期刊文献+
共找到4,585篇文章
< 1 2 230 >
每页显示 20 50 100
Anatomical variation in the internal jugular vein:potential risk factors for central venous catheterization-a case report
1
作者 Yidan Shan Weijia Huang 《World Journal of Emergency Medicine》 SCIE CAS CSCD 2024年第4期316-318,共3页
Central venous catheterization(CVC)is an invasive medical procedure used to measure central venous pressure and provides a stable route for continuous drug administration.CVC is widely used in the emergency department... Central venous catheterization(CVC)is an invasive medical procedure used to measure central venous pressure and provides a stable route for continuous drug administration.CVC is widely used in the emergency department and intensive care units.It is typically performed by inserting a catheter through the internal jugular vein(IJV)into the superior vena cava near the right atrium.[1,2]While catheterization is a fundamental skill proficiently performed by healthcare professionals,lethal complications may occasionally occur because of undesirable positioning,depth and diameter. 展开更多
关键词 venous CATHETER JUGULAR
下载PDF
Comparison of intraosseous access and central venous catheterization in Chinese adult emergency patients: A prospective, multicenter, and randomized study 被引量:7
2
作者 Yan-yan Liu Yu-peng Wang +4 位作者 Ling-yun Zu Kang Zheng Qing-bian Ma Ya-an Zheng Wei Gao 《World Journal of Emergency Medicine》 SCIE CAS CSCD 2021年第2期105-110,共6页
BACKGROUND: It is challenging to establish peripheral intravenous access in adult critically patients. This study aims to compare the success rate of the first attempt, procedure time, operator satisfaction with the u... BACKGROUND: It is challenging to establish peripheral intravenous access in adult critically patients. This study aims to compare the success rate of the first attempt, procedure time, operator satisfaction with the used devices, pain score, and complications between intraosseous(IO) access and central venous catheterization(CVC) in critically ill Chinese patients.METHODS: In this prospective clustered randomized controlled trial, eight hospitals were randomly divided into either the IO group or the CVC group. Patients who needed emergency vascular access were included. From April 1, 2017 to December 31, 2018, each center included 12 patients. We recorded the data mentioned above.RESULTS: A total of 96 patients were enrolled in the study. There were no statistically significant differences between the two groups regarding sex, age, body mass index, or operator satisfaction with the used devices. The success rates of the first attempt and the procedure time were statistically significant between the IO group and the CVC group(91.7% vs. 50.0%, P<0.001;52.0 seconds vs. 900.0 seconds, P<0.001). During the study, 32 patients were conscious. There was no statistically significant difference between the two groups regarding the pain score associated with insertion. There were statistically significant differences between the two groups regarding the pain score associated with IO or CVC infusion(1.5 vs. 0.0, P=0.044). Complications were not observed in the two groups.CONCLUSIONS: IO access is a safe, rapid, and effective technique for gaining vascular access in critically ill adults with inaccessible peripheral veins in the emergency departments. 展开更多
关键词 Intraosseous access central venous catheterization Success rates Procedure time Pain score
下载PDF
Ultrasound-Guided Central Venous Catheterization: A Protocol to Be Followed in Pediatrics?
