期刊文献+
共找到12篇文章
< 1 >
每页显示 20 50 100
Clinical and Therapeutic Evaluation of Hypertensives According to the Practice of Ambulatory Blood Pressure Measurement (ABPM) at the Bel Air International Clinic in Conakry from January 1, 2019 to November 30, 2022
1
作者 Alpha Kone Fousseny Diakite +11 位作者 Abel Mansaré Mahamoud Sama Cherif Mamadou Bassirou Bah Sana Samoura Souleymane Diakité Ibrahima Sory Barry Ibrahima Sory Sylla Elhadji Yaya Baldé Abdoulaye Bangoura Mariame Beavogui Mamadou Dadhi Baldé Mohamed Lamine Kaba 《World Journal of Cardiovascular Diseases》 2023年第6期327-332,共6页
Introduction: Ambulatory Blood Pressure Measurement (ABPM) is a non- invasive examination recommended for subjects at high cardiovascular risk, and those requiring a nocturnal drop in BP such as elderly and obese... Introduction: Ambulatory Blood Pressure Measurement (ABPM) is a non- invasive examination recommended for subjects at high cardiovascular risk, and those requiring a nocturnal drop in BP such as elderly and obese subjects, those with secondary hypertension or resistant, diabetics, subjects with metabolic syndrome or sleep apnea syndrome. The objective of this study was to evaluate the contribution of ABPM in the diagnosis and evaluation of the level of control of hypertension under treatment at the Bel Air international clinic. Materials and Methods: This is a retrospective, cross-sectional and descriptive study, carried out at the Bel Air International Clinic in Conakry (Guinea) between January 2019 and November 30, 2022. It included a consecutive series of 180 consenting patients recruited through an ambulatory measurement of 24-hour blood pressure from a FUGADA brand device. Results: We collected 180 patients, with a male predominance (sex-ratio M/F = 2.46). The mean age of the patients was 48.48 ± 14.23 years. The most represented age group was that of 32 to 42 years with 50 cases (27.8%) followed by that of 43 to 52 years with 42 cases or 23.3%. The indication was for diagnostic purposes in 106 cases 58.9%, the therapeutic evaluation in 58 patients (32.2%). The examination was prescribed by a cardiologist in 98 cases (54.4%), a general practitioner in 71 cases (39.4%), a neurologist in 11 cases (6.1%). In the therapeutic evaluation, high blood pressure was controlled in 24 patients (13.3%) and uncontrolled in 34 cases (18.9%). In the diagnostic indication, high blood pressure was confirmed in 79 cases (43.9%) with a statistically significant link (Chi2</sup> = 4.57 and p-value = 0.032). The nycthemeral mean was 187.27 ± 26.22 mmHg for systolic blood pressure (SBP) and 110.37 ± 19.06 mmHg for diastolic blood pressure (DBP), during the day, 151.64 ± 21.45 mmHg for SBP and 71.59 ± 8.67 mmHg for diastolic blood pressure. During the study 65 patients (36.1%) were identified as dippers and 115 patients (63.9%) were no-dipping. The antihypertensive protocol used was monotherapy in 68 cases (37.8%), dual therapy in 46 cases (25.6%), triple therapy in 17 cases (9.4%). However 39 patients or 21.7% were not taking any antihypertensive. Conclusion: This preliminary study, despite the modest sample size, showed the importance of ABPM as a tool for diagnosis, monitoring of hypertensive patients and therapeutic adaptation. A large-scale national study would be necessary for the rational use of ambulatory blood pressure measurement in our context in order to improve the management of hypertensive patients. 展开更多
关键词 Ambulatory blood Pressure measurement GUINEA
下载PDF
Numerical analysis of stress distribution in the upper arm tissues under an inflatable cuff:Implications for noninvasive blood pressure measurement 被引量:3
2
作者 Zhipeng Deng Fuyou Liang 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2016年第5期959-969,共11页
An inflatable cuff wrapped around the upper arm is widely used in noninvasive blood pressure measurement.However, the mechanical interaction between cuff and arm tissues, a factor that potentially affects the accuracy... An inflatable cuff wrapped around the upper arm is widely used in noninvasive blood pressure measurement.However, the mechanical interaction between cuff and arm tissues, a factor that potentially affects the accuracy of noninvasive blood pressure measurement, remains rarely addressed. In the present study, finite element(FE) models were constructed to quantify intra-arm stresses generated by cuff compression, aiming to provide some theoretical evidence for identifying factors of importance for blood pressure measurement or explaining clinical observations. Obtained results showed that the simulated tissue stresses were highly sensitive to the distribution of cuff pressure on the arm surface and the contact condition between muscle and bone. In contrast, the magnitude of cuff pressure and small variations in elastic properties of arm soft tissues had little influence on the efficiency of pressure transmission in arm tissues. In particular, it was found that a thickened subcutaneous fat layer in obese subjects significantly reduced the effective pressure transmitted to the brachial artery, which may explain why blood pressure overestimation occurs more frequently in obese subjects in noninvasive blood pressure measurement. 展开更多
