Time delay and integration (TDI) charge coupled device (CCD) noise sets a fundamental limit on image sensor performance, especially under low illumination in remote sensing applications. After introducing the comp...Time delay and integration (TDI) charge coupled device (CCD) noise sets a fundamental limit on image sensor performance, especially under low illumination in remote sensing applications. After introducing the complete sources of CCD noise, we study the effects of TDI operation mode on noise, and the relationship between different types of noise and number of the TDI stage. Then we propose a new technique to identify and measure sources of TDI CCD noise employing mathematical statistics theory, where theoretical analysis shows that noise estimated formulation converges well. Finally, we establish a testing platform to carry out experiments, and a standard TDI CCD is calibrated by using the proposed method. The experimental results show that the noise analysis and measurement methods presented in this paper are useful for modeling TDI CCDs.展开更多
<div style="text-align:justify;"> In this study, a two-dimensional model describing thermal stress on a charge-coupled device (CCD) induced by ms laser pulses was examined. Considering the nonlinearity...<div style="text-align:justify;"> In this study, a two-dimensional model describing thermal stress on a charge-coupled device (CCD) induced by ms laser pulses was examined. Considering the nonlinearity of the CCD’s material parameters and the melting phase transition process of aluminum electrode materials was considered by using equivalent specific heat capacity method, the physical process where a laser pulse irradiating a CCD pixel array was simulated using COMSOL Multiphysics software. The temperature field and thermal stress field were calculated and analyzed. In order to clarify the mechanism producing damage on the CCD detector, Raman spectra from silicon were measured with a micro-Raman spectrometer to determine stress change in the CCD chip. The procedure presented herein illustrates a method for evaluating strain in a CCD after laser irradiation. </div>展开更多
An experimental method to study the influence of surface contamination of a thinned, backside illuminated charge-coupled device(CCD) upon its quantum efficiency in soft X-ray region is suggested. A transmission gratin...An experimental method to study the influence of surface contamination of a thinned, backside illuminated charge-coupled device(CCD) upon its quantum efficiency in soft X-ray region is suggested. A transmission grating spectrometer(TGS), in which the transmission grating is coupled to a thinned, backside illuminated charge coupled device, is used to measure the continuum X-ray emission from the end of cylindrical target irradiated by laser. In the measured spectra, only the carbon K absorption edge at wavelength of 4.4 um due to condensation of the vacuum oil oil the CCD surface is clearly seen. The surface contamination is considered as an effective "carbon filter" and the filter absorption to correct the quantum efficiency of the CCD camera is taken into account. The effective thickness of the carbon filter is determined by comparing the jump height of the measured spectra at 4.4um with those of the carbon absorption coefficient curves obtained from various carbon thickness. The accuracy of this method is tested by comparing the X-ray spectrum measured by the TGS with that obtained by a soft X-ray spectrometer.展开更多
Objective: To observe the tested results of the segmental range of motion (ROM) of lumbar spine by charge couple device (CCD)-based system for 3-dimensional real-time positioning (CCD system), and to analyze it...Objective: To observe the tested results of the segmental range of motion (ROM) of lumbar spine by charge couple device (CCD)-based system for 3-dimensional real-time positioning (CCD system), and to analyze its clinical significance. Methods: Seven patients with lumbar joint dysfunction and 8 healthy subjects were tested twice by the CCD-based system with an interval of 10 min. Results: The ROM of the patients was obviously lesser than that of the healthy subjects. The measuring data of segmental ROM of lumbar spine by CCD system is correlated significantly to the same data checked later on the same subjects in every direction of the movements. The differences between two checks are usually less than 1 degree. Conclusion: Specially designed CCD based system for 3-dimensional real-time positioning could objectively reflect the segmental ROM of lumbar spine. The system would be of great clinical significance in the assessment of the biomechanical dysfunction of lumbar spine and the effect of the treatment applied.展开更多
A two-wavelength pyrometry device using ordinary array CCD (charge coupled device) to collect the ra- diation data in the horizontal and vertical directions has been developed for measuring the cathode surface tempera...A two-wavelength pyrometry device using ordinary array CCD (charge coupled device) to collect the ra- diation data in the horizontal and vertical directions has been developed for measuring the cathode surface temperature during the arc discharge. Analyses of experimental results show that the device can make the measurement of the cathode surface temperature feasible. The cathode surface temperatures measured are lower than the melting point of tungsten (3653 K), and the arc current, cathode diameter, and the cathode length are the main influencing factors of the cathode surface temperature.展开更多
