To enable the experimental assessment of the seismic performance of full-scale nonstructural elements with multiple engineering parameters(EDPs),a three-layer testbed named Nonstructural Element Simulator on Shake Tab...To enable the experimental assessment of the seismic performance of full-scale nonstructural elements with multiple engineering parameters(EDPs),a three-layer testbed named Nonstructural Element Simulator on Shake Table(NEST)has been developed.The testbed consists of three consecutive floors of steel structure.The bottom two floors provide a space to accommodate a full-scale room.To fully explore the flexibility of NEST,we propose a novel control strategy to generate the required shake table input time histories for the testbed to track the target floor motions of the buildings of interest with high accuracy.The control strategy contains two parts:an inverse dynamic compensation via simulation of feedback control systems(IDCS)algorithm and an offline iteration procedure based on a refined nonlinear numerical model of the testbed.The key aspects of the control strategy were introduced in this paper.Experimental tests were conducted to simulate the seismic responses of a full-scale office room on the 21^(st)floor of a 42-story high-rise building.The test results show that the proposed control strategy can reproduce the target floor motions of the building of interest with less than 20%errors within the specified frequency range.展开更多
A retrofitting technology using precast steel reinforced concrete(PSRC) panels is developed to improve the seismic performance of old masonry buildings. The PSRC panels are built up as an external PSRC wall system s...A retrofitting technology using precast steel reinforced concrete(PSRC) panels is developed to improve the seismic performance of old masonry buildings. The PSRC panels are built up as an external PSRC wall system surrounding the existing masonry building. The PSRC walls are well connected to the existing masonry building, which provides enough confinement to effectively improve the ductility, strength, and stiffenss of old masonry structures. The PSRC panels are prefabricated in a factory, significantly reducing the situ work and associated construction time. To demonstrate the feasibility and mechanical effectivenss of the proposed retrofitting system, a full-scale five-story specimen was constructed. The retrofitting process was completed within five weeks with very limited indoor operation. The specimen was then tested in the lateral direction, which could potentially suffer sigifnicant damage in a large earthquake. The technical feasibility, construction workability, and seismic performance were thoroughly demonstrated by a full-scale specimen construction and pseudo-dynamic tests.展开更多
This paper presents the results from shaking table tests of a one-tenth-scale reinforced concrete (RC) building model.The test model is a protype of a building that was seriously damaged during the 1985 Mexico earthqu...This paper presents the results from shaking table tests of a one-tenth-scale reinforced concrete (RC) building model.The test model is a protype of a building that was seriously damaged during the 1985 Mexico earthquake.The input ground excitation used during the test was from the records obtained near the site of the prototype building during the 1985 and 1995 Mexico earthquakes.The tests showed that the damage pattern of the test model agreed well with that of the prototype building.Analytical prediction of earthquake response has been conducted for the prototype building using a sophisticated 3-D frame model.The input motion used for the dynamic analysis was the shaking table test measurements with similarity transformation.The comparison of the analytical results and the shaking table test results indicates that the response of the RC building to minor and the moderate earthquakes can be predicated well.However,there is difference between the predication and the actual response to the major earthquake.展开更多
Since the research on verification to passive design strategies in sustainable building is at the initial stage,and its test method and verification conclusion are not scientific enough to validate,this paper proposes...Since the research on verification to passive design strategies in sustainable building is at the initial stage,and its test method and verification conclusion are not scientific enough to validate,this paper proposes the necessity of building physical environmental monitoring to quantitative optimization of passive strategies efficiency from the perspective of architecture design and building environment. Adopting comparative research method,this research chooses six types of atrium space in cold climate in China as a prototype,focusing on building physical environmental performance difference in and between atrium and building main space. Spatial parameters of the atrium space will be divided into four factors: spatial geometry,interfacial properties,internal and external related categories. With subdividing these four factors into sub-factors,this paper makes crosscomparison among the sub-factors to clarify passive strategies effectiveness in atrium. Data comparison analysis shows that Winter atrium passive strategy in cold regions from traditional view is not obvious in practical application,and test data need to be stratified refined in atrium design in case of optimizing passive strategy from building prototype perspective.展开更多
We carried out a wind tunnel test to measure cladding loads for a high-rise building of 295 m in height, which would be located in the business center of Chongqing Municipality, P. R. China. The rigid model was used t...We carried out a wind tunnel test to measure cladding loads for a high-rise building of 295 m in height, which would be located in the business center of Chongqing Municipality, P. R. China. The rigid model was used to determine fluctuating local pressures on the exterior surfaces of the building. The wind tunnel test results show the cr/tical zone of wind pressures on building surfaces in both standalone and interference conditions. The computational fluid dynamics (CFD) was conducted by using the FLUENT Code to compare with the wind tunnel test results, and the steady three-dimensional turbulent flow with Realizable k-ε as a turbulence model was used. The CFD results are agree with the wind tunnel test results in regards to distributions of wind pressures over a high-rise building's surfaces.展开更多
装备测试性工程技术起源于20世纪80年代,是先进测试技术与系统工程紧密结合的产物。该技术经过40余年的发展逐渐成熟,在测试性需求分析与分配、测试性建模与方案优化设计、机内测试(Built⁃In Test,BIT)与自动测试系统(Automatic Test Sy...装备测试性工程技术起源于20世纪80年代,是先进测试技术与系统工程紧密结合的产物。该技术经过40余年的发展逐渐成熟,在测试性需求分析与分配、测试性建模与方案优化设计、机内测试(Built⁃In Test,BIT)与自动测试系统(Automatic Test System,ATS)设计、测试性试验与评估等方面形成了较完善的理论体系,并在各型装备中得到了普遍应用,取得了较大的军事和社会效益。今后测试性基础研究和应用探索究竟该如何开展,未来发展方向是怎样的,是亟需深入探讨的问题。在对测试性工程技术的产生背景与需求、概念与内涵、发展历程、关键技术现状与新进展进行剖析的基础上,指出了目前测试性工程技术研究存在的问题和今后研究突破的方向。展开更多
基金supported by the Natural Science Foundation of China(52122811)。
文摘To enable the experimental assessment of the seismic performance of full-scale nonstructural elements with multiple engineering parameters(EDPs),a three-layer testbed named Nonstructural Element Simulator on Shake Table(NEST)has been developed.The testbed consists of three consecutive floors of steel structure.The bottom two floors provide a space to accommodate a full-scale room.To fully explore the flexibility of NEST,we propose a novel control strategy to generate the required shake table input time histories for the testbed to track the target floor motions of the buildings of interest with high accuracy.The control strategy contains two parts:an inverse dynamic compensation via simulation of feedback control systems(IDCS)algorithm and an offline iteration procedure based on a refined nonlinear numerical model of the testbed.The key aspects of the control strategy were introduced in this paper.Experimental tests were conducted to simulate the seismic responses of a full-scale office room on the 21^(st)floor of a 42-story high-rise building.The test results show that the proposed control strategy can reproduce the target floor motions of the building of interest with less than 20%errors within the specified frequency range.