3
作者 Mayara Goncalves Marques Regina Grigolli Cesar 《Open Journal of Pediatrics》 2017年第3期128-139,共12页
Objective: To investigate the effectiveness of ultrasound-guided central venous catheterization when compared to the conventional procedure. Method: A prospective cohort study was carried out over a 9-month period fro... Objective: To investigate the effectiveness of ultrasound-guided central venous catheterization when compared to the conventional procedure. Method: A prospective cohort study was carried out over a 9-month period from February to October 2016 involving 144 inpatients at PICU of Irmandade da Santa Casa de Sao Paulo Hospital, undergoing central venous catheterization. The patients were matched in pairs of identical patients according to the levels of potentially intervening variables (age, nutritional status, puncture site, professional experience), differing only as to the CVC technique: ultrasound-guided (USG-CVC) or conventional (C-CVC). Discarding data from non-paired patients, the remaining did forming 47 pairs, matched as two related samples: USG-CVC and C-CVC groups. Success parameters: number of puncture attempts;time spent at CVC;success rate and complications. Results: In the USG-CVC group, the number of attempts (mean = 2.04) and the time spent at catheterization (mean = 11.89 minutes) were lower (t = 2.34, df = 46, t 0.95 = 2.02, p t = 3.07, df = 46, t 0.95 = 2.02, p < 0.05), respectively, when compared to the results obtained for the control group (C-GVC), (mean = 3.21) and (mean = 28.26 minutes), respectively. As to success, there was observed a significant difference (F (1, 46) = 16.6;Q (1) = 12.5, p < 005) when considering only one trial (USG -CVC = 27/47;C-CVC = 9/47), but no significant difference (F (1, 46) = 3.76;Q (1) = 3.56, p > 0.05) when considering several attempts. Complications were found less frequently in the USG-CVC group (3/47) than in the CVC-C (13/47), (F (1, 46) = 8.24;Q (1) = 7.14, p < 0.05). Conclusion: USG-CVC was found to be more effective than the conventional technique, especially regarding success at the first puncture attempt. 展开更多
关键词 central venous Catheters ULTRASONOGRAPHY central venous catheterization PEDIATRICS Pediatric Intensive Care Units Patient Safety
下载PDF
Current Research Progress of Central Venous Catheter-Associated Fibrin Sheath Prevention and Nursing Care
4
作者 Linzhi Xu Yue Li Hongjuan Wu 《Journal of Clinical and Nursing Research》 2024年第5期135-144,共10页
With the popularization of central venous catheterization in recent years,the problems arising from intravenous therapy have gradually increased.Fibrin sheath is the complication with the highest incidence rate in cen... With the popularization of central venous catheterization in recent years,the problems arising from intravenous therapy have gradually increased.Fibrin sheath is the complication with the highest incidence rate in central venous catheterization,which has always been a major problem in intravenous therapy.So the prevention and treatment of fibrin sheath has become a hot spot of research in recent years.Hence,this paper summarizes the research on fibrin sheath in recent years. 展开更多
关键词 central venous catheterization Fibrin sheath Clinical care
下载PDF
Clues for diagnosing misplaced central venous catheter in the right ascending lumbar vein during right femoral venous access
5
作者 Joho Tokumine Kiyoshi Moriyama Tomoko Yorozu 《World Journal of Clinical Cases》 SCIE 2024年第24期5473-5475,共3页
The right ascending lumbar vein is difficult to detect on anteroposterior abdominalradiographs because it overlaps with the inferior vena cava on anteroposteriorradiographs.Intensive observation by medical providers m... The right ascending lumbar vein is difficult to detect on anteroposterior abdominalradiographs because it overlaps with the inferior vena cava on anteroposteriorradiographs.Intensive observation by medical providers may be a cue fordiagnosis.However,knowledge of catheter misplacement of the right ascendinglumbar vein is also necessary,because misplacement cannot be suspected withoutthat awareness. 展开更多
关键词 central venous catheter Ascending lumbar vein Femoral vein Catheter misplacement Anteroposterior abdominal X-ray
下载PDF
Multiple paradoxical embolisms caused by central venous catheter thrombus passing through a patent foramen ovale: A case report
6
作者 Jian-Duan Li Nian Xu +2 位作者 Qiang Zhao Biao Li Li Li 《World Journal of Clinical Cases》 SCIE 2024年第4期842-846,共5页
BACKGROUND To date,this is the first case of a paradoxical embolism(PDE)that concurrently manifested in the coronary and lower limb arteries and was secondary to a central venous catheter(CVC)thrombus via a patent for... BACKGROUND To date,this is the first case of a paradoxical embolism(PDE)that concurrently manifested in the coronary and lower limb arteries and was secondary to a central venous catheter(CVC)thrombus via a patent foramen ovale(PFO).CASE SUMMARY Here,we report a case of simultaneous coronary and lower limb artery embolism in a PFO patient carrier of a CVC.The patient presented to the hospital with acute chest pain and lower limb fatigue.Doppler ultrasound showed a large thrombus in the right internal jugular vein,precisely at the tip of the CVC.Transthoracic and transesophageal echocardiography confirmed the existence of a PFO,with inducible right-to-left shunting by the Valsalva maneuver.The patient was administered an extended course of anticoagulation therapy,and then the CVC was successfully removed.Percutaneous PFO closure was not undertaken.There was no recurrence during follow-up.CONCLUSION Thus,CVC-associated thrombosis is a potential source for multiple PDE in PFO patients. 展开更多
关键词 Paradoxical embolism central venous catheter Patent foramen ovale Acute myocardial infarction Case report
下载PDF
Ultrasound based estimate of central venous pressure:Are we any closer?
