AIM To investigate the value of the gamma-glutamyltraspeptidase(GGT)-to-platelet(PLT) ratio(GPR) in the diagnosis of hepatic fibrosis in patients with chronic hepatitis B(CHB). METHODS We included 390 untreated CHB pa...AIM To investigate the value of the gamma-glutamyltraspeptidase(GGT)-to-platelet(PLT) ratio(GPR) in the diagnosis of hepatic fibrosis in patients with chronic hepatitis B(CHB). METHODS We included 390 untreated CHB patients in this study. The GPR, aspartate aminotransferase(AST)-to-PLT ratio index(APRI), and fibrosis-4(FIB-4) of all patients were analysed to determine if these parameter were correlated with age, gender, medical history, liver function [total bilirubin(TBil), alanine aminotransferase(ALT), and AST], GGT, PLT count, or hepatic fibrosis stage. The GPR, APRI, and FIB-4, as well as the combination of the GPR and APRI or the GPR and FIB-4 were assessed in different cirrhosis stages using receiver operating characteristic(ROC) curve analysis to evaluate their value in diagnosing hepatic fibrosis in CHB patients. RESULTS The GPR, APRI, and FIB-4 were not correlated withCHB patients' age, gender, or disease duration(P > 0.05), but all of these parameters were positively correlated with serum ALT, AST, GGT, and PLT count(P < 0.01). Additionally, the GPR, APRI, and FIB-4 were positively correlated with hepatic fibrosis(P < 0.01); the areas under the ROC curve for the GPR in F1, F2, F3, and F4 stages were 0.723, 0.741, 0.826, and 0.833, respectively, which were significantly higher than the respective values for the FIB-4 and APRI(F1: 0.581, 0.612; F2: 0.706, 0.711; F3: 0.73, 0.751; and F4: 0.799, 0.778). The respective diagnostic cut-off points for each stage were 0.402, 0.448, 0.548, and 0.833, respectively. The diagnostic sensitivity and specificity were, respectively, 88.8% and 87.5% in F1, 72.7% and 89.7% in F2, 81.3% and 98.6% in F3, and 80% and 97.4% in F4 when the GPR and APRI were connected in parallel; 86.6% and 90.2%, 78.4% and 96%, 78.6% and 97.4%, and 73.2% and 97.9%, respectively, when the GPR and APRI were connected in series; 80.2% and 89%, 65% and 89%, 70.3% and 98.5%, and 78.8% and 96.8%, respectively, when the GPR and FIB-4 were connected in parallel; and 83.6% and 87.9%, 76.8% and 96.6%, 72.7% and 98%, and 74.4% and 97.7%, respectively, when the GPR and FIB-4 were connected in series.CONCLUSION The GPR, as a serum diagnostic index of liver fibrosis, is more accurate, sensitive, and easy to use than the FIB-4 and APRI, and the GPR can significantly improve the sensitivity and specificity of hepatic fibrosis diagnosis in CHB when combined with the FIB-4 or APRI.展开更多
We demonstrate high-performance In0.23 Ga0.77 As channel metal-oxide-semiconductor field-effect transistors ( MOS- FETs) with high on-current to off-current (Ion/Ioff) ratio grown on semi-insulating GaAs wafers by...We demonstrate high-performance In0.23 Ga0.77 As channel metal-oxide-semiconductor field-effect transistors ( MOS- FETs) with high on-current to off-current (Ion/Ioff) ratio grown on semi-insulating GaAs wafers by metal-organic chemical vapor deposition (MOCVD). The 2μm channel-length devices exhibit a peak extrinsic transeonductance of 150 mS/mm and a drain current up to 500 mA/mm. The maximum effective mobility is 1680 cm2/Vs extracted by the split C-V method. Furthermore, the Ion/Ioff ratio is significantly improved from approximately 4.5 × 10^3 up to approximately 4.32 × 10^4 by controlling the etch thickness of In0.49Ga0.51P, The high drain current and high Ion/Ioff ratio of the In0.23Ga0.77As channel MOSFETs are achieved due to the high effective mobility and the low gate leakage current density.展开更多
Objectives: The aim of this study was to explore the potential correlation between the GA/HbA1c ratio and diabetic retinopathy (DR) in patients with type 2 diabetes (T2D), as the GA/HbA1c ratio serves as a marker for ...Objectives: The aim of this study was to explore the potential correlation between the GA/HbA1c ratio and diabetic retinopathy (DR) in patients with type 2 diabetes (T2D), as the GA/HbA1c ratio serves as a marker for glycemic variability. Methods: A total of 2565 T2D patients were included in this study and grouped into five categories based on the diagnostic criteria for DR. We examined the impact of the GA/HbA1c ratio on the progression of diabetes. Results: The non-DR group exhibited lower GA/HbA1c levels compared to the DR group. Additionally, as the severity of DR increased among the five groups, there was a corresponding increase in the GA/HbA1c ratio. Logistic regression analysis demonstrated that the GA/HbA1c ratio independently elevated the risk of DR occurrence. Conclusions: The GA/HbA1c ratio can independently predict the occurrence and progression of diabetic retinopathy.展开更多