A Princeton Instruments PI-LCX 1300 charge-coupled device (CCD) camera used for X-ray spectrum measurements in laser-plasma experiments is calibrated using three radioactive sources and investigated with the Monte C...A Princeton Instruments PI-LCX 1300 charge-coupled device (CCD) camera used for X-ray spectrum measurements in laser-plasma experiments is calibrated using three radioactive sources and investigated with the Monte Carlo code Geant4. The exposure level is controlled to make the CCD work in single photon counting mode. A summation algorithm for obtaining accurate X-ray spectra is developed to reconstruct the X-ray spectra, and the results show that the developed algorithm effectively reduces the low-energy tail caused by split pixel events. The obtained CCD energy response shows good linearity. The detection efficiency curves from both Monte Carlo simulations and the manufacturer agree well with the experimental results. This consistency demonstrates that event losses in charge collection processes are negligible when the developed summation algorithm of sDlit Dixel events is emDloved.展开更多
A stable and homogeneous well-aligned air microplasma device for application at atmospheric pressure is designed and its electrical and optical characteristics are investigated. Current-voltage measurements and intens...A stable and homogeneous well-aligned air microplasma device for application at atmospheric pressure is designed and its electrical and optical characteristics are investigated. Current-voltage measurements and intensified charge coupled device (ICCD) images show that the well-aligned air microplasma device is able to generate a large-area and homogeneous discharge at the applied voltages ranging from 12 kV to 14 kV, with a repetition frequency of 5 kHz, which is attributed to the diffusion effect of plasma on dielectric surface. Moreover, this well-aligned microplasma device may result in the uniform and large-area surface modification of heat-sensitive PET polymers without damage, such as optimization in hydrophobicity and biocompatibility. In the biomedical field, the utility of this well-aligned microplasma device is further testified. It proves to be very efficient for the large-area and uniform inactivation of E. coli cells with a density of 103/cm2 on LB agar plate culture medium, and inactivation efficiency can reach up to 99% for 2-min treatment.展开更多
A nonlinearity measurement of the charge-coupled device(CCD) array spectrometer using flux addition and comparison method is described. The light with various colors from the colorful light emitting diode(LED) light s...A nonlinearity measurement of the charge-coupled device(CCD) array spectrometer using flux addition and comparison method is described. The light with various colors from the colorful light emitting diode(LED) light source is applied to measure the nonlinearity of the spectrometer at different wavelengths, respectively. An high-end CCD array spectrometer is tested. For colorful LED light sources, the nonlinearity factors of the CCD array spectrometer(absolute value) are as follows: k<0.8% for white light, k <1.1% for red light, k <2.2% for green light and k<4.7% for blue light. By using those quasi-monochromatic light sources, it is shown that the nonlinearity depends on the wavelength. It is important to be wariness about the spectral nonlinearity and related uncertainty evaluation when the narrow-band light source is tested.展开更多
基金Project supported by the National High Technology Research and Development Program of China (Grant No. 2006AA06A208)
文摘Time delay and integration (TDI) charge coupled device (CCD) noise sets a fundamental limit on image sensor performance, especially under low illumination in remote sensing applications. After introducing the complete sources of CCD noise, we study the effects of TDI operation mode on noise, and the relationship between different types of noise and number of the TDI stage. Then we propose a new technique to identify and measure sources of TDI CCD noise employing mathematical statistics theory, where theoretical analysis shows that noise estimated formulation converges well. Finally, we establish a testing platform to carry out experiments, and a standard TDI CCD is calibrated by using the proposed method. The experimental results show that the noise analysis and measurement methods presented in this paper are useful for modeling TDI CCDs.
文摘<div style="text-align:justify;"> In this study, a two-dimensional model describing thermal stress on a charge-coupled device (CCD) induced by ms laser pulses was examined. Considering the nonlinearity of the CCD’s material parameters and the melting phase transition process of aluminum electrode materials was considered by using equivalent specific heat capacity method, the physical process where a laser pulse irradiating a CCD pixel array was simulated using COMSOL Multiphysics software. The temperature field and thermal stress field were calculated and analyzed. In order to clarify the mechanism producing damage on the CCD detector, Raman spectra from silicon were measured with a micro-Raman spectrometer to determine stress change in the CCD chip. The procedure presented herein illustrates a method for evaluating strain in a CCD after laser irradiation. </div>
基金the National High-Technolog Project (No. 863-416-3)
文摘An experimental method to study the influence of surface contamination of a thinned, backside illuminated charge-coupled device(CCD) upon its quantum efficiency in soft X-ray region is suggested. A transmission grating spectrometer(TGS), in which the transmission grating is coupled to a thinned, backside illuminated charge coupled device, is used to measure the continuum X-ray emission from the end of cylindrical target irradiated by laser. In the measured spectra, only the carbon K absorption edge at wavelength of 4.4 um due to condensation of the vacuum oil oil the CCD surface is clearly seen. The surface contamination is considered as an effective "carbon filter" and the filter absorption to correct the quantum efficiency of the CCD camera is taken into account. The effective thickness of the carbon filter is determined by comparing the jump height of the measured spectra at 4.4um with those of the carbon absorption coefficient curves obtained from various carbon thickness. The accuracy of this method is tested by comparing the X-ray spectrum measured by the TGS with that obtained by a soft X-ray spectrometer.
