Biodegradable polylactic acid(PLA)melt-blown nonwovens are attractive candidates to replace nondegradable polypropylene melt-blown nonwovens.However,it is still an extremely challenging task to prepare PLA melt-blown ...Biodegradable polylactic acid(PLA)melt-blown nonwovens are attractive candidates to replace nondegradable polypropylene melt-blown nonwovens.However,it is still an extremely challenging task to prepare PLA melt-blown nonwovens with sufficient mechanical properties for practical application.Herein,we report a simple strategy for the large-scale preparation of biodegradable PLA/poly(3-hydroxybutyrate-co-3-hydroxyvalerate)(PHBV)melt-blown nonwovens with high strength and excellent toughness.In this process,a small amount of PHBV is added to PLA to improve the latter’s crystallization rate and crystallinity.In addition,when the PHBV content increases from 0 to 7.5 wt%,the diameters of the PLA/PHBV melt-blown fibers decrease significantly(with the proportion of nanofibers increasing from 7.7%to 42.9%).The resultant PLA/PHBV(5 wt%PHBV)melt-blown nonwovens exhibit the highest mechanical properties.The tensile stress,elongation,and toughness of PLA/PHBV(5 wt%PHBV)melt-blown nonwovens reach 2.5 MPa,45%,and 1.0 MJm3,respectively.More importantly,PLA/PHBV melt-blown nonwovens can be completely degraded into carbon dioxide and water after four months in the soil,making them environmentally friendly.A general tensile-failure model of melt-blown nonwovens is proposed in this study,which may shed light on mechanical performance enhancement for nonwovens.展开更多
Biodegradable implants are critical for regenerative orthopaedic procedures,but they may suffer from too fast corrosion in human-body environment.This necessitates the synthesis of a suitable coating that may improve ...Biodegradable implants are critical for regenerative orthopaedic procedures,but they may suffer from too fast corrosion in human-body environment.This necessitates the synthesis of a suitable coating that may improve the corrosion resistance of these implants without compromising their mechanical integrity.In this study,an AZ91 magnesium alloy,as a representative for a biodegradable Mg implant material,was modified with a thin reduced graphene oxide(RGO)-calcium carbonate(CaCO_(3))composite coating.Detailed analytical and in-vitro electrochemical characterization reveals that this coating significantly improves the corrosion resistance and mechanical integrity,and thus has the potential to greatly extend the related application field.展开更多
The cardiovascular diseases(CVD)continue to be the major threat to global public health over the years,while one of the effective methods to treat CVD is stent intervention.Biomedical magnesium(Mg)alloys have great po...The cardiovascular diseases(CVD)continue to be the major threat to global public health over the years,while one of the effective methods to treat CVD is stent intervention.Biomedical magnesium(Mg)alloys have great potential applications in cardiovascular stents benefit from their excellent biodegradability and absorbability.However,excessive degradation rate and the delayed surface endothelialization still limit their further application.In this study,we modified a Mg-Zn-Y-Nd alloy(ZE21B)by preparing MgF_(2) as the corrosion resistance layer,the dopamine polymer film(PDA)as the bonding layer,and hyaluronic acid(HA)loaded astaxanthin(ASTA)as an important layer to directing the cardiovascular cells fate.The electrochemical test results showed that the MgF_(2)/PDA/HA-ASTA coating improved the corrosion resistance of ZE21B.The cytocompatibility experiments also demonstrated that this novel composite coating also selectively promoted endothelial cells proliferation,inhibited hyperproliferation of smooth muscle cells and adhesion of macrophages.Compared with the HAloaded rapamycin(RAPA)coating,our MgF_(2)/PDA/HA-ASTA coating showed better blood compatibility and cytocompatibility,indicating stronger multi-functions for the ZE21B alloy on cardiovascular application.展开更多
Laser powder bed fusion(L-PBF)has been employed to additively manufacture WE43 magnesium(Mg)alloy biodegradable implants,but WE43 L-PBF samples exhibit excessively rapid corrosion.In this work,dense WE43 L-PBF samples...Laser powder bed fusion(L-PBF)has been employed to additively manufacture WE43 magnesium(Mg)alloy biodegradable implants,but WE43 L-PBF samples exhibit excessively rapid corrosion.In this work,dense WE43 L-PBF samples were built with the relativity density reaching 99.9%.High temperature oxidation was performed on the L-PBF samples in circulating air via various heating temperatures and holding durations.The oxidation and diffusion at the elevated temperature generated a gradient structure composed of an oxide layer at the surface,a transition layer in the middle and the matrix.The oxide layer consisted of rare earth(RE)oxides,and became dense and thick with increasing the holding duration.The matrix was composed ofα-Mg,RE oxides and Mg_(24)RE_(5) precipitates.The precipitates almost disappeared in the transition layer.Enhanced passivation effect was observed in the samples treated by a suitable high temperature oxidation.The original L-PBF samples lost 40%weight after 3-day immersion in Hank’s solution,and broke into fragments after 7-day immersion.The casted and solution treated samples lost roughly half of the weight after 28-day immersion.The high temperature oxidation samples,which were heated at 525℃ for 8 h,kept the structural integrity,and lost only 6.88%weight after 28-day immersion.The substantially improved corrosion resistance was contributed to the gradient structure at the surface.On one hand,the outmost dense layer of RE oxides isolated the corrosive medium;on the other hand,the transition layer considerably inhibited the corrosion owing to the lack of precipitates.Overall,high temperature oxidation provides an efficient,economic and safe approach to inhibit the corrosion of WE43 L-PBF samples,and has promising prospects for future clinical applications.展开更多
