BACKGROUND Closed reduction and internal fixation with intramedullary nails has been widely accepted for treating intertrochanteric fractures.AIM To focus on how to avoid displacement of the lesser trochanter in unsta...BACKGROUND Closed reduction and internal fixation with intramedullary nails has been widely accepted for treating intertrochanteric fractures.AIM To focus on how to avoid displacement of the lesser trochanter in unstable intertrochanteric fractures.METHODS We developed a lesser trochanteric reduction fixator for treating intertrochanteric fractures through fixing the lesser trochanter by combining the loop plate through the fixator after reduction by the reducer.Five patients with intertrochanteric fractures treated with the newly developed lesser trochanteric reduction fixator and loop plate combined with intramedullary nails,and 20 patients with intertrochanteric fractures treated with simple intramedullary nails were selected from December 2020 to March 2021.RESULTS The postoperative Harris hip score was significantly higher in patients treated with the lesser trochanteric reduction fixator than in patients treated without the lesser trochanteric reduction fixator,which indicated that this lesser trochanteric reduction fixator had a positive impact on rehabilitation of the hip joint after surgery and could significantly improve the quality of life of patients.CONCLUSION We fully realize the significance of trochanteric reduction and fixation,namely,reconstruction of structures under pressure,in the treatment of intertrochanteric fractures.As long as the general condition of patients is favorable and they are willing to undergo surgery,fixation of the main fracture end should be performed and the lesser trochanter should be reduced and fixed at the same time.展开更多
Background: Pelvic fractures constitute about 2% - 8% of all fractures. This incidence may rise up to 25% in poly-traumatised patients. These fractures have a high mortality rate due to the fact that they occur usuall...Background: Pelvic fractures constitute about 2% - 8% of all fractures. This incidence may rise up to 25% in poly-traumatised patients. These fractures have a high mortality rate due to the fact that they occur usually as a result of high energy trauma, and most of the injured are poly-traumatised with concomitant haemodynamic instability. The aim of this study is to describe the patterns of injury and complications of unstable pelvic fractures treated in a level III hospital in Cameroon. Methodology: This was a hospital based retrospective analysis of files of patients admitted and treated for unstable pelvic fractures at the Regional Hospital Limbe within a period of 10 years (from 1<sup>st</sup> of January 2009 to 31<sup>st</sup> of December 2018). Results: A total of 139 cases of pelvic fractures were identified, amongst which 77 were unstable;68 were finally analyzed. The ages ranged from 18 to 80 years with a mean of 39 ± 5 years. The age group from 20 - 40 years was most represented (58.88%, n = 40). There were 45 males and 23 females giving a sex-ratio of 2:1. Road traffic injuries accounted for most of the cases (73.53%, n = 50). Forty-five (66.2%) were classified Tile B and 23 (33.82%) were Tile C, and 15 cases were open fractures (22.06%). Associated lesions were recorded in 30 cases, fractures of the lower extremity being the most common (33.33%, n = 10). Most of the cases were definitively treated surgically (80.89%, n = 55). The most common complications were surgical site infections (23.64%, n = 13). Conclusion: Unstable pelvic fractures are relatively common. Young males in the age group 20 - 40 years are the most affected, and the most common cause of injury was road traffic accident. Surgical site infections, pressure ulcers, severe anaemia and thrombo-embolism are common complications.展开更多
BACKGROUND Older people are more likely to experience pelvic fractures than younger people.Multi-slice spiral computed tomography(CT)uses three-dimensional(3D)reconstruction technology to generate 3D images that can c...BACKGROUND Older people are more likely to experience pelvic fractures than younger people.Multi-slice spiral computed tomography(CT)uses three-dimensional(3D)reconstruction technology to generate 3D images that can clearly demonstrate the 3D space of fractures and detect fractures at a higher rate.AIM To investigate the clinical value of multi-slice spiral CT 3D reconstruction in the diagnosis of unstable pelvic fractures in the elderly as well as the effect of less invasive stabilization.METHODS