7
作者 Atit A Gawalkar Akash Batta 《World Journal of Cardiology》 2024年第6期310-313,共4页
Central venous pressure(CVP)serves as a direct approximation of right atrial pressure and is influenced by factors like total blood volume,venous compliance,cardiac output,and orthostasis.Normal CVP falls within 8-12 ... Central venous pressure(CVP)serves as a direct approximation of right atrial pressure and is influenced by factors like total blood volume,venous compliance,cardiac output,and orthostasis.Normal CVP falls within 8-12 mmHg but varies with volume status and venous compliance.Monitoring and managing disturbances in CVP are vital in patients with circulatory shock or fluid disturbances.Elevated CVP can lead to fluid accumulation in the interstitial space,impairing venous return and reducing cardiac preload.While pulmonary artery catheterization and central venous catheter obtained measurements are considered to be more accurate,they carry risk of complications and their usage has not shown clinical improvement.Ultrasound-based assessment of the internal jugular vein(IJV)offers real-time,non-invasive measurement of static and dynamic parameters for estimating CVP.IJV parameters,including diameter and ratio,has demonstrated good correlation with CVP.Despite significant advancements in non-invasive CVP measurement,a reliable tool is yet to be found.Present methods can offer reasonable guidance in assessing CVP,provided their limitations are acknowledged. 展开更多
关键词 central venous pressure Internal jugular vein Point of care ultrasound Shock Volume status Fluid balance
下载PDF
Central venous catheterization-related complications in a cohort of 100 hospitalized patients:An observational study
8
作者 Reena Singh Naimish Patel +2 位作者 Nidhi Mehta Gaurav Singh Nirav Patel 《Journal of Acute Disease》 2023年第4期169-172,共4页
Objective:To evaluate the complications of central venous catheterization(CVC).Methods:A prospective,observational study was conducted at a tertiary care center in India from December 2018 to September 2020.Critically... Objective:To evaluate the complications of central venous catheterization(CVC).Methods:A prospective,observational study was conducted at a tertiary care center in India from December 2018 to September 2020.Critically ill patients(aged≥18 years)in the intensive care unit undergoing CVC procedures were included in the study.Baseline demographics and detailed medical history were recorded.Chest X-rays and electrocardiography were performed on all the patients.Complications associated with CVC were recorded.Results:A total of 100 patients with the indication for central venous catheter insertion were included.The majority(81%)of the patients were inserted with CVC at the right internal jugular vein.Complications such as arterial puncture(2%),hematoma(4%),blood clot formation(4%),catheter kinking(3%),thoracic injury(1%),thrombophlebitis(6%),sepsis(9%)and nerve injury(1%)were reported.Conclusions:Though central venous access is preferred in management of critically ill patients,it has its risks.However,early recognition and prompt management of complications may reduce mortality and morbidity.Physicians and intensive care unit intensivists should be vigilant for central venous catheter-related complications.Suitable site selection,operator experience,and proper catheter maintenance are associated with optimal outcomes. 展开更多
关键词 central venous catheter COMPLICATIONS central line central venous access Critical care Internal jugular vein
下载PDF
Impact of central venous port implantation method and access choice on outcomes 被引量:1
9
作者 Ayhan Erdemir Huseyin Kemal Rasa 《World Journal of Clinical Cases》 SCIE 2023年第1期116-126,共11页
BACKGROUND Although the number of patients who need central venous ports for permanent vascular access is increasing,there is still no“gold standard”for the implantation technique.AIM To identify the implantation te... BACKGROUND Although the number of patients who need central venous ports for permanent vascular access is increasing,there is still no“gold standard”for the implantation technique.AIM To identify the implantation technique that should be favored.METHODS Two hundred central venous port-implanted patients in a tertiary hospital were retrospectively evaluated.Patients were assigned into two groups according to the access method.The first group comprised patients whose jugular veins were used,and the second group comprised patients whose subclavian veins were used.Groups were evaluated regarding age,sex,application