关键词 Noninvasive blood pressure measurement Inflatable cuff Upper arm Finite element(FE) model Loading and contact conditions Stress distribution Obese patients
下载PDF
A Deep Learning-Based Continuous Blood Pressure Measurement by Dual Photoplethysmography Signals 被引量:1
3
作者 Chih-Ta Yen Sheng-Nan Chang +1 位作者 Liao Jia-Xian Yi-Kai Huang 《Computers, Materials & Continua》 SCIE EI 2022年第2期2937-2952,共16页
This study proposed a measurement platform for continuous blood pressure estimation based on dual photoplethysmography(PPG)sensors and a deep learning(DL)that can be used for continuous and rapid measurement of blood ... This study proposed a measurement platform for continuous blood pressure estimation based on dual photoplethysmography(PPG)sensors and a deep learning(DL)that can be used for continuous and rapid measurement of blood pressure and analysis of cardiovascular-related indicators.The proposed platform measured the signal changes in PPG and converted them into physiological indicators,such as pulse transit time(PTT),pulse wave velocity(PWV),perfusion index(PI)and heart rate(HR);these indicators were then fed into the DL to calculate blood pressure.The hardware of the experiment comprised 2 PPG components(i.e.,Raspberry Pi 3 Model B and analog-todigital converter[MCP3008]),which were connected using a serial peripheral interface.The DL algorithm converted the stable dual PPG signals acquired from the strictly standardized experimental process into various physiological indicators as input parameters and finally obtained the systolic blood pressure(SBP),diastolic blood pressure(DBP)and mean arterial pressure(MAP).To increase the robustness of the DL model,this study input data of 100 Asian participants into the training database,including those with and without cardiovascular disease,each with a proportion of approximately 50%.The experimental results revealed that the mean absolute error and standard deviation of SBP was 0.17±0.46 mmHg.The mean absolute error and standard deviation of DBP was 0.27±0.52 mmHg.The mean absolute error and standard deviation of MAP was 0.16±0.40 mmHg. 展开更多
关键词 Deep learning(DL) blood pressure continuous non-invasive blood pressure measurement photoplethysmography(PGG)
下载PDF
Non-Contact Blood Pressure Measurement Based on IPPG
4
作者 Jiancheng Zou Shouyu Zhou +1 位作者 Bailin Ge Xin Yang 《Journal of New Media》 2021年第2期41-51,共11页
Blood pressure is an important physiological parameter to reflect human vital signs.In order to achieve the non-contact dynamic blood pressure acquisition based on ordinary optical camera,a theoretical understanding o... Blood pressure is an important physiological parameter to reflect human vital signs.In order to achieve the non-contact dynamic blood pressure acquisition based on ordinary optical camera,a theoretical understanding of the functional relationship between blood pressure and pulse wave signal conduction time.And through imaging photoelectric plethysmography(IPPG),pulse wave signal conduction time of forehead and hand was obtained with ordinary optical camera.First,the pulse wave conduction time was obtained by recording the video with an ordinary optical camera.Second,real-time blood pressure values were collected.Finally,based on the relationship between blood pressure and pulse wave conduction time,a non-contact blood pressure measurement prediction model was obtained through neural network fitting.So that non-contact blood pressure measurement with optical camera could be completed.The method in this paper has several advantages,such as low requirements on measuring equipment,low cost,and simple operation.It can let people get rid of the discomfort caused by measuring equipment such as cuff and can measure blood pressure at any time.The predicted blood pressure results were compared with an Omron wrist electronic sphygmomanometer.The calculated error of systolic blood pressure is-9.28%~3.16%,and the error of diastolic blood pressure is-9.84~4.35%. 展开更多
关键词 Non contact blood pressure measurement imaging photoelectric plethysmography(IPPG) pulse wave conduction time
下载PDF
Analysis and counter measure in blood grouping errors of volunteers’donating blood
5
《中国输血杂志》 CAS CSCD 2001年第S1期378-,共1页
关键词 Analysis and counter measure in blood grouping errors of volunteers
下载PDF
Investigation on the relationship between overpressure and sub-harmonic response from encapsulated microbubbles 被引量:2
6
作者 吴军 范庭波 +1 位作者 许迪 章东 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第10期268-274,共7页
