期刊文献+
共找到225篇文章
< 1 2 12 >
每页显示 20 50 100
Prevention the fever of NHTR reactions using blood transfusion set with leucocyte removal filter 被引量:1
1
《中国输血杂志》 CAS CSCD 2001年第S1期335-,共1页
关键词 Prevention the fever of NHTR reactions using blood transfusion set with leucocyte removal filter
下载PDF
An Improved Method for Automatic Retinal Blood Vessel Vascular Segmentation Using Gabor Filter
2
作者 Nalan Karunanayake Nihal D. Kodikara 《Open Journal of Medical Imaging》 2015年第4期204-213,共10页
Early detection of Non-Proliferative Diabetic Retinopathy (NDPR) is currently a highly interested research area in biomedical imaging. Ophthalmologists discover NDPR by observing the configuration of the vessel vascul... Early detection of Non-Proliferative Diabetic Retinopathy (NDPR) is currently a highly interested research area in biomedical imaging. Ophthalmologists discover NDPR by observing the configuration of the vessel vascular network deliberately. Therefore, a computerized automatic system for the segmentation of vessel system will be an assist for ophthalmologists in order to detect an early stage of retinopathy. In this research, region based retinal vascular segmentation approach is suggested. In the steps of processing, the illumination variation of the fundus image is adjusted by using the point operators. Then, the edge features of the vessels are enhanced by applying the Gabor Filter. Finally, the region growing method with automatic seed point selection is used to extract the vessel network from the image background. The experiments of the proposed algorithm are conducted on DRIVE dataset, which is an open access dataset. Results obtain an accuracy of 94.9% over the dataset that has been used. 展开更多
关键词 DIABETIC RETINOPATHY blood Vessel Segmentaion Retinul FUNDUS Image GABOR filter Region Growing Point Operators Illumination Variation
下载PDF
甲磺酸萘莫司他在高出血风险患者连续性血液净化中的抗凝应用效果观察
3
作者 卢文婷 向淑麟 +4 位作者 任彦文 胡琨琳 庞静 莫丽 熊滨 《中国临床新医学》 2024年第1期74-78,共5页
目的 观察甲磺酸萘莫司他(NM)在高出血风险患者连续性血液净化(CBP)中的抗凝应用效果。方法 回顾性收集2023年1月至3月广西壮族自治区人民医院重症医学科收治的34例需要进行CBP的有高出血风险重症患者的临床资料,根据抗凝剂使用情况将... 目的 观察甲磺酸萘莫司他(NM)在高出血风险患者连续性血液净化(CBP)中的抗凝应用效果。方法 回顾性收集2023年1月至3月广西壮族自治区人民医院重症医学科收治的34例需要进行CBP的有高出血风险重症患者的临床资料,根据抗凝剂使用情况将其分为NM组(10例)、枸橼酸钠组(10例)和低分子量肝素组(14例)。比较三组滤器寿命以及临床显著出血事件和其他不良事件发生情况。结果 NM组、枸橼酸钠组和低分子量肝素组的滤器寿命分别为40.00(17.00,51.00)h、36.00(22.00,60.00)h和51.00(45.00,61.50)h,三组比较差异无统计学意义(H=2.096,P=0.351)。在抗凝过程中,NM组无临床显著出血事件发生,枸橼酸钠组和低分子量肝素组分别有3例(30.00%)和4例(28.57%)患者发生临床显著出血事件,三组临床显著出血事件发生率比较差异有统计学意义(χ^(2)=14.171,P=0.001)。低分子量肝素组发生继发性血小板减少6例。NM组未发生过敏反应、高钾血症和粒细胞缺乏症等NM输注相关的不良反应。枸橼酸钠组未发生枸橼酸蓄积、枸橼酸中毒等不良反应。三组患者均未观察到血栓栓塞事件。结论 NM的抗凝效果与枸橼酸钠、低分子量肝素抗凝效果相当,且临床显著出血事件发生率更低,在高出血风险患者中应用的安全性良好。 展开更多
