期刊文献+
共找到3,218篇文章
< 1 2 161 >
每页显示 20 50 100
Frequency and associated factors of accommodation and non-strabismic binocular vision dysfunction among medical university students
1
作者 Jie Cai Wen-Wen Fan +5 位作者 Yun-Hui Zhong Cai-Lan Wen Xiao-Dan Wei Wan-Chen Wei Wan-Yan Xiang Jin-Mao Chen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期374-379,共6页
AIM:To investigate the frequency and associated factors of accommodation and non-strabismic binocular vision dysfunction among medical university students.METHODS:Totally 158 student volunteers underwent routine visio... AIM:To investigate the frequency and associated factors of accommodation and non-strabismic binocular vision dysfunction among medical university students.METHODS:Totally 158 student volunteers underwent routine vision examination in the optometry clinic of Guangxi Medical University.Their data were used to identify the different types of accommodation and nonstrabismic binocular vision dysfunction and to determine their frequency.Correlation analysis and logistic regression were used to examine the factors associated with these abnormalities.RESULTS:The results showed that 36.71%of the subjects had accommodation and non-strabismic binocular vision issues,with 8.86%being attributed to accommodation dysfunction and 27.85%to binocular abnormalities.Convergence insufficiency(CI)was the most common abnormality,accounting for 13.29%.Those with these abnormalities experienced higher levels of eyestrain(χ2=69.518,P<0.001).The linear correlations were observed between the difference of binocular spherical equivalent(SE)and the index of horizontal esotropia at a distance(r=0.231,P=0.004)and the asthenopia survey scale(ASS)score(r=0.346,P<0.001).Furthermore,the right eye's SE was inversely correlated with the convergence of positive and negative fusion images at close range(r=-0.321,P<0.001),the convergence of negative fusion images at close range(r=-0.294,P<0.001),the vergence facility(VF;r=-0.234,P=0.003),and the set of negative fusion images at far range(r=-0.237,P=0.003).Logistic regression analysis indicated that gender,age,and the difference in right and binocular SE did not influence the emergence of these abnormalities.CONCLUSION:Binocular vision abnormalities are more prevalent than accommodation dysfunction,with CI being the most frequent type.Greater binocular refractive disparity leads to more severe eyestrain symptoms. 展开更多
关键词 optometry clinic non-strabismic binocular vision dysfunction college students convergence insufficiency
下载PDF
Assessment of the effects of induced anisometropia on binocularity with glasses-free 3D technique 被引量:1
2
作者 Xu-Bo Yang Wei-Dong Huang Yong-Chuan Liao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第4期601-607,共7页
AIM:To assess the effect of experimentally induced anisometropia on binocularity in normal adults with glassesfree three-dimensional(3D)technique.METHODS:Totally 54 healthy medical students with normal binocularity in... AIM:To assess the effect of experimentally induced anisometropia on binocularity in normal adults with glassesfree three-dimensional(3D)technique.METHODS:Totally 54 healthy medical students with normal binocularity in the cross-sectional study were enrolled.Anisometropia was induced by placing trail lenses over the right eye,in 0.5 D steps including lenses of-0.5,-1,-1.5,-2,-2.5 D(hyperopic anisometropia)and lenses of+0.5,+1,+1.5,+2,+2.5 D(myopic anisometropia).The glasses-free 3D technique was used to evaluated not only fine stereopsis,but also coarse stereopsis,dynamic stereopsis,foveal suppression,and peripheral suppression in these subjects.One-way analysis of variance was used to compare quantitative data such as fine stereopsis,coarse stereopsis.Pearson’s Chi-square test was performed to compare categorical data such as dynamic stereopsis,foveal suppression and peripheral suppression.RESULTS:The subjects showed a statistically significant decline in fine stereopsis,coarse stereopsis,and dynamic stereopsis with increasing levels of anisometropia(P<0.001).Binocularity was af fected when induced anisometropia was more than 1 D(P<0.05).Foveal suppression and peripheral suppression were evident and increased in proportion to anisometropia(P<0.001).CONCLUSION:The relatively low degrees of anisometropia may have a potentially significant effect on high-grade binocular interaction.The mechanisms underlying the defect of binocularity seem to involve not only foveal suppression,but also peripheral suppression. 展开更多
关键词 ANISOMETROPIA binocularity STEREOPSIS glasses-free 3D technique
下载PDF
Effect of visual perception training on binocular visual function reconstruction in patients after strabismus surgery