Sub-harmonic component generated from microbubbles is proven to be potentially used in noninvasive blood pressure measurement. Both theoretical and experimental studies are performed in the present work to investigate... Sub-harmonic component generated from microbubbles is proven to be potentially used in noninvasive blood pressure measurement. Both theoretical and experimental studies are performed in the present work to investigate the dependence of the sub-harmonic generation on the overpressure with different excitation pressure amplitudes and pulse lengths. With 4-MHz ultrasound excitation at an applied acoustic pressure amplitude of 0.24 MPa, the measured sub-harmonic amplitude exhibits a decreasing change as overpressure increases; while non-monotonic change is observed for the applied acoustic pressures of 0.36 MPa and 0.48 MPa, and the peak position in the curve of the sub-harmonic response versus the overpres- sure shifts toward higher overpressure as the excitation pressure amplitude increases. Furthermore, the exciting pulse with long duration could lead to a better sensitivity of the sub-harmonic response to overpressure. The measured results are ex- plained by the numerical simulations based on the Marmottant model. The numerical simulations qualitatively accord with the measured results. This work might provide a preliminary proof for the optimization of the noninvasive blood pressure measurement through using sub-harmonic generation from microbubbles. 展开更多
关键词 MICROBUBBLE OVERPRESSURE sub-harmonic response blood pressure measurement
下载PDF
Application of transcutaneous diffuse reflectance spectroscopy in the measurement of blood glucose concentration 被引量:5
7
作者 陈文亮 刘蓉 +2 位作者 崔厚欣 徐可欣 吕丽娜 《Chinese Optics Letters》 SCIE EI CAS CSCD 2004年第7期411-413,共3页
In this paper, the propagation characteristics of near-infrared (NIR) light in the palm tissue are analyzed, and the principle and feasibility of using transcutaneous diffuse reflectance spectroscopy for non-invasive ... In this paper, the propagation characteristics of near-infrared (NIR) light in the palm tissue are analyzed, and the principle and feasibility of using transcutaneous diffuse reflectance spectroscopy for non-invasive blood glucose detection are presented. An optical probe suitable for measuring the diffuse reflectance spectrum of human palm and a non-invasive blood glucose detection system using NIR spectroscopy are designed. Based on this system, oral glucose tolerance tests are performed to measure the blood glucose concentrations of two young healthy volunteers. The partial least square calibration model is then constructed by all individual experimental data. The final result shows that correlation coefficients of the two experiments between the predicted blood glucose concentrations and the reference blood glucose concentrations are 0.9870 and 0.9854, respectively. The root mean square errors of prediction of full cross validation are 0.54 and 0.52 mmol/1, respectively. 展开更多
关键词 Application of transcutaneous diffuse reflectance spectroscopy in the measurement of blood glucose concentration NIR OGTT
原文传递
Diabetes and COVID-19:Role of insulin resistance as a risk factor for COVID-19 severity 被引量:1
8
作者 Charitha Gangadharan Rupa Ahluwalia Alben Sigamani 《World Journal of Diabetes》 SCIE 2021年第9期1550-1562,共13页
Patients with diabetes are more susceptible to coronavirus disease 2019(COVID-19),and as a consequence,develop more severe form of disease.This is partly due to a systemic inflammatory state and pro thrombotic milieu ... Patients with diabetes are more susceptible to coronavirus disease 2019(COVID-19),and as a consequence,develop more severe form of disease.This is partly due to a systemic inflammatory state and pro thrombotic milieu seen in metabolic syndrome.In this review,we attempt to explore the pathogenetic links between insulin resistance and COVID-19 disease severity.Insulin resistance is an underlying condition for metabolic syndromes,including type 2 diabetes,which impairs insulin signaling pathways affecting metabolic and cardiovascular homeostasis.A high concentration of circulating insulin shifts the balance to mitogen activated protein kinase(MAPK)-dependent signaling and causes endothelial cell damage.The phosphatidylinositol 3 kinase and MAPK dependent signaling pathways maintain a balance between nitric oxide-dependent vasodilator and endothelin-1 dependent vasoconstriction actions of insulin.Vascular smooth muscle cell dysfunction is responsible for inflammation and blood coagulation leading to microvascular and macrovascular complications in diabetes.Hyperactivity in renin-angiotensin system is implicated in development of islet oxidative stress and subsequentβ-cell dysfunction,as it alters the islet blood flow.These deleterious effects of insulin resistance involving altered blood pressure,vascular dysfunction,and inflammation could be associated with increased severity in COVID-19 patients.We conclude that clinical and/or biochemical markers of insulin resistance should be included as prognostic markers in assessment of acute COVID-19 disease. 展开更多
