AIM:To compare the repeatability/reproducibility of measurement by high-resolution Placido disk-based topography with that of a high-resolution rotating Scheimpflug camera and assess the agreement between the two ins...AIM:To compare the repeatability/reproducibility of measurement by high-resolution Placido disk-based topography with that of a high-resolution rotating Scheimpflug camera and assess the agreement between the two instruments in measuring corneal power in eyes with keratoconus and post-laser in situ keratomileusis(LASIK). METHODS:One eye each of 36 keratoconic patients and 20 subjects who had undergone LASIK was included in this prospective observational study. Two independent examiners worked in a random order to take three measurements of each eye with both instruments. Four parameters were measured on the anterior cornea:steep keratometry(Ks),flat keratometry(Kf),mean keratometry(Km),and astigmatism(Ks-Kf). Intra-examiner repeatability and inter-examiner reproducibility were evaluated by calculating the within-subject standard deviation(Sw)the coefficient of repeatability(R),the coefficient of variation(Co V),and the intraclass correlation coefficient(ICC). Agreement between instruments was tested with the BlandAltman method by calculating the 95% limits of agreement(95% Lo A).RESULTS:In keratoconic eyes,the intra-examiner and inter-examiner ICC were 〉0.95. As compared with measurement by high-resolution Placido disk-based topography,the intra-examiner R of the high-resolution rotating Scheimpflug camera was lower for Kf(0.32 vs 0.88),Ks(0.61 vs 0.88),and Km(0.32 vs 0.84)but higher for Ks-Kf(0.70 vs 0.57). Inter-examiner R values were lower for all parameters measured using the high-resolution rotating Scheimpflug camera. The 95% Lo A were-1.28 to +0.55 for Kf,-1.36 to +0.99 for Ks,-1.08 to +0.50 for Km,and-1.11 to +1.48 for Ks-Kf. In the post-LASIK eyes,the intra-examiner andinter-examiner ICC were 〉0.87 for all parameters. The intra-examiner and inter-examiner R were lower for all parameters measured using the high-resolution rotating Scheimpflug camera. The intra-examiner R was 0.17 vs 0.88 for Kf,0.21 vs 0.88 for Ks,0.17 vs 0.86 for Km,and 0.28 vs 0.33 for Ks-Kf. The inter-examiner R was 0.09 vs 0.64 for Kf,0.15 vs 0.56 for Ks,0.09 vs 0.59 for Km,and 0.18 vs 0.23 for Ks-Kf. The 95% Lo A were-0.54 to +0.58 for Kf,-0.51 to +0.53 for Ks and Km,and-0.28 to +0.27 for Ks-Kf. CONCLUSION:As compared with Placido disk-based topography,the high-resolution rotating Scheimpflug camera provides more repeatable and reproducible measurements of Ks,Kf and Ks in keratoconic and post-LASIK eyes. Agreement between instruments is fair in keratoconus and very good in post-LASIK eyes.展开更多
A digital camera measuring system has been used successfully to measure the space fluctuation behaviors of Induced Dielectric Barrier Discharge (IDBD) plasma at atmospheric pres- sure. The experimental results showed ...A digital camera measuring system has been used successfully to measure the space fluctuation behaviors of Induced Dielectric Barrier Discharge (IDBD) plasma at atmospheric pres- sure. The experimental results showed that: (1) The uniformity of electron temperature in space depends on discharge condition and structure of web electrode. For a certain web electrode the higher the discharge voltage is, the more uniform distribution of electron temperature in space will be. For a certain discharge the finer and denser the holes on web electrode are, the more uniform distribution of electron temperature in space will be (2). Digital camera is an available equipment to measure some behaviors of the plasma working at atmospheric pressure.展开更多
According to the operational conditions of an aviation module reticule,a measurement mode is proposed,which is based on an industrial photogrammetry system,with matching by a measuring pen.Meanwhile,the factors affect...According to the operational conditions of an aviation module reticule,a measurement mode is proposed,which is based on an industrial photogrammetry system,with matching by a measuring pen.Meanwhile,the factors affecting the accuracy of the measurement have been analyzed and verified by examples.The analysis is described as follows:①Along the optical axis of the camera,the error is larger than the ones in other directions using the“single camera+measuring pen”mode;②By avoiding the error along the optical axis of the camera,the accuracy of the“single camera+measuring pen”mode is better than 0.1 mm when the measuring pen is moving parallel to the optical axis.展开更多
A novel virtual four-ocular stereo measurement system based on single high speed camera is proposed for measuring double beating wings of a high speed flapping insect. The principle of virtual monocular system consist...A novel virtual four-ocular stereo measurement system based on single high speed camera is proposed for measuring double beating wings of a high speed flapping insect. The principle of virtual monocular system consisting of a few planar mirrors and a single high speed camera is introduced. The stereo vision measurement principle based on optic triangulation is explained. The wing kinematics parameters are measured. Results show that this virtual stereo system not only decreases system cost extremely but also is effective to insect motion measurement.展开更多