关键词 甲磺酸萘莫司他 枸橼酸钠抗凝剂 低分子量肝素 连续性血液净化 滤器寿命 出血
下载PDF
基于改进BERT模型的连续血压的预测方法研究
4
作者 郭子玉 周亚晶 《黑龙江大学自然科学学报》 CAS 2024年第2期157-162,共6页
目前高血压已成为严重危害全球公共健康的重大问题。区别于传统的侵入式和袖带法的血压测量方式,为实时监测血压并助力早期诊断,本文专注于研究脉搏波波形与血压之间的内在关系,并提出了一种使用脉搏波的基于改进BERT(Bidirectional enc... 目前高血压已成为严重危害全球公共健康的重大问题。区别于传统的侵入式和袖带法的血压测量方式,为实时监测血压并助力早期诊断,本文专注于研究脉搏波波形与血压之间的内在关系,并提出了一种使用脉搏波的基于改进BERT(Bidirectional encoder representationns from transformers)模型的血压预测方法。方法首先应用巴特沃斯滤波器对原始脉搏波信号进行滤波预处理并周期性划分,然后结合深度学习技术,采用改进后的BERT模型,对划分后的脉搏波周期数据进行特征提取和分析。为验证本方法预测的有效性和准确性,采用MIMIC-Ⅲ数据库的数据进行实验。实验结果表明,本方法可以有效预测血压值,完全满足英国高血压学会的A类标准。通过深入研究脉搏波与血压的关系,本文改进BERT模型为高血压的预测与诊断提供了新的技术手段。 展开更多
关键词 血压预测 脉搏波 巴特沃斯滤波 改进BERT模型
下载PDF
基于广义可扩展RPCA滤波的超快超声脑血流与功能成像方法研究
5
作者 吴浩田 闫少渊 +1 位作者 许凯亮 他得安 《仪器仪表学报》 EI CAS CSCD 北大核心 2024年第6期188-197,共10页
开发高分辨和高灵敏度的小血管可视化技术,对相关组织病变的早期诊断和治疗监测具有重要的临床意义。不同于传统聚焦超声,超快超声多普勒(μDoppler)成像技术凭借数千帧的成像帧率,可检测到小血流的瞬时变化。组织杂波滤除和噪声抑制对... 开发高分辨和高灵敏度的小血管可视化技术,对相关组织病变的早期诊断和治疗监测具有重要的临床意义。不同于传统聚焦超声,超快超声多普勒(μDoppler)成像技术凭借数千帧的成像帧率,可检测到小血流的瞬时变化。组织杂波滤除和噪声抑制对于μDoppler的成像质量至关重要。常用的杂波滤除方法为奇异值分解(SVD)方法,该方法利用信号时空相干性差异可快速实现组织杂波和血流信号分离,然而无法有效抑制噪声。本研究创新性提出了一种基于广义可扩展的鲁棒主成分分析(GSRPCA)的杂波滤除方法,使用Schatten p范数和lq范数来加强鲁棒主成分分析(RPCA)模型的低秩约束和稀疏约束,增强了小血流信号的提取能力。大鼠脑血流成像结果表明,GSRPCA能够提升功率多普勒成像中血管的成像质量,相较SVD提高信噪比约20 dB,且提高对比噪声比约10 dB。大鼠超声脑功能成像结果表明,GSRPCA能够提升小血管血容量动态检测的灵敏度。相关方法对超快超声成像杂波滤除的研究具有一定借鉴意义。 展开更多
关键词 超快超声 杂波滤除 广义可扩展RPCA 脑血流 功能成像
下载PDF
超声血流定量参数结合BRAF对桥本甲状腺炎合并甲状腺癌的诊断价值
6
作者 张寅 唐立钧 +2 位作者 陈晓丽 李振 徐樱 《局解手术学杂志》 2024年第7期637-641,共5页
目的分析超声血流定量参数结合鼠类肉瘤滤过性毒菌致癌同源体B(BRAF)基因突变检测对桥本甲状腺炎(HT)合并甲状腺癌的诊断价值。方法以2020年6月至2022年6月于南京医科大学附属逸夫医院就诊的HT合并甲状腺结节患者86例为研究对象,依据病... 目的分析超声血流定量参数结合鼠类肉瘤滤过性毒菌致癌同源体B(BRAF)基因突变检测对桥本甲状腺炎(HT)合并甲状腺癌的诊断价值。方法以2020年6月至2022年6月于南京医科大学附属逸夫医院就诊的HT合并甲状腺结节患者86例为研究对象,依据病理检查结果,将合并甲状腺癌的患者为恶性组(n=26),将合并甲状腺良性结节患者为良性组(n=60)。恶性组患者中依据淋巴结转移情况分为转移组(n=10)和未转移组(n=16)。所有研究对象均接受彩色多普勒超声检查及BRAF基因突变检测,对比良、恶性组患者搏动指数(PI)、阻力指数(RI)、血流频谱收缩期峰值速度(S)、舒张末期血流速度(D)、收缩期峰值速度与舒张末期血流速度比值(S/D)、BRAF基因突变情况;对比转移组与未转移组患者彩色多普勒血流显像(CDFI)血流检出率、2~3级血流信号检出率及BRAF基因突变情况,以受试者工作特征(ROC)曲线评价上述血流参数与BRAF基因突变对HT合并甲状腺癌的诊断价值,并评估上述指标及BRAF基因突变对甲状腺癌淋巴结转移的诊断价值。结果恶性组患者的PI、RI、S、D、S/D及BRAF基因突变阳性率高于良性组(P<0.05);转移组患者的CDFI血流检出率、2~3级血流信号检出率及BRAF基因突变阳性率高于未转移组(P<0.05)。ROC曲线分析结果显示,RI、PI、S、D、S/D及BRAF基因突变联合评估HT合并甲状腺癌的曲线下面积(AUC)为0.951,敏感度为88.46%,特异度为93.33%,联合评估效能优于各指标单独评估;同时CDFI血流检出率、2~3级血流信号检出率及BRAF基因突变联合评估甲状腺癌淋巴结转移的AUC为0.938,联合评估效能优于各指标单独评估。结论超声血流定量参数结合BRAF基因突变对HT合并甲状腺癌及淋巴结转移均具有一定的评估价值,且各指标联合评估效能更佳。 展开更多
