimic fatty liver diagnosis.This new approach can be applied to fabricating new exhaled breath analyzers and promoting the development of self-powered systems.展开更多
Acoustic array sensor device for partial discharge detection is widely used in power equipment inspection with the advantages of non-contact and precise positioning compared with partial discharge detection methods su...Acoustic array sensor device for partial discharge detection is widely used in power equipment inspection with the advantages of non-contact and precise positioning compared with partial discharge detection methods such as ultrasonic method and pulse current method.However,due to the sensitivity of the acoustic array sensor and the influence of the equipment operation site interference,the acoustic array sensor device for partial discharge type diagnosis by phase resolved partial discharge(PRPD)map might occasionally presents incorrect results,thus affecting the power equipment operation and maintenance strategy.The acoustic array sensor detection device for power equipment developed in this paper applies the array design model of equal-area multi-arm spiral with machine learning fast fourier transform clean(FFT-CLEAN)sound source localization identification algorithm to avoid the interference factors in the noise acquisition system using a single microphone and conventional beam forming algorithm,improves the spatial resolution of the acoustic array sensor device,and proposes an acoustic array sensor device based on the acoustic spectrogram.The analysis and diagnosis method of discharge type of acoustic array sensor device can effectively reduce the system misjudgment caused by factors such as the resolution of the acoustic imaging device and the time domain pulse of the digital signal,and reduce the false alarm rate of the acoustic array sensor device.The proposed method is tested by selecting power cables as the object,and its effectiveness is proved by laboratory verification and field verification.展开更多
A data acquisition system for testing gas sensor array response to multi-gas is presented.The testing system is based on the character of the gas response of metal oxide semiconductor gas sensor array.The data acquisi...A data acquisition system for testing gas sensor array response to multi-gas is presented.The testing system is based on the character of the gas response of metal oxide semiconductor gas sensor array.The data acquisition is realized automatically through the real time controlling of the data acquisition card PCI1711.This system is highly attractive for electronic nose,which is a powerful tool for the discrimination of gases.展开更多
In the present work, an experimental study of bubbly two-phase flow in a rectangular bubble column was performed using two ultrasonic array sensors, which can measure the instantaneous velocity of gas bubbles on multi...In the present work, an experimental study of bubbly two-phase flow in a rectangular bubble column was performed using two ultrasonic array sensors, which can measure the instantaneous velocity of gas bubbles on multiple measurement lines. After the sound pressure distribution of sensors had been evaluated with a needle hydrophone technique, the array sensors were applied to two-phase bubble col- umn, To assess the accuracy of the measurement system with array sensors for one and two-dimensional velocity, a simultaneous measurement was performed with an optical measurement technique called particle image velocimetry (PIV). Experimental results showed that accuracy of the measurement system with array sensors is under 10% for one-dimensional velocity profile measurement compared with PIV technique. The accuracy of the system was estimated to be under 20% along the mean flow direction in the case of two-dimensional vector mapping.展开更多
The passive acoustic localization with planar sensor array is introduced. Based on a method to eliminate the influence of effective sound velocity in passive detection, a new five-sensors solid array and its localizat...The passive acoustic localization with planar sensor array is introduced. Based on a method to eliminate the influence of effective sound velocity in passive detection, a new five-sensors solid array and its localization model are put forward. The factors that influence the precision of the localization are analyzed. Considering the errors from the factors synchronously, the simulation compares the solid array with the planar array. It can be proved that the five-sensor solid array is better than the four-sensor planar array in the estimation of bearing elements.展开更多
Pipelines are one of the most important modern energy transportation methods,used especially for the transportation of certain dangerous energy media materials such as crude oil,natural gas,and chemical raw materials....Pipelines are one of the most important modern energy transportation methods,used especially for the transportation of certain dangerous energy media materials such as crude oil,natural gas,and chemical raw materials.New requirements have been put forward for the health monitoring and early security warning of pipelines because of the large-scale and complicated development trend of the pipe network system.To achieve an accurate assessment of the health conditions of pipeline infrastructure,obtaining as many precise operating parameters as possible,particularly at some critical parts of the pipeline,is necessary.Therefore,a novel type of fiber grating strain sensor array is proposed herein to monitor the pipeline hoop strain.The sensor utilizes fiber grating characteristics such as light weight,corrosion resistance,remote transmission,and strong environmental adaptability.The fiber containing the grating measurement points is implanted into the composite material to complete the