A total of 86 patients with unstable pelvic fractures treated between March 2016 and March 2019 underwent femoral supracondylar bone traction before surgery.Pelvic radiography and multi-row spiral CT were performed successively once the patient’s vital signs and hemodynamic indices were stable.Secondary processing of the original data was performed to obtain 3D reconstruction images and determine the vertical displacement of the pelvis.After basic or complete reduction,minimally invasive internal fixation using hollow lag screws was performed.The detection rates of fracture location and classification by X-ray and CT reconstruction were compared.Patients were divided into two groups according to the presence or absence of preoperative 3D reconstruction to compare postoperative reduction,wound healing time,fracture healing time,hospitalization time,visual analog scale(VAS)score,poor internal fixation,and functional recovery.RESULTS The diagnostic coincidence rates of X-rays for pubic symphysis,ilium wing,sacroiliac periarticular,and sacral fractures were lower than those of CT reconstruction.The coincidence rate of CT reconstruction in the clinical classification of pelvic fractures was 100%,whereas 11 cases were misdiagnosed by X-ray;the total coincidence rate was 87.21%.The total excellent and good rates of postoperative reduction were significantly higher in the study group than in the control group(P<0.05).The wound healing,fracture healing,and hospitalization times were significantly shorter in the study group than in the control group(P<0.05).The VAS scores decreased in both groups postoperatively and were lower in the study group than in the control group(P<0.05).The total incidence of poor postoperative internal fixation was significantly lower in the study group than in the control group(P<0.05).The overall rate of postoperative functional recovery was significantly higher in the study group than in the control group(P<0.05).CONCLUSION Multi-slice spiral CT has high guiding significance for the diagnosis,classification,and treatment of unstable pelvic fractures in the elderly.Preoperative 3D reconstruction can effectively shorten the operation time and promote fracture healing,while minimally invasive internal fixation can effectively reduce pain and promote functional recovery of fracture sites,making it worthy of clinical application.展开更多
Objective To evaluate the clinical outcomes of external fixator with lumbopelvic distraction spondylodesis in treatment of vertically unstable pelvic fractures.Methods From January 2008 to March 2009,9 patients(4 male...Objective To evaluate the clinical outcomes of external fixator with lumbopelvic distraction spondylodesis in treatment of vertically unstable pelvic fractures.Methods From January 2008 to March 2009,9 patients(4 males and 5 females)展开更多
Background Patients with pelvic fractures are often treated in hospitals without the capacity to implement an open reduction internal fixation (ORIF). This often leads to pelvic malunion in patients with unstable pe...Background Patients with pelvic fractures are often treated in hospitals without the capacity to implement an open reduction internal fixation (ORIF). This often leads to pelvic malunion in patients with unstable pelvic fracture, shock or even death due to uncontrollable pelvic hemorrhage and unstable hemodynamics. This study explored the role of early external fixation (within 7 days) for patients with unstable pelvic fractures. Methods A retrospective analysis was conducted on 32 patients with unstable pelvic fractures treated with early external fixation from January 2005 to January 2010 (Tile type B: 18 cases; C: 14 cases). The study comprised 28 males and 4 females, with a mean age of (32_+8) years (range, 21-56 years). Of these patients, 22 were treated with emergency pelvic external fixation and 10 were treated with external fixation within 1-7 days. Fifteen cases suffered traumatic hemorrhagic shock. A statistical analysis was conducted to compare fluid infusion and blood transfusion volumes within the first 24 hours of these shock patients with another cohort of patients treated without early external fixation from January 1993 to January 1998. Results The average follow-up was (34.7_+14.6) months (range, 6-66 months). Six to eight weeks after external fixation, patients could walk with crutches; by 12 weeks, external fixation was removed and all fractures had healed. Seven patients presented with sequelae, including 3 patients with long-term lumbosacral pain, 3 patients with erectile dysfunction and 1 patient with MoreI-Lavallee lesion and other complications. The 15 shock patients in this study (2005-2010 group) required significantly lower volumes of fluid infusion and blood transfusion (Pfluid=0.000; mtransfusion=0.000) as compared to the 1993-1998 cohort. Conclusions The early application of external fixation in unstable pelvic fracture patients positively affects hemodynamic stability, with outstanding efficacy as a final fixation option for unstable pelvic fractures.展开更多