side,primary diagnosis,active follow-up period in the hospital,chemotherapy agents administered,number of complications,and the Clavien-Dindo severity score.The distribution of the variables was tested with the Kolmogorov-Smirnov test and the Mann-Whitney U test.Theχ^(2) test was used to analyze the variables.RESULTS There was no statistically significant difference between the groups regarding age,sex,side,number of chemotherapy drugs,and duration of port usage(P>0.05).Only 2 patients in group 1 had complications,whereas in group 2 we observed 19 patients with complications(P<0.05).No port occlusion was found in group 1,but the catheters of 4 patients were occluded in group 2.One port was infected in group 1 compared to three infected ports in group 2.Two port ruptures,two pneumothorax,one revision due to a mechanical problem,one tachyarrhythmia during implantation,and four suture line problems were also recorded in group 2 patients.We also showed that it would be sufficient to evaluate and wash ports once every 2 mo.CONCLUSION Our results robustly confirm that the jugular vein route is safer than the subclavian vein approach for central venous port implantation. 展开更多
关键词 Permanent vascular access central venous ports central venous port implantation methods Jugular vein route Subclavian vein approach Impact of implantation method on outcomes
下载PDF
Emphysematous thrombophlebitis caused by a misplaced central venous catheter: A case report
10
作者 Ni Chen Hua-Jun Chen +3 位作者 Tao Chen Wen Zhang Xiao-Yun Fu Zhou-Xiong Xing 《World Journal of Clinical Cases》 SCIE 2023年第29期7207-7213,共7页
BACKGROUND Central venous catheters(CVCs)often cause life-threatening complications,especially CVC-related bloodstream infection(CVC-BSI)and catheter-related thrombosis(CRT).Here,we report an unusual case of misplaced... BACKGROUND Central venous catheters(CVCs)often cause life-threatening complications,especially CVC-related bloodstream infection(CVC-BSI)and catheter-related thrombosis(CRT).Here,we report an unusual case of misplaced CVC-induced emphysematous thrombophlebitis,a rare but potentially lethal form of CRT and CVC-BSI characterized by both thrombosis and gas formation.CASE SUMMARY A 48-year-old male presented to the emergency room of a local hospital with sudden-onset headache and coma for 4 h.Computed tomography(CT)revealed right basal ganglia hemorrhage,so emergency decompressive craniotomy was performed and a CVC was inserted through the right subclavian vein for fluid resuscitation during anesthesia.Two days later,the patient was transferred to the intensive care unit of our hospital for further critical care.On day 9 after CVC insertion,the patient suddenly developed fever and hypotension.Point-of-care ultrasound(POCUS)demonstrated thrombosis and dilatation of the right internal jugular vein(IJV)filled with thrombosis.Ultrasonography also revealed that the CVC tip had been misplaced into the IJV and was surrounded by gas bubbles,which manifested as hyperechoic lines with dirty shadowing and comet-tail artifacts.Further CT scan confirmed air bubbles surrounding the CVC in the right neck.The final diagnosis was septic emphysematous thrombophlebitis induced by a misplaced CVC and ensuing septic shock.The responsible CVC was removed immediately.The patient received fluid resuscitation,intravenous noradrenaline,and a 10-d ultra-broad spectrum antibiotic treatment to combat septic shock.Both CVC and peripheral venous blood cultures yielded methicillin-resistant Staphylococcus cohnii.The patient was gradually weaned off vasopressors and the symptoms of redness and swelling in the right neck subsided within 7 d.CONCLUSION Emphysematous thrombophlebitis is a fulminant and life-threatening CVC-BSI associated with thrombosis and gas formation in the vein.A misplaced CVC may facilitate the development of emphysematous thrombophlebitis.POCUS can easily identify the artifacts produced by gas and thrombosis,facilitating rapid diagnosis at the bedside. 展开更多
关键词 Emphysematous thrombophlebitis Septic thrombophlebitis central venous catheter ULTRASOUND Catheter-related thrombosis central venous catheter-related bloodstream infection Case report
下载PDF
Accuracy of Mean Value of Central Venous Pressure from Monitor Digital Display: Influence of Amplitude of Central Venous Pressure during Respiration
11
作者 Meng-Ru Xu Wang-Lin Liu +4 位作者 Huai-Wu He Xiao-Li Lai Mei-Ling Zhao Da-Wei Liu Yun Long 《Chinese Medical Sciences Journal》 CAS CSCD 2023年第2期117-124,共8页
