A diffraction-limited storage ring with a multi-bend achromat lattice suffers from a small dynamic aperture for conventional off-axis injection.Thus,a longitudinal on-axis injection scheme based on a new type of crab ...A diffraction-limited storage ring with a multi-bend achromat lattice suffers from a small dynamic aperture for conventional off-axis injection.Thus,a longitudinal on-axis injection scheme based on a new type of crab cavity is proposed in this paper.Particle tracking simulations were performed to study the disturbance of the stored beam and the motion of the injected beam during the injection process.The possibility of multi-bunch injections was discussed.In addition,the effect of the long-range wake field induced by the stored beam was analyzed.A C-band standing-wave crab cavity was designed and produced as requested,and its field distribution was measured.The corresponding results are consistent with the simulation results.展开更多
The Hefei light source(HLS) has been upgraded into HLS II, with increased brightness and stability. In this paper, the new injection system is described. Elegant program is used to simulate the particles motion in 6D ...The Hefei light source(HLS) has been upgraded into HLS II, with increased brightness and stability. In this paper, the new injection system is described. Elegant program is used to simulate the particles motion in 6D phase space. In the process of tracking simulation of electrons, the system tolerances and magnet errors are introduced. Influences to the injection efficiency from beam injection deviation are studied. These provide important reference for realizing the Top-up injection.展开更多
Hefei synchrotron radiation Light Source (HLS) is a low energy Syn-chrotron Radiation (SR) facility. The SR produced from the HLS is in a series of pulses with a strict time structure. To meet some experiments which n...Hefei synchrotron radiation Light Source (HLS) is a low energy Syn-chrotron Radiation (SR) facility. The SR produced from the HLS is in a series of pulses with a strict time structure. To meet some experiments which need long interval SR pulses, a new method, local vertical bump, was proposed. Physical calculations and numerical simulations have been done to demonstrate its feasibility.展开更多
BEPCII has two rings each with an injection system. The injection system of each ring consists of two kicker magnets and a septum magnet. The injection layout of two rings is the same. Both two kickers would kick the ...BEPCII has two rings each with an injection system. The injection system of each ring consists of two kicker magnets and a septum magnet. The injection layout of two rings is the same. Both two kickers would kick the beam in horizontal plane. The betatron phase advance in the horizontal plane between two kickers is designed exactly 180° in order to reduce the perturbation to the circulating beams during injection. In fact, the residual orbit oscillation will originate because of the existence of a variety of errors. The Librea Electron BPM processor is used to acquire the beam position data in turn-by-turn mode and to analyze the residual orbit oscillation. According to the measurement results, minimization of the residual orbit oscillation can be done by adjusting the peak field strength and trigger timing delay of two kickers. With very small residual orbit oscillation the two beams can keep collision condition during the injection.展开更多
基金the National Natural Science Foundation of China(Nos.11975298 and 12175292).
文摘A diffraction-limited storage ring with a multi-bend achromat lattice suffers from a small dynamic aperture for conventional off-axis injection.Thus,a longitudinal on-axis injection scheme based on a new type of crab cavity is proposed in this paper.Particle tracking simulations were performed to study the disturbance of the stored beam and the motion of the injected beam during the injection process.The possibility of multi-bunch injections was discussed.In addition,the effect of the long-range wake field induced by the stored beam was analyzed.A C-band standing-wave crab cavity was designed and produced as requested,and its field distribution was measured.The corresponding results are consistent with the simulation results.
基金Supported by National Natural Science Foundation of China (No. 11175181)
文摘The Hefei light source(HLS) has been upgraded into HLS II, with increased brightness and stability. In this paper, the new injection system is described. Elegant program is used to simulate the particles motion in 6D phase space. In the process of tracking simulation of electrons, the system tolerances and magnet errors are introduced. Influences to the injection efficiency from beam injection deviation are studied. These provide important reference for realizing the Top-up injection.
文摘Hefei synchrotron radiation Light Source (HLS) is a low energy Syn-chrotron Radiation (SR) facility. The SR produced from the HLS is in a series of pulses with a strict time structure. To meet some experiments which need long interval SR pulses, a new method, local vertical bump, was proposed. Physical calculations and numerical simulations have been done to demonstrate its feasibility.
文摘BEPCII has two rings each with an injection system. The injection system of each ring consists of two kicker magnets and a septum magnet. The injection layout of two rings is the same. Both two kickers would kick the beam in horizontal plane. The betatron phase advance in the horizontal plane between two kickers is designed exactly 180° in order to reduce the perturbation to the circulating beams during injection. In fact, the residual orbit oscillation will originate because of the existence of a variety of errors. The Librea Electron BPM processor is used to acquire the beam position data in turn-by-turn mode and to analyze the residual orbit oscillation. According to the measurement results, minimization of the residual orbit oscillation can be done by adjusting the peak field strength and trigger timing delay of two kickers. With very small residual orbit oscillation the two beams can keep collision condition during the injection.