文摘AIM:To compare the repeatability/reproducibility of measurement by high-resolution Placido disk-based topography with that of a high-resolution rotating Scheimpflug camera and assess the agreement between the two instruments in measuring corneal power in eyes with keratoconus and post-laser in situ keratomileusis(LASIK). METHODS:One eye each of 36 keratoconic patients and 20 subjects who had undergone LASIK was included in this prospective observational study. Two independent examiners worked in a random order to take three measurements of each eye with both instruments. Four parameters were measured on the anterior cornea:steep keratometry(Ks),flat keratometry(Kf),mean keratometry(Km),and astigmatism(Ks-Kf). Intra-examiner repeatability and inter-examiner reproducibility were evaluated by calculating the within-subject standard deviation(Sw)the coefficient of repeatability(R),the coefficient of variation(Co V),and the intraclass correlation coefficient(ICC). Agreement between instruments was tested with the BlandAltman method by calculating the 95% limits of agreement(95% Lo A).RESULTS:In keratoconic eyes,the intra-examiner and inter-examiner ICC were 〉0.95. As compared with measurement by high-resolution Placido disk-based topography,the intra-examiner R of the high-resolution rotating Scheimpflug camera was lower for Kf(0.32 vs 0.88),Ks(0.61 vs 0.88),and Km(0.32 vs 0.84)but higher for Ks-Kf(0.70 vs 0.57). Inter-examiner R values were lower for all parameters measured using the high-resolution rotating Scheimpflug camera. The 95% Lo A were-1.28 to +0.55 for Kf,-1.36 to +0.99 for Ks,-1.08 to +0.50 for Km,and-1.11 to +1.48 for Ks-Kf. In the post-LASIK eyes,the intra-examiner andinter-examiner ICC were 〉0.87 for all parameters. The intra-examiner and inter-examiner R were lower for all parameters measured using the high-resolution rotating Scheimpflug camera. The intra-examiner R was 0.17 vs 0.88 for Kf,0.21 vs 0.88 for Ks,0.17 vs 0.86 for Km,and 0.28 vs 0.33 for Ks-Kf. The inter-examiner R was 0.09 vs 0.64 for Kf,0.15 vs 0.56 for Ks,0.09 vs 0.59 for Km,and 0.18 vs 0.23 for Ks-Kf. The 95% Lo A were-0.54 to +0.58 for Kf,-0.51 to +0.53 for Ks and Km,and-0.28 to +0.27 for Ks-Kf. CONCLUSION:As compared with Placido disk-based topography,the high-resolution rotating Scheimpflug camera provides more repeatable and reproducible measurements of Ks,Kf and Ks in keratoconic and post-LASIK eyes. Agreement between instruments is fair in keratoconus and very good in post-LASIK eyes.
基金This work was supported by National Natural Science Foundation of China No.19775010.
文摘A digital camera measuring system has been used successfully to measure the space fluctuation behaviors of Induced Dielectric Barrier Discharge (IDBD) plasma at atmospheric pres- sure. The experimental results showed that: (1) The uniformity of electron temperature in space depends on discharge condition and structure of web electrode. For a certain web electrode the higher the discharge voltage is, the more uniform distribution of electron temperature in space will be. For a certain discharge the finer and denser the holes on web electrode are, the more uniform distribution of electron temperature in space will be (2). Digital camera is an available equipment to measure some behaviors of the plasma working at atmospheric pressure.
文摘According to the operational conditions of an aviation module reticule,a measurement mode is proposed,which is based on an industrial photogrammetry system,with matching by a measuring pen.Meanwhile,the factors affecting the accuracy of the measurement have been analyzed and verified by examples.The analysis is described as follows:①Along the optical axis of the camera,the error is larger than the ones in other directions using the“single camera+measuring pen”mode;②By avoiding the error along the optical axis of the camera,the accuracy of the“single camera+measuring pen”mode is better than 0.1 mm when the measuring pen is moving parallel to the optical axis.
基金The work was supported by the National Science Fund for Distinguished Young Scholars of China under Grant No. 50125518.
文摘A novel virtual four-ocular stereo measurement system based on single high speed camera is proposed for measuring double beating wings of a high speed flapping insect. The principle of virtual monocular system consisting of a few planar mirrors and a single high speed camera is introduced. The stereo vision measurement principle based on optic triangulation is explained. The wing kinematics parameters are measured. Results show that this virtual stereo system not only decreases system cost extremely but also is effective to insect motion measurement.