Background A simple measurement of central venous pressure(CVP)-mean by the digital monitor display has become increasingly popular.However,the agreement between CVP-mean and CVP-end(a standard method of CVP measureme... Background A simple measurement of central venous pressure(CVP)-mean by the digital monitor display has become increasingly popular.However,the agreement between CVP-mean and CVP-end(a standard method of CVP measurement by analyzing the waveform at end-expiration)is not well determined.This study was designed to identify the relationship between CVP-mean and CVP-end in critically ill patients and to introduce a new parameter of CVP amplitude(ΔCVP=CVPmax-CVPmin)during the respiratory period to identify the agreement/disagreement between CVP-mean and CVP-end.Methods In total,291 patients were included in the study.CVP-mean and CVP-end were obtained simultaneously from each patient.CVP measurement difference(|CVP-mean-CVP-end|)was defined as the difference between CVP-mean and CVP-end.TheΔCVP was calculated as the difference between the peak(CVPmax)and the nadir value(CVPmin)during the respiratory cycle,which was automatically recorded on the monitor screen.Subjects with|CVP-mean-CVP-end|≥2 mm Hg were divided into the inconsistent group,while subjects with|CVP-mean-CVP-end|2 mm Hg were divided into the consistent group.ResultsΔCVP was significantly higher in the inconsistent group[7.17(2.77)vs.5.24(2.18),P0.001]than that in the consistent group.There was a significantly positive relationship betweenΔCVP and|CVP-mean-CVP-end|(r=0.283,P 0.0001).Bland-Altman plot showed the bias was-0.61 mm Hg with a wide 95%limit of agreement(-3.34,2.10)of CVP-end and CVP-mean.The area under the receiver operating characteristic curves(AUC)ofΔCVP for predicting|CVP-mean-CVP-end|≥2 mm Hg was 0.709.With a high diagnostic specificity,usingΔCVP3 to detect|CVP-mean-CVP-end|lower than 2mm Hg(consistent measurement)resulted in a sensitivity of 22.37%and a specificity of 93.06%.UsingΔCVP8 to detect|CVP-mean-CVPend|8 mm Hg(inconsistent measurement)resulted in a sensitivity of 31.94%and a specificity of 91.32%.Conclusions CVP-end and CVP-mean have statistical discrepancies in specific clinical scenarios.ΔCVP during the respiratory period is related to the variation of the two CVP methods.A highΔCVP indicates a poor agreement between these two methods,whereas a lowΔCVP indicates a good agreement between these two methods. 展开更多
关键词 central venous pressure monitor digital display monitor cursor-line display RESPIRATION
下载PDF
Study on the Risk Factors of Central Venous-Related Bloodstream Infection in Outpatients
12
作者 Lu Yan Cuiyu Han +2 位作者 Xuerun Du Yujie Gu Rui Gao 《Journal of Clinical and Nursing Research》 2023年第4期120-125,共6页
Objective:To analyze the risk factors of catheter-related bloodstream infection in outpatients and propose feasible prevention and control measures.Methods:The medical records of outpatients with peripherally inserted... Objective:To analyze the risk factors of catheter-related bloodstream infection in outpatients and propose feasible prevention and control measures.Methods:The medical records of outpatients with peripherally inserted central catheter(PICC)from January 2020 to December 2021 were selected for retrospective analysis,and the factors that may be related to the occurrence of catheter-related bloodstream infection were analyzed by logistic multivariate analysis.Results:The incidence rate of catheter-related bloodstream infection among the enrolled patients was 4.78%.It was found that age,duration of catheterization,catheter site,number of punctures,and diabetes were all risk factors for catheter-associated bloodstream infection,and the differences were statistically significant.Conclusion:Age,duration of catheterization,catheterization site,and diabetes are all risk factors for catheter-related bloodstream infection,and medical personnel should fully understand and learn more about these risk factors and actively develop countermeasures to reduce the risk of catheter-related bloodstream infection. 展开更多
关键词 OUTPATIENT central venous catheter Bloodstream infection
下载PDF
Controlled low central venous pressure reduces blood loss and transfusion requirements in hepatectomy 被引量:61
13
作者 Zhi Li Yu-Ming Sun +3 位作者 Fei-Xiang Wu Li-Qun Yang Zhi-Jie Lu Wei-Feng Yu 《World Journal of Gastroenterology》 SCIE CAS 2014年第1期303-309,共7页
AIM: To evaluate the effect of low central venous pressure (LCVP) on blood loss and blood transfusion in patients undergoing hepatectomy.
