期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Development of a certified reference material for visual inspection of unsound maize kernels
1
作者 Zhang Huijie Li Jingmei +9 位作者 Wu Li Li Weixi Sun Lijuan Zhang Yan Zhao Hongxiang Hu Xuexu Jin Longguo Du Wenming Wang Bujun Fu Jindong 《China Standardization》 2022年第6期63-68,共6页
Maize unsound kernel content is one of the limited items in maize trade, and generally determined by sensory detection. A certified reference material(CRM) for visual inspection of maize unsound kernels was developed ... Maize unsound kernel content is one of the limited items in maize trade, and generally determined by sensory detection. A certified reference material(CRM) for visual inspection of maize unsound kernels was developed according to a national standard of China, GB 1353-2018, and five items, such as insect-damaged kernels, spotted kernels, broken kernels, sprouted kernels and moldy kernels, were included. Unsound maize kernels were collected from fields or prepared in a laboratory, then screened, and ten kernels demonstrating varying levels of unsoundness or damage for each item were embedded in epoxy resin. The CRM showed excellent homogeneity and stability, which was stable for 14 days at the temperature from-20℃ to 45℃ and for at least 18 months at room temperature out of direct sunlight and strong light. Co-laboratory confirmation showed the CRM conformed to the morphological characteristics described in GB 1353-2018. The research filled the gap of unsound maize kernel CRM in maize detection. 展开更多
关键词 maize unsound kernels certified reference material(CRM) visual inspection
下载PDF
Determination of Hf–Sr–Nd isotopic ratios by MC-ICP-MS using rapid acid digestion after flux-free fusion in geological materials 被引量:4
2
作者 Zhian Bao Chunlei Zong +3 位作者 Linru Fang Honglin Yuan Kaiyun Chen Mengning Dai 《Acta Geochimica》 EI CAS CSCD 2018年第2期244-256,共13页
In this study, we established a rapid acid digestion for determining Hf-Sr-Nd isotopic ratios of geological samples by using MC-ICP-MS. Conditions of 1600 ℃ for 1 min and 1400 ℃ for 1 min were adopted for fusing int... In this study, we established a rapid acid digestion for determining Hf-Sr-Nd isotopic ratios of geological samples by using MC-ICP-MS. Conditions of 1600 ℃ for 1 min and 1400 ℃ for 1 min were adopted for fusing intrusive rocks and extrusive rocks, respectively. The rapid acid digestion technique is superior in digestion time compared with high-pressure PTFE bomb method. The procedural blanks of the method were also lower than that flux fusion. Replicate analyses of international certified reference materials (CRMs) indicate that isotopic ratios of ^176Hf/^177Hf, ^87Sr/^86Sr and 143Nd/144Nd agree well with previously published data. The external reproducibility (2SD, n = 5) of ten CRMs are ±0.000030 for ^87Sr/^86Sr, ± 0.000030 for ^143Nd/^144Nd, and ±0.000018 for ^176Hf/^177Hf. 展开更多
关键词 certified reference material Flux-free fusion Hf-Sr-Nd isotopic ratio Procedural blank Rapid acid digestion
下载PDF
Preparation and Certification of a New Salvianolic Acid A Reference Material for Food and Drug Research 被引量:1
3
作者 Dezhi Yang Bin Su +5 位作者 Yancai Bi Li Zhang Baoxi Zhang Junke Song Yang Lu Guanhua Du 《Natural Products and Bioprospecting》 CAS 2020年第2期67-75,共9页
Salvianolic acid A(Sal A),a water-soluble ingredient in Danshen,has various biological activities.Sal A and its impurities have similar physical and chemical properties,as well as strong reducibility;therefore,they ar... Salvianolic acid A(Sal A),a water-soluble ingredient in Danshen,has various biological activities.Sal A and its impurities have similar physical and chemical properties,as well as strong reducibility;therefore,they are difficult to prepare and purify.In this study,high-purity Sal A was obtained by purification of sephadex chromatography and preparative chromatography.Furthermore,HPLC-DAD tandem ECD and HPLC-DAD tandem MS methods were used for non-volatile organic impurity analysis,ICP-MS method was used for non-volatile inorganic impurities and mass balance method and quantitative nuclear magnetic resonance were employed to certify the product.The structures of Sal A and its relative impurities were validated by nuclear magnetic resonance spectroscopy and mass spectrometry,and their contents were quantified as well.Following the principles of ISO Guides 34:2009 and 35:2005,a Sal A reference material was certified,covering homogeneity studies,stability studies,characterization,and uncertainty estimations. 展开更多
关键词 certified reference material Salvianolic acid A Mass balance method qNMR High resolution mass spectrum
下载PDF
Development of a new ferulic acid certified reference material for use in clinical chemistry and pharmaceutical analysis 被引量:4
4
作者 Dezhi Yang Fengfeng Wang +2 位作者 Li Zhang Ningbo Gong Yang Lv 《Acta Pharmaceutica Sinica B》 SCIE CAS CSCD 2015年第3期231-237,共7页
This study compares the results of three certified methods, namely differential scanning calorimetry (DSC), the mass balance (MB) method and coulometric titrimetry (CT), in the purity assessment of ferulic acid certif... This study compares the results of three certified methods, namely differential scanning calorimetry (DSC), the mass balance (MB) method and coulometric titrimetry (CT), in the purity assessment of ferulic acid certified reference material (CRM). Purity and expanded uncertainty as determined by the three methods were respectively 99.81%, 0.16%; 99.797, 0.16%; and 99.81%, 0.26% with, in all cases, a coverage factor (k) of 2 (P=95%). The purity results are consistent indicating that the combination of DSC, the MB method and CT provides a confident assessment of the purity of suitable CRMs like ferulic acid. (C) 2015 Chinese Pharmaceutical Association and Institute of Materia Medica, Chinese Academy of Medical Sciences. Production and hosting by Elsevier B.V. 展开更多
关键词 Differential scanning calorimetry Mass blance Coulometric titrimetry certified reference material Uncertainty ferulic acid
原文传递
Theoretical and experimental assessment of a novel method to establish the complete measurement range of the calorimeter and its limit of detection and quantification
5
作者 Vesna Krstic 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2022年第4期466-473,共8页
For determining the accuracy of a calorimeter over the instrument’s entire measuring range,a novel method has been established.For this new approach,(a)benzoic acid(C_(6)H_(5)CO_(2)H) as a certified reference materia... For determining the accuracy of a calorimeter over the instrument’s entire measuring range,a novel method has been established.For this new approach,(a)benzoic acid(C_(6)H_(5)CO_(2)H) as a certified reference material(CRM),(b)SiO_(2) and(c)a mixture of CRM benzoic acid and SiO_(2) have been used.To illustrate the essential difference between 1)the novel analytical method for control of the entire measurement range and 2)the calorimeter calibration,both applications of benzoic acid(BA)have been demonstrated.An experimental result showed that BA was successfully used to check the whole calorimeter measurement range.The results also showed that the same new method was successfully applied to determine the limit of detection and quantification.A new instrument testing process and a new measurement technique have thus been established.In this way,the cost of using CRM to control the accuracy of measuring the entire measuring range of the calorimeter,as shown in this paper,is minimized.The requirements of the ISO/IEC 17025:2017 standard are satisfied.ISO/IEC 17025:2017,together with ISO 9001:2015(quality management systems),ISO 14001:2015(relate to environmental protection)and ISO45001:2018(occupational safety),constitute an integrated quality system by which a testing laboratory may also accredit. 展开更多
关键词 Benzoic acid certified reference material The limit of detection/quantification Measurement range Quality control CALORIMETER Environmental protection
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部