sensitization encapsulation and protection of the bare fiber grating.The design of the sensor array fulfills the requirements for monitoring pipeline mass data,making it easy to form a pipeline health monitoring sensor network.The sensor sensitivity is researched by using a combination of theoretical and experimental analysis.A sensitivity test,as well as linearity and stability tests,are performed on the sensor.The experimental results show that the average sensitivity of the sensor is 14.86 pm/με,and the error from the theoretical calculation analysis value is 8.75%.Due to its high reliability,good linear response and long-term stability,and the ability to reflect the exact strain change of the outer wall of the pipeline,the designed sensor can support longterm online pipeline monitoring.The fiber grating sensor array network has successfully realized the monitoring of the pipeline’s internal operation by using external strain changes.In addition to the performance benefits,there are other merits associated with the applicability of the sensor namely simple structure,compact size,manufacturing ease,and exterior installation ease.展开更多
This paper presents a low?complexity method for the direction?of?arrival(DOA)estimation of noncircular signals for coprime sensor arrays.The noncircular property is exploited to improve the performance of DOA estimati...This paper presents a low?complexity method for the direction?of?arrival(DOA)estimation of noncircular signals for coprime sensor arrays.The noncircular property is exploited to improve the performance of DOA estimation.To reduce the computational complexity,the rotational invariance propagator method(RIPM)is included in the algorithm.First,the extended array output is reconstructed by combining the array output and its conjugated counterpart.Then,the RIPM is utilized to obtain two sets of DOA estimates for two subarrays.Finally,the true DOAs are estimated by combining the consistent results of the two subarrays.This illustrates the potential gain that both noncircularity and coprime arrays provide when considered together.The proposed algorithm has a lower computational complexity and a better DOA estimation performance than the standard estimation of signal parameters by the rotational invariance technique and Capon algorithm.Numerical simulation results illustrate the effectiveness and superiority of the proposed algorithm.展开更多
In the presence of background noise,arrival times picked from a surface microseismic data set usually include a number of false picks that can lead to uncertainty in location estimation.To eliminate false picks and im...In the presence of background noise,arrival times picked from a surface microseismic data set usually include a number of false picks that can lead to uncertainty in location estimation.To eliminate false picks and improve the accuracy of location estimates,we develop an association algorithm termed RANSAC-based Arrival Time Event Clustering(RATEC)that clusters picked arrival times into event groups based on random sampling and fitting moveout curves that approximate hyperbolas.Arrival times far from the fitted hyperbolas are classified as false picks and removed from the data set prior to location estimation.Simulations of synthetic data for a 1-D linear array show that RATEC is robust under different noise conditions and generally applicable to various types of subsurface structures.By generalizing the underlying moveout model,RATEC is extended to the case of a 2-D surface monitoring array.The effectiveness of event location for the 2-D case is demonstrated using a data set collected by the 5200-element dense Long Beach array.The obtained results suggest that RATEC is effective in removing false picks and hence can be used for phase association before location estimates.展开更多
The past several decades have witnessed great progress in high-performance field effect transistors(FET)as one of the most important electronic compo-nents.At the same time,due to their intrinsic advantages,such as mu...The past several decades have witnessed great progress in high-performance field effect transistors(FET)as one of the most important electronic compo-nents.At the same time,due to their intrinsic advantages,such as multiparameter accessibility,excellent electric signal amplification function,and ease of large-scale manufacturing,FET as tactile sensors for flexible wear-able devices,artificial intelligence,Internet of Things,and other fields to per-ceive external stimuli has also attracted great attention and become a significant field of general concern.More importantly,FET has a unique three-terminal structure,which enables its different components to detect external mechanics through different sensing mechanisms.On one hand,it provides an important platform to shed deep insights into the underlying mechanisms of the tactile sensors.On the other hand,these properties could in turn endow excellent components for the construction of tactile matrix sensor arrays with high quality.With special emphasis on the configuration of FETs,this review classified and summarized structure-optimized FET tactile sensors with gate,dielectric layer,semiconductor layer,and source/drain electrodes as sensing active components,respectively.The working principles and the state-of-the-art protocols in terms of high-performance tactile sensors are detail discussed and highlighted,the innovative pixel distribution and integration analysis of the transistor sensor matrix array concerning flexible electronics are also intro-duced.We hope that the introduction of this review can provide some inspiration for future researchers to design and fabricate high-performance FET-based tactile sensor chips for flexible electronics and other fields.展开更多