关键词 Insulin resistance Renin-angiotensin system blood flow measurements INFLAMMATION THROMBOSIS Severity of COVID-19
下载PDF
Real-time human blood pressure measurement based on laser self-mixing interferometry with extreme learning machine 被引量:2
9
作者 王秀琳 吕莉萍 +1 位作者 胡路 黄文财 《Optoelectronics Letters》 EI 2020年第6期467-470,共4页
In this paper, we present a method based on self-mixing interferometry combing extreme learning machine for real-time human blood pressure measurement. A signal processing method based on wavelet transform is applied ... In this paper, we present a method based on self-mixing interferometry combing extreme learning machine for real-time human blood pressure measurement. A signal processing method based on wavelet transform is applied to extract reversion point in the self-mixing interference signal, thus the pulse wave profile is successfully reconstructed. Considering the blood pressure values are intrinsically related to characteristic parameters of the pulse wave, 80 samples from the MIMIC-II database are used to train the extreme learning machine blood pressure model. In the experiment, 15 measured samples of pulse wave signal are used as the prediction sets. The results show that the errors of systolic and diastolic blood pressure are both within 5 mm Hg compared with that by the Coriolis method. 展开更多
关键词 PROFILE Real-time human blood pressure measurement based on laser self-mixing interferometry with extreme learning machine
原文传递
An assessment on the wideband and narrowband methods for ultrasonic blood flow measurements
10
作者 QI Jinyi GAO Shangkai and YANG Fusheng(Dept. of electrical engineering, Tsinghua university Beijing 100084) 《Chinese Journal of Acoustics》 1997年第1期59-70,共12页
A comparison study on the ultrasonic blood flow estimation methods is carried out in this paper. The methods are divided into two classes-narrowband and wideband techniques.The pulsed Doppler systems and the autocorre... A comparison study on the ultrasonic blood flow estimation methods is carried out in this paper. The methods are divided into two classes-narrowband and wideband techniques.The pulsed Doppler systems and the autocorrelation methods are essentially the narrowband estAnators. They give the results with low velocity resolution and probably the aliased spectrum.The wider the frequency band of the signals, the worse the results. Time domain crosscorrelation technique, wideband makimum likelihood estimation and 2D Fourier transform method are three wideband techniques. The high velocity resolution and the ability of anti-aliasing are shown by these wideband estimation strategies. 展开更多
关键词 flow An assessment on the wideband and narrowband methods for ultrasonic blood flow measurements IEEE
原文传递
Simultaneous blood flow and oxygenation measurements using an off-the-shelf spectrometer
11
作者 成明洙 Phuong Minh Mai +1 位作者 李基準 金載官 《Chinese Optics Letters》 SCIE EI CAS CSCD 2018年第7期60-64,共5页
Blood oxygenation and flow are both important parameters in a living body. In this Letter, we introduce a simple configuration to simultaneously measure blood flow and oxygenation using an off-the-shelf spectrometer. ... Blood oxygenation and flow are both important parameters in a living body. In this Letter, we introduce a simple configuration to simultaneously measure blood flow and oxygenation using an off-the-shelf spectrometer. With the integration time of 10 ms, flow phantom measurements, a liquid blood phantom test, and an arm cuff occlusion paradigm were performed to validate the feasibility of the system. We expect this proof-of-concept study would be widely adopted by other researchers for acquiring both blood flow and oxygenation changes due to its straightforward configuration and the possibility of multimodal measurement. 展开更多
关键词 Simultaneous blood flow and oxygenation measurements using an off-the-shelf spectrometer BFI
原文传递
Doctor Reports New Way to Measure Blood Sugar
12
作者 林徽英 《当代外语研究》 2000年第4期2-3,共2页
对“糖尿病”及其危害,本文有一简略说明: Diabetes occurs when blood sugar,or glucose,a source of body fuel,is toohigh and the body is not able to burn it.The disease can lead to blindness,organdiseases,stroke and death.... 对“糖尿病”及其危害,本文有一简略说明: Diabetes occurs when blood sugar,or glucose,a source of body fuel,is toohigh and the body is not able to burn it.The disease can lead to blindness,organdiseases,stroke and death. 句中的一个动词burn令我们过目难忘。此外,此疾引起的后果也令人生畏:blindness,organ diseases,stroke and death. 要测得患者的血糖含量,就得验血,就得像本文所讲的那样“pricking(刺;戳)the skin and drawing a tiny amount of blood”。 美国宾夕法尼亚州立大学的研究人员研制了a hand—held ultrasound(超声波)machine,验血者可免受皮肉之苦,而又可测量到准确的血糖含量。 文章末尾有一条信息:美国人中糖尿病患者约占总人口的6%。 展开更多
关键词 糖尿病患者 REPORTS Doctor Reports New Way to Measure blood Sugar 血糖含量 超声波
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部