Introduction: Ultrasound is an essential component of antenatal care. Midwives provide most of the antenatal care but they do not perform ultrasound as it has been beyond their scope of practice. This leaves many wome...Introduction: Ultrasound is an essential component of antenatal care. Midwives provide most of the antenatal care but they do not perform ultrasound as it has been beyond their scope of practice. This leaves many women in Low and Middle-Income Countries without access to ultrasound scanning. The aim of this study was to identify competencies in ultrasound scanning in midwifery education. Methods: A desk review and needs assessment were conducted between July and October 2023. Articles and curricula on the internet, Google scholar and PubMed were searched for content on ultrasound scanning competencies. A Google form consisting of 20 questions was administered via email and WhatsApp to 135 participants. Descriptive statistics were used to analyse data. Results: The desk review showed that it is feasible to train midwives in ultrasound scanning. The training programs for midwives in obstetric ultrasound were conducted for 1 week to 3 months with most of them running for 4 weeks. Content included introduction to general principles of ultrasound, physics, basic knowledge in embryology, obstetrics, anatomy, measuring foetal biometry, estimating amniotic fluid and gestational age. Experts like sonographers trained midwives. Theory and hands on were the teaching methods used. Written and practical assessments were conducted. Needs assessment revealed that majority of participants 71 (53%) knew about basic ultrasound training for midwives. All participants (100%) said it is necessary to train midwives in basic ultrasound scan in Zambia. Some content should include, anatomy, measuring foetal biometry, assessing amniotic fluid level, and gestational age determination. Most participants 91 (67%) suggested that the appropriate duration of training is 4 - 6 weeks. Conclusion: Empowering every midwife with ultrasound scanning skills will enable early detection of any abnormality among pregnant women and prompt intervention to save lives.展开更多
High-frequency image technique has been widely applied in medical diagnosis recently. For high voltage protection, high speed stage and trigger control circuitry are difficult to implement a high-frequency ultrasound ...High-frequency image technique has been widely applied in medical diagnosis recently. For high voltage protection, high speed stage and trigger control circuitry are difficult to implement a high-frequency ultrasound imaging system. In this study, we utilized a linear servo with high noise tolerance and a novel multi-depth expression method to overcome those issues in developed high-speed image system. B-mode image of the chicken phantom by 25 MHz transducer shows the resolution of lateral and axial resolutions are up to 123 μm and 59 μm respectively. In addition, the experiment demonstrates that the axial resolution and depth of field (DOF) can be improved by time gain compensation(TGC) and multi-depth method. The results indicate that the proposed system could achieve over 24 fps for 1 mm scan distance and 100 lines per frame. In the future, the developed system is potential for other clinical applications such as ophthalmology and dermatology.展开更多
AIM: To evaluate the diagnostic value of B-scan ultrasound and explore the cytological characteristics of patients with vitreoretinal lymphoma(VRL) and primary central nervous system lymphoma(PCNSL).METHODS: The clini...AIM: To evaluate the diagnostic value of B-scan ultrasound and explore the cytological characteristics of patients with vitreoretinal lymphoma(VRL) and primary central nervous system lymphoma(PCNSL).METHODS: The clinical data and pathologic specimens from patients with VRL diagnosed at the North Huashan Hospital from 2016 to 2017 were retrospectively reviewed. The patients were diagnosed by slit lamp ophthalmoscopy, B-scan ultrasound, cytology of the vitreous, which was obtained by vitrectomy, and cytokine measurements of interleukin(IL)-10 and IL-6.RESULTS: Twenty-six eyes(19.4%) out of 134 eyes of 67 patients(47 men and 20 women) with PCNSL were diagnosed with VRL by B-scan ultrasound, and 14 eyes(10.4%) were diagnosed by slit lamp ophthalmoscopy. Twenty-four eyes(17.9%) of 17 patients were confirmed as having VRL with cytology. No difference in the association between intracranial lesion location and ocular involvement was found. VRL patients had higher levels of vitreous IL-10 and IL-10/IL-6 when compared with macular hole cases, but the difference was not statistically significant.CONCLUSION: A total of 25.4% of the PCNSL patients had VRL, B-scan ultrasound examination had characteristic features and is recommended over slit lamp ophthalmoscopy for the screening diagnosis of PCNSL with intraocular involvement. Moreover, the cytological and immunohistochemical analyses performed after 25-gauge diagnostic vitrectomy were accurate diagnostic techniques.展开更多
