The numerical modeling for the cool water outfall discharge from the LNG Plant is undertaken using CORMIX to evaluate the design of diffuser for discharge. The hydrodynamic data tide and currents are used inputs to th...The numerical modeling for the cool water outfall discharge from the LNG Plant is undertaken using CORMIX to evaluate the design of diffuser for discharge. The hydrodynamic data tide and currents are used inputs to the model. It is then calibrated using monitored data. The software has been run to calculate the mixing zone and dilution patterns for various flow conditions. Model result shows that ambient condition is achieved within 64 m from the proposed outfall locations. From the results of the modeling studies it can be concluded that the proposed diffuser design and outfall locations are suitable for all tide conditions. It also shows that there is no significant impact on the marine life due to the proposed cool water discharge, beyond the small area around the discharge location, as the parameters are attaining near ambient water quality within the acceptable space and time.展开更多
This pilot study intended to investigate the application of Mixing Zone Guidelines in northern Sweden. The EC (European Commission)-Mixing Zone Guidelines were applied to seven effluent discharges. The effluents wer...This pilot study intended to investigate the application of Mixing Zone Guidelines in northern Sweden. The EC (European Commission)-Mixing Zone Guidelines were applied to seven effluent discharges. The effluents were from industrial processes used in the Ronnskar smelter, in northern Sweden. Each outlet in the smelter area discharges water into the Bothnian bay of the Baltic Sea. Cadmium (Cd), mercury (Hg), nickel (Ni) and lead (Pb) were the primary substances present in the effluents. A "Tiered Approach" was followed for mixing zone assessments in each of the discharge points. Discharge Test was used at Tier 2 and CORMIX (Cornell Mixing Zone Expert System model), version 7, at Tier 3. At each discharge point, the AA-EQS (annual average-environmental quality standard) for each metal was met within a distance of 500 m from the outfalls. This distance was exceeded to meet the MAC-EQS (maximum allowable concentration-environmental quality standard) criteria at points 1 and 3 for total Hg concentrations. However, for the proper application of Mixing Zone Guidelines, a version of the Discharge Test for coastal waters should be developed and used. The decision at which tier the dissolved metal concentration should be compared with EQS values could depend on the effluent characteristics. For Swedish coastal waters, some consideration should be given to the background concentration of metals.展开更多
文摘The numerical modeling for the cool water outfall discharge from the LNG Plant is undertaken using CORMIX to evaluate the design of diffuser for discharge. The hydrodynamic data tide and currents are used inputs to the model. It is then calibrated using monitored data. The software has been run to calculate the mixing zone and dilution patterns for various flow conditions. Model result shows that ambient condition is achieved within 64 m from the proposed outfall locations. From the results of the modeling studies it can be concluded that the proposed diffuser design and outfall locations are suitable for all tide conditions. It also shows that there is no significant impact on the marine life due to the proposed cool water discharge, beyond the small area around the discharge location, as the parameters are attaining near ambient water quality within the acceptable space and time.
文摘This pilot study intended to investigate the application of Mixing Zone Guidelines in northern Sweden. The EC (European Commission)-Mixing Zone Guidelines were applied to seven effluent discharges. The effluents were from industrial processes used in the Ronnskar smelter, in northern Sweden. Each outlet in the smelter area discharges water into the Bothnian bay of the Baltic Sea. Cadmium (Cd), mercury (Hg), nickel (Ni) and lead (Pb) were the primary substances present in the effluents. A "Tiered Approach" was followed for mixing zone assessments in each of the discharge points. Discharge Test was used at Tier 2 and CORMIX (Cornell Mixing Zone Expert System model), version 7, at Tier 3. At each discharge point, the AA-EQS (annual average-environmental quality standard) for each metal was met within a distance of 500 m from the outfalls. This distance was exceeded to meet the MAC-EQS (maximum allowable concentration-environmental quality standard) criteria at points 1 and 3 for total Hg concentrations. However, for the proper application of Mixing Zone Guidelines, a version of the Discharge Test for coastal waters should be developed and used. The decision at which tier the dissolved metal concentration should be compared with EQS values could depend on the effluent characteristics. For Swedish coastal waters, some consideration should be given to the background concentration of metals.