期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Studying Effect of Magnetizing Curve Nonlinearity Index on the Occurring Chaotic Ferroresonance Oscillation in Autotransformers
1
作者 Hamid Radmanesh Mehrdad Rostami Jafar Khalilpour 《Energy and Power Engineering》 2011年第2期79-86,共8页
This paper investigates the effect of iron core saturation characteristic degree on the onset of chaotic ferrore-sonance and duration of transient chaos in an autotransformer. The transformer chosen for study has a ra... This paper investigates the effect of iron core saturation characteristic degree on the onset of chaotic ferrore-sonance and duration of transient chaos in an autotransformer. The transformer chosen for study has a rating of 50 MVA, 635.1 kV, the magnetization characteristic of the autotransformer is modeled by a single-value two-term polynomial with q = 5, 7, 11. The core loss is modeled by a linear resistance and is considered a fix value for it. Simulation results are derived by using MATLAB software and nonlinear dynamics tool such as bifurcation and phase plan diagrams. It is shown settling down to the chaotic region is increased when degree of core nonlinearity is gone from 5 to 11. 展开更多
关键词 Linear Core LOSSES CHAOTIC FERRORESONANCE Bifurcation DIAGRAMS autotransformerS
下载PDF
Comprehensive comparison of delta-and wye-connected autotransformer applied to 12-pulse rectifier 被引量:1
2
作者 Fangang MENG Lei GAO +1 位作者 Wei YANG Shiyan YANG 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2016年第1期135-145,共11页
12-pulse rectifier is extensively used in high power rectification, and the delta-connected autotransformer and wye-connected autotransformer are its two most popular phase-shift transformers. This paper compares the ... 12-pulse rectifier is extensively used in high power rectification, and the delta-connected autotransformer and wye-connected autotransformer are its two most popular phase-shift transformers. This paper compares the 12-pulse rectifiers using the two transformers via calculating the input line current, load voltage, kVA ratings of the two autotransformer, kVA ratings of the auxiliary magnetic devices. From the viewpoint of power quality of AC mains and DC side, the two 12-pulse rectifiers are the same. The kVA rating of the IPR in the two 12-pulse rectifiers are equal, and the kVA rating of the ZSBT in the two 12-pulse rectifier are also equal to each other, under the same load power. However, the kVA of the deltaconnected autotransformer is less than that of the wyeconnected autotransformer under the same load power.Some experimental results are shown to validate the correctness of the theoretical analysis. 展开更多
关键词 Multi-pulse rectifier(MPR) Delta-connected autotransformer Wye-connected autotransformer kVA rating Inter-phase reactor(IPR) Zero-sequence blocking transformer(ZSBT)
原文传递
The design and fault ride through control of un-interrupted DC-DC Autotransformer 被引量:3
3
作者 LI MengBo XIANG Wang +3 位作者 ZUO WenPing YAO LiangZhong LIN WeiXing WEN JinYu 《Science China(Technological Sciences)》 SCIE EI CAS CSCD 2018年第12期1935-1949,共15页
This paper proposed a novel type of DC-DC converter, termed as un-interrupted DC Autotransformer(un-interrupted DC AUTO), which has the capability to ride through DC fault on either side of the converter without block... This paper proposed a novel type of DC-DC converter, termed as un-interrupted DC Autotransformer(un-interrupted DC AUTO), which has the capability to ride through DC fault on either side of the converter without blocking any devices. Besides that, the adequately designed converter retains the advantages of DC AUTO technology, namely reduced investment cost and transmission loss. To begin with, the topology and basic attributes of the un-interrupted DC AUTO are illustrated. Then the design goals and the corresponding design procedures are analyzed. Furthermore, an effective control system is proposed to enable the converter steady operation during both normal and faulted conditions. Finally, a 1000 MW ±320 kV/±640 kV test system is built on PSCAD/EMTDC platform to verify the technical feasibility of the proposed converter and the effectiveness of the control strategy. 展开更多
关键词 DC-DC power conversion DC autotransformer HVDC CONVERTERS DC fault CONTROL strategy
原文传递
Consistency evaluation of the current distribution of short-circuit tests in AT feeding systems for high-speed railways
4
作者 Qing-an Ma Wei Liu 《Journal of Modern Transportation》 2018年第3期163-172,共10页
To improve the accuracy of fault location system, several short-circuit tests need to be conducted before being brought into service in autotransformer (AT) feeding systems for high-speed railways in China. However,... To improve the accuracy of fault location system, several short-circuit tests need to be conducted before being brought into service in autotransformer (AT) feeding systems for high-speed railways in China. However, no systematic algorithm yet exists to evaluate the consistency of the current distribution of short-circuit tests. A methodology is proposed in this paper to address this problem. Based on Kirchhoff’s current law and the generalized method of symmetrical components, the current deviations of the AT feeding systems are analysed and then normalized with the short-circuit current as they vary greatly with systems and short-circuit sites. It is also found that the short-circuit current varies with the calculation methods, and its unbiased standard deviation also reflects the consistency of the short-circuit test. The mean and maximum of the current deviations, as well as the unbiased standard deviation of the short-circuit current, show the consistency of the short-circuit test from different aspects,although the last two items are highly relevant. Therefore, a unified evaluation index is defined as the sum of the three items, and then applied in two case studies to test its performance. The results show that, the proposed index canclearly distinguish the consistency of the short-circuit tests and may be used to sort the short-circuit tests for fault location systems. Besides, some short-circuit tests may have very poor consistency indices, and thus are not applicable to the tuning of fault location systems. In the authors’ opinion, the determination of the threshold of the proposed index needs further investigation. 展开更多
关键词 autotransformer feeding system Short-circuittest Consistency evaluation Kirchhoff’s current law Generalized method of symmetrical components
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部