The GECAM series of satellites utilizes LaBr_(3)(Ce),LaBr_(3)(Ce,Sr),and NaI(Tl)crystals as sensitive materials for gamma-ray detectors(GRDs).To investigate the nonlinearity in the detection of low-energy gamma rays a...The GECAM series of satellites utilizes LaBr_(3)(Ce),LaBr_(3)(Ce,Sr),and NaI(Tl)crystals as sensitive materials for gamma-ray detectors(GRDs).To investigate the nonlinearity in the detection of low-energy gamma rays and address the errors in the calibration of the E-C relationship,comprehensive tests and comparative studies of the three aforementioned crystals were conducted using Compton electrons,radioactive sources,and mono-energetic X-rays.The nonlinearity test results of the Compton electrons and X-rays demonstrated substantial differences,with all three crystals presenting a higher nonlinearity for X/-rays than for Compton electrons.Despite the LaBr_(3)(Ce)and LaBr_(3)(Ce,Sr)crystals having higher absolute light yields,they exhibited a noticeable nonlinear decrease in the light yield,especially at energies below 400 keV.The NaI(Tl)crystal demonstrated an"excess"light output in the 6-200 keV range,reaching a maximum"excess"of 9.2%at 30 keV in the X-ray testing and up to 15.5%at 14 keV during Compton electron testing,indicating a significant advantage in the detection of low-energy gamma rays.Furthermore,we explored the underlying causes of the observed nonlinearity in these crystals.This study not only elucidates the detector responses of GECAM,but also initiates a comprehensive investigation of the nonlinearity of domestically produced lanthanum bromide and sodium iodide crystals.展开更多
A scintillator detector consisting of a LaBr_(3)(Ce)(0.5%)scintillator,a photomultiplier tube(PMT),and an oscilloscope were used to study the neutron sensitivities of the LaBr_(3)(Ce)scintillator at the China Spallati...A scintillator detector consisting of a LaBr_(3)(Ce)(0.5%)scintillator,a photomultiplier tube(PMT),and an oscilloscope were used to study the neutron sensitivities of the LaBr_(3)(Ce)scintillator at the China Spallation Neutron Source(CSNS)Back-n white neutron source in the double-bunch and single-bunch operation modes,respectively.Under the two operational modes,the relative neutron sensitivity curves of the LaBr_(3)(Ce)scintillator in the energy regions of 1–20 MeV and 0.5–20 MeV were obtained for the first time.In the energy range of 1–20 MeV,the two curves were nearly identical.However the relative neutron sensitivity uncertainties of the double-bunch experiment were higher than those of the single-bunch experiment.The above results indicated that the single-bunch experiment's neutron sensitivity curve has a lower minimum measurable energy than the double-bunch experiment.Above the minimum measurable energy of the double-bunch experiment,there is little difference between the measured relative neutron sensitivity curves of the single-bunch and double-bunch experiments of the LaBr_(3)(Ce)scintillator and those of other scintillators with a similar neutron response signal intensity.展开更多
基金This work was supported by the National Key Research and Development Program(Nos.2022YFB3503600 and 2021YFA0718500)Strategic Priority Research Program of the Chinese Academy of Sciences(Nos.XDA15360102)National Natural Science Foundation of China(Nos.12273042 and 12075258).
文摘The GECAM series of satellites utilizes LaBr_(3)(Ce),LaBr_(3)(Ce,Sr),and NaI(Tl)crystals as sensitive materials for gamma-ray detectors(GRDs).To investigate the nonlinearity in the detection of low-energy gamma rays and address the errors in the calibration of the E-C relationship,comprehensive tests and comparative studies of the three aforementioned crystals were conducted using Compton electrons,radioactive sources,and mono-energetic X-rays.The nonlinearity test results of the Compton electrons and X-rays demonstrated substantial differences,with all three crystals presenting a higher nonlinearity for X/-rays than for Compton electrons.Despite the LaBr_(3)(Ce)and LaBr_(3)(Ce,Sr)crystals having higher absolute light yields,they exhibited a noticeable nonlinear decrease in the light yield,especially at energies below 400 keV.The NaI(Tl)crystal demonstrated an"excess"light output in the 6-200 keV range,reaching a maximum"excess"of 9.2%at 30 keV in the X-ray testing and up to 15.5%at 14 keV during Compton electron testing,indicating a significant advantage in the detection of low-energy gamma rays.Furthermore,we explored the underlying causes of the observed nonlinearity in these crystals.This study not only elucidates the detector responses of GECAM,but also initiates a comprehensive investigation of the nonlinearity of domestically produced lanthanum bromide and sodium iodide crystals.
基金Project supported by the National Natural Science Foundation of China(Grant No.11905196)。
文摘A scintillator detector consisting of a LaBr_(3)(Ce)(0.5%)scintillator,a photomultiplier tube(PMT),and an oscilloscope were used to study the neutron sensitivities of the LaBr_(3)(Ce)scintillator at the China Spallation Neutron Source(CSNS)Back-n white neutron source in the double-bunch and single-bunch operation modes,respectively.Under the two operational modes,the relative neutron sensitivity curves of the LaBr_(3)(Ce)scintillator in the energy regions of 1–20 MeV and 0.5–20 MeV were obtained for the first time.In the energy range of 1–20 MeV,the two curves were nearly identical.However the relative neutron sensitivity uncertainties of the double-bunch experiment were higher than those of the single-bunch experiment.The above results indicated that the single-bunch experiment's neutron sensitivity curve has a lower minimum measurable energy than the double-bunch experiment.Above the minimum measurable energy of the double-bunch experiment,there is little difference between the measured relative neutron sensitivity curves of the single-bunch and double-bunch experiments of the LaBr_(3)(Ce)scintillator and those of other scintillators with a similar neutron response signal intensity.