Technology-assisted ball training systems have become a research hotspot due to their ability to provide quantitative data for guiding athletes to address their areas of improvement.However,traditional tennis training...Technology-assisted ball training systems have become a research hotspot due to their ability to provide quantitative data for guiding athletes to address their areas of improvement.However,traditional tennis training systems still have some limitations;for instance,they are subjective,expensive,heavy,and time-consuming.In this research,an assistant training tennis racket,which consists of arrayed flexible sensors and an inertial measurement unit,has been proposed to comprehensively analyze the representative actions’force and acceleration.Consisting of MXene as the sensitive material and melamine sponge as the substrate(named MMSS),the flexible sensor exhibited an excellent sensitivity of 5.35 kPa^(-1)(1.1-22.2 kPa)due to the formation of a 3D conductive network.Moreover,the sensor retained a high sensitivity of 0.6 k Pa-1in an ultrawide measurement range(22.2-266 kPa).In addition to recognizing the type of hitting action,an artificial intelligence algorithm was introduced to accurately differentiate the five typical motion behaviors with an accuracy rate of 98.2%.This study not only proposes a comprehensive assistant training tennis racket for improving the techniques of tennis enthusiasts but also a new information processing scheme for intelligent sensing and distinction of different movements,which can offer significant application potential in sports big data collection and the Internet of things.展开更多
A novel portable instrument developed for field determinations of complex mixtures of volatile organic compounds (VOCs) is described.The key features of the instrument are a miniature multi-stage adsorbent preconcentr...A novel portable instrument developed for field determinations of complex mixtures of volatile organic compounds (VOCs) is described.The key features of the instrument are a miniature multi-stage adsorbent preconcentrator/focuser,two series-coupled separation columns with pressure and temperature tunable retention control,and an integrated array of four chemiresistor (CR) sensors coated with Au-thiolate monolayer-protected nanoparticles (MPN).MPN-CR array response patterns are used with retention times to identify eluting vapors.Air is used as the carrier gas.Calibrations of 20 common indoor air contaminants gave LODs in the range of 0.05 ng/g~0.53 ng/g for a 1 L sample volume.Results of preliminary analyses of characteristic VOCs generated from U.S.currency as well as vapor-phase markers of environmental tobacco smoke (ETS) at low-or sub-ng/g levels are presented.展开更多
The light-addressable potentiometric sensor (LAPS) is a semiconductor-based cellular biosensor with an electrolyte-insulator-semiconductor (EIS) structure.By depositing biocompatible layers on the sensing surface fo...The light-addressable potentiometric sensor (LAPS) is a semiconductor-based cellular biosensor with an electrolyte-insulator-semiconductor (EIS) structure.By depositing biocompatible layers on the sensing surface for cell culture, it can be used to detect bioelectrical parameters of cells.The characteristic curve for photocurrent versus applied bias voltage to the system shows a current-voltage curve (Ⅰ-Ⅴcurve).This technique can be used to detect the action potential changes towards different drugs based on the bias voltage dependence of an optical current,and provides a dynamic system by scanning light beam at the very cell on the sensor device.The LAPS overcomes the limitation of recording sites,but high spatial resolution and sensitivity are also paramount.This paper discussed a novel structure of LAPS array for extracellular monitoring to decrease potential noise level.Both characteristics of active recording array areas and cell culture conditions are measured.展开更多
A novel method based on independent component analyzing (ICA) in frequency domain to distinguish the frequency characteristics of multi-sensor system is presented. The conditions of this type of ICA are considered and...A novel method based on independent component analyzing (ICA) in frequency domain to distinguish the frequency characteristics of multi-sensor system is presented. The conditions of this type of ICA are considered and each step of resolving the problem is discussed. For a two gas sensor array, the frequency characteristics including amplitude-frequency and phase-frequency are recognized by this method, and cross-sensitivity between them is also eliminated. From the principle of similarity, the recognition mean square error is no more than 0.085.展开更多
Spot welding is affected by many factors and is difficult to monitor the nugget information with single sensor. In this paper, a new monitor system based on sensors array technique was developed for spot welding quali...Spot welding is affected by many factors and is difficult to monitor the nugget information with single sensor. In this paper, a new monitor system based on sensors array technique was developed for spot welding quality detection. The key part in the system is cross magnetic sensor array. It is composed of six magnetic sensors. An improved algorithm was proposed to extract the signal eigenvalue, which was based on principle component analysis. The results show that in the case of the 60 mm experiment, cross magnetic sensor array works well. And when the eigenvalues range of the cross magnetic sensor array is 0. 090 1 - 0. 098 2, the spots quality is good. The analysis of the eigenvalues of the cross magnetic sensor array allows us to determine whether the spot qualty is good or bad.展开更多
