Firstly, the definition, structure and working principles of storage batteries in automatic meteorological observation stations were stated simply, and then the daily maintenance of the storage batteries were introduc...Firstly, the definition, structure and working principles of storage batteries in automatic meteorological observation stations were stated simply, and then the daily maintenance of the storage batteries were introduced according to previous practical experience, finally typical faults of storage batteries were analyzed. Practical evidence shows that timely external maintenance and enough supply of electrolyte can greatly extend the lifespan of storage batteries.展开更多
Due to the complex erection environment of various types of automatic stations,the provincial meteorological inspection department is difficult to carry out this work in terms of equipment or staffing. For this reason...Due to the complex erection environment of various types of automatic stations,the provincial meteorological inspection department is difficult to carry out this work in terms of equipment or staffing. For this reason,a portable temperature sensor calibrator was developed,and it uses semiconductor refrigeration technology to increase and decrease temperature quickly. It uses an intelligent PID temperature controller as a control device to provide a stable temperature environment; it is small,light and easy to operate,and it provides technical support for the calibration of temperature sensors. The structure and working principle of this equipment were analyzed,and its performance was tested. All the indicators could meet the requirements of field calibration. The calibrator will provide a strong guarantee for the reliability of temperature data obtained at automatic meteorological stations.展开更多
文摘Firstly, the definition, structure and working principles of storage batteries in automatic meteorological observation stations were stated simply, and then the daily maintenance of the storage batteries were introduced according to previous practical experience, finally typical faults of storage batteries were analyzed. Practical evidence shows that timely external maintenance and enough supply of electrolyte can greatly extend the lifespan of storage batteries.
文摘Due to the complex erection environment of various types of automatic stations,the provincial meteorological inspection department is difficult to carry out this work in terms of equipment or staffing. For this reason,a portable temperature sensor calibrator was developed,and it uses semiconductor refrigeration technology to increase and decrease temperature quickly. It uses an intelligent PID temperature controller as a control device to provide a stable temperature environment; it is small,light and easy to operate,and it provides technical support for the calibration of temperature sensors. The structure and working principle of this equipment were analyzed,and its performance was tested. All the indicators could meet the requirements of field calibration. The calibrator will provide a strong guarantee for the reliability of temperature data obtained at automatic meteorological stations.