Recent advances in functionally graded additive manufacturing(FGAM)technology have enabled the seamless hybridization of multiple functionalities in a single structure.Soft robotics can become one of the largest benef...Recent advances in functionally graded additive manufacturing(FGAM)technology have enabled the seamless hybridization of multiple functionalities in a single structure.Soft robotics can become one of the largest beneficiaries of these advances,through the design of a facile four-dimensional(4D)FGAM process that can grant an intelligent stimuli-responsive mechanical functionality to the printed objects.Herein,we present a simple binder jetting approach for the 4D printing of functionally graded porous multi-materials(FGMM)by introducing rationally designed graded multiphase feeder beds.Compositionally graded cross-linking agents gradually form stable porous network structures within aqueous polymer particles,enabling programmable hygroscopic deformation without complex mechanical designs.Furthermore,a systematic bed design incorporating additional functional agents enables a multi-stimuli-responsive and untethered soft robot with stark stimulus selectivity.The biodegradability of the proposed 4D-printed soft robot further ensures the sustainability of our approach,with immediate degradation rates of 96.6%within 72 h.The proposed 4D printing concept for FGMMs can create new opportunities for intelligent and sustainable additive manufacturing in soft robotics.展开更多
Biodegradable magnesium alloys have been widely used in medical implants. But safety concerns were put forward for the high degradation rate of biodegradable magnesium alloy. The optimal biodegradable magnesium alloys...Biodegradable magnesium alloys have been widely used in medical implants. But safety concerns were put forward for the high degradation rate of biodegradable magnesium alloy. The optimal biodegradable magnesium alloys that give rise to the desired degradation rate hasn’t yet to be defined. Assessing the degradation rate of biodegradable magnesium alloys involves in vitro testing, in vivo testing, numerical modeling, understanding the factors influencing their degradation in physiological environments, biocompatibility testing, and clinical studies. It is important to standardize analytical tools aimed at assessing the degradation rate of biodegradable magnesium alloys. It is advisable to identify the threshold for safe degradation rate of biodegradable magnesium alloys in biomedical applications.展开更多
Current biodegradation timelines show that polyesters take over 200 years to break down. A crucial component of several industries, polyesters are relied upon for materials development and thus require sustainable alt...Current biodegradation timelines show that polyesters take over 200 years to break down. A crucial component of several industries, polyesters are relied upon for materials development and thus require sustainable alternatives. Recent works in generative modeling have made it possible to produce large sets of chemical structures, but current molecular screening methods are expensive, not scalable, and are oversimplified. This work evaluates whether a molecule’s biodegradability potential can be accurately predicted by training a model on recent experimental data. Additionally, three chemical descriptors were evaluated on the final molecules for their effects on biodegradability: molecular structure, bond types, and solubility. A Gradient Boosted Machine was trained on a dataset of 600 molecules and their binary labels on biodegradability. The classification model effectively captured the biodegradability property, yielding an Area Under the Receiver Operating Characteristics, AUROC, of 84% and an Area Under the Precision Recall Curve, or AUPRC, of 87%. Additionally, an existing amortized synthetic tree generation model, SynNet, validated each molecule by showing chemical synthesizability and producing simple and interpretable synthesis pathways. This approach of filtering by prediction and chemical rule interpretation is inexpensive, highly scalable and can capture the necessary complexity. Using this method, novel polyester candidates can be polymerized and produced into sustainable fabrics, reducing environmental stress from textile-reliant industries.展开更多
Background and Objective: In the contemporary practice, the use of drug-eluting stents is still associated with low mortality benefits, restenosis and stent thrombosis. To address these issues, newer generation, thin-...Background and Objective: In the contemporary practice, the use of drug-eluting stents is still associated with low mortality benefits, restenosis and stent thrombosis. To address these issues, newer generation, thin-strut, biodegradable polymer coated stents has been designed. Thus, the aim of the study is to assess the safety and clinical performance of the Everoflex (Sahajanand Medical Technologies Pvt. Ltd., Surat, India), a newer generation biodegradable polymer coated everolimus-eluting stent, in unselected “real-world” patients with coronary artery disease. Methods: It is a multicentre, retrospective, non-randomized, single-arm study enrolling all the consecutive patients who underwent implantation with the Everoflex for coronary artery disease from April 2014 to March 2016. The primary end-point of the study is 30-day major adverse cardiovascular events (MACE) rate, which consists of cardiac death, myocardial infarction, target lesion revascularization and target vessel revascularization. Stent thrombosis was also analyzed and reported. Results: A total of 340 patients were intervened successfully with 395 everolimus eluting stents (1.3 ± 0.6 stents per patient). Out of total patients (58.7 ± 10.5 years), 77.9% were male and comorbidities like diabetes and hypertension were observed in 31.2% and 35.3% patients, respectively. According to ACC/AHA classification, there were 34.4% type B lesions and 53.2% type C lesions, indicating a higher proportion of complexity involved. Moreover, 57.9% patients had multivessel disease and there were 15.4% total occlusions. At 30 days, follow-up was completed in 100% patients. The MACE was found to be 1.5%, which is a composite of 1.2% cardiac death and 0.3% target lesion revascularization. Stent thrombosis at 30 days was found to be 0.3%. Conclusion: The low incidence of MACE and stent thrombosis clearly depicts excellent safety and clinical performance of the Everoflex in unselected real world patients with coronary artery disease.展开更多
[Objective] The aim was to explore application effects of truly biodegradable mulch in farmlands and provide data support for large area spreading on southern potato fields. [Method] The field plot experiments were co...[Objective] The aim was to explore application effects of truly biodegradable mulch in farmlands and provide data support for large area spreading on southern potato fields. [Method] The field plot experiments were conducted to investigate mulch film's weight loss and the effects of using truly biodegradable mulch film on potato yield and agronomic characters. [Result] The emergence rates of truly biodegradable mulch film and black plastic mulch film kept 9.71% and9.27% higher compared with the open field, and yield increased by 30.84% and36.81%. In the potato harvest period, the truly biodegradable mulch films already broke, and mulch film's weight loss rate was 58.62%. It can be completely degraded in the field after some time, and following crops would not be affected. [Conclusion] Truly biodegradable mulch performs significantly in increasing yield and keeps higher in weight-loss rate, so that it has a promising future.展开更多