Recently,the possibility of a disaster due to the improper use of highly toxic gases which are known as agents throughout the world has been increased.Therefore,the development of technology for countermeasure against...Recently,the possibility of a disaster due to the improper use of highly toxic gases which are known as agents throughout the world has been increased.Therefore,the development of technology for countermeasure against CWA has been highly demanded.In this study,thick film SnO_2-based gas sensing devices were prepared and the sensing properties for the four different kinds of simulants such as dimethyl methyl phosphonate (DMMP),acetonitrile,dichloromethane and dipropylene glycol methyl ether have been investigated.And a micro sensor array consists of six devices was prepared using MEMS technology to provide high selective and reliable sensing system for the detection of chemical warfare agents.The micro gas sensor array prepared showed good sensitivity and selectivity to CWA.展开更多
This paper examines the direction of arrival(DOA)estimation for polarized signals impinging on a sparse vector sensor array which is based on the maximum interelement spacing constraint(MISC).The vector array effectiv...This paper examines the direction of arrival(DOA)estimation for polarized signals impinging on a sparse vector sensor array which is based on the maximum interelement spacing constraint(MISC).The vector array effectively utilizes the polarization domain information of incident signals,and the quaternion model is adopted for signals polarization characteristic maintenance and computational burden reduction.The features of MISC arrays are crucial to the mutual coupling effects reduction and higher degrees of freedom(DOFs).The quaternion data model based on vector MISC arrays is established,which extends the scalar MISC array into the vector MISC array.Based on the model,a quaternion multiple signal classification(MUSIC)algorithm based on vector MISC arrays is proposed for DOA estimation.The algorithm combines the advantages of the quaternion model and the vector MISC array to enhance the DOA estimation performance.Analytical simulations are performed to certify the capability of the algorithm.展开更多
基金This work was financially supported by the National Key R&D Program of China(Nos.2021YFF1200700 and 2021YFA0911100)the National Natural Science Foundation of China(Nos.32171399,32171456,and T2225010)+6 种基金the Guangdong Basic and Applied Basic Research Foundation(No.2021A1515012261)the Science and Technology Program of Guangzhou,China(No.202103000076)the Fundamental Research Funds for the Central Universities,Sun Yat-Sen University(No.22dfx02),and Pazhou Lab,Guangzhou(No.PZL2021KF0003)FML would like to thank the National Natural Science Foundation of China(Nos.32171335 and 31900954)JL would like to thank the National Natural Science Foundation of China(No.62105380)the China Postdoctoral Science Foundation(No.2021M693686)QQOY would like to thank the China Postdoctoral Science Foundation(No.2022M713645).
文摘Conventional blood sampling for glucose detection is prone to cause pain and fails to continuously record glucose fluctuations in vivo.Continuous glucose monitoring based on implantable electrodes could induce pain and potential tissue inflammation,and the presence of reactive oxygen species(ROS)due to inflammationmay affect glucose detection.Microneedle technology is less invasive,yet microneedle adhesion with skin tissue is limited.In this work,we developed a microarrow sensor array(MASA),which provided enhanced skin surface adhesion and enabled simultaneous detection of glucose and H_(2)O_(2)(representative of ROS)in interstitial fluid in vivo.The microarrows fabricated via laser micromachining were modified with functional coating and integrated into a patch of a three-dimensional(3D)microneedle array.Due to the arrow tip mechanically interlocking with the tissue,the microarrow array could better adhere to the skin surface after penetration into skin.The MASA was demonstrated to provide continuous in vivo monitoring of glucose and H_(2)O_(2) concentrations,with the detection of H_(2)O_(2) providing a valuable reference for assessing the inflammation state.Finally,the MASA was integrated into a monitoring system using custom circuitry.This work provides a promising tool for the stable and reliable monitoring of blood glucose in diabetic patients.
文摘In Fukushima Daiichi Nuclear Power Plant (FDNPP) accident, the fuel debris formed in the Reactor Pressure Vessel (RPV) and Primary Containment Vessel (PCV) at Unit 1</span><span style="font-family:Verdana;"> </span><span style="font-family:Verdana;">-</span><span style="font-family:Verdana;"> </span><span style="font-family:Verdana;">3. To accelerate and decide further decommissioning steps of the FDNPP, it is crucial to obtain realistic information of the debris and localize contaminated water leakage from PCV. Due to high radiation and dark environment inside the PCV, investigating instruments and techniques should necessarily to meet specification of radiation resistance, waterproofness, dust resistance and so on. This study focuses on development of ultrasonic measurement system using a couple of sectorial array sensors to localize contaminated water leakage and visualize shape of object that repre</span><span style="font-family:Verdana;">- </span><span style="font-family:Verdana;">senting fuel debris, simultaneously. In this study, Total Focusing Method</span><span style="font-family:Verdana;"> (TFM) and Ultrasonic Velocity Profiler (UVP) methods are considered to visualize object shape and flow pattern around it, respectively. To demonstrate applicability and reliability of developed measurement system with sectorial array sensors, a mock-up experiment result</span><span style="font-family:Verdana;"> </span><span style="font-family:Verdana;">of simulated water leakage and fuel debris shape were discussed in this paper.