关键词 桥本甲状腺炎 甲状腺癌 诊断价值 超声血流定量参数 鼠类肉瘤滤过性毒菌致癌同源体B 淋巴结转移
下载PDF
基于预警理念的过程质量控制在ICU连续性血液净化患者中的应用效果分析
7
作者 周丽华 《智慧健康》 2024年第14期177-179,183,共4页
目的 探讨以预警理念为基础的过程质量控制应用于重症加强护理病房(ICU)连续性血液净化(CBP)患者的效果。方法 选择本院2020年9月—2022年9月收治的50例ICU CBP患者作为研究对象,按随机数字表法分为对照组和观察组,各25例。对照组予以... 目的 探讨以预警理念为基础的过程质量控制应用于重症加强护理病房(ICU)连续性血液净化(CBP)患者的效果。方法 选择本院2020年9月—2022年9月收治的50例ICU CBP患者作为研究对象,按随机数字表法分为对照组和观察组,各25例。对照组予以常规干预,观察组在对照组基础上联合基于预警理念的过程质量控制。观察两组的报警频次与治疗时长、过滤器凝血发生情况、并发症、下机情况。结果 观察组的报警频次少于对照组,治疗时长长于对照组(P<0.05)。两组0~7h过滤器凝血发生率的对比差异无统计学意义(P>0.05),观察组8~23h、>24h过滤器凝血发生率均低于对照组(P<0.05)。观察组并发症发生率低于对照组(P<0.05)。观察组的非计划下机发生率低于对照组(P<0.05)。结论 以预警理念为基础的过程质量控制可减少ICU CBP患者治疗过程中的报警次数,并减少不良事件和并发症的发生,进而减少非计划下机情况,延长治疗时间。 展开更多
关键词 预警理念 连续性血液净化 过程质量控制 过滤器凝血
下载PDF
Controversy over the use of intraoperative blood salvage autotransfusion during liver transplantation for hepatocellular carcinoma patients 被引量:9
8
作者 Bo Zhai Xue-Ying Sun 《World Journal of Gastroenterology》 SCIE CAS 2013年第22期3371-3374,共4页
Intraoperative blood salvage autotransfusion (IBSA) is used in various surgical procedures. However, because of the risk of reinfusion of salvaged blood contaminated by tumor cells, the use of IBSA in hepatocellular c... Intraoperative blood salvage autotransfusion (IBSA) is used in various surgical procedures. However, because of the risk of reinfusion of salvaged blood contaminated by tumor cells, the use of IBSA in hepatocellular carcinoma (HCC) patients undergoing liver transplantation (LT) is controversial. The critical points include whether tumor cells can be cleared by IBSA, whether IBSA increases the risk of recurrence or metastasis, and what are the indications for IBSA. Moreover, is it warranted to take the risk of tumor dissemination by using IBSA to avoid allogeneic blood transfusion? Do the remaining tumor cells after additional filtration by leukocyte depletion filters still possess potential tumorigenicity? Does IBSA always work well? We have reviewed the literature and tried to address these questions. The available data indicate that IBSA is safe in LT for HCC, but randomized, controlled and prospective trials are urgently required to clarify the uncertainty. 展开更多