关键词 Low central venous pressure HEPATECTOMY Blood loss Blood transfusion
下载PDF
Effect of controlled low central venous pressure on renal function in major liver resection 被引量:5
14
作者 Yuyong Liu Mingxue Cai Shan'e Duan Xuemei Peng Yong Lai Yalan Li 《The Chinese-German Journal of Clinical Oncology》 CAS 2008年第1期7-9,共3页
Objective: To investigate the effects of low central venous pressure (LVCP) on blood loss and evaluate its influence on renal function in patients undergoing hepatectomy. Methods: Forty-six patients, ASA classific... Objective: To investigate the effects of low central venous pressure (LVCP) on blood loss and evaluate its influence on renal function in patients undergoing hepatectomy. Methods: Forty-six patients, ASA classification Ⅰ-Ⅲ, undergoing liver resection were randomized into LCVP group (n = 23) and control group (n = 23). In LCVP group, CVP was maintained at 2-4 mmHg and MBP above 60 mmHg during hepatectomy, while in control group hepatectomy was performed routinely without lowering CVP. Volume of blood loss during hepatectomy, volume of blood transfusion, and changes of renal functions were compared between the two groups. Results: There were no significant differences in demographics, ASA score, type of hepatectomy, duration of inflow occlusion, operation time, weight of resected liver tissues, and renal functions between the two groups. LCVP group had a significantly lower volume of total intraoperative blood loss (P 〈 0.01) and RBC transfusion (P 〈 0.05). Conclusion: Lowering the CVP to less than 5 mmHg is a simple and effective technique to reduce blood loss and blood infusion during liver resection, and has no detrimental effects on renal functions. 展开更多
关键词 HEPATECTOMY hepatocellular carcinoma low central venous pressure blood loss renal function
下载PDF
Factors influencing the optimal selection of central venous access devices:A qualitative study of health care team members’perspectives 被引量:1
15
作者 Yuan Sheng Tinglan Wu +2 位作者 Chunmei Fan Haixia Hao Wei Gao 《International Journal of Nursing Sciences》 CSCD 2022年第4期445-452,共8页
Objective:This study aimed to explore health care team members’understanding of the factors influencing the optimal selection of central venous access devices(CVADs).Methods:The data of the study was collected using ... Objective:This study aimed to explore health care team members’understanding of the factors influencing the optimal selection of central venous access devices(CVADs).Methods:The data of the study was collected using semi-structured interviews.Twenty-six hospital medical staff(four hospital manager,15 head nurses,7 nurse)with experience in peripheral or central catheterization from four regions(Northern China,Southern China,Northwest China,and Qinghai-Tibet China)in China were interviewed between June and October 2021.Content analysis was used to analyze the data.Results:The results revealed five themes and 14 sub-themes.Patients:concerns,resources,requirements,and evaluation(security concerns,support resources,life requirements,evaluation among patients);nurses:awareness,knowledge,and popularizing methods(awareness of intravenous therapy,understanding of professional knowledge,forms of popularizing methods);doctors:support and involvement(support for decision-making,involvement in intravenous work);hospital managers:authority,quality control and continuing education(management of catheterization authority,quality control of intravenous infusion,investment in continuing education)and environment:differences and commonalities(differences in social support,and current commonalities).Conclusion:Nurses and other healthcare team members’understanding,selection,use,and recommendation of CVADs have an indirect effect on patients’decision-making.Therefore,hospital managers and government departments can indirectly strengthen medical team cooperation and improve learning education in order to improve the safety of patients receiving intravenous infusions. 展开更多
关键词 central venous catheterization China Hospital medical staff Qualitative research
下载PDF
Correlation of Inferior Vena Cava Respiratory Variability Index with Central Venous Pressure and Hemodynamic Parameters in Ventilated Pigs with Septic Shock 被引量:3
16