基金supported by National Natural Science Foundation of China(69925409,60276036)Shanghai Applied Material Foundation(0202).
文摘Novel potassium ion selective electrodes (K^+ISEs) and cDNA array sensors based on porous silicon (PS) have been developed.The calibration curve for the K^+ISEs is linear within a wide range of pK=2.0~6.0 with the slope of 56 mV per decade,which is near Nernst response.The response time and detection limit are within 31 s and 0.5μmol/L,respectively.The selective coefficient for Na^+ is-3.8,satisfies the requirement for the assay of blood potassium.The response variation is within 2 mV during 2 months.The binding capacity,the dynamic range and the detection limit of the DNA sensors were improved by replacing glass slide with PS substrates.The cDNA array sensors can bear 80℃of high temperature,75% of humidity,3.6 kLx of irradiation and keep stable within 10 days when they are exposed in air.Good performances of the K^+ISE and the cDNA array sensor are attributed to the large internal surface area and the easily modified microstructure of PS.
基金Supported by National Natural Science Foundation of China(Grant No.11972171)the Sixth Phase of Jiangsu Province“333 High Level Talent Training Project”Second Level Talents,Jiangsu Provincial Natural Science Foundation of China(Grant No.BK20180031)+2 种基金State Key Laboratory of Mechanics and Control of Mechanical Structures,Nanjing University of Aeronautics and Astronautics of China(Grant No.MCMS-E-0422G04)Open Fund of Key Laboratory for Intelligent Nano Materials and Devices of the Ministry of Education NJ2020003(Grant No.INMD-2021M05)111 Project(Grant No.B18027).
文摘The full-field multiaxial strain measurement is highly desired for application of structural monitoring but still challenging,especially when the manufacturing and assembling for largearea sensing devices is quite difficult.Compared with the traditional procedure of gluing commercial strain gauges on the structure surfaces for strain monitoring,the recently developed Direct-Ink-Writing(DIW)technology provides a feasible way to directly print sensors on the structure.However,there are still crucial issues in the design and printing strategies to be probed and improved.Therefore,in this work,we propose an integrated strategy from layered circuit scheme to rapid manufacturing of strain rosette sensor array based on the DIW technology.Benefit from the innovative design with simplified circuit layout and the advantages of DIW for printing multilayer structures,here we achieve optimization design principle for strain rosette sensor array with scalable circuit layout,which enable a hierarchical printing strategy for multiaxial strain monitoring in large scale or multiple domains.The strategy is highly expected to adapt for the emerging requirement in various applications such as integrated soft electronics,nondestructive testing and small-batch medical devices.
基金supported by the National Natural Science Foundation of China (11674048)the Fundamental Research Funds for the Central Universities (N170505001 and N160502002)Program for Shenyang Youth Science and Technology Innovation Talents (RC170269)
文摘The increasing morbidity of internal diseases poses serious threats to human health and quality of life.Exhaled breath analysis is a noninvasive and convenient diagnostic method to improve the cure rate of patients. In this study, a self-powered breath analyzer based on polyaniline/polyvinylidene fluoride(PANI/PVDF) piezogas-sensing arrays has been developed for potential detection of several internal diseases. The device works by converting exhaled breath energy into piezoelectric gassensing signals without any external power sources. The five sensing units in the device have different sensitivities to various gas markers with concentrations ranging from 0 to 600 ppm. The working principle can be attributed to the coupling of the in-pipe gas-flow-induced piezoelectric effect of PVDF and gas-sensing properties of PANI electrodes. In addition, the device demonstrates its use as an ethanol analyzer to roughly mimic fatty liver diagnosis.This new approach can be applied to fabricating new exhaled breath analyzers and promoting the development of self-powered systems.
基金This work was supported by the science and technology project of State Grid Shanghai Municipal Electric Power Company(No.52090020007F)National Key R&D Program of China(2017YFB0902800).