关键词 INTRAOPERATIVE blood SALVAGE AUTOTRANSFUSION Liver transplantation Hepatocellular carcinoma LEUKOCYTE depletion filters ALLOGENEIC blood transfusion
下载PDF
基于血管模型的网格平滑算法研究
9
作者 程前 谢勤岚 《计量与测试技术》 2024年第4期109-112,共4页
血管三维模型是诊断心血管疾病的重要辅助参考,但表面存在的较多噪声会对诊断产生一定影响,需进行网格平滑。根据现有网格平滑算法,保留清晰特征和减小体积收缩仍具有挑战性。因此,本文提出一种组合平滑算法,并将其应用于人体不同组织... 血管三维模型是诊断心血管疾病的重要辅助参考,但表面存在的较多噪声会对诊断产生一定影响,需进行网格平滑。根据现有网格平滑算法,保留清晰特征和减小体积收缩仍具有挑战性。因此,本文提出一种组合平滑算法,并将其应用于人体不同组织结构的三维模型中进行验证。结果表明:该算法结合曲面重建与联合双边滤波,可实现去除噪声,并保持特征,减轻收缩。 展开更多
关键词 血管三维模型 三维重建 网格平滑 引导法向滤波 联合双边滤波
下载PDF
Automatic detection of multiple oriented blood vessels in retinal images
10
作者 P. C. Siddalingaswamy K. Gopalakrishna Prabhu 《Journal of Biomedical Science and Engineering》 2010年第1期101-107,共7页
Automatic segmentation of the vasculature in retinal images is important in the detection of diabetic retinopathy that affects the morphology of the blood vessel tree. In this paper, a hybrid method for efficient segm... Automatic segmentation of the vasculature in retinal images is important in the detection of diabetic retinopathy that affects the morphology of the blood vessel tree. In this paper, a hybrid method for efficient segmentation of multiple oriented blood vessels in colour retinal images is proposed. Initially, the appearance of the blood vessels are enhanced and background noise is suppressed with the set of real component of a complex Gabor filters. Then the vessel pixels are detected in the vessel enhanced image using entropic thresholding based on gray level co-occurrence matrix as it takes into account the spatial distribution of gray levels and preserving the spatial structures. The performance of the method is illustrated on two sets of retinal images from publicly available DRIVE (Digital Retinal Images for Vessel Extraction) and Hoover’s databases. For DRIVE database, the blood vessels are detected with sensitivity of 86.47±3.6 (Mean±SD) and specificity of 96±1.01. 展开更多
关键词 blood VESSEL Segmentation GABOR filter Co-Occurence Matrix DIABETIC Retinopathy.
下载PDF
A Hybrid De-Noising Method on LASCA Images of Blood Vessels
11
作者 Cong Wu Nengyun Feng +1 位作者 Koichi Harada Pengcheng Li 《Journal of Signal and Information Processing》 2012年第1期92-97,共6页