Thermoplastic starch is a kind of modified starch produced by mixing starch with additives and processing the mixture in an extruder. The mechanical properties, including tensile strength and elongation at break, biod...Thermoplastic starch is a kind of modified starch produced by mixing starch with additives and processing the mixture in an extruder. The mechanical properties, including tensile strength and elongation at break, biodegradability and rheological properties were studied. Glycerol and urea, to some extent, can both decrease the tensile strength and increase percentage elongation at break, because the former acts as a plasticizer and the latter can break down interactions among starch macromolecules. Thermoplastic starch shows thermoplasticity and its melt behaves as a pseudoplastic liquid at a low shear rate. Its biodegrading extent is slightly higher than that of native starch. The molecular weight of starch displays a decreasing tendency after thermoplastic modification.展开更多
Extensive in vitro corrosion test systems have been carried out to simulate the in vivo corrosion behavior of biodegradable metallic materials. Various methods have their own unique benefits and limitations. The corro...Extensive in vitro corrosion test systems have been carried out to simulate the in vivo corrosion behavior of biodegradable metallic materials. Various methods have their own unique benefits and limitations. The corrosion mechanism of biodegradable alloys and in vitro corrosion test systems on biodegradable metallic materials are reviewed, to build a reasonable simulated in vitro test system for mimicking the in vivo animal test from the aspects of electrolyte solution selection, surface roughness influence, test methods and evaluation methodology of corrosion rate. Buffered simulated body fluid containing similar components to human blood plasma should be applied as electrolyte solution, such as simulated body fluid (SBF) and culture medium with serum. Surface roughness of samples and ratio of solution volume to sample surface area should be adopted based on the real implant situation, and the dynamic corrosion is preferred. As to the evaluation methodology of corrosion rate, different methods may complement one another.展开更多
Magnesium alloys have good biocompatibility, but their mechanical properties and corrosion resistance may not be satisfied for using as degradable materials within bone due to its high corrosion rate in the physiologi...Magnesium alloys have good biocompatibility, but their mechanical properties and corrosion resistance may not be satisfied for using as degradable materials within bone due to its high corrosion rate in the physiological environment. Nano β-TCP particles were added into Mg-Zn-Zr alloy to improve its microstructure and the properties. As-extruded Mg-3Zn-0.8Zr alloy and Mg-3Zn-0.8Zr/xβ-TCP (x=0.5%, 1.0% and 1.5%) composites were respectively fabricated. The grains of Mg-Zn-Zr/β-TCP composites were significantly refined. The results of the tensile tests indicate that the ultimate tensile strength and the elongation of composites were improved with the addition of β-TCP. The electrochemical test result in simulation body fluid shows that the corrosion resistance of the composites was strongly enhanced comparing with that of the alloy. The corrosion potential of Mg-3Zn0.8-Zr/1.0β-TCP composite is 1.547 V and its corrosion current density is 1.20×10 6 A/cm 2 .展开更多
[S,S]-Ethylenediaminedisuccinic acid(EDDS),a biodegradable chelant,was used to separate the heavy metals from the sewage sludge based on chemical extraction technology.Under various conditions,the extraction experimen...[S,S]-Ethylenediaminedisuccinic acid(EDDS),a biodegradable chelant,was used to separate the heavy metals from the sewage sludge based on chemical extraction technology.Under various conditions,the extraction experiments were carried out for the sewage sludge from Shanghai Taopu Municipal Wastewater Plant,China.The influences ofpH and the concentration of EDDS on the extraction efficiency for copper(Cu)were discussed.The results showed that EDDS had higher extraction efficiency for Cu from the sewage sludge ...展开更多
Biodegradable stents(BDSs)are an attractive option to avoid ongoing dilation or surgery in patients with benign stenoses of the small and large intestines.The experience with the currently the only BDS for endoscopic ...Biodegradable stents(BDSs)are an attractive option to avoid ongoing dilation or surgery in patients with benign stenoses of the small and large intestines.The experience with the currently the only BDS for endoscopic placement,made of Poly-dioxanone,have shown promising results.However some aspects should be improved as are the fact that BDSs lose their radial force over time due to the degradable material,and that can cause stent-induced mucosal or parenchymal injury.This complication rate and modest clinical efficacy has to be carefully considered in individual patients prior to placement of BDSs.Otherwise,the price of these stents therefore it is nowadays an important limitation.展开更多
BACKGROUND Stent insertion can effective alleviate the symptoms of benign esophageal strictures(BES).Magnesium alloy stents are a good candidate because of biological safety,but show a poor corrosion resistance and a ...BACKGROUND Stent insertion can effective alleviate the symptoms of benign esophageal strictures(BES).Magnesium alloy stents are a good candidate because of biological safety,but show a poor corrosion resistance and a quick loss of mechanical support in vivo.AIM To test the therapeutic and adverse effects of a silicone-covered magnesium alloy biodegradable esophageal stent.METHODS Fifteen rabbits underwent silicone-covered biodegradable magnesium stent insertion into the benign esophageal stricture under fluoroscopic guidance(stent group).The wall reconstruction and tissue reaction of stenotic esophagus in the stent group were compared with those of six esophageal stricture models(control group).Esophagography was performed at 1,2,and 3 weeks.Four,six,and five rabbits in the stent group and two