文摘Acoustic array sensor device for partial discharge detection is widely used in power equipment inspection with the advantages of non-contact and precise positioning compared with partial discharge detection methods such as ultrasonic method and pulse current method.However,due to the sensitivity of the acoustic array sensor and the influence of the equipment operation site interference,the acoustic array sensor device for partial discharge type diagnosis by phase resolved partial discharge(PRPD)map might occasionally presents incorrect results,thus affecting the power equipment operation and maintenance strategy.The acoustic array sensor detection device for power equipment developed in this paper applies the array design model of equal-area multi-arm spiral with machine learning fast fourier transform clean(FFT-CLEAN)sound source localization identification algorithm to avoid the interference factors in the noise acquisition system using a single microphone and conventional beam forming algorithm,improves the spatial resolution of the acoustic array sensor device,and proposes an acoustic array sensor device based on the acoustic spectrogram.The analysis and diagnosis method of discharge type of acoustic array sensor device can effectively reduce the system misjudgment caused by factors such as the resolution of the acoustic imaging device and the time domain pulse of the digital signal,and reduce the false alarm rate of the acoustic array sensor device.The proposed method is tested by selecting power cables as the object,and its effectiveness is proved by laboratory verification and field verification.
文摘A data acquisition system for testing gas sensor array response to multi-gas is presented.The testing system is based on the character of the gas response of metal oxide semiconductor gas sensor array.The data acquisition is realized automatically through the real time controlling of the data acquisition card PCI1711.This system is highly attractive for electronic nose,which is a powerful tool for the discrimination of gases.
文摘In the present work, an experimental study of bubbly two-phase flow in a rectangular bubble column was performed using two ultrasonic array sensors, which can measure the instantaneous velocity of gas bubbles on multiple measurement lines. After the sound pressure distribution of sensors had been evaluated with a needle hydrophone technique, the array sensors were applied to two-phase bubble col- umn, To assess the accuracy of the measurement system with array sensors for one and two-dimensional velocity, a simultaneous measurement was performed with an optical measurement technique called particle image velocimetry (PIV). Experimental results showed that accuracy of the measurement system with array sensors is under 10% for one-dimensional velocity profile measurement compared with PIV technique. The accuracy of the system was estimated to be under 20% along the mean flow direction in the case of two-dimensional vector mapping.
文摘The passive acoustic localization with planar sensor array is introduced. Based on a method to eliminate the influence of effective sound velocity in passive detection, a new five-sensors solid array and its localization model are put forward. The factors that influence the precision of the localization are analyzed. Considering the errors from the factors synchronously, the simulation compares the solid array with the planar array. It can be proved that the five-sensor solid array is better than the four-sensor planar array in the estimation of bearing elements.
基金supported by the National Key R&D Program of China(Grants 2018YFF0214700)Hubei Province Science and Technology Special Major Project(2016AAA008)New Research and Development Agency Project of Zhongshan Science and Technology Bureau(2017F2FC003)in China.
文摘Pipelines are one of the most important modern energy transportation methods,used especially for the transportation of certain dangerous energy media materials such as crude oil,natural gas,and chemical raw materials.New requirements have been put forward for the health monitoring and early security warning of pipelines because of the large-scale and complicated development trend of the pipe network system.To achieve an accurate assessment of the health conditions of pipeline infrastructure,obtaining as many precise operating parameters as possible,particularly at some critical parts of the pipeline,is necessary.Therefore,a novel type of fiber grating strain sensor array is proposed herein to monitor the pipeline hoop strain.The sensor utilizes fiber grating characteristics such as light weight,corrosion resistance,remote transmission,and strong environmental adaptability.The fiber containing the grating measurement points is implanted into the composite material to complete the sensitization encapsulation and protection of the bare fiber grating.The design of the sensor array fulfills the requirements for monitoring pipeline mass data,making it easy to form a pipeline health monitoring sensor network.The sensor sensitivity is researched by using a combination of theoretical and experimental analysis.A sensitivity test,as well as linearity and stability tests,are performed on the sensor.The experimental results show that the average sensitivity of the sensor is 14.86 pm/με,and the error from the theoretical calculation analysis value is 8.75%.Due to its high reliability,good linear response and long-term stability,and the ability to reflect the exact strain change of the outer wall of the pipeline,the designed sensor can support longterm online pipeline monitoring.The fiber grating sensor array network has successfully realized the monitoring of the pipeline’s internal operation by using external strain changes.In addition to the performance benefits,there are other merits associated with the applicability of the sensor namely simple structure,compact size,manufacturing ease,and exterior installation ease.
