AIM: To evaluate the diagnostic value of B-scan ultrasound and explore the cytological characteristics of patients with vitreoretinal lymphoma(VRL) and primary central nervous system lymphoma(PCNSL).METHODS: The clini...AIM: To evaluate the diagnostic value of B-scan ultrasound and explore the cytological characteristics of patients with vitreoretinal lymphoma(VRL) and primary central nervous system lymphoma(PCNSL).METHODS: The clinical data and pathologic specimens from patients with VRL diagnosed at the North Huashan Hospital from 2016 to 2017 were retrospectively reviewed. The patients were diagnosed by slit lamp ophthalmoscopy, B-scan ultrasound, cytology of the vitreous, which was obtained by vitrectomy, and cytokine measurements of interleukin(IL)-10 and IL-6.RESULTS: Twenty-six eyes(19.4%) out of 134 eyes of 67 patients(47 men and 20 women) with PCNSL were diagnosed with VRL by B-scan ultrasound, and 14 eyes(10.4%) were diagnosed by slit lamp ophthalmoscopy. Twenty-four eyes(17.9%) of 17 patients were confirmed as having VRL with cytology. No difference in the association between intracranial lesion location and ocular involvement was found. VRL patients had higher levels of vitreous IL-10 and IL-10/IL-6 when compared with macular hole cases, but the difference was not statistically significant.CONCLUSION: A total of 25.4% of the PCNSL patients had VRL, B-scan ultrasound examination had characteristic features and is recommended over slit lamp ophthalmoscopy for the screening diagnosis of PCNSL with intraocular involvement. Moreover, the cytological and immunohistochemical analyses performed after 25-gauge diagnostic vitrectomy were accurate diagnostic techniques.展开更多
·AIM: To evaluate the accuracy of 20 MHz immersion Bscan ultrasonography in observing lens and to investigate the value of this noninvasive preoperative diagnosis method in alkali burn eyes.·METHODS: It was ...·AIM: To evaluate the accuracy of 20 MHz immersion Bscan ultrasonography in observing lens and to investigate the value of this noninvasive preoperative diagnosis method in alkali burn eyes.·METHODS: It was a comparative study. Fifty-six cases(56 eyes) of alkali burn eyes were examined by ultrasound biomicroscopy(UBM) and immersion 20 MHz B-scan ultrasonography from June 2011 to April 2013,the images were analyzed, and the ultrasonographic diagnosis compared with the operation results.·RESULTS: In 56 alkali burn eyes examined by UBM, the lens were not detected in 16 eyes; the IOL could be detected in 2 eyes; the anterior lens capsule surface or/and the front lens could be detected in 18 eyes, and lens opacification in 3 eyes of them; suspected abnormal lens were detected in the other 20 eyes. In all the same eyes examined by immersion 20 MHz B-scan ultrasonography,the lens were not detected in 16 eyes; the IOL could be detected in 2 eyes; 24 abnormal lens(opacity, lens expansion, shrinkage) and 14 normal lens were found.Compared with the intraoperative findings, the diagnostic accordance rate of the immersion 20 MHz B-scan appearance of lens was 100%(56/56), which was significantly higher than examined by UBM 57.14%(32/56)(χ2=30.55, P =0.0000).·CONCLUSION: Immersion 20 MHz B-scan ultrasonography can observe the lens accurately in alkali burn eyes. It has important clinical value to combine with UBM in eyes of alkali burn.展开更多
In order to optimize the wood internal quality detection and evaluation system and improve the comprehensive utilization rate of wood,this paper invented a set of log internal defect detection and visualization system...In order to optimize the wood internal quality detection and evaluation system and improve the comprehensive utilization rate of wood,this paper invented a set of log internal defect detection and visualization system by using the ultrasonic dry coupling agent method.The detection and visualization analysis of internal log defects were realized through log specimen test.The main conclusions show that the accuracy,reliability and practicability of the system for detecting the internal defects of log specimens have been effectively verified.The system can make the edge of the detected image smooth by interpolation algorithm,and the edge detection algorithm can be used to detect and reflect the location of internal defects of logs accurately.The content mentioned above has good application value for meeting the requirement of increasing demand for wood resources and improving the automation level of wood nondestructive testing instruments.展开更多
