In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Sc...In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Scientific C18 column (250 mm×4.6 mm, 5 μm) as the chromatographic column and acetonitrile and water as the mobile phase, and the excitation wavelength and emission wavelength of fluorescence detector were 286 and 430 nm, respectively. The response was high, and the linear range was 0.5-10.0 ng/ml. The lowest limit of detection was 0.11 ng/ml, and the average recovery was 92.5%. This method is suitable for quantitative analysis of benzo[a]pyrene content in edible oil.展开更多
A rapid, fast and precise method has been developed and validated for the simultaneous determination of amlodipine with H1-receptor antagonists (cetirizine, fexofenadine, and buclizine) from dosage forms. The chromato...A rapid, fast and precise method has been developed and validated for the simultaneous determination of amlodipine with H1-receptor antagonists (cetirizine, fexofenadine, and buclizine) from dosage forms. The chromatography was performed on a Purospher? Star, C18 (5 mm, 250 × 4.6 mm) column using acetonitrile: buffer (0.01 mM) (40:60, v/v, pH adjusted to 3.0), as a mobile phase. The mobile phase was pumped at a flow rate of 1.0 mL·min-1 and UV detection was performed at 240 nm. The method was validated for linearity, accuracy, precision and specificity. The method was applied to study the interaction between amlodipine and H1-receptor antagonists. These interactions were carried out in simulated gastric juice (pH 1), simulated full stomach (pH 4), blood pH (pH 7.4) and simulating GI (pH 9). The interacting drugs were heated at 37℃ with intermit-tent shaking and the samples were withdrawn every thirty minutes for three hours and drug contents were analyzed by RP-HPLC techniques. In most cases the in vitro availability of amlodipine was decreased. It was observed that the change in in vitro availability was pH dependent.展开更多
Modification was made on the reversed-phase high performance liquidchromatography(RP-HPLC)with Yue et al’s method as a base.The modified RP-HPLCwas used to detect leukotriene B<sub>4</sub>(LTB<sub&g...Modification was made on the reversed-phase high performance liquidchromatography(RP-HPLC)with Yue et al’s method as a base.The modified RP-HPLCwas used to detect leukotriene B<sub>4</sub>(LTB<sub>4</sub>)and 5-hydroxyeicosatetraenoic acid(5-HETE).Itwas found that the modified method has the merits of simpler procedures,shortertesting time and more satisfactory efficacy.展开更多
Objective High performance liquid chromatography(HPLC)and liquid chromatography-mass spectrometry(LC/MS)methods were developed for the determination of ganciclovir and its related substances.Methods A Hypersil ODS2 co...Objective High performance liquid chromatography(HPLC)and liquid chromatography-mass spectrometry(LC/MS)methods were developed for the determination of ganciclovir and its related substances.Methods A Hypersil ODS2 column(4.6 mm×250 mm,5 μm)was used with a mobile phase of 0.02 M potassium dihydrogen phosphate buffer(pH 6.0)-methanol(92∶8)at a flow rate of 1.0 mL/min,and UV detector set at 254 nm was used for monitoring the eluents.Results The method was simple,rapid,selective and capable of separating all related substances at trace level with a detection limit of 0.04 μg/mL.It has been validated with respect to accuracy,precision,linearity,and limits of detection and quantification.The linearity range was 10.2-153.0 μg/mL with r=0.9998.The percentage recoveries ranged from 96.7% to 101.6%,and RSD was 1.24%-1.96%(n=5).Conclusion The method was found to be suitable not only for monitoring the reactions during the process development but also for quality control of ganciclovir.For identification of related substances,LC/MS was used.The mainly related substances of ganciclovir active pharmaceutical ingredients(API)were determined as guanine,(1,3-dioxolan-4-yl)methyl acetate,and diacetyl guanine.展开更多
An efficient preparative method was successfully developed for isolation and purification of unstable components from medicinal plant extracts, using a combined method of preparative high performance liquid chro-matog...An efficient preparative method was successfully developed for isolation and purification of unstable components from medicinal plant extracts, using a combined method of preparative high performance liquid chro-matography(HPLC) and solid-phase extraction(SPE). The aim of this study was to obtain an effective method with high preparative efficiency and importantly to avoid the transformation of unstable compounds. The preparative HPLC system was based on an LC/MS controlled four-channel autopurification system. The SPE method was performed with a C18 packing material to trap the target compounds and to remove the acidic additive derived from the mobile phase. Using this method, the unstable iridoid glucosides(IGs) as model compounds were successfully isolated and purified from the extract of Hedyotis diffusa Willd. Six IGs(including one new minor IG) and one nucleotide compound were simultaneously obtained, each with a purity of 91% as determined by HPLC. The structures of the isolated compounds were identified by UPLC/Q-TOF MS, UV, 1D and/or 2D NMR. It was demonstrated that the combination of preparative HPLC with SPE is a versatile tool for preparative purification of unstable compounds from complex natural products.展开更多