An internal-external fixator for stabilization in three cases with unstable pelvic fractures were reported. Compared with external fixation, the internal-external fixator, which is placed in the subcutaneous layer, de...An internal-external fixator for stabilization in three cases with unstable pelvic fractures were reported. Compared with external fixation, the internal-external fixator, which is placed in the subcutaneous layer, decreased the risk of pin-track infection, pin site pain, and bowel obstruction; meanwhile, it had the advantage of external fixation: it was easy to apply, controlled damage, and resulted in minimal injury.展开更多
文摘BACKGROUND Closed reduction and internal fixation with intramedullary nails has been widely accepted for treating intertrochanteric fractures.AIM To focus on how to avoid displacement of the lesser trochanter in unstable intertrochanteric fractures.METHODS We developed a lesser trochanteric reduction fixator for treating intertrochanteric fractures through fixing the lesser trochanter by combining the loop plate through the fixator after reduction by the reducer.Five patients with intertrochanteric fractures treated with the newly developed lesser trochanteric reduction fixator and loop plate combined with intramedullary nails,and 20 patients with intertrochanteric fractures treated with simple intramedullary nails were selected from December 2020 to March 2021.RESULTS The postoperative Harris hip score was significantly higher in patients treated with the lesser trochanteric reduction fixator than in patients treated without the lesser trochanteric reduction fixator,which indicated that this lesser trochanteric reduction fixator had a positive impact on rehabilitation of the hip joint after surgery and could significantly improve the quality of life of patients.CONCLUSION We fully realize the significance of trochanteric reduction and fixation,namely,reconstruction of structures under pressure,in the treatment of intertrochanteric fractures.As long as the general condition of patients is favorable and they are willing to undergo surgery,fixation of the main fracture end should be performed and the lesser trochanter should be reduced and fixed at the same time.
文摘Background: Pelvic fractures constitute about 2% - 8% of all fractures. This incidence may rise up to 25% in poly-traumatised patients. These fractures have a high mortality rate due to the fact that they occur usually as a result of high energy trauma, and most of the injured are poly-traumatised with concomitant haemodynamic instability. The aim of this study is to describe the patterns of injury and complications of unstable pelvic fractures treated in a level III hospital in Cameroon. Methodology: This was a hospital based retrospective analysis of files of patients admitted and treated for unstable pelvic fractures at the Regional Hospital Limbe within a period of 10 years (from 1<sup>st</sup> of January 2009 to 31<sup>st</sup> of December 2018). Results: A total of 139 cases of pelvic fractures were identified, amongst which 77 were unstable;68 were finally analyzed. The ages ranged from 18 to 80 years with a mean of 39 ± 5 years. The age group from 20 - 40 years was most represented (58.88%, n = 40). There were 45 males and 23 females giving a sex-ratio of 2:1. Road traffic injuries accounted for most of the cases (73.53%, n = 50). Forty-five (66.2%) were classified Tile B and 23 (33.82%) were Tile C, and 15 cases were open fractures (22.06%). Associated lesions were recorded in 30 cases, fractures of the lower extremity being the most common (33.33%, n = 10). Most of the cases were definitively treated surgically (80.89%, n = 55). The most common complications were surgical site infections (23.64%, n = 13). Conclusion: Unstable pelvic fractures are relatively common. Young males in the age group 20 - 40 years are the most affected, and the most common cause of injury was road traffic accident. Surgical site infections, pressure ulcers, severe anaemia and thrombo-embolism are common complications.