rabbits in the control groups were euthanized,respectively,at each time point for histological examination.RESULTS All stent insertions were well tolerated.The esophageal diameters at immediately,1,2 and 3 wk were 9.8±0.3 mm,9.7±0.7 mm,9.4±0.8 mm,and 9.2±0.5 mm,respectively(vs 4.9±0.3 mm before stent insertion;P<0.05).Magnesium stents migrated in eight rabbits[one at 1 wk(1/15),three at 2 wk(3/11),and four at 3 wk(4/5)].Esophageal wall remodeling(thinner epithelial and smooth muscle layers)was found significantly thinner in the stent group than in the control group(P<0.05).Esophageal injury and collagen deposition following stent insertion were similar and did not differ compared to rabbits with esophageal stricture and normal rabbits(P>0.05).CONCLUSION Esophageal silicone-covered biodegradable magnesium stent insertion is feasible for BES without causing severe injury or tissue reaction.Our study suggests that insertion of silicone-covered magnesium esophageal stent is a promising approach for treating BES.展开更多
The inhibition effects and mechanisms of chlorinated methane and acetylene on methanogenesis in the anaerobic digestion process of the biodegradable wastes were investigated.It was found that both chloroform and acety...The inhibition effects and mechanisms of chlorinated methane and acetylene on methanogenesis in the anaerobic digestion process of the biodegradable wastes were investigated.It was found that both chloroform and acetylene could effectively inhibit methanogens while the biodegradability of the wastes was not affected.Acetylene inhibited the activity of methanogens,while chloroform inhibited metabolic process of methanogenesis.A central composite design(CCD) and response surface regression analysis(RSREG) were employed to determine the optimum conditions and interaction effects of chloroform and acetylene in terms of inhibition effciency,production of volatile fatty acids(VAF) and molar ratio of propionic acid to acetic acid.Chloroform had significant effect on enhancing the production of VFA(F = 121.3;p 〈 0.01),and acetylene promoted the inhibition effciency(F = 99.15;p 〈 0.05) more effectively than chloroform(F = 9.72;p 〉 0.05).In addition,a maximum molar ratio of propionic acid to acetic acid of 1.208 was estimated under the optimum conditions of chloroform concentration of 9.05 mg/kg and acetylene concentration of 3.6×10^-3(V/V).Hence,methanogens in the wastes can be inhibited while the stabilization process of the biodegradable wastes can still work well,as propionic acid generated during the inhibition process could hardly be utilized by methanogens.展开更多
Coronary angioplasty with drug-eluting stent(DES)implantation is currently the most common stent procedure worldwide.Since the introduction of DES,coronary restenosis as well as the incidence of target vessel and targ...Coronary angioplasty with drug-eluting stent(DES)implantation is currently the most common stent procedure worldwide.Since the introduction of DES,coronary restenosis as well as the incidence of target vessel and target lesion revascularization have been significantly reduced.However,the incidence of very late stent thrombosis beyond the first year after stent deployment has more commonly been linked to DES than to baremetal stent(BMS)implantation.Several factors have been associated with very late stent thrombosis after DES implantation,such as delayed healing,inflammation,stent mal-apposition and endothelial dysfunction. Some of these adverse events were associated with the presence of durable polymers,which were essential to allow the elution of the immunosuppressive drug in the first DES designs.The introduction of erodable polymers in DES technology has provided the potential to complete the degradation of the polymer simultaneously or immediately after the release of the immunosuppressive drug,after which a BMS remains in place.Several DES designs with biodegradable(BIO)polymers have been introduced in preclinical and clinical studies, including randomized trials.In this review,we analyze the clinical results from 6 observational and randomized studies with BIO polymers and discuss advantages and disadvantages of this new technology.展开更多
Biodegradable starch/poly (vinyl alcohol)/nano-titanium dioxide (ST/PVA/nano-Ti02) nanocomposite films were prepared via a solution casting method. Their biodegradability, mechanical properties, and thermal proper...Biodegradable starch/poly (vinyl alcohol)/nano-titanium dioxide (ST/PVA/nano-Ti02) nanocomposite films were prepared via a solution casting method. Their biodegradability, mechanical properties, and thermal properties were also studied in this paper. A general full factorial experimental approach was used to determine effective parameters on the mechanical properties of the prepared films. ST/PVA/TiO2 nanocomposites were characterized by scanning electron microscopy (SEM) and X-ray diffraction (XRD). The results of mechanical analysis show that ST/PVA films with higher contents of PVA have much better mechanical properties. In thermal analysis, it is found that the addition of Ti02 nanoparticles improves the thermal stability of the films. SEM micrographs, taken from the fracture surface of samples, illustrate that the addition of PVA makes the film softer and more flexible. The results of soil burial biodegradation indicate that the biodegradability of ST/PVA/TiO2 films strongly depends on the starch proportion in the film matrix. The degradation rate is increased by the addition of starch in the films.展开更多
Biodegradable poly(epsilon-caprolactone-co-p-dioxanone)(PCDO) random copolymers have been synthesized by ring-opening polymerization of epsilon-caprolactone(CL) and p-dioxanone(PDO) under microwave irradiation.The eff...Biodegradable poly(epsilon-caprolactone-co-p-dioxanone)(PCDO) random copolymers have been synthesized by ring-opening polymerization of epsilon-caprolactone(CL) and p-dioxanone(PDO) under microwave irradiation.The effects of irradiation time and different CL/PDO molar feed ratios on the microwave-assisted ring-opening polymerization(MROP) of PCDO have been discussed.The resultant products were characterized by ~1H NMR,GPC and DSC.It was found that the polymerization was completed within 20 min at 140℃.In th...展开更多
基金supported by the National Key Research and Development Program of China(2022YFB3804903 and 2022YFB3804900)the National Natural Science Foundation of China(52273052)+1 种基金the Program of Shanghai Academic/Technology Research Leader(21XD1420100)the International Cooperation Fund of Science and Technology Commission of Shanghai Municipality(21130750100).