[Objective] To develop a solid phase extraction-high performance liquid chromatography-fluorescence method for determination of quin- olone antibiotics in water. [ Metbod] The standard curves of four quinolones (norf...[Objective] To develop a solid phase extraction-high performance liquid chromatography-fluorescence method for determination of quin- olone antibiotics in water. [ Metbod] The standard curves of four quinolones (norfloxacin, ciprofloxacin, Iomefloxacin and enrofloxacin) were pre- pared. The detection limit in water and recovery were determined. The water samples collected from different areas, river and tap water were trea- ted using solid-phese extraction method and analyzed by high performance liquid chromatography. Then the concentration of quinolones antibiotics was determined by fluorescence method. [ Result] The detection limit of quinolone antibiotics in water was 0.083 -0.248 μg/L, and their recovery was 63.7% -134.1%. The four quinolone antibiotics at different levels were detected in various water samples, and the total concentration of quin- olone antibiotics was 0.045 -3.969 μg/L. The total concentration of quinolone antibiotics was higher in the water samples collected from rivers in Shenzhen area than in the sewage samples. The four quinolone antibiotics could be detected in all tap water samples. [ CoaduLsion ] The solid phase extraction-high performance liquid chromatography-fluorescence method is feasible and effective to detect quinolones in water. In addition, this method needs low cost and can meet requirements of daily monitorina and analysis.展开更多
A new type of HPLC stationary phase containing thymine derivative was successfully prepared.It was found to give selective separation of nucleic acid bases and several purine derivatives,such as caffeine and theophyll...A new type of HPLC stationary phase containing thymine derivative was successfully prepared.It was found to give selective separation of nucleic acid bases and several purine derivatives,such as caffeine and theophylline.The retention behaviour and elution order of the solutes were interpreted in terms of molecular structure.展开更多
A low cost,rapid and sensitive preparation method of silica gel supported ionic liquid(SGSIL)combined with matrix solid phase dispersion(MSPD)followed by high performance liquid chromatography(HPLC)with ultraviolet de...A low cost,rapid and sensitive preparation method of silica gel supported ionic liquid(SGSIL)combined with matrix solid phase dispersion(MSPD)followed by high performance liquid chromatography(HPLC)with ultraviolet detection(UV)is proposed,and it was applied to determine the seven active compounds in Salvia Miltiorrhiza herb.SGSIL and ionic liquid[BMIM]BF4 were used as the adsorbent and the green elution reagent in the MSPD procedure.Several extraction conditions including type of filler and elution solvent,the volume of elution solvent,material liquid ratio were optimized.Under the optimum conditions,the SGSIL-MSPD-HPLC method showed a low limit of detection(LOD,S/N=3)of 0.0122-0.8788μg/mL for standard solution,limit of quantification(LOQ,S/N=10)of 0.0406-2.9292μg/mL for standard solution,wide linear range from 1.56 to 2000μg/mL for all compounds for standard solution,correlation coefficients(r)of more than 0.9990,acceptable reproducibility(relative standard deviations,RSDs<3.54%),and precision of RSDs<3.36%for intra-day,RSDs<3.50%for inter-day.The satisfactory recoveries ranged from 96.4 to 102.5,with RSDs less than 3.45%.The developed SGSIL-MSPD method is easier and more suitable for the determination of the seven active compounds in Salvia Miltiorrhiza herb than the traditional ultrasonic extraction.It was an effective and efficient method for the extraction and quantification of the seven active compounds in traditional Chinese herbal samples.展开更多
The chiral separation of phenylsuccinic acid(PSA)was studied by reversed phase high-performance liquid chromatography(RP-HPLC)with cyclodextrins(CDs)as chiral mobile phase additives.The effects of types of CDs,concent...The chiral separation of phenylsuccinic acid(PSA)was studied by reversed phase high-performance liquid chromatography(RP-HPLC)with cyclodextrins(CDs)as chiral mobile phase additives.The effects of types of CDs,concentration of hydroxypropyl-β-cyclodextrin(HP-β-CD),percentage of organic modifier,pH value and column temperature on enantioselective separation were investigated.The quantification property of the developed RP-HPLC method was examined.The chiral recognition mechanism of PSA was also discussed.The results show that a baseline separation of PSA enantiomers is achieved on a Lichrospher C18 column(4.6 mm(inner diameter)×250 mm,5μm)with HP-β-CD as chiral mobile phase additive.The capacity factors of R-PSA and S-PSA are 3.94 and 4.80,respectively.The separation factor and resolution are respectively 1.22 and 8.03.The mobile phase is a mixture of acetonitrile and deionized water(20-80,volume ratio)containing 10 mmol/L HP-β-CD and 0.05% trifluoroacetic acid(pH 2.5,adjusted with triethylamine)with a flow rate of 1.0 mL/min.The ultraviolet(UV)detector is set at 254 nm.The likely roles are inclusion interaction,induction and hydrogen bonding between HP-β-CD and PSA enantiomers.展开更多
