期刊文献+
共找到2,541篇文章
< 1 2 128 >
每页显示 20 50 100
Fault Locator Using Two-end Unsynchronized Measurements for UHV Series Compensated Double-circuit Lines
1
作者 M. Fulczyk P. Balcerek +2 位作者 J. Izykowski E. Rosolowski M. M. Saha 《高电压技术》 EI CAS CSCD 北大核心 2008年第12期2523-2529,共7页
An accurate fault location algorithm for double-circuit series compensated lines is presented.Use of two-end unsynchronized measurements of current and voltage signals is considered.The algorithm applies two subroutin... An accurate fault location algorithm for double-circuit series compensated lines is presented.Use of two-end unsynchronized measurements of current and voltage signals is considered.The algorithm applies two subroutines,designated for locating faults on particular line sections,and additionally the procedure for selecting the valid subroutine.The subroutines are formulated with use of the generalized fault loop model and the distributed parameter line model is applied.Performed ATP-EMTP based evaluation has shown the validity of the derived fault location algorithm and its high accuracy. 展开更多
关键词 两端非同步测量法 串联补偿 线路故障 定位仪 ATP-EMTP
下载PDF
Process Analysis of Double Circuit Transmission Line Trip-out on the Same Tower Due to Lightning
2
作者 DUAN Da-peng REN Zhi-gang WANG Peng YE Kuan CHANG Xiao-qi LI Wei 《高压电器》 CAS CSCD 北大核心 2011年第9期31-36,43,共7页
In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave th... In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave threat to the power grid security.The cause of the accident and the accident process were studied for the sake of further understanding of the impact of lightning on power grid.As an example,110 kV double circuit transmission line(Xilong-line) was analyzed.At first,the system topology was given.Through the analysis on relay protection actions and the fault recorder data,over voltage on the insulator strings was calculated.Based on the analysis and the calculation,accident cause and the process were presented respectively.Secondly,it comes to the conclusion that the lightning failure was caused by counterattack.The wave of the lightning over voltage would spread to the not grounded neutral point of the transformers,and make the neutral protective gap breakdown,then cause freewheeling with the frequency of 50 Hz.As results of the relay protection,the double circuit transmission line all tripped out.Finally,the causes of the accident were proposed that included terrain features,large corner towers,strong thunderstorm weather and poor grounded contact of the tower. 展开更多
关键词 double circuit transmission lines on the same tower lightning trip-out at the same time fault recorder over-voltage calculation lightning protection
下载PDF
Design of Bidirectional Coupling Circuit for Broadband Power-Line Communications
3
作者 Syed Samser Ali Amitabha Bhattacharya Dipak Ranjan Poddar 《Journal of Electromagnetic Analysis and Applications》 2012年第4期162-166,共5页
This paper deals with the design of bidirectional coupler for broadband power line communication and the impedance matching technique with the power line. This coupler can be used for both transmitting and receiving t... This paper deals with the design of bidirectional coupler for broadband power line communication and the impedance matching technique with the power line. This coupler can be used for both transmitting and receiving the data, acting as transceiver. The impedance mismatching problem is also solved here using line trap circuit. The coupler circuit is capable of transmitting or receiving modulated signals with carrier frequency of 15 MHz which can be used for domestic as well as distribution power networks. Laboratory prototype tested using power line network consists of electrical household appliances and results show that the circuit is able to facilitate bidirectional band pass transmission. 展开更多
关键词 COUPLING circuitS line TRAP circuit BROADBAND
下载PDF
Three-dimensional Model Analysis of Electric Field Excited by Multi-circuit Intersecting Overhead Transmission Lines 被引量:2
4
作者 XIAO Dongping LEI Hui ZHANG Zhanlong HE Wei 《高电压技术》 EI CAS CSCD 北大核心 2013年第8期2006-2013,共8页
This work is carried out to predict the special distribution of electric field induced by multi-circuit intersecting overhead high-voltage (HV) transmission lines (TLs) within a large range without any expensive and t... This work is carried out to predict the special distribution of electric field induced by multi-circuit intersecting overhead high-voltage (HV) transmission lines (TLs) within a large range without any expensive and time-consuming computation. The two main parts of the presented methodology are 1) setting up a three-dimensional (3D) model to calculate the electric field based on combining ca- tenary equations with charge simulation method and 2) calculating the hybrid electric field excited by multi-circuit intersecting TLs using coordinate transformation and superposition technique. Examples of different TLs configurations, including a 220 kV single-circuit hori- zontally configured TLs, a 500 kV single-circuit triangularly configured TLs and a combination of the 220 kV TLs and the 550 kV TLs, are illustrated to verify the validity of this methodology. A more complicatal configurations, including a 500 kV double-circuit TLs and two 220 kV single-circuit horizontally configured TLs, are also calculated. Conclusions were drawn from the simulation: 1) The presented 3D model outperforms 2D models in describing the electric field distribution generated by practical HV TLs with sag and span. 2) Coordinate trans- formation and superposition technique considerably simplify the electric field computation for multi-circuit TLs configurations, which makes it possible to deal with complex engineering problems. 3) The electric field in the area covered by multiple intersecting overhead TLs is distorted and the hybrid electric field strength in some partial region increases so sharply that it might exceed the admissible value. 4) The configuration parameters of the TLs and the spatial configuration of multi-circuit TLs, for instance, the height of TLs, the length of span and the intersection angle of multiple circuits, influence the strength and the distribution of hybrid electric field. The influence regularities sum- marized in this paper can be referred by future TL designs to meet the electromagnetic environmental protection regulations. 展开更多