3
作者 Yu Su Fei Wang +1 位作者 Tao Wang Qin-Mei Wang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第10期1657-1661,共5页
AIM:To explore the effect of visual perception learning software training(VPT)on binocular visual function reconstruction in children with intermittent exotropia after strabismus surgery.METHODS:Ninety children with i... AIM:To explore the effect of visual perception learning software training(VPT)on binocular visual function reconstruction in children with intermittent exotropia after strabismus surgery.METHODS:Ninety children with intermittent exotropia admitted to our hospital from June 2018 to December 2018 were included,and randomly divided into VPT and control groups.Children in the control group received basic binocular vision training,while those in the VPT group received VPT after strabismus surgery.Tertiary visual function,visual perception function,Newcastle Control Score(NCS),and ocular position retraction rate were compared at 3 and 12mo after the surgery.RESULTS:At 3 and 12mo after the surgery,the proportion of simultaneous perception,binocular fusion version and binocular stereo vision in the VPT group was conspicuously higher than that in the control group(P<0.05).After the vision training,the binocular visual perception functions of children in both groups were significantly improved compared with that before training(P<0.05).Interestingly,the grating sharpness,texture perception and texture motion perception in the VPT group were dramatically better than control group(P<0.01).The NCS in the VPT group was significantly lower than that in the control group(P<0.05).The ocular position retraction rate in the VPT group was significantly lower than that in the control group at 12mo(8.89%vs 26.67%,P=0.03).CONCLUSION:VPT effectively promotes binocular visual function reconstruction in intermittent exotropia children after strabismus surgery and reduces the strabismus severity and ocular position retraction rate. 展开更多
关键词 CHILDREN intermittent exotropia visual perception training ocular position binocular visual function
下载PDF
Improvement of Binocular Reconstruction Algorithm for Measuring 3D Pavement Texture Using a Single Laser Line Scanning Constraint
4
作者 Yuanyuan Wang RuiWang +1 位作者 Xiaofeng Ren Junan Lei 《Computer Modeling in Engineering & Sciences》 SCIE EI 2023年第8期1951-1972,共22页
The dense and accurate measurement of 3D texture is helpful in evaluating the pavement function.To form dense mandatory constraints and improve matching accuracy,the traditional binocular reconstruction technology was... The dense and accurate measurement of 3D texture is helpful in evaluating the pavement function.To form dense mandatory constraints and improve matching accuracy,the traditional binocular reconstruction technology was improved threefold.First,a single moving laser line was introduced to carry out global scanning constraints on the target,which would well overcome the difficulty of installing and recognizing excessive laser lines.Second,four kinds of improved algorithms,namely,disparity replacement,superposition synthesis,subregion segmentation,and subregion segmentation centroid enhancement,were established based on different constraint mechanism.Last,the improved binocular reconstruction test device was developed to realize the dual functions of 3D texture measurement and precision self-evaluation.Results show that compared with traditional algorithms,the introduction of a single laser line scanning constraint is helpful in improving the measurement’s accuracy.Among various improved algorithms,the improvement effect of the subregion segmentation centroid enhancement method is the best.It has a good effect on both overall measurement and single pointmeasurement,which can be considered to be used in pavement function evaluation. 展开更多
关键词 3D pavement texture binocular reconstruction algorithm single laser line scanning constraint improved stereo matching
下载PDF
Symptomatic accommodative and binocular dysfunctions from the use of flat-panel displays 被引量:3
5
作者 Esteban Porcar Juan Carlos Montalt +1 位作者 Alvaro M. Pons Enrique Espana-Gregor 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第3期501-505,共5页
