In the field of analog VLSI design, current conveyors have reasonably established their identity as an important circuit design element. In the literature published during the past few years, numerous application have...In the field of analog VLSI design, current conveyors have reasonably established their identity as an important circuit design element. In the literature published during the past few years, numerous application have been reported which are based on a variety of current conveyors. In this paper, an oscillator circuit has been proposed. This oscillator is designed using a single positive type second generation current controlled current conveyor (CCCII+). A CCCII has parasitic input resistance on it’s current input node. This resistance could be exploited to reduce circuit complexities. Thus in this accord, a novel oscillator circuit is proposed which utilizes the parasitic resistance of the CCCII+ along with a few more passive components.展开更多
High-temperature superconducting(HTS)rare-earth Ba_(2)Cu_(3)O_(7-x)(REBCO)coated conductors(CCs)have significant potential in high-current and high-field applications.However,owing to the weak interface strength of th...High-temperature superconducting(HTS)rare-earth Ba_(2)Cu_(3)O_(7-x)(REBCO)coated conductors(CCs)have significant potential in high-current and high-field applications.However,owing to the weak interface strength of the laminated composite REBCO CCs,the damage induced by the thermal mismatch stress under a combination of epoxy impregnation,cooling,and quenching can cause premature degradation of the critical current.In this study,a three-dimensional(3D)electromagnetic-thermal-mechanical model based on the H-formulation and cohesive zone model(CZM)is developed to study the critical current degradation characteristics in an epoxy-impregnated REBCO CC caused by the damage during a quench.The temperature variation,critical current degradation of the REBCO CC,and its degradation onset temperature calculated by the numerical model are in agreement with the experimental data taken from the literature.The delamination of the REBCO CC predicted by the numerical model is consistent with the experimental result.The numerical results also indicate that the shear stress is the main contributor to the damage propagation inside the REBCO CC.The premature degradation of the critical current during a quench is closely related to the interface shear strength inside the REBCO CC.Finally,the effects of the coefficient of thermal expansion(CTE)of the epoxy resin,thickness of the substrate,and substrate material on the critical current degradation characteristics of the epoxy-impregnated REBCO CC during a quench are also discussed.These results help us understand the relationship between the current-carrying degradation and damage in the HTS applications.展开更多
A new circuit for realization of universal current-mode filter using current Follower Transconductance Amplifiers (CFTAs) is presented. The proposed circuit realizes current-mode low pass, high pass and band pass filt...A new circuit for realization of universal current-mode filter using current Follower Transconductance Amplifiers (CFTAs) is presented. The proposed circuit realizes current-mode low pass, high pass and band pass filter functions simultaneously with a single current source at the input. The band reject and all pass filters can also be obtained from the proposed circuit without any extra hardware. The proposed circuit employs three passive grounded elements and two CFTAs. Linear electronic control of natural frequency ω0 is available in the proposed circuit. The quality factor can be independently adjusted through grounded resistor. The proposed circuit employs two grounded capacitors and a grounded resistor along with two CFTAs. The grounded resistor can be replaced by an OTA based circuit for linear electronic control of quality factor Q0. The circuit exhibits low active and passive sensitivities for ω0 and Q0. Simulation results are obtained using PSPICE software which is in conformity with the theoretical findings.展开更多
文摘In the field of analog VLSI design, current conveyors have reasonably established their identity as an important circuit design element. In the literature published during the past few years, numerous application have been reported which are based on a variety of current conveyors. In this paper, an oscillator circuit has been proposed. This oscillator is designed using a single positive type second generation current controlled current conveyor (CCCII+). A CCCII has parasitic input resistance on it’s current input node. This resistance could be exploited to reduce circuit complexities. Thus in this accord, a novel oscillator circuit is proposed which utilizes the parasitic resistance of the CCCII+ along with a few more passive components.
基金Project supported by the National Natural Science Foundation of China(Nos.12302278,U2241267,12172155,and 11932008)the Fundamental Research Funds for the Central Universities of China(No.lzujbky-2022-48)the Natural Science Foundation of Gansu Province of China(No.24JRRA473)。
文摘High-temperature superconducting(HTS)rare-earth Ba_(2)Cu_(3)O_(7-x)(REBCO)coated conductors(CCs)have significant potential in high-current and high-field applications.However,owing to the weak interface strength of the laminated composite REBCO CCs,the damage induced by the thermal mismatch stress under a combination of epoxy impregnation,cooling,and quenching can cause premature degradation of the critical current.In this study,a three-dimensional(3D)electromagnetic-thermal-mechanical model based on the H-formulation and cohesive zone model(CZM)is developed to study the critical current degradation characteristics in an epoxy-impregnated REBCO CC caused by the damage during a quench.The temperature variation,critical current degradation of the REBCO CC,and its degradation onset temperature calculated by the numerical model are in agreement with the experimental data taken from the literature.The delamination of the REBCO CC predicted by the numerical model is consistent with the experimental result.The numerical results also indicate that the shear stress is the main contributor to the damage propagation inside the REBCO CC.The premature degradation of the critical current during a quench is closely related to the interface shear strength inside the REBCO CC.Finally,the effects of the coefficient of thermal expansion(CTE)of the epoxy resin,thickness of the substrate,and substrate material on the critical current degradation characteristics of the epoxy-impregnated REBCO CC during a quench are also discussed.These results help us understand the relationship between the current-carrying degradation and damage in the HTS applications.
文摘A new circuit for realization of universal current-mode filter using current Follower Transconductance Amplifiers (CFTAs) is presented. The proposed circuit realizes current-mode low pass, high pass and band pass filter functions simultaneously with a single current source at the input. The band reject and all pass filters can also be obtained from the proposed circuit without any extra hardware. The proposed circuit employs three passive grounded elements and two CFTAs. Linear electronic control of natural frequency ω0 is available in the proposed circuit. The quality factor can be independently adjusted through grounded resistor. The proposed circuit employs two grounded capacitors and a grounded resistor along with two CFTAs. The grounded resistor can be replaced by an OTA based circuit for linear electronic control of quality factor Q0. The circuit exhibits low active and passive sensitivities for ω0 and Q0. Simulation results are obtained using PSPICE software which is in conformity with the theoretical findings.