基金Scientific Research Fund of Institute of Engineering Mechanics,CEA under Grant No.2016A06International Science & Technology Cooperation Program of China under Grant No.2014DFA70950National Natural Science Foundation of China under Grant Nos.51378478,51161120360
文摘A retrofitting technology using precast steel reinforced concrete(PSRC) panels is developed to improve the seismic performance of old masonry buildings. The PSRC panels are built up as an external PSRC wall system surrounding the existing masonry building. The PSRC walls are well connected to the existing masonry building, which provides enough confinement to effectively improve the ductility, strength, and stiffenss of old masonry structures. The PSRC panels are prefabricated in a factory, significantly reducing the situ work and associated construction time. To demonstrate the feasibility and mechanical effectivenss of the proposed retrofitting system, a full-scale five-story specimen was constructed. The retrofitting process was completed within five weeks with very limited indoor operation. The specimen was then tested in the lateral direction, which could potentially suffer sigifnicant damage in a large earthquake. The technical feasibility, construction workability, and seismic performance were thoroughly demonstrated by a full-scale specimen construction and pseudo-dynamic tests.
基金National Natural Science Foundation of China Under Grant No.59978013
文摘This paper presents the results from shaking table tests of a one-tenth-scale reinforced concrete (RC) building model.The test model is a protype of a building that was seriously damaged during the 1985 Mexico earthquake.The input ground excitation used during the test was from the records obtained near the site of the prototype building during the 1985 and 1995 Mexico earthquakes.The tests showed that the damage pattern of the test model agreed well with that of the prototype building.Analytical prediction of earthquake response has been conducted for the prototype building using a sophisticated 3-D frame model.The input motion used for the dynamic analysis was the shaking table test measurements with similarity transformation.The comparison of the analytical results and the shaking table test results indicates that the response of the RC building to minor and the moderate earthquakes can be predicated well.However,there is difference between the predication and the actual response to the major earthquake.
基金Sponsored by the Key Project of National Natural Science Foundation of China (Grant No.51138004)the National Science and Technology Support Program (Grant No.2012BAJ10B02)
文摘Since the research on verification to passive design strategies in sustainable building is at the initial stage,and its test method and verification conclusion are not scientific enough to validate,this paper proposes the necessity of building physical environmental monitoring to quantitative optimization of passive strategies efficiency from the perspective of architecture design and building environment. Adopting comparative research method,this research chooses six types of atrium space in cold climate in China as a prototype,focusing on building physical environmental performance difference in and between atrium and building main space. Spatial parameters of the atrium space will be divided into four factors: spatial geometry,interfacial properties,internal and external related categories. With subdividing these four factors into sub-factors,this paper makes crosscomparison among the sub-factors to clarify passive strategies effectiveness in atrium. Data comparison analysis shows that Winter atrium passive strategy in cold regions from traditional view is not obvious in practical application,and test data need to be stratified refined in atrium design in case of optimizing passive strategy from building prototype perspective.
基金Funded by the National Natural Science Foundation of China(No.90715024)
文摘We carried out a wind tunnel test to measure cladding loads for a high-rise building of 295 m in height, which would be located in the business center of Chongqing Municipality, P. R. China. The rigid model was used to determine fluctuating local pressures on the exterior surfaces of the building. The wind tunnel test results show the cr/tical zone of wind pressures on building surfaces in both standalone and interference conditions. The computational fluid dynamics (CFD) was conducted by using the FLUENT Code to compare with the wind tunnel test results, and the steady three-dimensional turbulent flow with Realizable k-ε as a turbulence model was used. The CFD results are agree with the wind tunnel test results in regards to distributions of wind pressures over a high-rise building's surfaces.
文摘装备测试性工程技术起源于20世纪80年代,是先进测试技术与系统工程紧密结合的产物。该技术经过40余年的发展逐渐成熟,在测试性需求分析与分配、测试性建模与方案优化设计、机内测试(Built⁃In Test,BIT)与自动测试系统(Automatic Test System,ATS)设计、测试性试验与评估等方面形成了较完善的理论体系,并在各型装备中得到了普遍应用,取得了较大的军事和社会效益。今后测试性基础研究和应用探索究竟该如何开展,未来发展方向是怎样的,是亟需深入探讨的问题。在对测试性工程技术的产生背景与需求、概念与内涵、发展历程、关键技术现状与新进展进行剖析的基础上,指出了目前测试性工程技术研究存在的问题和今后研究突破的方向。