文摘BACKGROUND Older people are more likely to experience pelvic fractures than younger people.Multi-slice spiral computed tomography(CT)uses three-dimensional(3D)reconstruction technology to generate 3D images that can clearly demonstrate the 3D space of fractures and detect fractures at a higher rate.AIM To investigate the clinical value of multi-slice spiral CT 3D reconstruction in the diagnosis of unstable pelvic fractures in the elderly as well as the effect of less invasive stabilization.METHODS A total of 86 patients with unstable pelvic fractures treated between March 2016 and March 2019 underwent femoral supracondylar bone traction before surgery.Pelvic radiography and multi-row spiral CT were performed successively once the patient’s vital signs and hemodynamic indices were stable.Secondary processing of the original data was performed to obtain 3D reconstruction images and determine the vertical displacement of the pelvis.After basic or complete reduction,minimally invasive internal fixation using hollow lag screws was performed.The detection rates of fracture location and classification by X-ray and CT reconstruction were compared.Patients were divided into two groups according to the presence or absence of preoperative 3D reconstruction to compare postoperative reduction,wound healing time,fracture healing time,hospitalization time,visual analog scale(VAS)score,poor internal fixation,and functional recovery.RESULTS The diagnostic coincidence rates of X-rays for pubic symphysis,ilium wing,sacroiliac periarticular,and sacral fractures were lower than those of CT reconstruction.The coincidence rate of CT reconstruction in the clinical classification of pelvic fractures was 100%,whereas 11 cases were misdiagnosed by X-ray;the total coincidence rate was 87.21%.The total excellent and good rates of postoperative reduction were significantly higher in the study group than in the control group(P<0.05).The wound healing,fracture healing,and hospitalization times were significantly shorter in the study group than in the control group(P<0.05).The VAS scores decreased in both groups postoperatively and were lower in the study group than in the control group(P<0.05).The total incidence of poor postoperative internal fixation was significantly lower in the study group than in the control group(P<0.05).The overall rate of postoperative functional recovery was significantly higher in the study group than in the control group(P<0.05).CONCLUSION Multi-slice spiral CT has high guiding significance for the diagnosis,classification,and treatment of unstable pelvic fractures in the elderly.Preoperative 3D reconstruction can effectively shorten the operation time and promote fracture healing,while minimally invasive internal fixation can effectively reduce pain and promote functional recovery of fracture sites,making it worthy of clinical application.
文摘Objective To evaluate the clinical outcomes of external fixator with lumbopelvic distraction spondylodesis in treatment of vertically unstable pelvic fractures.Methods From January 2008 to March 2009,9 patients(4 males and 5 females)
文摘Background Patients with pelvic fractures are often treated in hospitals without the capacity to implement an open reduction internal fixation (ORIF). This often leads to pelvic malunion in patients with unstable pelvic fracture, shock or even death due to uncontrollable pelvic hemorrhage and unstable hemodynamics. This study explored the role of early external fixation (within 7 days) for patients with unstable pelvic fractures. Methods A retrospective analysis was conducted on 32 patients with unstable pelvic fractures treated with early external fixation from January 2005 to January 2010 (Tile type B: 18 cases; C: 14 cases). The study comprised 28 males and 4 females, with a mean age of (32_+8) years (range, 21-56 years). Of these patients, 22 were treated with emergency pelvic external fixation and 10 were treated with external fixation within 1-7 days. Fifteen cases suffered traumatic hemorrhagic shock. A statistical analysis was conducted to compare fluid infusion and blood transfusion volumes within the first 24 hours of these shock patients with another cohort of patients treated without early external fixation from January 1993 to January 1998. Results The average follow-up was (34.7_+14.6) months (range, 6-66 months). Six to eight weeks after external fixation, patients could walk with crutches; by 12 weeks, external fixation was removed and all fractures had healed. Seven patients presented with sequelae, including 3 patients with long-term lumbosacral pain, 3 patients with erectile dysfunction and 1 patient with MoreI-Lavallee lesion and other complications. The 15 shock patients in this study (2005-2010 group) required significantly lower volumes of fluid infusion and blood transfusion (Pfluid=0.000; mtransfusion=0.000) as compared to the 1993-1998 cohort. Conclusions The early application of external fixation in unstable pelvic fracture patients positively affects hemodynamic stability, with outstanding efficacy as a final fixation option for unstable pelvic fractures.
文摘An internal-external fixator for stabilization in three cases with unstable pelvic fractures were reported. Compared with external fixation, the internal-external fixator, which is placed in the subcutaneous layer, decreased the risk of pin-track infection, pin site pain, and bowel obstruction; meanwhile, it had the advantage of external fixation: it was easy to apply, controlled damage, and resulted in minimal injury.