The pore structure images of ore particles located at different heights of leaching column were scanned with X-ray computerized tomography (CT) scanner, the porosity and pore size distribution were calculated and the ...The pore structure images of ore particles located at different heights of leaching column were scanned with X-ray computerized tomography (CT) scanner, the porosity and pore size distribution were calculated and the geometrical shape and connectivity of pores were analyzed based on image process method, and the three dimensional reconstruction of pore structure images was realized. The results show that the porosity of ore particles bed in leaching column is 42.92%, 41.72%, 39.34% at top, middle and bottom zone, respectively. Obviously it has spatial variability and decreases appreciably along the height of the column. The overall average porosity obtained by image processing is 41.33% while the porosity gotten from general measurement method in laboratory is 42.77% showing the results of both methods are consistent well. The pore structure of ore granular media is characterized as a dynamical space network composed of interconnected pore bodies and pore throats. The ratio of throats with equivalent diameter less than 1.91 mm to the total pores is 29.31%, and that of the large pores with equivalent diameter more than 5.73 mm is 2.90%.展开更多
The geometry of joints has a significant influence on the mechanical properties of rocks.To simplify the curved joint shapes in rocks,the joint shape is usually treated as straight lines or planes in most laboratory e...The geometry of joints has a significant influence on the mechanical properties of rocks.To simplify the curved joint shapes in rocks,the joint shape is usually treated as straight lines or planes in most laboratory experiments and numerical simulations.In this study,the computerized tomography (CT) scanning and photogrammetry were employed to obtain the internal and surface joint structures of a limestone sample,respectively.To describe the joint geometry,the edge detection algorithms and a three-dimensional (3D) matrix mapping method were applied to reconstruct CT-based and photogrammetry-based jointed rock models.For comparison tests,the numerical uniaxial compression tests were conducted on an intact rock sample and a sample with a joint simplified to a plane using the parallel computing method.The results indicate that the mechanical characteristics and failure process of jointed rocks are significantly affected by the geometry of joints.The presence of joints reduces the uniaxial compressive strength (UCS),elastic modulus,and released acoustic emission (AE) energy of rocks by 37%–67%,21%–24%,and 52%–90%,respectively.Compared to the simplified joint sample,the proposed photogrammetry-based numerical model makes the most of the limited geometry information of joints.The UCS,accumulative released AE energy,and elastic modulus of the photogrammetry-based sample were found to be very close to those of the CT-based sample.The UCS value of the simplified joint sample (i.e.38.5 MPa) is much lower than that of the CT-based sample (i.e.72.3 MPa).Additionally,the accumulative released AE energy observed in the simplified joint sample is 3.899 times lower than that observed in the CT-based sample.CT scanning provides a reliable means to visualize the joints in rocks,which can be used to verify the reliability of photogrammetry techniques.The application of the photogrammetry-based sample enables detailed analysis for estimating the mechanical properties of jointed rocks.展开更多
It is an active research area to reconstruct 3-D object and display its visible surfacesfrom cross-sectional images. In this paper, the methods of reconstructing 3-D object from medicalCT images and displaying the vis...It is an active research area to reconstruct 3-D object and display its visible surfacesfrom cross-sectional images. In this paper, the methods of reconstructing 3-D object from medicalCT images and displaying the visible surfaces are discussed. A polygon approximation methodthat forms polygon with the same number of segment points and a fast interpolation method forcross-sectional contours are presented at first. Then the voxel set of a human liver is reconstructed.And then the liver voxel set is displayed using depth and gradient shading methods. The softwareis written in C programming language at a microcomputer image processing system with a PC/ATcomputer as the host and a PC-VISION board as the image processing unit. The result of theprocessing is satisfying.展开更多