AIM: To determine the presence of symptomatic accommodative and non-strabismic binocular dysfunctions (A.sBD) in a non-presbyopic population of video display unit (VDU) users with flat-panel displays. METHODS: ... AIM: To determine the presence of symptomatic accommodative and non-strabismic binocular dysfunctions (A.sBD) in a non-presbyopic population of video display unit (VDU) users with flat-panel displays. METHODS: One hundred and one VDU users, aged between 20 to 34y, initially participated in the study. This study excluded contact-lens wearers and subjects who had undergone refractive surgery or had any systemic or ocular disease. First, subjects were asked about the type and nature of eye symptoms they experienced during VDU use. Then, a thorough eye examination excluded those subjects with a significant uncorrected refractive error or other problem, such as ocular motility disorders, vertical deviation, strabismus and eye diseases. Finally, the remaining participants underwent an exhaustive assessment of their accommodative and binocular vision status. RESULTS: Eighty-nine VDU users (46 females and 43 males) were included in this study. They used flat-panel displays for an average of 5±1.9h a day. Twenty subjects presented A.sBD (22.5%). Convergence excess was the most frequent non-strabismic binocular dysfunction (9 subjects), followed by fusional vergence dysfunction (3 subjects) and convergence insufficiency (2 subjects). Within the accommodative dysfunctions, accommodative excess was the most common (4 subjects), followed by accommodative insufficiency (2 subjects). Moderate to severe eye symptoms were found in 13 subjects with ANSBD. CONCLUSION: Significant eye symptoms in VDU users with accommodative and/or non-strabismic binocular dysfunctions often occur and should not be underestimated; therefore, an appropriate evaluation of accommodative and binocular vision status is more important for this population, 展开更多
关键词 general binocular dysfunctions accommodativedysfunctions non-strabismic binocular dysfunctions eyesymptoms video display unit
下载PDF
Three-Dimensional Reconstruction of Welding Pool Surface by Binocular Vision 被引量:6
6
作者 Zunan Gu Ji Chen Chuansong Wu 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2021年第3期272-284,共13页
Current research of binocular vision systems mainly need to resolve the camera’s intrinsic parameters before the reconstruction of three-dimensional(3D)objects.The classical Zhang’calibration is hardly to calculate ... Current research of binocular vision systems mainly need to resolve the camera’s intrinsic parameters before the reconstruction of three-dimensional(3D)objects.The classical Zhang’calibration is hardly to calculate all errors caused by perspective distortion and lens distortion.Also,the image-matching algorithm of the binocular vision system still needs to be improved to accelerate the reconstruction speed of welding pool surfaces.In this paper,a preset coordinate system was utilized for camera calibration instead of Zhang’calibration.The binocular vision system was modified to capture images of welding pool surfaces by suppressing the strong arc interference during gas metal arc welding.Combining and improving the algorithms of speeded up robust features,binary robust invariant scalable keypoints,and KAZE,the feature information of points(i.e.,RGB values,pixel coordinates)was extracted as the feature vector of the welding pool surface.Based on the characteristics of the welding images,a mismatch-elimination algorithm was developed to increase the accuracy of image-matching algorithms.The world coordinates of matching feature points were calculated to reconstruct the 3D shape of the welding pool surface.The effectiveness and accuracy of the reconstruction of welding pool surfaces were verified by experimental results.This research proposes the development of binocular vision algorithms that can reconstruct the surface of welding pools accurately to realize intelligent welding control systems in the future. 展开更多
关键词 Surface reconstruction Welding pool binocular imaging Gas metal arc welding Feature points matching
下载PDF
An Active Stereo Vision System Based on Neural Pathways of Human Binocular Motor System 被引量:3
7
作者 Yu-zhang Gu Makoto Sato Xiao-lin Zhang 《Journal of Bionic Engineering》 SCIE EI CSCD 2007年第4期185-192,共8页
An active stereo vision system based on a model of neural pathways of human binocular motor system is proposed. With this model, it is guaranteed that the two cameras of the active stereo vision system can keep their ... An active stereo vision system based on a model of neural pathways of human binocular motor system is proposed. With this model, it is guaranteed that the two cameras of the active stereo vision system can keep their lines of sight fixed on the same target object during smooth pursuit. This feature is very important for active stereo vision systems, since not only 3D reconstruction needs the two cameras have an overlapping field of vision, but also it can facilitate the 3D reconstruction algorithm. To evaluate the effectiveness of the proposed method, some software simulations are done to demonstrate the same target tracking characteristic in a virtual environment apt to mistracking easily. Here, mistracking means two eyes track two different objects separately. Then the proposed method is implemented in our active stereo vision system to perform real tracking task in a laboratory scene where several persons walk self-determining. Before the proposed model is implemented in the system, mistracking occurred frequently. After it is enabled, mistracking never occurred. The result shows that the vision system based on neural pathways of human binocular motor system can reliably avoid mistracking. 展开更多