For dielectric barrier discharge lamps filled with various gas mixture ratios, the correlations between the excimer XeCl* emission and the sealed gas temperature have been founded, and a qualitative explication is pre...For dielectric barrier discharge lamps filled with various gas mixture ratios, the correlations between the excimer XeCl* emission and the sealed gas temperature have been founded, and a qualitative explication is presented. For gas mixture with chlorine larger than 3%, the emission intensity increases with the sealed gas temperature, while with chlorine about 2%, the emission intensity decreases with the increase in the gas temperature, and could be improved by cooling water. However, if chlorine is less than 1.5%, the discharge appears to be a mixture mode with filaments distributed in a diffused glow-like discharge, and the UV emission is independent on the gas temperature.展开更多
As we all know, cyclic gas injection is one of the most effective development methods to improve condensate oil recovery. When dealing with the calculation of the reserves, the injection-production differences and wat...As we all know, cyclic gas injection is one of the most effective development methods to improve condensate oil recovery. When dealing with the calculation of the reserves, the injection-production differences and water influx create great influence on the accuracy. Based on the existing research, we proposed a new material balance equation which considered the differences of composition between produced and injected fluids and the effect of water influx, and a solution was provided in this paper. The results of the method are closer to the actual situation because they are built on the law of conservation of mass, and the using of curve fitting method can not only avoid the use of water influx coefficient but also obtain the water influx rate and reserves at the same time. The YH-23 gas condensate reservoir is taking as a typical subject to do the research, which has been exploited by cycle gas injection for 14 years. Three different methods are used to calculate the reserves, and the results show that the method proposed in this paper has minimum error of 2.96%.展开更多
基金Supported by National Natural Science Foundation of China,No.81460301 and No.81760363Key Project of Natural Science Foundation of Ningxia,No.NZ15134
文摘AIM To investigate the value of the gamma-glutamyltraspeptidase(GGT)-to-platelet(PLT) ratio(GPR) in the diagnosis of hepatic fibrosis in patients with chronic hepatitis B(CHB). METHODS We included 390 untreated CHB patients in this study. The GPR, aspartate aminotransferase(AST)-to-PLT ratio index(APRI), and fibrosis-4(FIB-4) of all patients were analysed to determine if these parameter were correlated with age, gender, medical history, liver function [total bilirubin(TBil), alanine aminotransferase(ALT), and AST], GGT, PLT count, or hepatic fibrosis stage. The GPR, APRI, and FIB-4, as well as the combination of the GPR and APRI or the GPR and FIB-4 were assessed in different cirrhosis stages using receiver operating characteristic(ROC) curve analysis to evaluate their value in diagnosing hepatic fibrosis in CHB patients. RESULTS The GPR, APRI, and FIB-4 were not correlated withCHB patients' age, gender, or disease duration(P > 0.05), but all of these parameters were positively correlated with serum ALT, AST, GGT, and PLT count(P < 0.01). Additionally, the GPR, APRI, and FIB-4 were positively correlated with hepatic fibrosis(P < 0.01); the areas under the ROC curve for the GPR in F1, F2, F3, and F4 stages were 0.723, 0.741, 0.826, and 0.833, respectively, which were significantly higher than the respective values for the FIB-4 and APRI(F1: 0.581, 0.612; F2: 0.706, 0.711; F3: 0.73, 0.751; and F4: 0.799, 0.778). The respective diagnostic cut-off points for each stage were 0.402, 0.448, 0.548, and 0.833, respectively. The diagnostic sensitivity and specificity were, respectively, 88.8% and 87.5% in F1, 72.7% and 89.7% in F2, 81.3% and 98.6% in F3, and 80% and 97.4% in F4 when the GPR and APRI were connected in parallel; 86.6% and 90.2%, 78.4% and 96%, 78.6% and 97.4%, and 73.2% and 97.9%, respectively, when the GPR and APRI were connected in series; 80.2% and 89%, 65% and 89%, 70.3% and 98.5%, and 78.8% and 96.8%, respectively, when the GPR and FIB-4 were connected in parallel; and 83.6% and 87.9%, 76.8% and 96.6%, 72.7% and 98%, and 74.4% and 97.7%, respectively, when the GPR and FIB-4 were connected in series.CONCLUSION The GPR, as a serum diagnostic index of liver fibrosis, is more accurate, sensitive, and easy to use than the FIB-4 and APRI, and the GPR can significantly improve the sensitivity and specificity of hepatic fibrosis diagnosis in CHB when combined with the FIB-4 or APRI.