文摘Biodegradable polylactic acid(PLA)melt-blown nonwovens are attractive candidates to replace nondegradable polypropylene melt-blown nonwovens.However,it is still an extremely challenging task to prepare PLA melt-blown nonwovens with sufficient mechanical properties for practical application.Herein,we report a simple strategy for the large-scale preparation of biodegradable PLA/poly(3-hydroxybutyrate-co-3-hydroxyvalerate)(PHBV)melt-blown nonwovens with high strength and excellent toughness.In this process,a small amount of PHBV is added to PLA to improve the latter’s crystallization rate and crystallinity.In addition,when the PHBV content increases from 0 to 7.5 wt%,the diameters of the PLA/PHBV melt-blown fibers decrease significantly(with the proportion of nanofibers increasing from 7.7%to 42.9%).The resultant PLA/PHBV(5 wt%PHBV)melt-blown nonwovens exhibit the highest mechanical properties.The tensile stress,elongation,and toughness of PLA/PHBV(5 wt%PHBV)melt-blown nonwovens reach 2.5 MPa,45%,and 1.0 MJm3,respectively.More importantly,PLA/PHBV melt-blown nonwovens can be completely degraded into carbon dioxide and water after four months in the soil,making them environmentally friendly.A general tensile-failure model of melt-blown nonwovens is proposed in this study,which may shed light on mechanical performance enhancement for nonwovens.
文摘Biodegradable implants are critical for regenerative orthopaedic procedures,but they may suffer from too fast corrosion in human-body environment.This necessitates the synthesis of a suitable coating that may improve the corrosion resistance of these implants without compromising their mechanical integrity.In this study,an AZ91 magnesium alloy,as a representative for a biodegradable Mg implant material,was modified with a thin reduced graphene oxide(RGO)-calcium carbonate(CaCO_(3))composite coating.Detailed analytical and in-vitro electrochemical characterization reveals that this coating significantly improves the corrosion resistance and mechanical integrity,and thus has the potential to greatly extend the related application field.
基金For financial support,the authors gratefully acknowledge the National Natural Science Foundation of China(U2004164)the National Key Research and Development Program of China(2018YFC1106703)the Key Projects of the Joint Fund of the National Natural Science Foundation of China(U1804251).
文摘The cardiovascular diseases(CVD)continue to be the major threat to global public health over the years,while one of the effective methods to treat CVD is stent intervention.Biomedical magnesium(Mg)alloys have great potential applications in cardiovascular stents benefit from their excellent biodegradability and absorbability.However,excessive degradation rate and the delayed surface endothelialization still limit their further application.In this study,we modified a Mg-Zn-Y-Nd alloy(ZE21B)by preparing MgF_(2) as the corrosion resistance layer,the dopamine polymer film(PDA)as the bonding layer,and hyaluronic acid(HA)loaded astaxanthin(ASTA)as an important layer to directing the cardiovascular cells fate.The electrochemical test results showed that the MgF_(2)/PDA/HA-ASTA coating improved the corrosion resistance of ZE21B.The cytocompatibility experiments also demonstrated that this novel composite coating also selectively promoted endothelial cells proliferation,inhibited hyperproliferation of smooth muscle cells and adhesion of macrophages.Compared with the HAloaded rapamycin(RAPA)coating,our MgF_(2)/PDA/HA-ASTA coating showed better blood compatibility and cytocompatibility,indicating stronger multi-functions for the ZE21B alloy on cardiovascular application.
基金funded by the National Key Research and Development Program of China (2018YFE0104200)National Natural Science Foundation of China (51875310, 52175274, 82172065)Tsinghua Precision Medicine Foundation
文摘Laser powder bed fusion(L-PBF)has been employed to additively manufacture WE43 magnesium(Mg)alloy biodegradable implants,but WE43 L-PBF samples exhibit excessively rapid corrosion.In this work,dense WE43 L-PBF samples were built with the relativity density reaching 99.9%.High temperature oxidation was performed on the L-PBF samples in circulating air via various heating temperatures and holding durations.The oxidation and diffusion at the elevated temperature generated a gradient structure composed of an oxide layer at the surface,a transition layer in the middle and the matrix.The oxide layer consisted of rare earth(RE)oxides,and became dense and thick with increasing the holding duration.The matrix was composed ofα-Mg,RE oxides and Mg_(24)RE_(5) precipitates.The precipitates almost disappeared in the transition layer.Enhanced passivation effect was observed in the samples treated by a suitable high temperature oxidation.The original L-PBF samples lost 40%weight after 3-day immersion in Hank’s solution,and broke into fragments after 7-day immersion.The casted and solution treated samples lost roughly half of the weight after 28-day immersion.The high temperature oxidation samples,which were heated at 525℃ for 8 h,kept the structural integrity,and lost only 6.88%weight after 28-day immersion.The substantially improved corrosion resistance was contributed to the gradient structure at the surface.On one hand,the outmost dense layer of RE oxides isolated the corrosive medium;on the other hand,the transition layer considerably inhibited the corrosion owing to the lack of precipitates.Overall,high temperature oxidation provides an efficient,economic and safe approach to inhibit the corrosion of WE43 L-PBF samples,and has promising prospects for future clinical applications.