基金supported by the National Natural Science Foundations of China (Nos.61371169,61601167, 61601504)the Natural Science Foundation of Jiangsu Province (No.BK20161489)+1 种基金the Open Research Fund of State Key Laboratory of Millimeter Waves, Southeast University (No. K201826)the Fundamental Research Funds for the Central Universities (No. NE2017103)
文摘This paper presents a low?complexity method for the direction?of?arrival(DOA)estimation of noncircular signals for coprime sensor arrays.The noncircular property is exploited to improve the performance of DOA estimation.To reduce the computational complexity,the rotational invariance propagator method(RIPM)is included in the algorithm.First,the extended array output is reconstructed by combining the array output and its conjugated counterpart.Then,the RIPM is utilized to obtain two sets of DOA estimates for two subarrays.Finally,the true DOAs are estimated by combining the consistent results of the two subarrays.This illustrates the potential gain that both noncircularity and coprime arrays provide when considered together.The proposed algorithm has a lower computational complexity and a better DOA estimation performance than the standard estimation of signal parameters by the rotational invariance technique and Capon algorithm.Numerical simulation results illustrate the effectiveness and superiority of the proposed algorithm.
文摘In the presence of background noise,arrival times picked from a surface microseismic data set usually include a number of false picks that can lead to uncertainty in location estimation.To eliminate false picks and improve the accuracy of location estimates,we develop an association algorithm termed RANSAC-based Arrival Time Event Clustering(RATEC)that clusters picked arrival times into event groups based on random sampling and fitting moveout curves that approximate hyperbolas.Arrival times far from the fitted hyperbolas are classified as false picks and removed from the data set prior to location estimation.Simulations of synthetic data for a 1-D linear array show that RATEC is robust under different noise conditions and generally applicable to various types of subsurface structures.By generalizing the underlying moveout model,RATEC is extended to the case of a 2-D surface monitoring array.The effectiveness of event location for the 2-D case is demonstrated using a data set collected by the 5200-element dense Long Beach array.The obtained results suggest that RATEC is effective in removing false picks and hence can be used for phase association before location estimates.
基金This work was supported by the National Natural Science Foundation of China(51902131)Natural Science Foun-dation of Shandong province(ZR2019BEM006)the Major Scientific and Technological Innovation Project of Shandong Province(2021CXGC010603).
文摘The past several decades have witnessed great progress in high-performance field effect transistors(FET)as one of the most important electronic compo-nents.At the same time,due to their intrinsic advantages,such as multiparameter accessibility,excellent electric signal amplification function,and ease of large-scale manufacturing,FET as tactile sensors for flexible wear-able devices,artificial intelligence,Internet of Things,and other fields to per-ceive external stimuli has also attracted great attention and become a significant field of general concern.More importantly,FET has a unique three-terminal structure,which enables its different components to detect external mechanics through different sensing mechanisms.On one hand,it provides an important platform to shed deep insights into the underlying mechanisms of the tactile sensors.On the other hand,these properties could in turn endow excellent components for the construction of tactile matrix sensor arrays with high quality.With special emphasis on the configuration of FETs,this review classified and summarized structure-optimized FET tactile sensors with gate,dielectric layer,semiconductor layer,and source/drain electrodes as sensing active components,respectively.The working principles and the state-of-the-art protocols in terms of high-performance tactile sensors are detail discussed and highlighted,the innovative pixel distribution and integration analysis of the transistor sensor matrix array concerning flexible electronics are also intro-duced.We hope that the introduction of this review can provide some inspiration for future researchers to design and fabricate high-performance FET-based tactile sensor chips for flexible electronics and other fields.
基金supported by the National Key R&D Program of China(Grant No.2019YFE0120300)the National Natural Science Foundation of China(Grant Nos.62171414,52175554,52205608,62001431)+1 种基金the Fundamental Research Program of Shanxi Province(Grant Nos.20210302123059,20210302124610)Program for the Innovative Talents of Higher Education Institutions of Shanxi。
文摘Technology-assisted ball training systems have become a research hotspot due to their ability to provide quantitative data for guiding athletes to address their areas of improvement.However,traditional tennis training systems still have some limitations;for instance,they are subjective,expensive,heavy,and time-consuming.In this research,an assistant training tennis racket,which consists of arrayed flexible sensors and an inertial measurement unit,has been proposed to comprehensively analyze the representative actions’force and acceleration.Consisting of MXene as the sensitive material and melamine sponge as the substrate(named MMSS),the flexible sensor exhibited an excellent sensitivity of 5.35 kPa^(-1)(1.1-22.2 kPa)due to the formation of a 3D conductive network.Moreover,the sensor retained a high sensitivity of 0.6 k Pa-1in an ultrawide measurement range(22.2-266 kPa).In addition to recognizing the type of hitting action,an artificial intelligence algorithm was introduced to accurately differentiate the five typical motion behaviors with an accuracy rate of 98.2%.This study not only proposes a comprehensive assistant training tennis racket for improving the techniques of tennis enthusiasts but also a new information processing scheme for intelligent sensing and distinction of different movements,which can offer significant application potential in sports big data collection and the Internet of things.
