期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
The Balcony
1
《数字娱乐技术》 2011年第7期60-63,共4页
黄昏时分,潜入城堡的盗贼不小心碰倒了一个罐子.闻声而来的主人大发霄霆.引发了三个人连续死亡。
关键词 北京电影学院动画学院 毕业生动画作品 The balcony 3D定格动面
下载PDF
A Brief Discussion on the Landscape Balconies of New Buildings
2
作者 Ni Lan Feng Huang +2 位作者 Xutong Liu Xin Xiang Junjie Chen 《Journal of Architectural Research and Development》 2024年第1期38-42,共5页
With the acceleration of urbanization and the improvement of people’s living standards,people have increasingly higher requirements for the living environment,especially in the design of outdoor balconies.However,exi... With the acceleration of urbanization and the improvement of people’s living standards,people have increasingly higher requirements for the living environment,especially in the design of outdoor balconies.However,existing landscape balconies generally suffer from insufficient shading and rainwater drainage problems,which affects people’s living experience.In response to this problem,this article proposes a new design scheme for building landscape balconies to solve the existing problems of landscape balconies.This design plan fully considers the user’s usage needs and scenarios,improves the use value and comfort of the balcony through technical means,and achieves intelligence and functionality. 展开更多
关键词 Landscape balcony INTELLIGENCE FUNCTIONALIZATION Market analysis
下载PDF
A Critical study on Fire-induced Aerodynamics of Balcony Spill Plumes
3
作者 Junmei LI Yanfeng LI Yun Liu Suduo Xue 《Journal of Thermal Science》 SCIE EI CAS CSCD 2008年第3期281-287,共7页
Balcony spill plume is one of the main plume forms in an atrium fire, its thermal behavior which is important to the designers for the smoke control system design is still not well understood now. The fire-induced aer... Balcony spill plume is one of the main plume forms in an atrium fire, its thermal behavior which is important to the designers for the smoke control system design is still not well understood now. The fire-induced aerodynamics of balcony spill plume would be studied by the numerical method in this paper. Some uncertainties relating to the available calculation methods for the smoke production rate would be reexamined. Numerical results indicated that using an entrainment coefficient 0.11 would be better than 0.16 in describing the entrainment behavior, end effect should not be ignored for the plume being not two-dimensional (2-D). Suitable empirical spill plume equations would be recommended for the smoke management system design. 展开更多
关键词 balcony spill plume atrium fire numerical method smoke management
原文传递
Investigation of the Effects of Glazed Balconies uponThermal Comfort in Hot Tropical Region
4
作者 Érica Coelho Pagel Edna Aparecida Nico Rodrigues +4 位作者 Cristina Engel de Alvarez Neyval Costa Reis Júnior Bruna Perovano Sirtuli Filipe Galina Costalonga Jordana BernabéCoelho 《Journal of Civil Engineering and Architecture》 2019年第12期762-779,共18页
The balcony is responsible to a series of effects on the environmental behavior of a building,mainly in relation of thermal comfort and air distribution to their indoor spaces.Currently a very common practice in sever... The balcony is responsible to a series of effects on the environmental behavior of a building,mainly in relation of thermal comfort and air distribution to their indoor spaces.Currently a very common practice in several metropolitan areas is the closing with retractable glass panels in balcony openings.This work analyzed the effects of glazed balconies upon thermal comfort in a hot tropical region.Environmental parameters were carried out in a flat alternating the conditions of retractable glass panels to balconies.Thermal simulations were performed considering closing or not the glass door that divides the balcony room;the building material used on the balcony sill;and the use of curtains or shading devices.The results show the maximum mean hourly temperatures recorded on the balcony during the period when the retractable glass panels were closed,reaching peaks between 31.7 and 39.2°C,above the comfort range recommended by ASHRAE 55.All situations simulated show the thermal discomfort prevails in the use of the closed glass panels reaching DhTD of 94.55°C/day.Thus,this practice of using most of the closed retractable glass panels in the balconies presents disadvantages and inefficiencies especially in hot and humid tropical climate regions. 展开更多
关键词 Glazed balconies thermal comfort hot tropical region.
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部