期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Radiation Beam Characterization and Dosimetry of Theratron Equinox-80 Telecobalt Machine Using BEAMnrc Monte Carlo Simulation Code
1
作者 Narayan Prasad Patel Rahul Shukla +4 位作者 Nagappan Balasubramanian Rajeev Atri Anil Kumar Dhull Hanuman Prasad Yadav Vivek Kaushal 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2016年第4期298-316,共19页
The BEAMnrc code was used for the simulation of the Theratron Equinox-80 telecobalt machine. The phase space of radiation beam was generated at treatment distance of 80 cm for various field sizes. The phase spaces in ... The BEAMnrc code was used for the simulation of the Theratron Equinox-80 telecobalt machine. The phase space of radiation beam was generated at treatment distance of 80 cm for various field sizes. The phase spaces in air were analyzed by BEAMdp data processing program. The electron energy fluence with respect to photon energy was 0.09% and 0.34% for field size of 05 × 05 and 35 × 35 cm<sup>2</sup> respectively and it was maximum at the central axis which gradually decreases beyond this. The profiles for photon fluence were in symmetry for all the fields. The full width at half maximum of profiles in photon energy fluence shows good agreement with the field size. The photon energy fluence was flat till the field size of 27 cm<sup>2</sup>, after which it decreases gradually till the edge in larger field sizes. The air-kerma output factor from the simulation was in good agreement with measured value. We analyzed the dose data scored in the voxels in a large water phantom by simulation using dosxyznrc code. The percentage depth dose for all field sizes was in good agreement with the BJR supplement 25 and the data supplied by the manufacturer of machine. Significant deviation of about 20% in isodose line near the edge of the profile was observed for 35 × 35 cm<sup>2</sup> field size. The penumbra widths of all field sizes were comparable except for 35 × 35 cm<sup>2</sup>, which has a penumbra width of 4.1 cm at 10 cm depth. The significant under dose near the edge as compared to central axis for larger field sizes may be the indication for its careful use in treatment. 展开更多
关键词 beamnrc code Simulation Telecobalt Unit Beam Profile Depth Dose
下载PDF
医用直线加速器治疗头的蒙特卡罗模拟 被引量:6
2
作者 程品晶 王宇 凌球 《核电子学与探测技术》 CAS CSCD 北大核心 2009年第1期105-107,142,共4页
本文使用蒙特卡罗模拟软件BEAMnrc,构建出加速器治疗头各部件,并进行6MV电子束经过钨靶产生光子束在加速器治疗头各部件中的传输模拟,获得源皮距为100cm,射野大小为10cm×10cm的开放野治疗平面上的粒子相空间信息。并用BEAMDP程序... 本文使用蒙特卡罗模拟软件BEAMnrc,构建出加速器治疗头各部件,并进行6MV电子束经过钨靶产生光子束在加速器治疗头各部件中的传输模拟,获得源皮距为100cm,射野大小为10cm×10cm的开放野治疗平面上的粒子相空间信息。并用BEAMDP程序对该粒子相空间数据进行了分析,得到源模型所在平面的光子和电子的注量、能谱、角分布、平均能量等信息。 展开更多
关键词 加速器治疗头 蒙特卡罗方法 相空间数据 beamnrc程序
下载PDF
上一页 1 下一页 到第