A simple, precise, accurate and sensitive reverse phase high performance liquid chromatographic method for simultaneous estimation of lisinopril dihydrate and its degradation products occuring under different ICH pres...A simple, precise, accurate and sensitive reverse phase high performance liquid chromatographic method for simultaneous estimation of lisinopril dihydrate and its degradation products occuring under different ICH prescribed stress conditions has been modified. Drug was resolved on a C18 column, utilizing modified mobile phase of tetra butyl ammonium hydroxide solution and acetonitrile. Ultra violet detection was carried out at 210 nm. The method was modified with respect to linearity, precision, accuracy, selectivity, specificity and ruggedness. The results obtained revealed that lisinopril dihydrate was an active product slightly changed under stress conditions.展开更多
A novel method for the determination of five carbamate pesticides (metolcarb, carbofuran, carbaryl, isoprocard and diethofencard) in water samples was developed by dispersive liquid-liquid microextraction (DLLME) ...A novel method for the determination of five carbamate pesticides (metolcarb, carbofuran, carbaryl, isoprocard and diethofencard) in water samples was developed by dispersive liquid-liquid microextraction (DLLME) coupled with high performance liquid chromatography-diode array detector (HPLC-DAD). Some experimental parameters that influence the extraction efficiency were studied and optimized to obtain the best extraction results. Under the optimum conditions for the method, the calibration curve was linear in the concentration range from 5 to 1000 ng mL^-1 for all the five carbamate pesticides, with the correlation coefficients (r^2) varying from 0.9984 to 0.9994. Good enrichment factors were achieved ranging from 80 to 177- fold, depending on the compound. The limits of detection (LODs) (S/N = 3) were ranged from 0.1 to 0.5 ng mL^-1. The method has been successfully applied to the analysis of the pesticide residues in environmental water samples.展开更多
HPLC method for analysis of the flavonoids from ginkgo biloba extract (GBE) was studied. By suitable selection of columns. symmetrical chromatographic peaks were obtained without using acidic modifier in the mobile ph...HPLC method for analysis of the flavonoids from ginkgo biloba extract (GBE) was studied. By suitable selection of columns. symmetrical chromatographic peaks were obtained without using acidic modifier in the mobile phase, which can eliminate the time for cleaning the chromatographic system and simplify the analystic method for GBE Experimental conditions: column: Hypersil BDS C-18, 5mumx4x250 mm: column temperature: 35degreesC; mobile phase: 46% methanol-54% water; flow rate: 0.7 mL/min; detection wavelength: 360nm.展开更多
The most suitable bio-analytical method based on liquid liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard fo...The most suitable bio-analytical method based on liquid liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard for Rasagiline. Zorbax Eclipse Plus C18 (2.1 mm × 50 mm, 3.5 um) column provided chromatographic separation of analyte followed by detection with mass spectrometry. The method involved simple isocratic chromatographic condition and mass spectrometric detection in the positive ionization mode using an API-4000 system. The lotal run time was 3.0 min. The proposed method has been validated with the linear range of 5 12000 pg/mL for Rasagiline. The intra-run and inter-run precision values were within 1.3% 2.9% and 1.6% 2.2% respectively for Rasagiline. The overall recovery for Rasagiline and Rasagiline-13C3 mesylate analog was 96.9% and 96.7% respectively. This validated method was successfully applied to the bioequivalence and pharmacokinetic study of human volunteers under fasting condition.展开更多
Objective: To develop the representative fingerprint for the quality control of placenta polypeptide injection. Methods: The chromatographic separation was performed using a Phenomenex Gemini C18 column (250 mm 4.6 mm...Objective: To develop the representative fingerprint for the quality control of placenta polypeptide injection. Methods: The chromatographic separation was performed using a Phenomenex Gemini C18 column (250 mm 4.6 mm, 5 mm) maintained at 30 1C. 0.1% aqueous trifiuoroacetic acid (Solvent A) and acetonitrile contained 0.1% TFA (Solvent B) were used as mobile phase with a gradient elution. Detection wavelength was 280 nm with the sample injection volume of 50 mL; the fiow rate was 1.0 mL/min. The fingerprints of different samples were investigated by similarity analysis. Results: Nine peaks were identified as the characteristic common peaks. The similarities of the fingerprints of the 10 batches of samples were above 0.992. Conclusion: This method showed high precision and good repeatability, and provided the basis for the improvement of the quality control of placenta polypeptide injection.展开更多
Seven polycyclic aromatic hydrocarbons (PAHs) in atmospheric particulates were determinated by high performance liquid chromatography (HPLC) with fluorescence detector using direction injection and an on-line enri...Seven polycyclic aromatic hydrocarbons (PAHs) in atmospheric particulates were determinated by high performance liquid chromatography (HPLC) with fluorescence detector using direction injection and an on-line enrichment trap column. The method simplified the sample pretreatment, saved time and increased the efficiency. With the on-line trap column, PAHs were separated availably even underground injecting 1.0 ml sample with relatively high column efficiency. The recoveries of the seven PAHs were from 85% to 120% for spiked atmospheric particulate sample. The limit of detection was 15.3-39.6 ng/L (S/N=3.3). There were good linear correlations between the peak areas and concentrations of the seven kinds of PAHs in the range of 1-50 ng/ml with the correlation coefficients over 0.9970. Furthermore, it also indicated that the method is available to determine PAHs in atmospheric particulates well.展开更多