基金Supported by the National Natural Science Foundation of China(No.81700123)the Shanghai Hospital Development Centre(No.16CR2043B)
文摘AIM: To evaluate the diagnostic value of B-scan ultrasound and explore the cytological characteristics of patients with vitreoretinal lymphoma(VRL) and primary central nervous system lymphoma(PCNSL).METHODS: The clinical data and pathologic specimens from patients with VRL diagnosed at the North Huashan Hospital from 2016 to 2017 were retrospectively reviewed. The patients were diagnosed by slit lamp ophthalmoscopy, B-scan ultrasound, cytology of the vitreous, which was obtained by vitrectomy, and cytokine measurements of interleukin(IL)-10 and IL-6.RESULTS: Twenty-six eyes(19.4%) out of 134 eyes of 67 patients(47 men and 20 women) with PCNSL were diagnosed with VRL by B-scan ultrasound, and 14 eyes(10.4%) were diagnosed by slit lamp ophthalmoscopy. Twenty-four eyes(17.9%) of 17 patients were confirmed as having VRL with cytology. No difference in the association between intracranial lesion location and ocular involvement was found. VRL patients had higher levels of vitreous IL-10 and IL-10/IL-6 when compared with macular hole cases, but the difference was not statistically significant.CONCLUSION: A total of 25.4% of the PCNSL patients had VRL, B-scan ultrasound examination had characteristic features and is recommended over slit lamp ophthalmoscopy for the screening diagnosis of PCNSL with intraocular involvement. Moreover, the cytological and immunohistochemical analyses performed after 25-gauge diagnostic vitrectomy were accurate diagnostic techniques.
基金Supported by National Key Basic Research Program of China(973 Program,No.2013CB967001)National Natural Science Foundation of China(No.81271052,No.31271059)
文摘·AIM: To evaluate the accuracy of 20 MHz immersion Bscan ultrasonography in observing lens and to investigate the value of this noninvasive preoperative diagnosis method in alkali burn eyes.·METHODS: It was a comparative study. Fifty-six cases(56 eyes) of alkali burn eyes were examined by ultrasound biomicroscopy(UBM) and immersion 20 MHz B-scan ultrasonography from June 2011 to April 2013,the images were analyzed, and the ultrasonographic diagnosis compared with the operation results.·RESULTS: In 56 alkali burn eyes examined by UBM, the lens were not detected in 16 eyes; the IOL could be detected in 2 eyes; the anterior lens capsule surface or/and the front lens could be detected in 18 eyes, and lens opacification in 3 eyes of them; suspected abnormal lens were detected in the other 20 eyes. In all the same eyes examined by immersion 20 MHz B-scan ultrasonography,the lens were not detected in 16 eyes; the IOL could be detected in 2 eyes; 24 abnormal lens(opacity, lens expansion, shrinkage) and 14 normal lens were found.Compared with the intraoperative findings, the diagnostic accordance rate of the immersion 20 MHz B-scan appearance of lens was 100%(56/56), which was significantly higher than examined by UBM 57.14%(32/56)(χ2=30.55, P =0.0000).·CONCLUSION: Immersion 20 MHz B-scan ultrasonography can observe the lens accurately in alkali burn eyes. It has important clinical value to combine with UBM in eyes of alkali burn.
文摘In order to optimize the wood internal quality detection and evaluation system and improve the comprehensive utilization rate of wood,this paper invented a set of log internal defect detection and visualization system by using the ultrasonic dry coupling agent method.The detection and visualization analysis of internal log defects were realized through log specimen test.The main conclusions show that the accuracy,reliability and practicability of the system for detecting the internal defects of log specimens have been effectively verified.The system can make the edge of the detected image smooth by interpolation algorithm,and the edge detection algorithm can be used to detect and reflect the location of internal defects of logs accurately.The content mentioned above has good application value for meeting the requirement of increasing demand for wood resources and improving the automation level of wood nondestructive testing instruments.