Background: Some researchers have suggested that when Naegle’s rule (NR) and Dubowitz score (DS) are combined, it could out-perform obstetric ultrasound scan (USS). Others still believe that obstetric USS alone is st...Background: Some researchers have suggested that when Naegle’s rule (NR) and Dubowitz score (DS) are combined, it could out-perform obstetric ultrasound scan (USS). Others still believe that obstetric USS alone is still effective relative to the combination of NR rule and DS in assessing the gestational age (GA) of babies. Objectives: To determine and compare the GA of babies using obstetric USS, NR and DS;and to provide relevant public health information on obstetric USS in the 21st century. Methods: Subjects were selected using systematic random sampling and the GA of babies was determined using obstetric USS, NR, and DS. Statistical package for social science (SPSS) statistical software version 16, Illinois, Chicago USA was used for all data analysis. Results: Eightyfive mother-baby pairs were studied. Forty-four babies (52%) were males and 41 (48%) females. Sixty four (75%) were term with a mean (SD) BW of 3.02 (0.59) at 95%CI (2.89 -?3.14) kg. The overall mean GA of the babies was 38.49 (2.89) at 95%CI (38.14 -?38.85) weeks. The mean GA using obstetric USS, NR and DS were 38.52 (1.98) at 95%CI (38.14 -?38.99), 38.09 (4.13) at 95%CI (37.20-?38.99) and 38.82 (2.02) at 95%CI (38.39 -?39.26), but comparison of these means was not significant (p = 0.256). Combined mean GA by NR and DS was 38.46 (3.26) at 95%CI (37.96 -?38.95). Comparing this mean with mean GA obtained by obstetric USS was also not significant (p = 0.885). Conclusion: The GA assessments by Obstetric USS, NR and DS were all reliable, and Obstetric USS performed effectively relative to combined NR and DS.展开更多
Morbid Adherent Placenta (MAP)/Placenta Accreta Spectrum (PAS) is a serious diagnosis which has a risk of complications. Ultrasound scan helps in early diagnosis and has great value in further confirmation and follow ...Morbid Adherent Placenta (MAP)/Placenta Accreta Spectrum (PAS) is a serious diagnosis which has a risk of complications. Ultrasound scan helps in early diagnosis and has great value in further confirmation and follow up. Observed new clinical sign and associated clinical triad are discussed here.展开更多
Artificial intelligence (AI)-based radiomics has attracted considerable research attention in the field of medical imaging, including ultrasound diagnosis. Ultrasound imaging has unique advantages such as high tempora...Artificial intelligence (AI)-based radiomics has attracted considerable research attention in the field of medical imaging, including ultrasound diagnosis. Ultrasound imaging has unique advantages such as high temporal resolution, low cost, and no radiation exposure. This renders it a preferred imaging modality for several clinical scenarios. This review includes a detailed introduction to imaging modalities, including Brightness-mode ultrasound, color Doppler flow imaging, ultrasound elastography, contrast-enhanced ultrasound, and multi-modal fusion analysis. It provides an overview of the current status and prospects of AI-based radiomics in ultrasound diagnosis, highlighting the application of AI-based radiomics to static ultrasound images, dynamic ultrasound videos, and multi-modal ultrasound fusion analysis.展开更多
Objective To study the role of bladder trabeculation found by B-mode ultrasound in evaluating the degree of bladder outlet obstruction ( BOO ) and the bladder function in benign prostatic hyperplasia ( BPH) patients. ...Objective To study the role of bladder trabeculation found by B-mode ultrasound in evaluating the degree of bladder outlet obstruction ( BOO ) and the bladder function in benign prostatic hyperplasia ( BPH) patients. Methods Conducted prospective research to determine differences in clinical data and urodynamic展开更多
This paper presents a flexible and high speed digital scan converter (DSC) with the ability to handle high frequency ultrasound imaging in real-time. The characteristics in imaging system such as focus length of trans...This paper presents a flexible and high speed digital scan converter (DSC) with the ability to handle high frequency ultrasound imaging in real-time. The characteristics in imaging system such as focus length of transducer, the swing radius and sampling length etc. could be changed easily in compliance with the researcher's application based on this flexible digital scan converter. Linear interpolation is employed to achieve the coordinate transformations algorithm. Custom-built software is programmed to preliminarily handle the algorithm according to different ultrasound imaging applications. High performance FPGA will implement high speed interpolation calculation based on the preliminary data which are stored in the DDR2 SDRAM from the software. 64 bit 66 MHz PCI is employed to accomplish high speed data transmission. Experiment has shown that more than 500 frame rate could be achieved based on this high speed digital scan converter. The designed flexible and high speed digital scan converter could be used in current FPGA based high frequency ultrasound imaging system.展开更多