A de-noising approach is proposed that based on the combination of wiener filtering, nonlinear filtering and wavelet fusion, which de-noise the LASCA (LAser Speckle Contrast Analysis) image of blood vessels in Small A... A de-noising approach is proposed that based on the combination of wiener filtering, nonlinear filtering and wavelet fusion, which de-noise the LASCA (LAser Speckle Contrast Analysis) image of blood vessels in Small Animals. The approach first performs laser spectral contrast analysis on brain blood flow in rats, get their spatial and temporal contrast images. Then, a de-noising filtering method is proposed to deal with noise in LASCA. The image restoration is achieved by applying the proposed admixture filtering, and the subjective estimation and objective estimation are given to the de-noising images. As our experimental results shown, the proposed method provides clearer subjective sense and improved to over 25 db for PSNR. 展开更多
关键词 Brain blood Flow WAVELET Fusion HYBRID filterING Laser SPECKLE CONTRAST Imaging
下载PDF
Electromagnetism, Blood Flow and Coagulation
12
作者 Merab Beraia Guram Beraia 《Journal of Biomedical Science and Engineering》 CAS 2022年第7期187-197,共11页
There is a lot of uncertainty in the theory of hemodynamics. The amount of work need to displace the blood in the systemic circulation, exceeds the work done by the left ventricle. With this, blood recovers increased ... There is a lot of uncertainty in the theory of hemodynamics. The amount of work need to displace the blood in the systemic circulation, exceeds the work done by the left ventricle. With this, blood recovers increased flow resistance between the heartbeats with the Womersley number alterations in the rhythm of the accompanying electrocardiogram (ECG). Viscoelastic transformation is heavily expressed in coagulation. There must be a relationship between the ECG and blood transient flow resistance. The influence of the electromagnetic field on blood coagulation was studied. Venous blood was affected by the oscillated electromagnetic field (500 - 5000 Hz), with the square wave input signal in 25 healthy individuals (15 males, 10 females in the age 18 - 57 years). Electromagnetic irradiation (EMI) time of the sample 3 - 10 min. Hypocoagulation in normal blood samples was revealed (decreased quantity of Platelets up to 