The relationship between noise variance and spatial resolution in grating-based x-ray phase computed tomography(PCT) imaging is investigated with reverse projection extraction method, and the noise variances of the ...The relationship between noise variance and spatial resolution in grating-based x-ray phase computed tomography(PCT) imaging is investigated with reverse projection extraction method, and the noise variances of the reconstructed absorption coefficient and refractive index decrement are compared. For the differential phase contrast method, the noise variance in the differential projection images follows the same inverse-square law with spatial resolution as in conventional absorption-based x-ray imaging projections. However, both theoretical analysis and simulations demonstrate that in PCT the noise variance of the reconstructed refractive index decrement scales with spatial resolution follows an inverse linear relationship at fixed slice thickness, while the noise variance of the reconstructed absorption coefficient conforms with the inverse cubic law. The results indicate that, for the same noise variance level, PCT imaging may enable higher spatial resolution than conventional absorption computed tomography(ACT), while ACT benefits more from degraded spatial resolution. This could be a useful guidance in imaging the inner structure of the sample in higher spatial resolution.展开更多
Objective: Computerized tomography (CT) plays an important role in the diagnosis of diseases of biliary tract. Recently, three dimensions (3D) spiral CT imaging has been used in surgical diseases gradually. This study...Objective: Computerized tomography (CT) plays an important role in the diagnosis of diseases of biliary tract. Recently, three dimensions (3D) spiral CT imaging has been used in surgical diseases gradually. This study was designed to evaluate the diagnostic value of 3D spiral CT imaging of cholangiopancreatic ducts on obstructive jaundice. Methods: Thirty patients with obstructive jaundice had received B-mode ultrasonography, CT, percutaneous transhepatic cholangiography (PTC) or endoscopic retrograde cholangiopancreatography (ERCP), and 3D spiral CT imaging of cholangiopancreatic ducts preoperatively. Then the diagnose accordance rate of these examinational methods were compared after operations. Results: The diagnose accordance rate of 3D spiral CT imaging of cholangiopancreatic ducts was higher than those of B-mode ultrasonography, CT, or single PTC or ERCP, which showed clear images of bile duct tree and pathological changes. As to malignant obstructive jaundice, this examinational technique could clearly display the adjacent relationship between tumor and liver tissue, biliary ducts, blood vessels, and intrahepatic metastases. Conclusion: 3D spiral CT imaging of cholangiopancreatic ducts has significant value for obstructive diseases of biliary ducts, which provides effective evidence for the feasibility of tumor-resection and surgical options.展开更多
基金Project(2004CB619205) supported by the National Key Fundamental Research and Development Program of ChinaProject(50325415) supported by the National Science Fund for Distinguished Young ScholarsProject(50574099) supported by the National Natural Science Foundation of China
文摘The pore structure images of ore particles located at different heights of leaching column were scanned with X-ray computerized tomography (CT) scanner, the porosity and pore size distribution were calculated and the geometrical shape and connectivity of pores were analyzed based on image process method, and the three dimensional reconstruction of pore structure images was realized. The results show that the porosity of ore particles bed in leaching column is 42.92%, 41.72%, 39.34% at top, middle and bottom zone, respectively. Obviously it has spatial variability and decreases appreciably along the height of the column. The overall average porosity obtained by image processing is 41.33% while the porosity gotten from general measurement method in laboratory is 42.77% showing the results of both methods are consistent well. The pore structure of ore granular media is characterized as a dynamical space network composed of interconnected pore bodies and pore throats. The ratio of throats with equivalent diameter less than 1.91 mm to the total pores is 29.31%, and that of the large pores with equivalent diameter more than 5.73 mm is 2.90%.
基金supported by the National Natural Science Foundation of China(Grant Nos.42277150,41977219)Henan Provincial Science and Technology Research Project(Grant No.222102320271).