A rare differential diagnosis for severe abdominal pain is acute epiploic appendagitis. Its symptoms resemble those of acute diverticulitis, acute appendicitis, or omental infarction quite a bit. The primary imaging m...A rare differential diagnosis for severe abdominal pain is acute epiploic appendagitis. Its symptoms resemble those of acute diverticulitis, acute appendicitis, or omental infarction quite a bit. The primary imaging method used for diagnosis is computed tomography (CT). We are describing the case of a 27-year-old guy who underwent an abdominal ultrasonography after complaining of severe left lower quadrant abdominal pain. It identified an oval and non-compressible hyperechoic mass in the left iliac fossa. The mass was surrounded by a hypoechoic rim and there was no color Doppler signal. In the absence of CT, radiologists must be able to diagnose acute epiploic appendagitis on ultrasound in order to avoid unnecessary hospital admission, pricey laboratory tests, antibiotic treatment, and unnecessary surgery. In this instance, the patient was spared from ionization exposure from a potential CT scan and other invasive treatments including surgery with associated costs because of the reliable ultrasound diagnosis of epiploic appendagitis. After receiving conservative medical treatment, the patient was placed under surveillance and then discharged.展开更多
Cutaneous neurofibroma(cNF)is a prevalent clinical manifestation of neurofibromatosis type 1,significantly affecting the well-being and quality of life of the affected individuals.The adoption of reliable and reproduc...Cutaneous neurofibroma(cNF)is a prevalent clinical manifestation of neurofibromatosis type 1,significantly affecting the well-being and quality of life of the affected individuals.The adoption of reliable and reproducible volumetric measurement techniques is essential for precisely evaluating tumor burden and plays a critical role in the development of effective treatments for cNF.This study focuses on widely used volumetric measurement techniques,including vernier calipers,ultrasound,computed tomography,magnetic resonance imaging,and three-dimensional scanning imaging.It outlines the merits and drawbacks of each technique in assessing the cNF load,providing an overview of their current applications and ongoing research advancements in this domain.展开更多
文摘Introduction: Ultrasound is an essential component of antenatal care. Midwives provide most of the antenatal care but they do not perform ultrasound as it has been beyond their scope of practice. This leaves many women in Low and Middle-Income Countries without access to ultrasound scanning. The aim of this study was to identify competencies in ultrasound scanning in midwifery education. Methods: A desk review and needs assessment were conducted between July and October 2023. Articles and curricula on the internet, Google scholar and PubMed were searched for content on ultrasound scanning competencies. A Google form consisting of 20 questions was administered via email and WhatsApp to 135 participants. Descriptive statistics were used to analyse data. Results: The desk review showed that it is feasible to train midwives in ultrasound scanning. The training programs for midwives in obstetric ultrasound were conducted for 1 week to 3 months with most of them running for 4 weeks. Content included introduction to general principles of ultrasound, physics, basic knowledge in embryology, obstetrics, anatomy, measuring foetal biometry, estimating amniotic fluid and gestational age. Experts like sonographers trained midwives. Theory and hands on were the teaching methods used. Written and practical assessments were conducted. Needs assessment revealed that majority of participants 71 (53%) knew about basic ultrasound training for midwives. All participants (100%) said it is necessary to train midwives in basic ultrasound scan in Zambia. Some content should include, anatomy, measuring foetal biometry, assessing amniotic fluid level, and gestational age determination. Most participants 91 (67%) suggested that the appropriate duration of training is 4 - 6 weeks. Conclusion: Empowering every midwife with ultrasound scanning skills will enable early detection of any abnormality among pregnant women and prompt intervention to save lives.