关键词 binocular motor system neural pathway GAZE mistracking
下载PDF
Accuracy study of a binocular-stereo-vision-based navigation robot for minimally invasive interventional procedures 被引量:4
8
作者 Ran Wang Ying Han +5 位作者 Min-Zhou Luo Nai-Kun Wang Wei-Wei Sun Shi-Chong Wang Hua-Dong Zhang Li-Juan Lu 《World Journal of Clinical Cases》 SCIE 2020年第16期3440-3449,共10页
BACKGROUND Medical robot is a promising surgical tool,but no specific one has been designed for interventional treatment of chronic pain.We developed a computed tomography-image based navigation robot using a new regi... BACKGROUND Medical robot is a promising surgical tool,but no specific one has been designed for interventional treatment of chronic pain.We developed a computed tomography-image based navigation robot using a new registration method with binocular vision.This kind of robot is appropriate for minimal invasive interventional procedures and easy to operate.The feasibility,accuracy and stability of this new robot need to be tested.AIM To assess quantitatively the feasibility,accuracy and stability of the binocularstereo-vision-based navigation robot for minimally invasive interventional procedures.METHODS A box model was designed for assessing the accuracy for targets at different distances.Nine(three sets)lead spheres were embedded in the model as puncture goals.The entry-to-target distances were set 50 mm(short-distance),100 mm(medium-distance)and 150 mm(long-distance).Puncture procedure was repeated three times for each goal.The Euclidian error of each puncture was calculated and statistically analyzed.Three head phantoms were used to explore the clinical feasibility and stability.Three independent operators conducted foramen ovale placement on head phantoms(both sides)by freehand or under the guidance of robot(18 punctures with each method).The operation time,adjustment time and one-time success rate were recorded,and the two guidancemethods were compared.RESULTS On the box model,the mean puncture errors of navigation robot were 1.7±0.9 mm for the short-distance target,2.4±1.0 mm for the moderate target and 4.4±1.4 mm for the long-distance target.On the head phantom,no obvious differences in operation time and adjustment time were found among the three performers(P>0.05).The median adjustment time was significantly less under the guidance of the robot than under free hand.The one-time success rate was significantly higher with the robot(P<0.05).There was no obvious difference in operation time between the two methods(P>0.05).CONCLUSION In the laboratory environment,accuracy of binocular-stereo-vision-based navigation robot is acceptable for target at 100 mm depth or less.Compared with freehand,foramen ovale placement accuracy can be improved with robot guidance. 展开更多
关键词 Navigation robot binocular stereo vision Interventional procedure Pain management Trigeminal neuralgia Needle placement
下载PDF
Binocular Vision Positioning Method for Safety Monitoring of Solitary Elderly 被引量:1
9
作者 Lihua Zhu Yan Zhang +1 位作者 Yu Wang Cheire Cheng 《Computers, Materials & Continua》 SCIE EI 2022年第4期593-609,共17页
In nowadays society,the safety of the elderly population is becoming a pressing concern,especially for those who live alone.There might be daily risks such as accidental falling or treatment attack on them.Aiming at t... In nowadays society,the safety of the elderly population is becoming a pressing concern,especially for those who live alone.There might be daily risks such as accidental falling or treatment attack on them.Aiming at these problems,indoor positioning could be a critical way to monitor their states.With the rapidly development of the imaging techniques,wearable and portable cameras are very popular,which could be set on human individual.And in view of the advantages of the visual positioning,the authors propose a binocular visual positioning algorithm to real-timely locate the elderly indoor.In this paper,the imaging model has been established with the corrected image data from the binocular camera;then feature extraction has been completed to provide reference to adjacent image matching based on the binary robust independent elementary feature(BRIEF)descriptor,finally the camera movement and the states of the elderly have been estimated to distinguish their falling risk.In the experiments,the real-sense D435i sensors were adopted as the binocular cameras to obtain indoor images,and three experimental scenarios have been carried out to test the proposed method.The results show that the proposed algorithm can effectively locate the elderly indoor and improve the real-time monitoring capability. 展开更多