基金Project Supported by National Natural Science Foundation of China ( 11105067 ), Science Technology Pillar Program of Jiangxi Province, China (2009AE00100).
文摘We demonstrate high-performance In0.23 Ga0.77 As channel metal-oxide-semiconductor field-effect transistors ( MOS- FETs) with high on-current to off-current (Ion/Ioff) ratio grown on semi-insulating GaAs wafers by metal-organic chemical vapor deposition (MOCVD). The 2μm channel-length devices exhibit a peak extrinsic transeonductance of 150 mS/mm and a drain current up to 500 mA/mm. The maximum effective mobility is 1680 cm2/Vs extracted by the split C-V method. Furthermore, the Ion/Ioff ratio is significantly improved from approximately 4.5 × 10^3 up to approximately 4.32 × 10^4 by controlling the etch thickness of In0.49Ga0.51P, The high drain current and high Ion/Ioff ratio of the In0.23Ga0.77As channel MOSFETs are achieved due to the high effective mobility and the low gate leakage current density.
文摘Objectives: The aim of this study was to explore the potential correlation between the GA/HbA1c ratio and diabetic retinopathy (DR) in patients with type 2 diabetes (T2D), as the GA/HbA1c ratio serves as a marker for glycemic variability. Methods: A total of 2565 T2D patients were included in this study and grouped into five categories based on the diagnostic criteria for DR. We examined the impact of the GA/HbA1c ratio on the progression of diabetes. Results: The non-DR group exhibited lower GA/HbA1c levels compared to the DR group. Additionally, as the severity of DR increased among the five groups, there was a corresponding increase in the GA/HbA1c ratio. Logistic regression analysis demonstrated that the GA/HbA1c ratio independently elevated the risk of DR occurrence. Conclusions: The GA/HbA1c ratio can independently predict the occurrence and progression of diabetic retinopathy.
基金This work is supported by Jiangsu Suzhou Purification Group Co.Ltd.
文摘For dielectric barrier discharge lamps filled with various gas mixture ratios, the correlations between the excimer XeCl* emission and the sealed gas temperature have been founded, and a qualitative explication is presented. For gas mixture with chlorine larger than 3%, the emission intensity increases with the sealed gas temperature, while with chlorine about 2%, the emission intensity decreases with the increase in the gas temperature, and could be improved by cooling water. However, if chlorine is less than 1.5%, the discharge appears to be a mixture mode with filaments distributed in a diffused glow-like discharge, and the UV emission is independent on the gas temperature.
文摘As we all know, cyclic gas injection is one of the most effective development methods to improve condensate oil recovery. When dealing with the calculation of the reserves, the injection-production differences and water influx create great influence on the accuracy. Based on the existing research, we proposed a new material balance equation which considered the differences of composition between produced and injected fluids and the effect of water influx, and a solution was provided in this paper. The results of the method are closer to the actual situation because they are built on the law of conservation of mass, and the using of curve fitting method can not only avoid the use of water influx coefficient but also obtain the water influx rate and reserves at the same time. The YH-23 gas condensate reservoir is taking as a typical subject to do the research, which has been exploited by cycle gas injection for 14 years. Three different methods are used to calculate the reserves, and the results show that the method proposed in this paper has minimum error of 2.96%.