关键词 架空输电线路 电场分布 模型分析 相交 三维 多路 激发 220千伏
下载PDF
A Novel Fault Location Algorithmfor Double-Circuit Transmission Lines based on Distributed Parameter
5
作者 商立群 施围 《电工电能新技术》 CSCD 北大核心 2006年第1期13-16,20,共5页
Anewfault location algorithmfor double-circuit transmissionlines is described inthis paper.Theproposed method uses data extractedfromtwo ends of the transmissionlines andthus eliminates the effects ofthe source impeda... Anewfault location algorithmfor double-circuit transmissionlines is described inthis paper.Theproposed method uses data extractedfromtwo ends of the transmissionlines andthus eliminates the effects ofthe source impedance andthe fault resistance.The distributed parameter model and the modal transformationare also employed.Depending on modal transformation,the coupled equations of the lines are converted intodecoupled ones.Inthis way,the mutual coupling effects between adjacent circuits of the lines are eliminatedandtherefore an accurate fault location can be achieved.The proposed methodis tested via digital simulationusing EMTP in conjunction with MATLAB.The test results corroborate the high accuracy of the proposedmethod. 展开更多
关键词 双回路输电线路 节点数据 故障分析 分布参数
下载PDF
Research on Total Electric Field for DC Lines Converted from Double-Circuit AC Lines
6
作者 Xiaoqian Ma Jiayu Lu +1 位作者 Kun He Wensheng Gao 《Energy and Power Engineering》 2017年第4期598-610,共13页
With rapid growth of power demand, transmission capacity is also in urgent need of upgrading. In some cases, converting existing AC transmission lines to DC lines can Improve the transmission capacity and reduce the c... With rapid growth of power demand, transmission capacity is also in urgent need of upgrading. In some cases, converting existing AC transmission lines to DC lines can Improve the transmission capacity and reduce the construction investment. In this paper, the upstream finite element method was expanded to calculate the total electric field of same tower multi-circuit DC lines converted from double-circuit AC lines, and the validity of the algorithm was confirmed by experiments. Taking a DC line converted from a typical same tower 500 kV double-circuit AC transmission line as an example, the surface electric field and the ground total electric field in different pole conductor arrangement schemes were calculated and analyzed, and the critical height of pole conductors for DC lines in residential and non-residential area were determined. Then, the corridor width of DC and AC lines at critical height in residential and non-residential areas before and after AC-DC line transformation were compared. The results indicate that for DC lines converted from common 500 kV double-circuit AC lines, the ground total electric field can meet the requirements of corresponding standard with appropriate pole conductor arrangement schemes. 展开更多
关键词 DC lineS Converted from AC lineS Multi-circuit DC line at SAME Tower Pole Conductor BUNDLES Arrangement Scheme Total Electric Field line-to-Ground Distance Corridor Width
下载PDF
TRANSIENT ANALYSIS OF TRANSMISSION LINE CIRCUITS BASED ON THE SEMIDISCRETIZATION OF TELEGRAPH EQUATIONS
7
作者 Guo Yushun(Hangzhou Institute of Electronic Engineering, Hangzhou 310037) 《Journal of Electronics(China)》 2001年第1期46-55,共10页
A new transient analysis method for the transmission line circuits is presented in this paper. Based on the semidiscretization of the telegraph equations, a discretized time domain companion models for the transmissio... A new transient analysis method for the transmission line circuits is presented in this paper. Based on the semidiscretization of the telegraph equations, a discretized time domain companion models for the transmission lines which can be conveniently implemented in a general circuit simulator such as SPICE is derived. The computation required for the model is linear with time, equivalent to the recursive convolution-based method. The formulations for both single and coupled lossy transmission lines are given. Numerical experiments are carried out to demonstrate the validity of the method. 展开更多
关键词 VLSI interconnects Transmission line analysis circuit simulation
下载PDF
Effect of closed circuits drip irrigation system and lateral lines length on growth, yield, quality and water use efficiency of soybean crop
8
作者 Mohamed Yousif Tayel Hani Abdel-Ghani Mansour Sabreen Khalil Pibars 《Agricultural Sciences》 2013年第2期85-90,共6页