To determine dopamine and its metabolites during in vivo cerebral microdialysis by routine high performance liquid chromatography with electrochemical detection. Methods Microdialysis probes were placed into the right...To determine dopamine and its metabolites during in vivo cerebral microdialysis by routine high performance liquid chromatography with electrochemical detection. Methods Microdialysis probes were placed into the right striatum of Wistar rat brains and perfused with Ringer's solution at a rate of 1.5 pL/min. A reverse phase HPLC with electrochemistry was used to assay DA, DOPAC, and HVA after cerebral microdialysates were collected every 20 minutes from awake and freely moving rats. In order to identify the reliability of this method, its selectivity, linear range, precision and accuracy were tested and the contents of DA, DOPAC, and HVA in rat microdialysates were determined. Results The standard curve was in good linear at the concentration ranging from 74 nmol/L to 1.5 pmol/L for DOPAC (r^2= 0.9996), from 66 nmol/L to 1.3 gmol/L for DA (r^2=l.0000) and from 69 nmol/L to 1.4 pmol/L for HVA (r^2=0.9992). The recovery of DOPAC (0.30, 0.77, 1.49 gmol/L), DA (0,26, 0.69, 1.32 gmol/L), and HVA (0.27, 0.71, 1.37 gmol/L) was 82.00±1.70%, 104.00±4.00%, 98.70±3.10%; 92.30± 1.50%, 105.30±2.30%, 108.00±2.00%; 80.00±7.80%, 107.69±8.00%, and 108.66±3.10%, respectively at each concentration. Their intra-day RSD was 3.3%, 3.4%, and 2.5%, and inter-day RSD was 4.2%, 2.3%, and 5.6%, respectively. The mean extracellular concentrations of DOPAC, DA, and HVA in rat brain microdialysates were 10.7, 2.4, and 9.2 gmol/L (n=6), respectively. Conclusion The findings of our study suggested that the simple, accurate and stable method can be applied to basic researches of diseases related to monoamines neurotransmitters by cerebral microdialysis in rats.展开更多
[Objective]The paper was to establish a method for determining AF and AFG in red ginseng.[Method]A new simple,rapid and sensitive method for simultaneous determination of two amadori compounds,arginyl-fructose(AF)and ...[Objective]The paper was to establish a method for determining AF and AFG in red ginseng.[Method]A new simple,rapid and sensitive method for simultaneous determination of two amadori compounds,arginyl-fructose(AF)and arginyl-fructosyl-glucose(AFG),in extracts of three kinds of ginseng preparations was developed and validated using high performance liquid chromatography with evaporative light scattering detector(HPLC-ELSD).Two target analytes were efficiently separated by Prevail CTM18 column(4.6 mm×250 mm,5μm)at the flow rate of 0.8 mL/min within 15 min of single chromatographic run.[Result]Under optimized conditions,the detection limits were 0.015 and 0.02 mg/mL for AF and AFG,respectively.Calibration curves of peak area for two analytes were linear over three orders of magnitude with the correlation coefficients greater than 0.999.The average recoveries,precision,reproducibility and stability for two analytes(AF and AFG)were 99.5% and 100.9%,0.43% and 0.47%,0.46% and 0.43%,0.41% and 0.49%,respectively.[Conclusion]This method was successfully applied for quantifying AF and AFG in red ginseng and the method was efficient,sensitive and accurate.展开更多
[Objective] To investigate the optimal determination conditions of melamine in animal blood products by high performance liquid chromatography (HPLC). [ Method] The blood samples were extracted with ultrasonic in 1%...[Objective] To investigate the optimal determination conditions of melamine in animal blood products by high performance liquid chromatography (HPLC). [ Method] The blood samples were extracted with ultrasonic in 1% trichloroacetic acid (TDA) and acetonitrile. After purifying by solide phase extraction (SPE), the samples were analyzed by H PLC. r Result I The optimal conditions of HPLC were as follows: the chromatographic column was Zorbax SB-CS; the mobile phase was ion-pairs buffer-acetonitrile (95/5, V/V) ; the flow rate was 1.0 ml/min; the column temperature was 25 ℃ and the UV detection wavelength was 235 nm. The determined melamine concentration range was 0.001 -0.050 mg/ml; the linear correlation coefficient was 0.999 4; the concentration limit of melamine was 0.1 mg/kg; the average recovery rate of the melamine were 97.60% - 100.65%, and the relative standard deviation (RSD) was 1.23% -3.04%.[ Conclusion] The HPLC is simple, accurate and repeatable for determination of the melamine in animal blood products.展开更多
As a highly sensitive and stable detector,refractive index detector is usually used for quantitative detection of substances such as polymer,sugar and organic acid. The research reviewed the application of HPLC-RID in...As a highly sensitive and stable detector,refractive index detector is usually used for quantitative detection of substances such as polymer,sugar and organic acid. The research reviewed the application of HPLC-RID in the fields of quantitative determination of medicine and food,in order to lay a foundation for wider use of RID.展开更多