文摘The geometry of joints has a significant influence on the mechanical properties of rocks.To simplify the curved joint shapes in rocks,the joint shape is usually treated as straight lines or planes in most laboratory experiments and numerical simulations.In this study,the computerized tomography (CT) scanning and photogrammetry were employed to obtain the internal and surface joint structures of a limestone sample,respectively.To describe the joint geometry,the edge detection algorithms and a three-dimensional (3D) matrix mapping method were applied to reconstruct CT-based and photogrammetry-based jointed rock models.For comparison tests,the numerical uniaxial compression tests were conducted on an intact rock sample and a sample with a joint simplified to a plane using the parallel computing method.The results indicate that the mechanical characteristics and failure process of jointed rocks are significantly affected by the geometry of joints.The presence of joints reduces the uniaxial compressive strength (UCS),elastic modulus,and released acoustic emission (AE) energy of rocks by 37%–67%,21%–24%,and 52%–90%,respectively.Compared to the simplified joint sample,the proposed photogrammetry-based numerical model makes the most of the limited geometry information of joints.The UCS,accumulative released AE energy,and elastic modulus of the photogrammetry-based sample were found to be very close to those of the CT-based sample.The UCS value of the simplified joint sample (i.e.38.5 MPa) is much lower than that of the CT-based sample (i.e.72.3 MPa).Additionally,the accumulative released AE energy observed in the simplified joint sample is 3.899 times lower than that observed in the CT-based sample.CT scanning provides a reliable means to visualize the joints in rocks,which can be used to verify the reliability of photogrammetry techniques.The application of the photogrammetry-based sample enables detailed analysis for estimating the mechanical properties of jointed rocks.
文摘It is an active research area to reconstruct 3-D object and display its visible surfacesfrom cross-sectional images. In this paper, the methods of reconstructing 3-D object from medicalCT images and displaying the visible surfaces are discussed. A polygon approximation methodthat forms polygon with the same number of segment points and a fast interpolation method forcross-sectional contours are presented at first. Then the voxel set of a human liver is reconstructed.And then the liver voxel set is displayed using depth and gradient shading methods. The softwareis written in C programming language at a microcomputer image processing system with a PC/ATcomputer as the host and a PC-VISION board as the image processing unit. The result of theprocessing is satisfying.
基金Project supported by the National Basic Research Program of China(Grant No.2012CB825800)the Science Fund for Creative Research Groups,the Knowledge Innovation Program of the Chinese Academy of Sciences(Grant Nos.KJCX2-YW-N42 and Y4545320Y2)the National Natural Science Foundation of China(Grant Nos.11475170,11205157,11305173,11205189,11375225,11321503,11179004,and U1332109)
文摘The relationship between noise variance and spatial resolution in grating-based x-ray phase computed tomography(PCT) imaging is investigated with reverse projection extraction method, and the noise variances of the reconstructed absorption coefficient and refractive index decrement are compared. For the differential phase contrast method, the noise variance in the differential projection images follows the same inverse-square law with spatial resolution as in conventional absorption-based x-ray imaging projections. However, both theoretical analysis and simulations demonstrate that in PCT the noise variance of the reconstructed refractive index decrement scales with spatial resolution follows an inverse linear relationship at fixed slice thickness, while the noise variance of the reconstructed absorption coefficient conforms with the inverse cubic law. The results indicate that, for the same noise variance level, PCT imaging may enable higher spatial resolution than conventional absorption computed tomography(ACT), while ACT benefits more from degraded spatial resolution. This could be a useful guidance in imaging the inner structure of the sample in higher spatial resolution.
基金Supported by a grant of Jiangxi Province Scientific Technologic Foundation (No. E990611)
文摘Objective: Computerized tomography (CT) plays an important role in the diagnosis of diseases of biliary tract. Recently, three dimensions (3D) spiral CT imaging has been used in surgical diseases gradually. This study was designed to evaluate the diagnostic value of 3D spiral CT imaging of cholangiopancreatic ducts on obstructive jaundice. Methods: Thirty patients with obstructive jaundice had received B-mode ultrasonography, CT, percutaneous transhepatic cholangiography (PTC) or endoscopic retrograde cholangiopancreatography (ERCP), and 3D spiral CT imaging of cholangiopancreatic ducts preoperatively. Then the diagnose accordance rate of these examinational methods were compared after operations. Results: The diagnose accordance rate of 3D spiral CT imaging of cholangiopancreatic ducts was higher than those of B-mode ultrasonography, CT, or single PTC or ERCP, which showed clear images of bile duct tree and pathological changes. As to malignant obstructive jaundice, this examinational technique could clearly display the adjacent relationship between tumor and liver tissue, biliary ducts, blood vessels, and intrahepatic metastases. Conclusion: 3D spiral CT imaging of cholangiopancreatic ducts has significant value for obstructive diseases of biliary ducts, which provides effective evidence for the feasibility of tumor-resection and surgical options.