10 - 23 × 10<sup>9</sup>/L, Prothrombin index up to 9% - 10%, Fibrinogen concentration up to 0.20 - 0.21 g/L) and thrombolysis after the blood stasis. Ac electric field from the myocardial depolarization initiates electroacoustic phenomena. An emerging repulsing electromagnetic force acts on the red blood cells (RBC) and in addition to the pulse pressure from the heart, promotes blood motion and viscoelastic changes. The alterations of the blood inertial and elasticity, in addition to hemodynamics, are facilitated by the magnetic features of the hemoglobin. The external electromagnetic signal can manage the blood coagulation process, including thrombolysis. 展开更多
关键词 Viscoelastic blood Flow COAGULATION Parcel Resident Time Electromagnetic Force Information filter
下载PDF
白细胞过滤器对红细悬液中血小板的去除效率 被引量:1
13
作者 刘浩强 彭琳 +4 位作者 林宇霆 冯宝莹 巴桑 嘎玛格列 陆英 《中山大学学报(医学科学版)》 CAS CSCD 北大核心 2023年第5期835-839,共5页
【目的】观察不同储存时期红细胞悬液中血小板数量的变化,探讨白细胞过滤器对红细胞悬液中的血小板去除效率。【方法】将58份红细胞悬液根据储存时间不同分为4组:1周组(16份),2周组(16份),3周组(14份),4周组(12份),将四组红细胞悬液通... 【目的】观察不同储存时期红细胞悬液中血小板数量的变化,探讨白细胞过滤器对红细胞悬液中的血小板去除效率。【方法】将58份红细胞悬液根据储存时间不同分为4组:1周组(16份),2周组(16份),3周组(14份),4周组(12份),将四组红细胞悬液通过白细胞过滤器过滤,获取过滤前后的样本,用全自动血细胞计数仪检测血小板计数,计算出血小板的去除率。过滤前红细胞悬液标本制成血细胞涂片,用吉姆萨染色液染色,显微镜下观察血小板的形态。【结果】四组红细胞悬液中过滤前血小板的计数分别为(286.5±62.34)×10^(9)/L、(238.0±57.37)×10^(9)/L、(193.6±56.21)×10^(9)/L和(167.8±24.76)×10^(9)/L,储存3周(P<0.01)和4周(P<0.0001)组血液中的血小板计数明显低于储存1周组。不同储存时期红细胞悬液血细胞涂片中,均可以观察到成群分布和散在分布的形态正常的血小板。4组红细胞悬液的血小板去除率分别为(80.13±9.06)%,(76.41±10.13)%,(77.78±9.30)%和(70.63±9.39)%,各组之间血小板去除率比较差异无统计学意义(P>0.05)。【结论】红细胞悬液中的血小板计数随着储存时间的延长而逐渐降低,而储存后期(3周和4周)仍保存有大部分的血小板,白细胞过滤器能够去除其中的绝大多数血小板,而且各组间去除效率相似。 展开更多
关键词 红细胞悬液 白细胞过滤器 储存时间 血小板去除 效率
下载PDF
术前自体血存储联合白细胞过滤器血液回输在体外循环心脏手术中的应用研究 被引量:2
14
作者 卓海珍 黄周亮 +1 位作者 卢佳轩 陈林 《医师在线》 2023年第7期3-7,共5页
目的研究术前自体血存储联合白细胞过滤器血液回输在体外循环心脏手术中的应用效果。方法将2021年5月~2022年9月于我院拟行全身麻醉体外循环下心脏直视手术的80例患者纳入研究,以计算机随机数字表将其随机分成实验组和对照组,每组40例... 目的研究术前自体血存储联合白细胞过滤器血液回输在体外循环心脏手术中的应用效果。方法将2021年5月~2022年9月于我院拟行全身麻醉体外循环下心脏直视手术的80例患者纳入研究,以计算机随机数字表将其随机分成实验组和对照组,每组40例。实验组采用术前自体血存储联合白细胞过滤器血液回输,对照组则开展术前自体血存储联合自体血直接回输。对比两组各项炎症指标、心肌标志物以及心脏彩超指标在自体血回输前后的变化情况,以及住院时间、异体用血量。结果实验组回输后体内C反应蛋白(CRP)、肿瘤坏死因子-α(TNF-α)以及白细胞介素-6(IL-6)水平分别为(13.39±0.56)mg/L、(29.21±9.20)pg/ml、(35.95±3.22)pg/ml,均低于对照组的(17.45±0.84)mg/L、(33.57±8.50)pg/ml、(40.09±4.20)pg/ml;而白细胞介素IL-10(IL-10)水平为(40.38±4.21)pg/ml,高于对照组的(30.51±6.21)pg/ml(P<0.05)。实验组术后1 d、术后5 d的血清肌酸激酶同工酶(CK-MB)、肌钙蛋白T(cTnT)、N-末端脑利钠肽前体(NT-proBNP)水平均低于对照组(P<0.05)。实验组术后左室射血分数(LVEF)、左室短轴缩短率(FS)均高于对照组(P<0.05)。实验组住院时间为(13.59±2.30)d,短于对照组的(15.77±4.10)d;而异体用血量为(241.28±24.34)ml,少于对照组的(632.89±69.29)ml(P<0.05)。结论术前自体血存储联合白细胞过滤器血液回输对体外循环心脏手术的作用效果显著,可减轻患者全身炎症反应,提高心脏保护作用,促进患者早日康复。 展开更多
