Magnetic field design is essential for the operation of Hall thrusters.This study focuses on utilizing a genetic algorithm to optimize the magnetic field configuration of SPT70.A 2D hybrid PIC-DSMC and channel-wall er...Magnetic field design is essential for the operation of Hall thrusters.This study focuses on utilizing a genetic algorithm to optimize the magnetic field configuration of SPT70.A 2D hybrid PIC-DSMC and channel-wall erosion model are employed to analyze the plume divergence angle and wall erosion rate,while a Farady probe measurement and laser profilometry system are set up to verify the simulation results.The results demonstrate that the genetic algorithm contributes to reducing the divergence angle of the thruster plumes and alleviating the impact of high-energy particles on the discharge channel wall,reducing the erosion by 5.5%and 2.7%,respectively.Further analysis indicates that the change from a divergent magnetic field to a convergent magnetic field,combined with the upstream shift of the ionization region,contributes to the improving the operation of the Hall thruster.展开更多
Experimental investigations into the effects of the magnetic field configuration near the channel exit on the plume of Hall thrusters were conducted. The magnetic field configuration near the channel exit is character...Experimental investigations into the effects of the magnetic field configuration near the channel exit on the plume of Hall thrusters were conducted. The magnetic field configuration near the channel exit is characterized by the inclination angle between the magnetic field lines and the thruster radial direction. Different inclination angles were obtained by varying the current ratio in the coils. The plume divergence angles were measured by a dual-directed probe. The results showed that the plume divergence angle increased obviously with the increase in the magnitude of the inclination angle near the channel exit. Therefore, in order to optimize the magnetic field for reducing plume divergence, the magnitude of the inclination angle should be reduced as much as possible. It suggests that the magnetic field configuration near the channel exit is another important factor that affects plume divergence.展开更多
We present in this paper the comparison of an electric double layer(DL)in argon helicon plasma and magnetized direct current(DC)discharge plasma.DL in high-density argon helicon plasma of 13.56 MHz RF discharge was in...We present in this paper the comparison of an electric double layer(DL)in argon helicon plasma and magnetized direct current(DC)discharge plasma.DL in high-density argon helicon plasma of 13.56 MHz RF discharge was investigated experimentally by a floating electrostatic probe and local optical emission spectroscopy(LOES).The DL characteristics at different operating parameters,including RF power(300-1500 W),tube diameter(8-60 mm),and external magnetic field(0-300 G),were measured.For comparison,DL in magnetized plasma channel of a DC discharge under different conditions was also measured experimentally.The results show that in both cases,DL appears in a divergent magnetic field where the magnetic field gradient is the largest and when the plasma density is sufficiently high.DL strength(or potential drop of DL)increases with the magnetic field in two different structures.It is suggested that the electric DL should be a common phenomenon in dense plasma under a gradient external magnetic field.DL in magnetized plasmas can be controlled properly by magnetic field structure and discharge mode(hence the plasma density).展开更多
The notion of the inner product of vectors is extended to tensors of different orders, which may replace the vector product usually. The essences of the differential and the codiffcrential forms are pointed out: they...The notion of the inner product of vectors is extended to tensors of different orders, which may replace the vector product usually. The essences of the differential and the codiffcrential forms are pointed out: they represent the tangent surface and the normal surface fluxes of a tensor, reslpetivcly. The definitions of the divergence and the curl of a 2D surface flux of a tensor arc obtained. Maxwell's equations, namely, the constraction law of field, which were usually established based on two conservation laws of electric charge and imaginary magnetic charge, are derived by the author only by using one conservation law ( mass or fluid flux quantity and so on) and the feature of central field (or its composition). By the feature of central field (or its composition), the curl of 2D flux is zero. Both universality of gauge field and the difficulty of magnetic monopole theory ( a magnetic monopole has no effect on electric current just like a couple hasing no effect on the sum of forces) axe presented: magnetic monopole has no the feature of magnet. Finally it is pointed out that the base of relation of mass and energy is already involved in Maxwell's equations.展开更多
基金funded by Shanghai Natural Science Foundation(No.12ZR1414700)。
文摘Magnetic field design is essential for the operation of Hall thrusters.This study focuses on utilizing a genetic algorithm to optimize the magnetic field configuration of SPT70.A 2D hybrid PIC-DSMC and channel-wall erosion model are employed to analyze the plume divergence angle and wall erosion rate,while a Farady probe measurement and laser profilometry system are set up to verify the simulation results.The results demonstrate that the genetic algorithm contributes to reducing the divergence angle of the thruster plumes and alleviating the impact of high-energy particles on the discharge channel wall,reducing the erosion by 5.5%and 2.7%,respectively.Further analysis indicates that the change from a divergent magnetic field to a convergent magnetic field,combined with the upstream shift of the ionization region,contributes to the improving the operation of the Hall thruster.
基金supported by National Natural Science Foundation of China(No.50676026)the Program for Chair Professors of"Cheung Kong Scholars Program"of China in 2008
文摘Experimental investigations into the effects of the magnetic field configuration near the channel exit on the plume of Hall thrusters were conducted. The magnetic field configuration near the channel exit is characterized by the inclination angle between the magnetic field lines and the thruster radial direction. Different inclination angles were obtained by varying the current ratio in the coils. The plume divergence angles were measured by a dual-directed probe. The results showed that the plume divergence angle increased obviously with the increase in the magnitude of the inclination angle near the channel exit. Therefore, in order to optimize the magnetic field for reducing plume divergence, the magnitude of the inclination angle should be reduced as much as possible. It suggests that the magnetic field configuration near the channel exit is another important factor that affects plume divergence.
基金supported by National Natural Science Foundation of China(No.11975047)。
文摘We present in this paper the comparison of an electric double layer(DL)in argon helicon plasma and magnetized direct current(DC)discharge plasma.DL in high-density argon helicon plasma of 13.56 MHz RF discharge was investigated experimentally by a floating electrostatic probe and local optical emission spectroscopy(LOES).The DL characteristics at different operating parameters,including RF power(300-1500 W),tube diameter(8-60 mm),and external magnetic field(0-300 G),were measured.For comparison,DL in magnetized plasma channel of a DC discharge under different conditions was also measured experimentally.The results show that in both cases,DL appears in a divergent magnetic field where the magnetic field gradient is the largest and when the plasma density is sufficiently high.DL strength(or potential drop of DL)increases with the magnetic field in two different structures.It is suggested that the electric DL should be a common phenomenon in dense plasma under a gradient external magnetic field.DL in magnetized plasmas can be controlled properly by magnetic field structure and discharge mode(hence the plasma density).
文摘The notion of the inner product of vectors is extended to tensors of different orders, which may replace the vector product usually. The essences of the differential and the codiffcrential forms are pointed out: they represent the tangent surface and the normal surface fluxes of a tensor, reslpetivcly. The definitions of the divergence and the curl of a 2D surface flux of a tensor arc obtained. Maxwell's equations, namely, the constraction law of field, which were usually established based on two conservation laws of electric charge and imaginary magnetic charge, are derived by the author only by using one conservation law ( mass or fluid flux quantity and so on) and the feature of central field (or its composition). By the feature of central field (or its composition), the curl of 2D flux is zero. Both universality of gauge field and the difficulty of magnetic monopole theory ( a magnetic monopole has no effect on electric current just like a couple hasing no effect on the sum of forces) axe presented: magnetic monopole has no the feature of magnet. Finally it is pointed out that the base of relation of mass and energy is already involved in Maxwell's equations.