关键词 Indoor positioning binocular vision feature matching solitary elderly safety monitoring
下载PDF
Research on Extraction of Bottom of Shoe Pattern Based on Binocular Stereo Vision 被引量:1
10
作者 MA Xin-wu GAN Yi SUN Fu-jia 《International Journal of Plant Engineering and Management》 2016年第1期20-34,共15页
In order to quickly and efficiently get the information of the bottom of the shoe pattern and spraying trajectory, the paper proposes a method based on binocular stereo vision. After acquiring target image, edge detec... In order to quickly and efficiently get the information of the bottom of the shoe pattern and spraying trajectory, the paper proposes a method based on binocular stereo vision. After acquiring target image, edge detection based on the canny algorithm, the paper begins stereo matching based on area and characteristics of algorithm. To eliminate false matching points, the paper uses the principle of polar geometry in computer vision. For the purpose of gaining the 3D point cloud of spraying curve, the paper adopts the principle of binocular stereo vision 3D measurement, and then carries on cubic spline curve fitting. By HALCON image processing software programming, it proves the feasibility and effectiveness of the method 展开更多
关键词 binocular stereo vision camera calibration EDGE stereo matching FITTING
下载PDF
Binocular Visual Navigation and Obstacle Avoidance of Mobile Robots Based on Speeded-Up Robust Features 被引量:1
11
作者 WANG Meng-di HAN Bao-ling LUO Qing-sheng 《Computer Aided Drafting,Design and Manufacturing》 2013年第4期18-24,共7页
This article presents a good robust and real-time system scheme of the mobile robot obstacle detection and navigation, which principle of work is based on the feature descriptor SURF. In this scheme, firstly, the imag... This article presents a good robust and real-time system scheme of the mobile robot obstacle detection and navigation, which principle of work is based on the feature descriptor SURF. In this scheme, firstly, the image information of the mobile robot path was captured by the binocular camera; then the feature points were extracted and corresponding matched using SURF to the binocular images as the undetected obstacles; finally fixed the position of the objective by the parallax between the matching points combining with the binocular vision calibration model. Theoretical derivation and experimental results show that this scheme is more accurate for the detection and navigation of the interest points. It has fast matching speed and high accuracy and low error. So, it has certain practical effect and popularizing value for the mobile robot real-time obstacle avoidance and navigation. 展开更多
关键词 speeded up robust features binocular vision robot navigation obstacle detection
下载PDF
Design of an Intelligent Robotic Excavator Based on Binocular Visual Recognition Technique 被引量:1
12
作者 ZHANG Xin LIU Jing WEN Huai-xing 《International Journal of Plant Engineering and Management》 2009年第1期48-51,共4页
Research on intelligent and robotic excavator has become a focus both at home and abroad, and this type of excavator becomes more and more important in application. In this paper, we developed a control system which c... Research on intelligent and robotic excavator has become a focus both at home and abroad, and this type of excavator becomes more and more important in application. In this paper, we developed a control system which can make the intelligent robotic excavator perform excavating operation autonomously. It can recognize the excavating targets by itself, program the operation automatically based on the original parameter, and finish all the tasks. Experimental results indicate the validity in real-time performance and precision of the control system. The intelligent robotic excavator can remarkably ease the labor intensity and enhance the working efficiency. 展开更多
关键词 excavating robot binocular visual recognition distributed control system trajectory tracing
下载PDF