基金supported by National R&D Program through the NRF funded by Ministry of Science and ICT(2021M3D1A2049315)and the Technology Innovation Program(20021909,Development of H2 gas detection films(?0.1%)and process technologies)funded by the Ministry of Trade,Industry&Energy(MOTIE,Korea)supported by the Basic Science Program through the NRF of Korea,funded by the Ministry of Science and ICT,Korea.(Project Number:NRF-2022R1C1C1008845)supported by Basic Science Research Program through the NRF funded by the Ministry of Education(Project Number:NRF-2022R1A6A3A13073158)。
文摘Recent advances in functionally graded additive manufacturing(FGAM)technology have enabled the seamless hybridization of multiple functionalities in a single structure.Soft robotics can become one of the largest beneficiaries of these advances,through the design of a facile four-dimensional(4D)FGAM process that can grant an intelligent stimuli-responsive mechanical functionality to the printed objects.Herein,we present a simple binder jetting approach for the 4D printing of functionally graded porous multi-materials(FGMM)by introducing rationally designed graded multiphase feeder beds.Compositionally graded cross-linking agents gradually form stable porous network structures within aqueous polymer particles,enabling programmable hygroscopic deformation without complex mechanical designs.Furthermore,a systematic bed design incorporating additional functional agents enables a multi-stimuli-responsive and untethered soft robot with stark stimulus selectivity.The biodegradability of the proposed 4D-printed soft robot further ensures the sustainability of our approach,with immediate degradation rates of 96.6%within 72 h.The proposed 4D printing concept for FGMMs can create new opportunities for intelligent and sustainable additive manufacturing in soft robotics.
文摘Biodegradable magnesium alloys have been widely used in medical implants. But safety concerns were put forward for the high degradation rate of biodegradable magnesium alloy. The optimal biodegradable magnesium alloys that give rise to the desired degradation rate hasn’t yet to be defined. Assessing the degradation rate of biodegradable magnesium alloys involves in vitro testing, in vivo testing, numerical modeling, understanding the factors influencing their degradation in physiological environments, biocompatibility testing, and clinical studies. It is important to standardize analytical tools aimed at assessing the degradation rate of biodegradable magnesium alloys. It is advisable to identify the threshold for safe degradation rate of biodegradable magnesium alloys in biomedical applications.
文摘Current biodegradation timelines show that polyesters take over 200 years to break down. A crucial component of several industries, polyesters are relied upon for materials development and thus require sustainable alternatives. Recent works in generative modeling have made it possible to produce large sets of chemical structures, but current molecular screening methods are expensive, not scalable, and are oversimplified. This work evaluates whether a molecule’s biodegradability potential can be accurately predicted by training a model on recent experimental data. Additionally, three chemical descriptors were evaluated on the final molecules for their effects on biodegradability: molecular structure, bond types, and solubility. A Gradient Boosted Machine was trained on a dataset of 600 molecules and their binary labels on biodegradability. The classification model effectively captured the biodegradability property, yielding an Area Under the Receiver Operating Characteristics, AUROC, of 84% and an Area Under the Precision Recall Curve, or AUPRC, of 87%. Additionally, an existing amortized synthetic tree generation model, SynNet, validated each molecule by showing chemical synthesizability and producing simple and interpretable synthesis pathways. This approach of filtering by prediction and chemical rule interpretation is inexpensive, highly scalable and can capture the necessary complexity. Using this method, novel polyester candidates can be polymerized and produced into sustainable fabrics, reducing environmental stress from textile-reliant industries.
文摘Background and Objective: In the contemporary practice, the use of drug-eluting stents is still associated with low mortality benefits, restenosis and stent thrombosis. To address these issues, newer generation, thin-strut, biodegradable polymer coated stents has been designed. Thus, the aim of the study is to assess the safety and clinical performance of the Everoflex (Sahajanand Medical Technologies Pvt. Ltd., Surat, India), a newer generation biodegradable polymer coated everolimus-eluting stent, in unselected “real-world” patients with coronary artery disease. Methods: It is a multicentre, retrospective, non-randomized, single-arm study enrolling all the consecutive patients who underwent implantation with the Everoflex for coronary artery disease from April 2014 to March 2016. The primary end-point of the study is 30-day major adverse cardiovascular events (MACE) rate, which consists of cardiac death, myocardial infarction, target lesion revascularization and target vessel revascularization. Stent thrombosis was also analyzed and reported. Results: A total of 340 patients were intervened successfully with 395 everolimus eluting stents (1.3 ± 0.6 stents per patient). Out of total patients (58.7 ± 10.5 years), 77.9% were male and comorbidities like diabetes and hypertension were observed in 31.2% and 35.3% patients, respectively. According to ACC/AHA classification, there were 34.4% type B lesions and 53.2% type C lesions, indicating a higher proportion of complexity involved. Moreover, 57.9% patients had multivessel disease and there were 15.4% total occlusions. At 30 days, follow-up was completed in 100% patients. The MACE was found to be 1.5%, which is a composite of 1.2% cardiac death and 0.3% target lesion revascularization. Stent thrombosis at 30 days was found to be 0.3%. Conclusion: The low incidence of MACE and stent thrombosis clearly depicts excellent safety and clinical performance of the Everoflex in unselected real world patients with coronary artery disease.