关键词 体外循环心脏手术 术前自体血存储 白细胞过滤器 血液回输
下载PDF
血液净化治疗滤网的功能特性指标研究
15
作者 胡相华 谢妍 宁锐剑 《医疗装备》 2023年第23期31-33,36,共4页
血液净化治疗滤网是血液净化治疗耗材中的重要功能组件,但现行标准尚缺少该部件相关统一适用的功能特性指标。针对这一情况,该研究结合血液净化治疗滤网的结构特点及适用的临床功能特性,对与临床功能相关的特性指标开展研究,从宏观及微... 血液净化治疗滤网是血液净化治疗耗材中的重要功能组件,但现行标准尚缺少该部件相关统一适用的功能特性指标。针对这一情况,该研究结合血液净化治疗滤网的结构特点及适用的临床功能特性,对与临床功能相关的特性指标开展研究,从宏观及微观方面分别对该组件的匹配性进行分析。实验结果显示,血液净化治疗滤网的适宜安装位置、网孔均匀性、合适孔高范围等结构特性有助于临床预期功能的实现。建议将滤网安装位置及相关网孔结构特性等指标作为完善相关产品行业标准参数的补充参考。 展开更多
关键词 血液净化治疗滤网 功能特性 指标研究
下载PDF
新生儿滤纸干血片自动打孔检测系统检测葡萄糖-6-磷酸脱氢酶的性能评价 被引量:1
16
作者 谭玉华 潘晓芳 +5 位作者 李高成 余海枷 陈梅欣 谭港澳 梁天铖 冯健明 《医疗装备》 2023年第2期16-20,共5页
目的评价新生儿滤纸干血片自动打孔检测系统检测葡萄糖-6-磷酸脱氢酶(G6PD)的性能,并探讨在新生儿G6PD缺乏症筛查中的应用可行性。方法选取2020年12月至2021年7月来源于临床科研合作单位的104份新生儿滤纸干血片剩余样本,采用新生儿滤... 目的评价新生儿滤纸干血片自动打孔检测系统检测葡萄糖-6-磷酸脱氢酶(G6PD)的性能,并探讨在新生儿G6PD缺乏症筛查中的应用可行性。方法选取2020年12月至2021年7月来源于临床科研合作单位的104份新生儿滤纸干血片剩余样本,采用新生儿滤纸干血片自动打孔检测系统(简称自动打孔法)进行新生儿滤纸干血片G6PD检测,并对其检测低限、线性、准确度、精密度和一致性等性能指标进行评价,并与直接打孔法试验结果进行对比。结果自动打孔法检测G6PD的检测低限为0.29 U/gHb;在0.96~10.20 U/gHb范围内的样本,实测浓度与理论浓度的线性相关系数达0.9996,检测浓度与理论浓度的相对偏倚均在1/3允许总误差(±10%)内;检测质控品C1和C2的批内变异系数(CV)均在1/4允许总误差(小于7.5%)内,批间CV均在1/3允许总误差(小于10%)内;与直接打孔法平行检测临床样本的结果间差异无统计学意义(P>0.05),两种方法检测结果间具有高度相关性(r=0.9991,P<0.05),阳性判断值(2.50 U/gHb)预期偏倚的95%置信区间在可以接受范围内,采用Bland-Altman分析,两种方法有97.12%(101/104)的样本结果偏差在一致界限范围内。结论自动打孔法检测G6PD的检测低限、线性、准确度和精密度等性能指标均符合可接受标准,且自动打孔法与直接打孔法检测结果一致性良好,可用于新生儿滤纸干血片样本G6PD检测。 展开更多
关键词 新生儿 滤纸干血片 自动打孔法 葡萄糖-6-磷酸脱氢酶 性能评价
下载PDF
双机换管法在老年重症患者连续性血液净化中的应用
17
作者 胡培航 梁慧梅 +4 位作者 谢银均 王首红 郭晓婵 全梓林 廖游玩 《护理学杂志》 CSCD 北大核心 2023年第20期35-38,共4页
目的 提高老年重症患者行连续性血液净化治疗更换管路和滤器的效率和安全性。方法 将41例行连续性血液净化治疗的老年重症患者随机分为对照组20例、观察组21例。对照组按常规置换滤器与管路69例次,观察组采取双机法更换滤器与管路65例... 目的 提高老年重症患者行连续性血液净化治疗更换管路和滤器的效率和安全性。方法 将41例行连续性血液净化治疗的老年重症患者随机分为对照组20例、观察组21例。对照组按常规置换滤器与管路69例次,观察组采取双机法更换滤器与管路65例次。结果 观察组更换滤器与管路时间显著少于对照组,更换过程中血压波动值显著小于对照组(均P<0.05);心率波动值两组比较,差异无统计学意义(P>0.05)。结论 对行连续性血液净化治疗的老年重症患者采用双机法更换滤器和管路,可显著提高更换效率,患者血流动力学更稳定。 展开更多
关键词 老年人 重症 连续性血液净化 滤器 管路 双机换管法 血流动力学
下载PDF
两种不同过滤方法对去白细胞混合浓缩血小板的影响分析
18
作者 陈玉燕 陈惠民 连晓征 《中国卫生标准管理》 2023年第1期172-175,共4页