RANGE ACQUISITION IN BINOCULAR 3-D COMPUTER VISION USING EDGE-BASED HIERARCHICAL MATCHING
13
作者 李允明 金声 《Journal of China Textile University(English Edition)》 EI CAS 1990年第1期1-6,共6页
This paper deals with a binocular 3-D computer vision system based on the hierarchicalmatching of edge features, Frei and Chen operator is used to extract the edge. The averagegradients of an image obtained by two iso... This paper deals with a binocular 3-D computer vision system based on the hierarchicalmatching of edge features, Frei and Chen operator is used to extract the edge. The averagegradients of an image obtained by two isotropic operators are non-equal quantized andthresholded in an angle, Edge features are extracted after passing a preemphasis transferfunction which can equalize, the noise affection. Binary edge images are decomposed into apyramid structure which is stored and searched using llliffe’s location method. Corre-sponding points are used to determine the range data using triangulation based on an improvedTrivedi’s formula. In calibration the authors set the optical axes of the two cameras parallelto simplify the calculation, A 3 rd order Householder transform is used to solve the compati-ble coupled equations. 展开更多
关键词 binocular VISION hierarchy pyramid 3-D computer VISION HIERARCHICAL registration RANGE ACQUISITION
下载PDF
Experiment Research on Binocular Perceptual Characteristics around Peripheral Vision for Development of Head Mounted Display with Wide View
14
作者 Li Xiao-guang Wu Jing-long Kawamura Sadao 《Journal of Bionic Engineering》 SCIE EI CSCD 2005年第1期47-56,共10页
The head mounted display (HMD) is widely used in virtual reality technology. In common HMD, however, the binocular disparity is set to an equal fixed value in the entire range of view. Such HMD systems have several ... The head mounted display (HMD) is widely used in virtual reality technology. In common HMD, however, the binocular disparity is set to an equal fixed value in the entire range of view. Such HMD systems have several shortcomings when used for wide views. In this study, in order to realize a natural stereo sensation of HMD with wide view, we measure the characteristics of binocular stereo perception and binocular light perception. Results show that both the stereoacuity and light sensitivity decrease as the retina's eccentricity increases from fovea to periphery. However, the decrease of the stereoacuity is more rapid than that of the light sensitivity. These results suggest that the binocular disparity at the peripheral field should be small, otherwise double images would be observed instead of a stereo view. Based on the results we develop a relative binocular stereoacuity model which can be applied for the design of HMD systems with wide view. 展开更多
关键词 peripheral vision binocular perception virtual reality head mounted display with wide view
下载PDF
Binocular form deprivation influences the visual cortex
15
作者 Mingming Liu Chuanhuang Weng +1 位作者 Hanping Xie Wei Qin 《Neural Regeneration Research》 SCIE CAS CSCD 2012年第34期2713-2718,共6页
a-Amino-3-hydroxy-5-methyl-4-isoxazolepropionic acid receptors are considered to play a crucial role in synaptic plasticity in the developing visual cortex. In this study, we established a rat model of binocular form ... a-Amino-3-hydroxy-5-methyl-4-isoxazolepropionic acid receptors are considered to play a crucial role in synaptic plasticity in the developing visual cortex. In this study, we established a rat model of binocular form deprivation by suturing the rat binocular eyelids before eye-opening at postnatal day 14. During development, the decay time of excitatory postsynaptic currents mediated by a-amino-3- hydroxy-5-methyl-4-isoxazolepropionic acid receptors of normal rats became longer after eye- opening; however, the decay time did not change significantly in binocular form deprivation rats. The peak value in the normal group became gradually larger with age, but there was no significant change in the binocular form deprivation group. These findings indicate that binocular form deprivation influences the properties of excitatory postsynaptic currents mediated by a-amino-3- hydroxy-5-methyl-4-isoxazolepropionic acid receptors in the rat visual cortex around the end of the critical period, indicating that form stimulation is associated with the experience-dependent modification of neuronal synapses in the visual cortex. 展开更多
关键词 a-amino-3-hydroxy-5-methyl-4-isoxazolepropionic acid receptors excitatory postsynaptic currents whole-cell recording visual cortex binocular form deprivation visual development neuraldevelopment regeneration neural regeneration
下载PDF
Binocular vision and abnormal head posture in children when watching television