作者 LIU Xiao Lei TAO Yong Kang +5 位作者 YAN Sheng Tao QI Zhi Wei LU Hai Tao WANG Hai Feng GU Cheng Dong ZHANG Guo Qiang 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2013年第6期500-503,共4页
Septic shock is a common critical condition, for which effective early fluid resuscitation is the therapeutic focus. According to the 2008 international guidelines for management of severe sepsis and septic shock, res... Septic shock is a common critical condition, for which effective early fluid resuscitation is the therapeutic focus. According to the 2008 international guidelines for management of severe sepsis and septic shock, resuscitation should achieve a central venous pressure (CVP) of 8-12 mmHg within the first 6 h. However, it is still uncertain about the sensitivity and specificity of CVP in reflecting the cardiac preload. Ultrasonography is a simple, rapid, non-invasive, and repeatable method for the measurement of sensitivity and specificity of CVP and has thus gradually attracted the increasing attention of physicians. It was reported that ultrasonography can show the inferior vena cava diameter, respiratory variability index, and blood volume in patients with sepsis or heart failure. 展开更多
关键词 CVP SVV Correlation of Inferior Vena Cava Respiratory Variability Index with central venous Pressure and Hemodynamic Parameters in Ventilated Pigs with Septic Shock
下载PDF
Sonographic guidance for tunneled central venous catheters insertion in pediatric oncologic patients: guided punctures and guide wire localization
17
作者 Gehad T.Meselhy Kareem R.Sallam +3 位作者 Maged M.Elshafiey Amal Refaat Ahmad Samir Alaa A.Younes 《The Chinese-German Journal of Clinical Oncology》 CAS 2012年第8期484-490,共7页
Objective Totally implantable devices (TIDs) and external tunneled catheters (ETCs) became a basic requirement in the treatment of pediatric oncologic patients. Techniques for implantation and confirmation of proper ... Objective Totally implantable devices (TIDs) and external tunneled catheters (ETCs) became a basic requirement in the treatment of pediatric oncologic patients. Techniques for implantation and confirmation of proper position vary among different centers. The article presented different techniques for sonographic guided puncture of the target central vein and confirmation of the proper position of tunneled catheters. 展开更多
关键词 tunneled central venous catheters (tunneled CVCs) PEDIATRIC ultrasound
下载PDF
Clinical Course of Lung Cancer Patients with Subcutaneously Implanted Central Venous Access Device Ports from the Time of Receiving Chemotherapy to the Endpoint of Cancer
18
作者 Tomonori Hirashima Teppei Tsumori +11 位作者 Kenichi Sakai Makoto Fujishima Yukie Yamakawa Noriko Ryouta Masumi Sandoh Takayuki Shiroyama Motohiro Tamiya Naoko Morishita Hidekazu Suzuki Norio Okamoto Sho Goya Hironori Shigeoka 《Journal of Cancer Therapy》 2016年第7期519-529,共11页
Background: As the prognosis of lung cancer (LC) patients improves, subcutaneously implanted central venous access device ports (CV-ports) have frequently been used for continuing chemotherapy (CC) or palliative care ... Background: As the prognosis of lung cancer (LC) patients improves, subcutaneously implanted central venous access device ports (CV-ports) have frequently been used for continuing chemotherapy (CC) or palliative care (PC). In this study, we examined the clinical course of LC patients with subcutaneously implanted CV-ports from the time of receiving chemotherapy to the endpoint of cancer. Materials and Methods: We retrospectively reviewed the clinical data and treatment history of LC patients with subcutaneously implanted CV-ports between June 2008 and November 2013 using clinical records and a pharmacy database. Results: Of the 132 LC patients with subcutaneously implanted CV-ports, 79 (59.8%) had CV-ports for CC (the CC group) and 53 (40.2%) had CV-ports for PC (the PC group). After CV-port implantation, LC patients in the CC group received a median of two regimens with a median of 6 cycles. The median survival time of patients in the CC and PC groups was 457 and 44 days, respectively. In the CC group, the median survival time of small cell and non-small cell LC patients was 342 (95% confidence interval, 235 - 627) and 563 (95% confidence interval, 368 - 728) days, respectively. Nine patients (6.8%) had their CV-ports removed due to complications. Forty (30.3%) of the 132 enrolled patients were referred for at-home PC. The at-home death rate observed among these 40 patients was 30.0% (N = 12). Conclusion: CV-ports may contribute to seamless oncological care. 展开更多