Objective To determine residual acrylamide in medical polyacrylamide hydrogel by high performance liquid chromatography tandem mass spectroscopy (HPLC-MS). Methods After 13C3 labeled acrylamide was added, the sample...Objective To determine residual acrylamide in medical polyacrylamide hydrogel by high performance liquid chromatography tandem mass spectroscopy (HPLC-MS). Methods After 13C3 labeled acrylamide was added, the sample was extracted with water and then cleaned up with ExtrelutTM 20. The polyacrylamide hydrogel sample and 20 clinical cases were analyzed by HPLC-MS/MS and isotope dilution quantifying technique in selected reaction monitoring (SRM) mode. Results Acrylamide was separated from polyacrylamide hydrogel. The concentration of acrylamide in polyacrylamide hydrogel ranged from 3.9×10^-9 to 3.1×10^- 8g/L in the 20 clinical cases. The peak area was favorable linear and the range was up to 3 000 μg/L. The recovery rate was 103.1% with a relative standard deviation (RSD) of 6.20%, when the mark level was 50 lag/L. Conelusion HPLC-MS is a rapid, accurate, and sensitive method for the determination of residual acrylamide in medical polyacrylamide hydrogel.展开更多
文摘In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Scientific C18 column (250 mm×4.6 mm, 5 μm) as the chromatographic column and acetonitrile and water as the mobile phase, and the excitation wavelength and emission wavelength of fluorescence detector were 286 and 430 nm, respectively. The response was high, and the linear range was 0.5-10.0 ng/ml. The lowest limit of detection was 0.11 ng/ml, and the average recovery was 92.5%. This method is suitable for quantitative analysis of benzo[a]pyrene content in edible oil.
文摘A rapid, fast and precise method has been developed and validated for the simultaneous determination of amlodipine with H1-receptor antagonists (cetirizine, fexofenadine, and buclizine) from dosage forms. The chromatography was performed on a Purospher? Star, C18 (5 mm, 250 × 4.6 mm) column using acetonitrile: buffer (0.01 mM) (40:60, v/v, pH adjusted to 3.0), as a mobile phase. The mobile phase was pumped at a flow rate of 1.0 mL·min-1 and UV detection was performed at 240 nm. The method was validated for linearity, accuracy, precision and specificity. The method was applied to study the interaction between amlodipine and H1-receptor antagonists. These interactions were carried out in simulated gastric juice (pH 1), simulated full stomach (pH 4), blood pH (pH 7.4) and simulating GI (pH 9). The interacting drugs were heated at 37℃ with intermit-tent shaking and the samples were withdrawn every thirty minutes for three hours and drug contents were analyzed by RP-HPLC techniques. In most cases the in vitro availability of amlodipine was decreased. It was observed that the change in in vitro availability was pH dependent.
文摘Modification was made on the reversed-phase high performance liquidchromatography(RP-HPLC)with Yue et al’s method as a base.The modified RP-HPLCwas used to detect leukotriene B<sub>4</sub>(LTB<sub>4</sub>)and 5-hydroxyeicosatetraenoic acid(5-HETE).Itwas found that the modified method has the merits of simpler procedures,shortertesting time and more satisfactory efficacy.
文摘Objective High performance liquid chromatography(HPLC)and liquid chromatography-mass spectrometry(LC/MS)methods were developed for the determination of ganciclovir and its related substances.Methods A Hypersil ODS2 column(4.6 mm×250 mm,5 μm)was used with a mobile phase of 0.02 M potassium dihydrogen phosphate buffer(pH 6.0)-methanol(92∶8)at a flow rate of 1.0 mL/min,and UV detector set at 254 nm was used for monitoring the eluents.Results The method was simple,rapid,selective and capable of separating all related substances at trace level with a detection limit of 0.04 μg/mL.It has been validated with respect to accuracy,precision,linearity,and limits of detection and quantification.The linearity range was 10.2-153.0 μg/mL with r=0.9998.The percentage recoveries ranged from 96.7% to 101.6%,and RSD was 1.24%-1.96%(n=5).Conclusion The method was found to be suitable not only for monitoring the reactions during the process development but also for quality control of ganciclovir.For identification of related substances,LC/MS was used.The mainly related substances of ganciclovir active pharmaceutical ingredients(API)were determined as guanine,(1,3-dioxolan-4-yl)methyl acetate,and diacetyl guanine.
基金Supported by the Science and Technology Plan of Liaoning Province, China(No.2006226002)the Project of the Doctor Fund of Hebei University of Science and Technology, China(No.005121)
文摘An efficient preparative method was successfully developed for isolation and purification of unstable components from medicinal plant extracts, using a combined method of preparative high performance liquid chro-matography(HPLC) and solid-phase extraction(SPE). The aim of this study was to obtain an effective method with high preparative efficiency and importantly to avoid the transformation of unstable compounds. The preparative HPLC system was based on an LC/MS controlled four-channel autopurification system. The SPE method was performed with a C18 packing material to trap the target compounds and to remove the acidic additive derived from the mobile phase. Using this method, the unstable iridoid glucosides(IGs) as model compounds were successfully isolated and purified from the extract of Hedyotis diffusa Willd. Six IGs(including one new minor IG) and one nucleotide compound were simultaneously obtained, each with a purity of 91% as determined by HPLC. The structures of the isolated compounds were identified by UPLC/Q-TOF MS, UV, 1D and/or 2D NMR. It was demonstrated that the combination of preparative HPLC with SPE is a versatile tool for preparative purification of unstable compounds from complex natural products.