16
作者 Di Zhang Wei-Hong Zhang +2 位作者 Shu-Zhen Dai Hai-Ying Peng Li-Ya Wang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第5期746-749,共4页
AIM: To determine the association between the binocular vision and an abnormal head posture(AHP)when watching television(TV) in children 7-14 y of age.·METHODS: Fifty normal children in the normal group and... AIM: To determine the association between the binocular vision and an abnormal head posture(AHP)when watching television(TV) in children 7-14 y of age.·METHODS: Fifty normal children in the normal group and 52 children with an AHP when watching TV in the AHP group were tested for spherical equivalents, far and near fusional convergence(FC) and fusional divergence(FD) amplitudes, near point of convergence, far and near heterophoria, accommodative convergence/accommodation ratio and stereoacuity. The values of these tests were compared between the two groups. The independent t test was applied at a confidence level of95%.·RESULTS: The far and near FC amplitudes and far FD amplitudes were lower in the AHP group(the far FC amplitudes: break point 13.6±5.4~△, recovery point 8.7±5.4~△.The near FC amplitudes: break point 14.5 ±7.3~△, recovery point 10. 3 ± 5. 1~△. The far FD amplitudes : break point3.9±2.7~△, recovery point 2.6±2.3~△) compared with those in the normal group(the far FC amplitudes: break point19.1 ±6.2△, recovery point 12.4 ±4.5~△. The near FC amplitudes: break point 22.3 ±8.0~△, recovery point 16.1 ±5.7~△. The far FD amplitudes: break point 7.0 ±2.1~△,recovery point 4.6 ±1.9~△). Other tests presented no statistically significant differences.·CONCLUSION: An association between the reduced FC and FD amplitudes and the AHP in children when watching TV is proposed in the study. This kind of AHP is considered to be an anomalous manifestation which appears in a part of puerile patients of fusional vergence dysfunction. 展开更多
关键词 binocular vision fusional convergence fusional divergence abnormal head posture
下载PDF
Impact of binocular visual field loss on driving performance in glaucoma patients
17
作者 Zhen-Ying Jiang Jing Chen +1 位作者 Jing Yao Shao-Hong Qian 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第1期112-119,共8页
AIM:To evaluate the driving performance in young and middle-aged Chinese glaucoma patients with mild to severe visual field loss compared to those without glaucoma by using a driving simulation test.METHODS:Twenty-nin... AIM:To evaluate the driving performance in young and middle-aged Chinese glaucoma patients with mild to severe visual field loss compared to those without glaucoma by using a driving simulation test.METHODS:Twenty-nine participants were included in this study:nine patients with glaucoma but pass the binocular Esterman visual field test,ten patients with glaucoma and fail the binocular Esterman visual field test,and ten age-matched healthy controls.A driving simulation test was designed as a frequency-based analysis of a lanekeeping task.The total performance error,the controlresponse amplitude and delay were calculated.RESULTS:Esterman visual field test fail group showed the longest delay of control-response among three groups(P=0.02).And the delay in lane-keeping task was significantly associated with inferior field of better-eye(r=0.51,P=0.004)and integrated visual field(r=0.55,P=0.002).CONCLUSION:Young and middle-aged glaucoma patients with binocular visual field loss suffered from a longer delay of response in driving simulation test,while inferior visual field having more impact than superior visual field. 展开更多
关键词 driving simulation binocular visual field loss GLAUCOMA young middle-aged
下载PDF
The Effect of Monocular Blur on the Binocular Visual Field
18
作者 Fusako Fujimura Nobuyuki Shoji 《Open Journal of Ophthalmology》 2018年第1期12-17,共6页
Purpose/Aim: We aimed to investigate the effect of monocular blur on the binocular visual field. Materials and Methods: A total of 13 healthy young volunteers participated in this study. The mean subjective refractive... Purpose/Aim: We aimed to investigate the effect of monocular blur on the binocular visual field. Materials and Methods: A total of 13 healthy young volunteers participated in this study. The mean subjective refractive error of the dominant eye (DE) was -3.33 ± 1.65D, and the non-dominant eye (NDE) was -3.15 ± 2.84D. The DE was determined by using the hole-in-the-card test. The visual field was examined by the Humphrey Visual Field Analyzer using the 30-2 SITA Standard program. The visual field was measured while wearing soft contact lens under three conditions;① both eyes: near vision correction;② DE: near vision correction +3.00D added, NDE: near vision correction;and ③ DE: near vision correction, NDE: near vision correction +3.00D added. The foveal threshold, mean deviation (MD), and pattern standard deviation (PSD) values were investigated. Results: The foveal threshold value (dB) at ①, ②, and ③ was 41.2, 37.8, and 38.1, respectively. The values at ② and ③ were both significantly lower than that at ① (p Conclusion: These results suggest that monocular blur reduced the sensitivity within the binocular visual field. 展开更多