基金Supported by Guangzhou Science and Technology Project(2013Y2-00111)Special Program of Public Interest Research and Capacity Building Special Program in Guangdong Province(2014B030303004)~~
文摘[Objective] The aim was to explore application effects of truly biodegradable mulch in farmlands and provide data support for large area spreading on southern potato fields. [Method] The field plot experiments were conducted to investigate mulch film's weight loss and the effects of using truly biodegradable mulch film on potato yield and agronomic characters. [Result] The emergence rates of truly biodegradable mulch film and black plastic mulch film kept 9.71% and9.27% higher compared with the open field, and yield increased by 30.84% and36.81%. In the potato harvest period, the truly biodegradable mulch films already broke, and mulch film's weight loss rate was 58.62%. It can be completely degraded in the field after some time, and following crops would not be affected. [Conclusion] Truly biodegradable mulch performs significantly in increasing yield and keeps higher in weight-loss rate, so that it has a promising future.
文摘Thermoplastic starch is a kind of modified starch produced by mixing starch with additives and processing the mixture in an extruder. The mechanical properties, including tensile strength and elongation at break, biodegradability and rheological properties were studied. Glycerol and urea, to some extent, can both decrease the tensile strength and increase percentage elongation at break, because the former acts as a plasticizer and the latter can break down interactions among starch macromolecules. Thermoplastic starch shows thermoplasticity and its melt behaves as a pseudoplastic liquid at a low shear rate. Its biodegrading extent is slightly higher than that of native starch. The molecular weight of starch displays a decreasing tendency after thermoplastic modification.
基金Project(2012CB619102) supported by National Basic Research Program of ChinaProject(31070847) supported by National Natural Science Foundation of China
文摘Extensive in vitro corrosion test systems have been carried out to simulate the in vivo corrosion behavior of biodegradable metallic materials. Various methods have their own unique benefits and limitations. The corrosion mechanism of biodegradable alloys and in vitro corrosion test systems on biodegradable metallic materials are reviewed, to build a reasonable simulated in vitro test system for mimicking the in vivo animal test from the aspects of electrolyte solution selection, surface roughness influence, test methods and evaluation methodology of corrosion rate. Buffered simulated body fluid containing similar components to human blood plasma should be applied as electrolyte solution, such as simulated body fluid (SBF) and culture medium with serum. Surface roughness of samples and ratio of solution volume to sample surface area should be adopted based on the real implant situation, and the dynamic corrosion is preferred. As to the evaluation methodology of corrosion rate, different methods may complement one another.
基金Project(51071108)supported by the National Natural Science Foundation of ChinaProject(09JCZDJC18500)supported by the Key Project of Natural Science Foundation of Tianjin,China
文摘Magnesium alloys have good biocompatibility, but their mechanical properties and corrosion resistance may not be satisfied for using as degradable materials within bone due to its high corrosion rate in the physiological environment. Nano β-TCP particles were added into Mg-Zn-Zr alloy to improve its microstructure and the properties. As-extruded Mg-3Zn-0.8Zr alloy and Mg-3Zn-0.8Zr/xβ-TCP (x=0.5%, 1.0% and 1.5%) composites were respectively fabricated. The grains of Mg-Zn-Zr/β-TCP composites were significantly refined. The results of the tensile tests indicate that the ultimate tensile strength and the elongation of composites were improved with the addition of β-TCP. The electrochemical test result in simulation body fluid shows that the corrosion resistance of the composites was strongly enhanced comparing with that of the alloy. The corrosion potential of Mg-3Zn0.8-Zr/1.0β-TCP composite is 1.547 V and its corrosion current density is 1.20×10 6 A/cm 2 .
文摘[S,S]-Ethylenediaminedisuccinic acid(EDDS),a biodegradable chelant,was used to separate the heavy metals from the sewage sludge based on chemical extraction technology.Under various conditions,the extraction experiments were carried out for the sewage sludge from Shanghai Taopu Municipal Wastewater Plant,China.The influences ofpH and the concentration of EDDS on the extraction efficiency for copper(Cu)were discussed.The results showed that EDDS had higher extraction efficiency for Cu from the sewage sludge ...
文摘Biodegradable stents(BDSs)are an attractive option to avoid ongoing dilation or surgery in patients with benign stenoses of the small and large intestines.The experience with the currently the only BDS for endoscopic placement,made of Poly-dioxanone,have shown promising results.However some aspects should be improved as are the fact that BDSs lose their radial force over time due to the degradable material,and that can cause stent-induced mucosal or parenchymal injury.This complication rate and modest clinical efficacy has to be carefully considered in individual patients prior to placement of BDSs.Otherwise,the price of these stents therefore it is nowadays an important limitation.