基金funded by the grants from the China Natural Science Foundation ( 30671208 and 40773062)Key Project of Guangdong Natural Science Foundation ( 07117909)Science and Technology Planning Project of Guangdong Province( 2005B20801002 and 2006B20601003)
文摘[Objective] To develop a solid phase extraction-high performance liquid chromatography-fluorescence method for determination of quin- olone antibiotics in water. [ Metbod] The standard curves of four quinolones (norfloxacin, ciprofloxacin, Iomefloxacin and enrofloxacin) were pre- pared. The detection limit in water and recovery were determined. The water samples collected from different areas, river and tap water were trea- ted using solid-phese extraction method and analyzed by high performance liquid chromatography. Then the concentration of quinolones antibiotics was determined by fluorescence method. [ Result] The detection limit of quinolone antibiotics in water was 0.083 -0.248 μg/L, and their recovery was 63.7% -134.1%. The four quinolone antibiotics at different levels were detected in various water samples, and the total concentration of quin- olone antibiotics was 0.045 -3.969 μg/L. The total concentration of quinolone antibiotics was higher in the water samples collected from rivers in Shenzhen area than in the sewage samples. The four quinolone antibiotics could be detected in all tap water samples. [ CoaduLsion ] The solid phase extraction-high performance liquid chromatography-fluorescence method is feasible and effective to detect quinolones in water. In addition, this method needs low cost and can meet requirements of daily monitorina and analysis.
文摘A new type of HPLC stationary phase containing thymine derivative was successfully prepared.It was found to give selective separation of nucleic acid bases and several purine derivatives,such as caffeine and theophylline.The retention behaviour and elution order of the solutes were interpreted in terms of molecular structure.
基金This research was supported by Special Research Fund for Young Doctors of Qiqihar Medical University(QMSI2020B-03,hosted by Wenjing Li).
文摘A low cost,rapid and sensitive preparation method of silica gel supported ionic liquid(SGSIL)combined with matrix solid phase dispersion(MSPD)followed by high performance liquid chromatography(HPLC)with ultraviolet detection(UV)is proposed,and it was applied to determine the seven active compounds in Salvia Miltiorrhiza herb.SGSIL and ionic liquid[BMIM]BF4 were used as the adsorbent and the green elution reagent in the MSPD procedure.Several extraction conditions including type of filler and elution solvent,the volume of elution solvent,material liquid ratio were optimized.Under the optimum conditions,the SGSIL-MSPD-HPLC method showed a low limit of detection(LOD,S/N=3)of 0.0122-0.8788μg/mL for standard solution,limit of quantification(LOQ,S/N=10)of 0.0406-2.9292μg/mL for standard solution,wide linear range from 1.56 to 2000μg/mL for all compounds for standard solution,correlation coefficients(r)of more than 0.9990,acceptable reproducibility(relative standard deviations,RSDs<3.54%),and precision of RSDs<3.36%for intra-day,RSDs<3.50%for inter-day.The satisfactory recoveries ranged from 96.4 to 102.5,with RSDs less than 3.45%.The developed SGSIL-MSPD method is easier and more suitable for the determination of the seven active compounds in Salvia Miltiorrhiza herb than the traditional ultrasonic extraction.It was an effective and efficient method for the extraction and quantification of the seven active compounds in traditional Chinese herbal samples.
基金Project(20776038)supported by the National Natural Science Foundation of China
文摘The chiral separation of phenylsuccinic acid(PSA)was studied by reversed phase high-performance liquid chromatography(RP-HPLC)with cyclodextrins(CDs)as chiral mobile phase additives.The effects of types of CDs,concentration of hydroxypropyl-β-cyclodextrin(HP-β-CD),percentage of organic modifier,pH value and column temperature on enantioselective separation were investigated.The quantification property of the developed RP-HPLC method was examined.The chiral recognition mechanism of PSA was also discussed.The results show that a baseline separation of PSA enantiomers is achieved on a Lichrospher C18 column(4.6 mm(inner diameter)×250 mm,5μm)with HP-β-CD as chiral mobile phase additive.The capacity factors of R-PSA and S-PSA are 3.94 and 4.80,respectively.The separation factor and resolution are respectively 1.22 and 8.03.The mobile phase is a mixture of acetonitrile and deionized water(20-80,volume ratio)containing 10 mmol/L HP-β-CD and 0.05% trifluoroacetic acid(pH 2.5,adjusted with triethylamine)with a flow rate of 1.0 mL/min.The ultraviolet(UV)detector is set at 254 nm.The likely roles are inclusion interaction,induction and hydrogen bonding between HP-β-CD and PSA enantiomers.