关键词 binocular VISUAL FIELD MONOCULAR BLUR binocular Inhibition Eye DOMINANCE Humphrey VISUAL FIELD Analyze
下载PDF
The binocular intraocular lens power difference in eyes with different axial lengths
19
作者 Ming-Hui Deng Xiao-Gang Wang +1 位作者 Song Chen Xue-Feng Shi 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2022年第6期924-931,共8页
AIM:To investigate the binocular intraocular lens(IOL)power difference in eyes with short,normal,and long axial lengths(AL)using Lenstar LS 900 optical biometry.METHODS:A total of 716(1432 eyes)participants were inclu... AIM:To investigate the binocular intraocular lens(IOL)power difference in eyes with short,normal,and long axial lengths(AL)using Lenstar LS 900 optical biometry.METHODS:A total of 716(1432 eyes)participants were included.The groups were categorized into short(group A:AL<22 mm),normal(group B:22 mm≤AL≤25 mm),and long AL groups(group C:AL>25 mm).The central corneal thickness(CCT),anterior chamber depth(ACD),lens thickness(LT),AL,anterior corneal keratometry,whiteto-white(WTW),pupil diameter(PD),as well as IOL power calculated using embedded Barrett formula were assessed.Bland-Altman plots were used to test the agreement of the binocular parameters.RESULTS:In group A,the CCT of the right eye was significantly thinner than that of the left eye(P=0.044)with a difference of-2±8μm[95%limits of agreement(LoA),-17.8 to 13.2μm].For group B,the PD and IOL power in the right eye were significantly lower than those of the left eye(P=0.001,<0.001)with a difference of-0.05±0.32 mm(95%LoA,-0.68 to 0.58 mm)and-0.18±1.01 D(95%LoA,-2.2 to 1.8 D).The AL of right eye was longer than that of the left eye(P=0.002)with a difference of 0.04±0.25 mm(95%Lo A,-0.45 to 0.52 mm).No significant difference was observed for all the binocular parameters in group C.The percentage of participants with binocular IOL power difference within±0.5 D were 62%(31/50),68.3%(339/496),and 38.8%(66/170)in groups A,B,and C,respectively.CONCLUSION:The binocular parameters related to IOL power are in good agreement,but the binocular IOL power difference of more than half of participants with long AL is more than 0.50 D. 展开更多
关键词 axial length intraocular lens power binocular difference
下载PDF
The Effect of Ocular Dominance on Accommodation and Miosis under Binocular Open Viewing Conditions
20
作者 Fusako Fujimura Tomoya Handa +1 位作者 Takushi Kawamorita Nobuyuki Shoji 《Open Journal of Ophthalmology》 2017年第3期158-166,共9页
Background/Aims: We investigated the relationship between ocular dominance and accommodation on the pupils of the dominant eye and the non-dominant eye under binocular open viewing conditions. Methods: Seventeen healt... Background/Aims: We investigated the relationship between ocular dominance and accommodation on the pupils of the dominant eye and the non-dominant eye under binocular open viewing conditions. Methods: Seventeen healthy young volunteers participated in this study. The dominant eye was determined using the hole-in-the-card test. The objective refraction and pupil diameter were measured under binocular open viewing and monocular single viewing conditions using a binocular open auto-refractor, the WAM-5500 (SHIGIYA MACHINERY WORKS LTD., Hiroshima, Japan). The accommodative response was calculated using the objective refraction, and the rate of miosis was calculated using the pupil diameter. These values were then compared between the dominant and the non-dominant eyes. Results: Under binocular open viewing conditions, the accommodative response in the dominant eye was greater than in the non-dominant eye (p = 0.001). In contrast, under monocular single viewing conditions, there were no differences in the accommodative response between the dominant and non-dominant eyes. In both binocular open viewing and monocular single viewing conditions, there were no differences in the miosis ratio between the dominant and non-dominant eyes. Conclusion: These results suggest that the accommodative response under binocular open viewing conditions is influenced by ocular dominance. 展开更多
关键词 OCULAR DOMINANCE binocular Vision OPEN Viewing Conditions ACCOMMODATION
下载PDF
上一页 1 2 161 下一页 到第
使用帮助 返回顶部