基金Supported by the National Natural Science Foundation of China,No.81371659,No.81571773,and No.81771943Shanghai Municipal Health and Family Planning Commission,No.201640191
文摘BACKGROUND Stent insertion can effective alleviate the symptoms of benign esophageal strictures(BES).Magnesium alloy stents are a good candidate because of biological safety,but show a poor corrosion resistance and a quick loss of mechanical support in vivo.AIM To test the therapeutic and adverse effects of a silicone-covered magnesium alloy biodegradable esophageal stent.METHODS Fifteen rabbits underwent silicone-covered biodegradable magnesium stent insertion into the benign esophageal stricture under fluoroscopic guidance(stent group).The wall reconstruction and tissue reaction of stenotic esophagus in the stent group were compared with those of six esophageal stricture models(control group).Esophagography was performed at 1,2,and 3 weeks.Four,six,and five rabbits in the stent group and two rabbits in the control groups were euthanized,respectively,at each time point for histological examination.RESULTS All stent insertions were well tolerated.The esophageal diameters at immediately,1,2 and 3 wk were 9.8±0.3 mm,9.7±0.7 mm,9.4±0.8 mm,and 9.2±0.5 mm,respectively(vs 4.9±0.3 mm before stent insertion;P<0.05).Magnesium stents migrated in eight rabbits[one at 1 wk(1/15),three at 2 wk(3/11),and four at 3 wk(4/5)].Esophageal wall remodeling(thinner epithelial and smooth muscle layers)was found significantly thinner in the stent group than in the control group(P<0.05).Esophageal injury and collagen deposition following stent insertion were similar and did not differ compared to rabbits with esophageal stricture and normal rabbits(P>0.05).CONCLUSION Esophageal silicone-covered biodegradable magnesium stent insertion is feasible for BES without causing severe injury or tissue reaction.Our study suggests that insertion of silicone-covered magnesium esophageal stent is a promising approach for treating BES.
基金supported by the National Hi-Tech Research and Development Program (863) of China (No.2007AA06Z349)the Natural Science Foundation Project of Chongqing (No.CSTC2008BB7333&7332)the State Key Laboratory of Pollution Control and Resource Reuse (No.PCRRF08006)
文摘The inhibition effects and mechanisms of chlorinated methane and acetylene on methanogenesis in the anaerobic digestion process of the biodegradable wastes were investigated.It was found that both chloroform and acetylene could effectively inhibit methanogens while the biodegradability of the wastes was not affected.Acetylene inhibited the activity of methanogens,while chloroform inhibited metabolic process of methanogenesis.A central composite design(CCD) and response surface regression analysis(RSREG) were employed to determine the optimum conditions and interaction effects of chloroform and acetylene in terms of inhibition effciency,production of volatile fatty acids(VAF) and molar ratio of propionic acid to acetic acid.Chloroform had significant effect on enhancing the production of VFA(F = 121.3;p 〈 0.01),and acetylene promoted the inhibition effciency(F = 99.15;p 〈 0.05) more effectively than chloroform(F = 9.72;p 〉 0.05).In addition,a maximum molar ratio of propionic acid to acetic acid of 1.208 was estimated under the optimum conditions of chloroform concentration of 9.05 mg/kg and acetylene concentration of 3.6×10^-3(V/V).Hence,methanogens in the wastes can be inhibited while the stabilization process of the biodegradable wastes can still work well,as propionic acid generated during the inhibition process could hardly be utilized by methanogens.
文摘Coronary angioplasty with drug-eluting stent(DES)implantation is currently the most common stent procedure worldwide.Since the introduction of DES,coronary restenosis as well as the incidence of target vessel and target lesion revascularization have been significantly reduced.However,the incidence of very late stent thrombosis beyond the first year after stent deployment has more commonly been linked to DES than to baremetal stent(BMS)implantation.Several factors have been associated with very late stent thrombosis after DES implantation,such as delayed healing,inflammation,stent mal-apposition and endothelial dysfunction. Some of these adverse events were associated with the presence of durable polymers,which were essential to allow the elution of the immunosuppressive drug in the first DES designs.The introduction of erodable polymers in DES technology has provided the potential to complete the degradation of the polymer simultaneously or immediately after the release of the immunosuppressive drug,after which a BMS remains in place.Several DES designs with biodegradable(BIO)polymers have been introduced in preclinical and clinical studies, including randomized trials.In this review,we analyze the clinical results from 6 observational and randomized studies with BIO polymers and discuss advantages and disadvantages of this new technology.
基金financial support by Iran Nanotechnology Initiative Council
文摘Biodegradable starch/poly (vinyl alcohol)/nano-titanium dioxide (ST/PVA/nano-Ti02) nanocomposite films were prepared via a solution casting method. Their biodegradability, mechanical properties, and thermal properties were also studied in this paper. A general full factorial experimental approach was used to determine effective parameters on the mechanical properties of the prepared films. ST/PVA/TiO2 nanocomposites were characterized by scanning electron microscopy (SEM) and X-ray diffraction (XRD). The results of mechanical analysis show that ST/PVA films with higher contents of PVA have much better mechanical properties. In thermal analysis, it is found that the addition of Ti02 nanoparticles improves the thermal stability of the films. SEM micrographs, taken from the fracture surface of samples, illustrate that the addition of PVA makes the film softer and more flexible. The results of soil burial biodegradation indicate that the biodegradability of ST/PVA/TiO2 films strongly depends on the starch proportion in the film matrix. The degradation rate is increased by the addition of starch in the films.
文摘Biodegradable poly(epsilon-caprolactone-co-p-dioxanone)(PCDO) random copolymers have been synthesized by ring-opening polymerization of epsilon-caprolactone(CL) and p-dioxanone(PDO) under microwave irradiation.The effects of irradiation time and different CL/PDO molar feed ratios on the microwave-assisted ring-opening polymerization(MROP) of PCDO have been discussed.The resultant products were characterized by ~1H NMR,GPC and DSC.It was found that the polymerization was completed within 20 min at 140℃.In th...