In order to detect and recognize infrared target with joint transform correlator,a modified Cassegrain optical system is designed.The main advantages of the system are large field-of-view,infrared dual-band common opt...In order to detect and recognize infrared target with joint transform correlator,a modified Cassegrain optical system is designed.The main advantages of the system are large field-of-view,infrared dual-band common optical path and compact structure.In the modified Cassegrain optical system,the working wavelengths are 3.7~4.8μm and 8~12μm,the field-of-view is 4° and the aperture is 240mm.The paraboloidal primary mirror and hyperboloidal secondary mirror are all replaced by spherical surfaces.So the problems of high machining accuracy and alignment become much easier.In order to balance the aberrations,three compensating lenses are used in the system.The total length of the system is 183mm,and the ratio of the total length to focal length is 0.68.Moreover,the system has a good performance of athermalization between negative 40℃ and positive 60℃.The design results of the system show that the MTF value of each field is greater than 0.72 when the cut-off frequency is 11lp/mm.Due to the excellent image quality of the modified optical system,the ability of Joint transform correlator(JTC)applied in target tracking and identification has been improved for further.展开更多
文摘In order to detect and recognize infrared target with joint transform correlator,a modified Cassegrain optical system is designed.The main advantages of the system are large field-of-view,infrared dual-band common optical path and compact structure.In the modified Cassegrain optical system,the working wavelengths are 3.7~4.8μm and 8~12μm,the field-of-view is 4° and the aperture is 240mm.The paraboloidal primary mirror and hyperboloidal secondary mirror are all replaced by spherical surfaces.So the problems of high machining accuracy and alignment become much easier.In order to balance the aberrations,three compensating lenses are used in the system.The total length of the system is 183mm,and the ratio of the total length to focal length is 0.68.Moreover,the system has a good performance of athermalization between negative 40℃ and positive 60℃.The design results of the system show that the MTF value of each field is greater than 0.72 when the cut-off frequency is 11lp/mm.Due to the excellent image quality of the modified optical system,the ability of Joint transform correlator(JTC)applied in target tracking and identification has been improved for further.