目的探讨白膜法分离血小板混合过滤法和血小板混合过滤法去除混合浓缩血小板中白细胞(white blood cell,WBC)对混合浓缩血小板残余WBC和血小板含量是否有影响。方法选择2021年6—12月泉州市中心血站符合文献要求的献血者所献全血400 mL... 目的探讨白膜法分离血小板混合过滤法和血小板混合过滤法去除混合浓缩血小板中白细胞(white blood cell,WBC)对混合浓缩血小板残余WBC和血小板含量是否有影响。方法选择2021年6—12月泉州市中心血站符合文献要求的献血者所献全血400 mL,将血袋按1、2、3等顺序编号,编号是奇数血液生产的浓缩血小板用白膜法分离血小板混合过滤法去除WBC,编号是偶数血液生产的浓缩血小板用血小板混合过滤法去除WBC,计算这两种方法的WBC残余数和血小板计数(platelet count,PLT)的含量,同时计算残余WBC和PLT合格率,并进行比较分析。结果40袋白膜法分离血小板混合过滤法和40袋血小板混合过滤法去除WBC,其残余WBC平均值分别为(4.01±1.33)×10^(5)/袋和(1.63±0.91)×10^(5)/袋,前者WBC残余值是后者的2倍多,且差异有统计学意义(t=9.34,P<0.05)。两种过滤去WBC方法的PLT含量平均值分别为(3.47±1.49)×10^(11)/袋和(2.94±1.03)×10^(11)/袋,白膜法分离血小板混合过滤法PLT含量较高,但差异无统计学意义(t=1.85,P>0.05)。两种过滤方法去白细胞后WBC残余合格率分别为80.0%和97.5%,血小板混合过滤法WBC残余合格率97.5%,合格率明显较高,差异有统计学意义(P<0.05),两种去白细胞方法的PLT含量合格率分别为85.0%和75.0%,但差异无统计学意义(P>0.05)。结论血小板混合过滤法去除WBC比较好地平衡去除白细胞和保留血小板,因此建议采用血小板混合过滤法去除混合浓缩血小板WBC。 展开更多
关键词 血站 白膜法 浓缩血小板 白细胞 过滤 混合过滤
下载PDF
下肢深静脉血栓患者下腔静脉滤器置入术后发生静脉不畅的影响因素 被引量:3
19
作者 刘振华 赵振蓓 《中国民康医学》 2023年第6期13-15,共3页
目的:探讨下肢深静脉血栓(DVT)患者下腔静脉滤器(IVCF)置入术后发生静脉不畅的影响因素。方法:回顾性分析2020年3月至2022年4月该院收治的70例下肢DVT患者的临床资料,患者均行IVCF置入术治疗,术后3个月复查,根据静脉通畅程度将其分为静... 目的:探讨下肢深静脉血栓(DVT)患者下腔静脉滤器(IVCF)置入术后发生静脉不畅的影响因素。方法:回顾性分析2020年3月至2022年4月该院收治的70例下肢DVT患者的临床资料,患者均行IVCF置入术治疗,术后3个月复查,根据静脉通畅程度将其分为静脉通畅组32例和静脉不畅组38例。收集患者的临床资料,采用单因素和多因素Logistic回归分析下肢DVT患者IVCF置入术后发生静脉不畅的影响因素。结果:两组性别、年龄、体质量指数、DVT分期、D-二聚体水平比较,差异均无统计学意义(P>0.05);静脉不畅组合并糖尿病、高血压占比和白细胞计数(WBC)、血小板计数(PLT)、纤维蛋白原(FIB)水平均高于静脉通畅组,差异有统计学意义(P<0.05);Logistic回归分析结果显示,合并糖尿病、高血压和WBC、PLT、FIB水平升高均为下肢DVT患者IVCF置入术后发生静脉不畅的危险因素(P<0.05)。结论:合并糖尿病、高血压和WBC、PLT、FIB水平升高均为下肢DVT患者IVCF置入术后发生静脉不畅的危险因素,临床可针对上述危险因素实施针对性干预措施,以改善预后。 展开更多
关键词 下肢 深静脉血栓 下腔静脉滤器置入术 静脉不畅 影响因素 糖尿病 高血压 白细胞计数
下载PDF
滤纸片干血斑在HIV-1 BED-CEIA新发感染检测方法中的应用
20
作者 王娇 《口岸卫生控制》 2023年第3期42-46,共5页
目的探讨在HIV-1 BED-CEIA新发感染检测中应用滤纸片干血斑的价值。方法研究纳入22个艾滋病自愿咨询检测(VCT)中心10226名咨询者血浆及干血斑样本作为目标实施HIV抗体检测,对通过免疫印迹法(WB)明确诊断为350例HIV感染患者的血浆样本及... 目的探讨在HIV-1 BED-CEIA新发感染检测中应用滤纸片干血斑的价值。方法研究纳入22个艾滋病自愿咨询检测(VCT)中心10226名咨询者血浆及干血斑样本作为目标实施HIV抗体检测,对通过免疫印迹法(WB)明确诊断为350例HIV感染患者的血浆样本及干血斑样本需同时实施BED-CEIA检测,观察滤纸片干血斑在HIV-1 BED-CEIA新发感染检测方法中稳定性、重复性,对两种样本检测结果存在的差异性进行对比。结果在HIV-1 BED-CEIA新发感染检测中应用滤纸片干血斑稳定性、重复性较高,重复性R^(2)值可高达0.9551。350例HIV感染患者样本检测结果中,其中295例患者样本被同时评估为长期感染,53例患者样本被同时评估为新近感染,两种样本对HIV BED-CEIA新发感染评估判定结果呈一致性(R^(2)值=0.95),一致性为99.42%。血浆样本及干血斑样本得到不同结果,样本An值均处于临界值附近(P<0.05)。结论在HIV-1 BED-CEIA新发感染检测中应用滤纸片干血斑的价值较高,检测结果稳定性、重复性较好,虽然部分样本检测结果存在一定的差异,但与血浆样本检测结果两者之间存在较佳的等效性,可广泛应用于临床HIV-1 BED-CEIA新近感染检测中。 展开更多
关键词 人类免疫缺陷病毒 滤纸片干血斑 新发感染 BED捕获酶联免疫法
下载PDF
上一页 1 2 12 下一页 到第
使用帮助 返回顶部