文摘A simple, precise, accurate and sensitive reverse phase high performance liquid chromatographic method for simultaneous estimation of lisinopril dihydrate and its degradation products occuring under different ICH prescribed stress conditions has been modified. Drug was resolved on a C18 column, utilizing modified mobile phase of tetra butyl ammonium hydroxide solution and acetonitrile. Ultra violet detection was carried out at 210 nm. The method was modified with respect to linearity, precision, accuracy, selectivity, specificity and ruggedness. The results obtained revealed that lisinopril dihydrate was an active product slightly changed under stress conditions.
基金supported both by the Natural Science Foundations of Hebei(No.B2008000210)the Scientific Research Foundation of Agricultural University of Hebei.
文摘A novel method for the determination of five carbamate pesticides (metolcarb, carbofuran, carbaryl, isoprocard and diethofencard) in water samples was developed by dispersive liquid-liquid microextraction (DLLME) coupled with high performance liquid chromatography-diode array detector (HPLC-DAD). Some experimental parameters that influence the extraction efficiency were studied and optimized to obtain the best extraction results. Under the optimum conditions for the method, the calibration curve was linear in the concentration range from 5 to 1000 ng mL^-1 for all the five carbamate pesticides, with the correlation coefficients (r^2) varying from 0.9984 to 0.9994. Good enrichment factors were achieved ranging from 80 to 177- fold, depending on the compound. The limits of detection (LODs) (S/N = 3) were ranged from 0.1 to 0.5 ng mL^-1. The method has been successfully applied to the analysis of the pesticide residues in environmental water samples.
文摘HPLC method for analysis of the flavonoids from ginkgo biloba extract (GBE) was studied. By suitable selection of columns. symmetrical chromatographic peaks were obtained without using acidic modifier in the mobile phase, which can eliminate the time for cleaning the chromatographic system and simplify the analystic method for GBE Experimental conditions: column: Hypersil BDS C-18, 5mumx4x250 mm: column temperature: 35degreesC; mobile phase: 46% methanol-54% water; flow rate: 0.7 mL/min; detection wavelength: 360nm.
文摘The most suitable bio-analytical method based on liquid liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard for Rasagiline. Zorbax Eclipse Plus C18 (2.1 mm × 50 mm, 3.5 um) column provided chromatographic separation of analyte followed by detection with mass spectrometry. The method involved simple isocratic chromatographic condition and mass spectrometric detection in the positive ionization mode using an API-4000 system. The lotal run time was 3.0 min. The proposed method has been validated with the linear range of 5 12000 pg/mL for Rasagiline. The intra-run and inter-run precision values were within 1.3% 2.9% and 1.6% 2.2% respectively for Rasagiline. The overall recovery for Rasagiline and Rasagiline-13C3 mesylate analog was 96.9% and 96.7% respectively. This validated method was successfully applied to the bioequivalence and pharmacokinetic study of human volunteers under fasting condition.
文摘Objective: To develop the representative fingerprint for the quality control of placenta polypeptide injection. Methods: The chromatographic separation was performed using a Phenomenex Gemini C18 column (250 mm 4.6 mm, 5 mm) maintained at 30 1C. 0.1% aqueous trifiuoroacetic acid (Solvent A) and acetonitrile contained 0.1% TFA (Solvent B) were used as mobile phase with a gradient elution. Detection wavelength was 280 nm with the sample injection volume of 50 mL; the fiow rate was 1.0 mL/min. The fingerprints of different samples were investigated by similarity analysis. Results: Nine peaks were identified as the characteristic common peaks. The similarities of the fingerprints of the 10 batches of samples were above 0.992. Conclusion: This method showed high precision and good repeatability, and provided the basis for the improvement of the quality control of placenta polypeptide injection.
基金Project supported by the National Natural Science Foundation of China (No.20437020)Major Research Program of Chinese Academy of Sciences (No.KZCX3-SW-432).
文摘Seven polycyclic aromatic hydrocarbons (PAHs) in atmospheric particulates were determinated by high performance liquid chromatography (HPLC) with fluorescence detector using direction injection and an on-line enrichment trap column. The method simplified the sample pretreatment, saved time and increased the efficiency. With the on-line trap column, PAHs were separated availably even underground injecting 1.0 ml sample with relatively high column efficiency. The recoveries of the seven PAHs were from 85% to 120% for spiked atmospheric particulate sample. The limit of detection was 15.3-39.6 ng/L (S/N=3.3). There were good linear correlations between the peak areas and concentrations of the seven kinds of PAHs in the range of 1-50 ng/ml with the correlation coefficients over 0.9970. Furthermore, it also indicated that the method is available to determine PAHs in atmospheric particulates well.
基金This work was supported by the National Natural Science Foundation of China (Grant No. 30560171).