文摘A novel portable instrument developed for field determinations of complex mixtures of volatile organic compounds (VOCs) is described.The key features of the instrument are a miniature multi-stage adsorbent preconcentrator/focuser,two series-coupled separation columns with pressure and temperature tunable retention control,and an integrated array of four chemiresistor (CR) sensors coated with Au-thiolate monolayer-protected nanoparticles (MPN).MPN-CR array response patterns are used with retention times to identify eluting vapors.Air is used as the carrier gas.Calibrations of 20 common indoor air contaminants gave LODs in the range of 0.05 ng/g~0.53 ng/g for a 1 L sample volume.Results of preliminary analyses of characteristic VOCs generated from U.S.currency as well as vapor-phase markers of environmental tobacco smoke (ETS) at low-or sub-ng/g levels are presented.
基金This work was supported by the National Natural Science Foundation of China (Grant Nos. 30270387, No. 30570492);the Project of State Key Laboratory of Transducer Technology of China (Grant No. SKT0403);the Foundation for the Bureau of Zhejiang Province of China (Grant No. 20040197).
文摘The light-addressable potentiometric sensor (LAPS) is a semiconductor-based cellular biosensor with an electrolyte-insulator-semiconductor (EIS) structure.By depositing biocompatible layers on the sensing surface for cell culture, it can be used to detect bioelectrical parameters of cells.The characteristic curve for photocurrent versus applied bias voltage to the system shows a current-voltage curve (Ⅰ-Ⅴcurve).This technique can be used to detect the action potential changes towards different drugs based on the bias voltage dependence of an optical current,and provides a dynamic system by scanning light beam at the very cell on the sensor device.The LAPS overcomes the limitation of recording sites,but high spatial resolution and sensitivity are also paramount.This paper discussed a novel structure of LAPS array for extracellular monitoring to decrease potential noise level.Both characteristics of active recording array areas and cell culture conditions are measured.
基金This work was supported by the National Natural Science Foundation of China (No60276037)
文摘A novel method based on independent component analyzing (ICA) in frequency domain to distinguish the frequency characteristics of multi-sensor system is presented. The conditions of this type of ICA are considered and each step of resolving the problem is discussed. For a two gas sensor array, the frequency characteristics including amplitude-frequency and phase-frequency are recognized by this method, and cross-sensitivity between them is also eliminated. From the principle of similarity, the recognition mean square error is no more than 0.085.
基金This work was supported by Project of National 863 High Technology of China ( No. 2008AA04Z136 ), Project supported by the National Natural Science Foundation of China( No. 50975197).
文摘Spot welding is affected by many factors and is difficult to monitor the nugget information with single sensor. In this paper, a new monitor system based on sensors array technique was developed for spot welding quality detection. The key part in the system is cross magnetic sensor array. It is composed of six magnetic sensors. An improved algorithm was proposed to extract the signal eigenvalue, which was based on principle component analysis. The results show that in the case of the 60 mm experiment, cross magnetic sensor array works well. And when the eigenvalues range of the cross magnetic sensor array is 0. 090 1 - 0. 098 2, the spots quality is good. The analysis of the eigenvalues of the cross magnetic sensor array allows us to determine whether the spot qualty is good or bad.
文摘Recently,the possibility of a disaster due to the improper use of highly toxic gases which are known as agents throughout the world has been increased.Therefore,the development of technology for countermeasure against CWA has been highly demanded.In this study,thick film SnO_2-based gas sensing devices were prepared and the sensing properties for the four different kinds of simulants such as dimethyl methyl phosphonate (DMMP),acetonitrile,dichloromethane and dipropylene glycol methyl ether have been investigated.And a micro sensor array consists of six devices was prepared using MEMS technology to provide high selective and reliable sensing system for the detection of chemical warfare agents.The micro gas sensor array prepared showed good sensitivity and selectivity to CWA.
基金supported by the National Natural Science Foundation of China(62031015).
文摘This paper examines the direction of arrival(DOA)estimation for polarized signals impinging on a sparse vector sensor array which is based on the maximum interelement spacing constraint(MISC).The vector array effectively utilizes the polarization domain information of incident signals,and the quaternion model is adopted for signals polarization characteristic maintenance and computational burden reduction.The features of MISC arrays are crucial to the mutual coupling effects reduction and higher degrees of freedom(DOFs).The quaternion data model based on vector MISC arrays is established,which extends the scalar MISC array into the vector MISC array.Based on the model,a quaternion multiple signal classification(MUSIC)algorithm based on vector MISC arrays is proposed for DOA estimation.The algorithm combines the advantages of the quaternion model and the vector MISC array to enhance the DOA estimation performance.Analytical simulations are performed to certify the capability of the algorithm.