文摘High-frequency image technique has been widely applied in medical diagnosis recently. For high voltage protection, high speed stage and trigger control circuitry are difficult to implement a high-frequency ultrasound imaging system. In this study, we utilized a linear servo with high noise tolerance and a novel multi-depth expression method to overcome those issues in developed high-speed image system. B-mode image of the chicken phantom by 25 MHz transducer shows the resolution of lateral and axial resolutions are up to 123 μm and 59 μm respectively. In addition, the experiment demonstrates that the axial resolution and depth of field (DOF) can be improved by time gain compensation(TGC) and multi-depth method. The results indicate that the proposed system could achieve over 24 fps for 1 mm scan distance and 100 lines per frame. In the future, the developed system is potential for other clinical applications such as ophthalmology and dermatology.
基金Supported by the National Natural Science Foundation of China(No.81700123)the Shanghai Hospital Development Centre(No.16CR2043B)
文摘AIM: To evaluate the diagnostic value of B-scan ultrasound and explore the cytological characteristics of patients with vitreoretinal lymphoma(VRL) and primary central nervous system lymphoma(PCNSL).METHODS: The clinical data and pathologic specimens from patients with VRL diagnosed at the North Huashan Hospital from 2016 to 2017 were retrospectively reviewed. The patients were diagnosed by slit lamp ophthalmoscopy, B-scan ultrasound, cytology of the vitreous, which was obtained by vitrectomy, and cytokine measurements of interleukin(IL)-10 and IL-6.RESULTS: Twenty-six eyes(19.4%) out of 134 eyes of 67 patients(47 men and 20 women) with PCNSL were diagnosed with VRL by B-scan ultrasound, and 14 eyes(10.4%) were diagnosed by slit lamp ophthalmoscopy. Twenty-four eyes(17.9%) of 17 patients were confirmed as having VRL with cytology. No difference in the association between intracranial lesion location and ocular involvement was found. VRL patients had higher levels of vitreous IL-10 and IL-10/IL-6 when compared with macular hole cases, but the difference was not statistically significant.CONCLUSION: A total of 25.4% of the PCNSL patients had VRL, B-scan ultrasound examination had characteristic features and is recommended over slit lamp ophthalmoscopy for the screening diagnosis of PCNSL with intraocular involvement. Moreover, the cytological and immunohistochemical analyses performed after 25-gauge diagnostic vitrectomy were accurate diagnostic techniques.
文摘Background: Some researchers have suggested that when Naegle’s rule (NR) and Dubowitz score (DS) are combined, it could out-perform obstetric ultrasound scan (USS). Others still believe that obstetric USS alone is still effective relative to the combination of NR rule and DS in assessing the gestational age (GA) of babies. Objectives: To determine and compare the GA of babies using obstetric USS, NR and DS;and to provide relevant public health information on obstetric USS in the 21st century. Methods: Subjects were selected using systematic random sampling and the GA of babies was determined using obstetric USS, NR, and DS. Statistical package for social science (SPSS) statistical software version 16, Illinois, Chicago USA was used for all data analysis. Results: Eightyfive mother-baby pairs were studied. Forty-four babies (52%) were males and 41 (48%) females. Sixty four (75%) were term with a mean (SD) BW of 3.02 (0.59) at 95%CI (2.89 -?3.14) kg. The overall mean GA of the babies was 38.49 (2.89) at 95%CI (38.14 -?38.85) weeks. The mean GA using obstetric USS, NR and DS were 38.52 (1.98) at 95%CI (38.14 -?38.99), 38.09 (4.13) at 95%CI (37.20-?38.99) and 38.82 (2.02) at 95%CI (38.39 -?39.26), but comparison of these means was not significant (p = 0.256). Combined mean GA by NR and DS was 38.46 (3.26) at 95%CI (37.96 -?38.95). Comparing this mean with mean GA obtained by obstetric USS was also not significant (p = 0.885). Conclusion: The GA assessments by Obstetric USS, NR and DS were all reliable, and Obstetric USS performed effectively relative to combined NR and DS.