关键词 Clinical Course At-Home Death Rate Implanted central venous Access Device Port Lung Cancer Seamless Oncological Care
下载PDF
A review in emergency central venous catheterization 被引量:6
19
作者 Osaree Akaraborworn 《Chinese Journal of Traumatology》 CAS CSCD 2017年第3期137-140,共4页
Central venous catheterization is widely used in the emergency setting. This review aims to assess central venous catheterization from the perspectives of types of catheters, sites of insertion, and tech- niques. In e... Central venous catheterization is widely used in the emergency setting. This review aims to assess central venous catheterization from the perspectives of types of catheters, sites of insertion, and tech- niques. In emergency conditions, non-tunneled catheters are preferred because the technique for its insertion is not complicated and less time-consuming. The size of catheter depends on the purpose of catheterization. For example, a large bore catheter is needed for rapid infusion. The ideal catheterization site should bear fewer thromboses, lower infectious rate, and fewer mechanical complications. Thus the femoral vein should be avoided due to a high rate of colonization and thrombosis while the subclavian vein seems to exhibit fewer infectious complications compared with other sites. The ultrasound-guided technique increases the success rate of insertion while decreases the mechanical complications rate, 展开更多
关键词 central venous catheters central catheterization Vascular access devices
原文传递
Optimal central venous pressure during partial hepatectomy for hepatocellular carcinoma 被引量:20
20
作者 Cheng-Xin Lin Ya Guo +4 位作者 Wan Yee Lau Guang-Ying Zhang Yi-Ting Huang Wen-Zheng He Eric CH Lai 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS 2013年第5期520-524,共5页
BACKGROUND:Low central venous pressure(CVP) affects hemodynamic stability and tissue perfusion.This prospective study aimed to evaluate the optimal CVP during partial hepatectomy for hepatocellular carcinoma(HCC).METH... BACKGROUND:Low central venous pressure(CVP) affects hemodynamic stability and tissue perfusion.This prospective study aimed to evaluate the optimal CVP during partial hepatectomy for hepatocellular carcinoma(HCC).METHODS:Ninety-seven patients who underwent partial hepatectomy for HCC had their CVP controlled at a level of 0 to 5 mmHg during hepatic parenchymal transection.The systolic blood pressure(SBP) was maintained,if possible,at 90 mmHg or higher.Hepatitis B surface antigen was positive in 90 patients(92.8%) and cirrhosis in 84 patients(86.6%).Pringle maneuver was used routinely in these patients with clamp/unclamp cycles of 15/5 minutes.The average clamp time was 21.4±8.0 minutes.These patients were divided into 5 groups based on the CVP:group A:0-1 mmHg;B:1.1-2 mmHg;C:2.1-3 mmHg;D:3.1-4 mmHg and E:4.1-5 mmHg.The blood loss per transection area during hepatic parenchymal transection and the arterial blood gas before and after liver transection were analyzed.RESULTS:With active fluid load,a constant SBP ≥90 mmHg which was considered as optimal was maintained in 18.6% in group A(95% CI:10.8%-26.3%);39.2% in group B(95% CI:29.5%-48.9%);72.2% in group C(95% CI:63.2%-81.1%);89.7% in group D(95% CI:83.6%-95.7%);and 100% in group E(95% CI:100%-100%).The blood loss per transection area during hepatic parenchymal transection decreased with a decrease in CVP.Compared to groups D and E,blood loss in groups A,B and C was significantly less(analysis of variance test,P【0.05).Compared with the baseline,the blood oxygenation decreased significantly when the CVP was reduced.Base excess and HCO 3-in groups A and B were significantly decreased compared with those in groups C,D and E(P【0.05).CONCLUSION:In consideration of blood loss,SBP,base excess and HCO 3-,a CVP of 2.1-3 mmHg was optimal in patients undergoing partial hepatectomy for HCC. 展开更多
关键词 central venous pressure HEPATECTOMY blood loss
下载PDF
上一页 1 2 230 下一页 到第
使用帮助 返回顶部