文摘To determine dopamine and its metabolites during in vivo cerebral microdialysis by routine high performance liquid chromatography with electrochemical detection. Methods Microdialysis probes were placed into the right striatum of Wistar rat brains and perfused with Ringer's solution at a rate of 1.5 pL/min. A reverse phase HPLC with electrochemistry was used to assay DA, DOPAC, and HVA after cerebral microdialysates were collected every 20 minutes from awake and freely moving rats. In order to identify the reliability of this method, its selectivity, linear range, precision and accuracy were tested and the contents of DA, DOPAC, and HVA in rat microdialysates were determined. Results The standard curve was in good linear at the concentration ranging from 74 nmol/L to 1.5 pmol/L for DOPAC (r^2= 0.9996), from 66 nmol/L to 1.3 gmol/L for DA (r^2=l.0000) and from 69 nmol/L to 1.4 pmol/L for HVA (r^2=0.9992). The recovery of DOPAC (0.30, 0.77, 1.49 gmol/L), DA (0,26, 0.69, 1.32 gmol/L), and HVA (0.27, 0.71, 1.37 gmol/L) was 82.00±1.70%, 104.00±4.00%, 98.70±3.10%; 92.30± 1.50%, 105.30±2.30%, 108.00±2.00%; 80.00±7.80%, 107.69±8.00%, and 108.66±3.10%, respectively at each concentration. Their intra-day RSD was 3.3%, 3.4%, and 2.5%, and inter-day RSD was 4.2%, 2.3%, and 5.6%, respectively. The mean extracellular concentrations of DOPAC, DA, and HVA in rat brain microdialysates were 10.7, 2.4, and 9.2 gmol/L (n=6), respectively. Conclusion The findings of our study suggested that the simple, accurate and stable method can be applied to basic researches of diseases related to monoamines neurotransmitters by cerebral microdialysis in rats.
文摘[Objective]The paper was to establish a method for determining AF and AFG in red ginseng.[Method]A new simple,rapid and sensitive method for simultaneous determination of two amadori compounds,arginyl-fructose(AF)and arginyl-fructosyl-glucose(AFG),in extracts of three kinds of ginseng preparations was developed and validated using high performance liquid chromatography with evaporative light scattering detector(HPLC-ELSD).Two target analytes were efficiently separated by Prevail CTM18 column(4.6 mm×250 mm,5μm)at the flow rate of 0.8 mL/min within 15 min of single chromatographic run.[Result]Under optimized conditions,the detection limits were 0.015 and 0.02 mg/mL for AF and AFG,respectively.Calibration curves of peak area for two analytes were linear over three orders of magnitude with the correlation coefficients greater than 0.999.The average recoveries,precision,reproducibility and stability for two analytes(AF and AFG)were 99.5% and 100.9%,0.43% and 0.47%,0.46% and 0.43%,0.41% and 0.49%,respectively.[Conclusion]This method was successfully applied for quantifying AF and AFG in red ginseng and the method was efficient,sensitive and accurate.
基金supported by the Shanghai Key Development Project of Agriculture Science and Technology (2009 No.6-3)
文摘[Objective] To investigate the optimal determination conditions of melamine in animal blood products by high performance liquid chromatography (HPLC). [ Method] The blood samples were extracted with ultrasonic in 1% trichloroacetic acid (TDA) and acetonitrile. After purifying by solide phase extraction (SPE), the samples were analyzed by H PLC. r Result I The optimal conditions of HPLC were as follows: the chromatographic column was Zorbax SB-CS; the mobile phase was ion-pairs buffer-acetonitrile (95/5, V/V) ; the flow rate was 1.0 ml/min; the column temperature was 25 ℃ and the UV detection wavelength was 235 nm. The determined melamine concentration range was 0.001 -0.050 mg/ml; the linear correlation coefficient was 0.999 4; the concentration limit of melamine was 0.1 mg/kg; the average recovery rate of the melamine were 97.60% - 100.65%, and the relative standard deviation (RSD) was 1.23% -3.04%.[ Conclusion] The HPLC is simple, accurate and repeatable for determination of the melamine in animal blood products.
文摘As a highly sensitive and stable detector,refractive index detector is usually used for quantitative detection of substances such as polymer,sugar and organic acid. The research reviewed the application of HPLC-RID in the fields of quantitative determination of medicine and food,in order to lay a foundation for wider use of RID.
文摘Objective To determine residual acrylamide in medical polyacrylamide hydrogel by high performance liquid chromatography tandem mass spectroscopy (HPLC-MS). Methods After 13C3 labeled acrylamide was added, the sample was extracted with water and then cleaned up with ExtrelutTM 20. The polyacrylamide hydrogel sample and 20 clinical cases were analyzed by HPLC-MS/MS and isotope dilution quantifying technique in selected reaction monitoring (SRM) mode. Results Acrylamide was separated from polyacrylamide hydrogel. The concentration of acrylamide in polyacrylamide hydrogel ranged from 3.9×10^-9 to 3.1×10^- 8g/L in the 20 clinical cases. The peak area was favorable linear and the range was up to 3 000 μg/L. The recovery rate was 103.1% with a relative standard deviation (RSD) of 6.20%, when the mark level was 50 lag/L. Conelusion HPLC-MS is a rapid, accurate, and sensitive method for the determination of residual acrylamide in medical polyacrylamide hydrogel.