文摘Morbid Adherent Placenta (MAP)/Placenta Accreta Spectrum (PAS) is a serious diagnosis which has a risk of complications. Ultrasound scan helps in early diagnosis and has great value in further confirmation and follow up. Observed new clinical sign and associated clinical triad are discussed here.
基金the National Natural Science Foundation of China,Nos.92159305,92259303,62027901,81930053,and 82272029Beijing Science Fund for Distinguished Young Scholars,No.JQ22013and Excellent Member Project of the Youth Innovation Promotion Association CAS,No.2016124.
文摘Artificial intelligence (AI)-based radiomics has attracted considerable research attention in the field of medical imaging, including ultrasound diagnosis. Ultrasound imaging has unique advantages such as high temporal resolution, low cost, and no radiation exposure. This renders it a preferred imaging modality for several clinical scenarios. This review includes a detailed introduction to imaging modalities, including Brightness-mode ultrasound, color Doppler flow imaging, ultrasound elastography, contrast-enhanced ultrasound, and multi-modal fusion analysis. It provides an overview of the current status and prospects of AI-based radiomics in ultrasound diagnosis, highlighting the application of AI-based radiomics to static ultrasound images, dynamic ultrasound videos, and multi-modal ultrasound fusion analysis.
文摘Objective To study the role of bladder trabeculation found by B-mode ultrasound in evaluating the degree of bladder outlet obstruction ( BOO ) and the bladder function in benign prostatic hyperplasia ( BPH) patients. Methods Conducted prospective research to determine differences in clinical data and urodynamic
文摘This paper presents a flexible and high speed digital scan converter (DSC) with the ability to handle high frequency ultrasound imaging in real-time. The characteristics in imaging system such as focus length of transducer, the swing radius and sampling length etc. could be changed easily in compliance with the researcher's application based on this flexible digital scan converter. Linear interpolation is employed to achieve the coordinate transformations algorithm. Custom-built software is programmed to preliminarily handle the algorithm according to different ultrasound imaging applications. High performance FPGA will implement high speed interpolation calculation based on the preliminary data which are stored in the DDR2 SDRAM from the software. 64 bit 66 MHz PCI is employed to accomplish high speed data transmission. Experiment has shown that more than 500 frame rate could be achieved based on this high speed digital scan converter. The designed flexible and high speed digital scan converter could be used in current FPGA based high frequency ultrasound imaging system.
文摘A rare differential diagnosis for severe abdominal pain is acute epiploic appendagitis. Its symptoms resemble those of acute diverticulitis, acute appendicitis, or omental infarction quite a bit. The primary imaging method used for diagnosis is computed tomography (CT). We are describing the case of a 27-year-old guy who underwent an abdominal ultrasonography after complaining of severe left lower quadrant abdominal pain. It identified an oval and non-compressible hyperechoic mass in the left iliac fossa. The mass was surrounded by a hypoechoic rim and there was no color Doppler signal. In the absence of CT, radiologists must be able to diagnose acute epiploic appendagitis on ultrasound in order to avoid unnecessary hospital admission, pricey laboratory tests, antibiotic treatment, and unnecessary surgery. In this instance, the patient was spared from ionization exposure from a potential CT scan and other invasive treatments including surgery with associated costs because of the reliable ultrasound diagnosis of epiploic appendagitis. After receiving conservative medical treatment, the patient was placed under surveillance and then discharged.
文摘Cutaneous neurofibroma(cNF)is a prevalent clinical manifestation of neurofibromatosis type 1,significantly affecting the well-being and quality of life of the affected individuals.The adoption of reliable and reproducible volumetric measurement techniques is essential for precisely evaluating tumor burden and plays a critical role in the development of effective treatments for cNF.This study focuses on widely used volumetric measurement techniques,including vernier calipers,ultrasound,computed tomography,magnetic resonance imaging,and three-dimensional scanning imaging.It outlines the merits and drawbacks of each technique in assessing the cNF load,providing an overview of their current applications and ongoing research advancements in this domain.