文摘Objective: To observe the tested results of the segmental range of motion (ROM) of lumbar spine by charge couple device (CCD)-based system for 3-dimensional real-time positioning (CCD system), and to analyze its clinical significance. Methods: Seven patients with lumbar joint dysfunction and 8 healthy subjects were tested twice by the CCD-based system with an interval of 10 min. Results: The ROM of the patients was obviously lesser than that of the healthy subjects. The measuring data of segmental ROM of lumbar spine by CCD system is correlated significantly to the same data checked later on the same subjects in every direction of the movements. The differences between two checks are usually less than 1 degree. Conclusion: Specially designed CCD based system for 3-dimensional real-time positioning could objectively reflect the segmental ROM of lumbar spine. The system would be of great clinical significance in the assessment of the biomechanical dysfunction of lumbar spine and the effect of the treatment applied.
文摘A two-wavelength pyrometry device using ordinary array CCD (charge coupled device) to collect the ra- diation data in the horizontal and vertical directions has been developed for measuring the cathode surface temperature during the arc discharge. Analyses of experimental results show that the device can make the measurement of the cathode surface temperature feasible. The cathode surface temperatures measured are lower than the melting point of tungsten (3653 K), and the arc current, cathode diameter, and the cathode length are the main influencing factors of the cathode surface temperature.
基金supported by the National Natural Science Foundation of China(Nos.10975121,10905051,10902051,and 11174259)the Foundation of CAEP(Nos.2009A0102003 and 2011B0102021)the Foundation of Science and Technology on Plasma Physics Laboratory(No.9140C6802041004)
文摘A Princeton Instruments PI-LCX 1300 charge-coupled device (CCD) camera used for X-ray spectrum measurements in laser-plasma experiments is calibrated using three radioactive sources and investigated with the Monte Carlo code Geant4. The exposure level is controlled to make the CCD work in single photon counting mode. A summation algorithm for obtaining accurate X-ray spectra is developed to reconstruct the X-ray spectra, and the results show that the developed algorithm effectively reduces the low-energy tail caused by split pixel events. The obtained CCD energy response shows good linearity. The detection efficiency curves from both Monte Carlo simulations and the manufacturer agree well with the experimental results. This consistency demonstrates that event losses in charge collection processes are negligible when the developed summation algorithm of sDlit Dixel events is emDloved.
基金supported by the Natural Science Foundation of Fujian Province,China(Grant No.2014J01025)the National Natural Science Foundation of China(Grant No.11275261)+1 种基金the Natural Science Foundation of Guangdong Province,China(Grant No.2015A030313005)the Fund from the Fujian Provincia Key Laboratory for Plasma and Magnetic Resonance,China
文摘A stable and homogeneous well-aligned air microplasma device for application at atmospheric pressure is designed and its electrical and optical characteristics are investigated. Current-voltage measurements and intensified charge coupled device (ICCD) images show that the well-aligned air microplasma device is able to generate a large-area and homogeneous discharge at the applied voltages ranging from 12 kV to 14 kV, with a repetition frequency of 5 kHz, which is attributed to the diffusion effect of plasma on dielectric surface. Moreover, this well-aligned microplasma device may result in the uniform and large-area surface modification of heat-sensitive PET polymers without damage, such as optimization in hydrophobicity and biocompatibility. In the biomedical field, the utility of this well-aligned microplasma device is further testified. It proves to be very efficient for the large-area and uniform inactivation of E. coli cells with a density of 103/cm2 on LB agar plate culture medium, and inactivation efficiency can reach up to 99% for 2-min treatment.
基金supported by the National Natural Science Foundation of China(No.61505191)
文摘A nonlinearity measurement of the charge-coupled device(CCD) array spectrometer using flux addition and comparison method is described. The light with various colors from the colorful light emitting diode(LED) light source is applied to measure the nonlinearity of the spectrometer at different wavelengths, respectively. An high-end CCD array spectrometer is tested. For colorful LED light sources, the nonlinearity factors of the CCD array spectrometer(absolute value) are as follows: k<0.8% for white light, k <1.1% for red light, k <2.2% for green light and k<4.7% for blue light. By using those quasi-monochromatic light sources, it is shown that the nonlinearity depends on the wavelength. It is important to be wariness about the spectral nonlinearity and related uncertainty evaluation when the narrow-band light source is tested.