Field experiment was conducted for one growing season (2012) in clay loam soil at the Experimental Farm of Faculty of Agriculture, Southern Illinois University at Carbondale (SIUC), USA on soybean crop to study the ef... Field experiment was conducted for one growing season (2012) in clay loam soil at the Experimental Farm of Faculty of Agriculture, Southern Illinois University at Carbondale (SIUC), USA on soybean crop to study the effect of: 1) the closed drip irrigation system: closed circuits with one and two a manifolds for lateral lines (CM1DIS;CM2DIS) and traditional drip irrigation system (TDIS) as a control;and 2) lateral lines length (LLL): LLL1, LLL2 and LLL3 (40, 60,80 m) on soybean growth, yield, oil, protein content and water use efficiency. Plants were drip irrigated every 4 days. N, K2O and P2O5 fertilizers were added via irrigation water. Data obtained could be outlined as follows: 1) According to the mean values of soybean crop growth (leaf area;plant height), yield (grain and straw), both oil and protein content and water use efficiency, the treatment used could be ranked in the following ascending orders: TDIS < CM1DIS < CM2DIS and LLL3 < LLL2 < LLL1;2) Differences in the means of the studied data among treatments used were significant at the 1% level;3) The effects of the DIC × LLL on the data obtained were significant at the 1 % level;And 4) the highest values of the obtained data and the lowest ones were achieved in the following interactions: CM2DIS × LLL1;TDIS × LLL3, respectively. 展开更多
关键词 Closed circuits DRIP IRRIGATION Lateral lines SOYBEAN WUE
下载PDF
One high-efficiency analysis method for high-speed circuit networks containing distributed parameter elements 被引量:2
9
作者 Lei DOU Zhiquan WANG 《控制理论与应用(英文版)》 EI 2005年第2期117-120,共4页
In the field of high-speed circuits, the analysis of mixed circuit networks containing both distributed parameter elements and lumped parameter elements becomes ever important. This paper presents a new method for ana... In the field of high-speed circuits, the analysis of mixed circuit networks containing both distributed parameter elements and lumped parameter elements becomes ever important. This paper presents a new method for analyzing mixed circuit networks. It adds transmission line end currents to the circuit variables of the classical modified nodal approach and can be applied directly to the mixed circuit networks. We also introduce a frequency-domain technique without requiring decoupling for multiconductor transmission lines. The two methods are combined together to efficiently analyze high-speed circuit networks containing uniform,nonuniform,and frequency-dependent transmission lines. Numerical experiment is presented and the results are compared with that computed by PSPICE. 展开更多
关键词 Distributed parameter Multiconductor transmission lines circuit networks Transient analysis
下载PDF
A monolithic distributed phase shifter based on right-handed nonlinear transmission lines at 30 GHz 被引量:1
10
作者 黄杰 赵倩 +2 位作者 杨浩 董军荣 张海英 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第12期451-455,共5页
The epitaxial material, device structure, and corresponding equivalent large signal circuit model of GaAs planar Schottky varactor diode are successfully developed to design and fabricate a monolithic phase shifter, w... The epitaxial material, device structure, and corresponding equivalent large signal circuit model of GaAs planar Schottky varactor diode are successfully developed to design and fabricate a monolithic phase shifter, which is based on right-handed nonlinear transmission lines and consists of a coplanar waveguide transmission line and periodically distributed GaAs planar Schottky varactor diode. The distributed-Schottky transmission-line-type phase shifter at a bias voltage greater than 1.5 V presents a continuous 0°–360° differential phase shift over a frequency range from 0 to 33 GHz. It is demonstrated that the minimum insertion loss is about 0.5 dB and that the return loss is less than-10 dB over the frequency band of 0–33 GHz at a reverse bias voltage less than 4.5 V. These excellent characteristics, such as broad differential phase shift, low insertion loss, and return loss, indicate that the proposed phase shifter can entirely be integrated into a phased array radar circuit. 展开更多
关键词 GaAs planar Schottky diode phase shifter right-handed nonlinear transmission lines monolithic microwave integrated circuit
下载PDF
Model of Three-Phase Transmission Line with the Theory of Modal Decomposition Implied 被引量:1
11
作者 Rodrigo Cleber da Silva Sérgio Kurokawa 《Energy and Power Engineering》 2013年第4期1139-1146,共8页
This paper shows the development of transmission line model, based on lumped element circuit that provides answers directly in the time and phase domain. This model is valid to represent the ideally transposed line, t... This paper shows the development of transmission line model, based on lumped element circuit that provides answers directly in the time and phase domain. This model is valid to represent the ideally transposed line, the phases of each of the small line segments are separated in their modes of propagation and the voltage and current are calculated at the modal domain. However, the conversion phase-mode-phase is inserted in the state equations which describe the currents and voltages along the line of which there is no need to know the user of the model representation of the theory in the line modal domain. 展开更多
关键词 π-circuits ELECTROMAGNETIC Transients TRANSMISSION lineS TRANSMISSION line Models
下载PDF
Influences of Switching Jitter on the Operational Performances of Linear Transformer Drivers-Based Drivers 被引量:2
12
作者 刘鹏 孙凤举 +3 位作者 魏浩 王志国 尹佳辉 邱爱慈 《Plasma Science and Technology》 SCIE EI CAS CSCD 2012年第4期347-352,共6页
A whole circuit model of a linear transformer drivers (LTD) module composed of 60 cavities in series was developed in the software PSPICE to study the influence of switching jitter on the operational performances of... A whole circuit model of a linear transformer drivers (LTD) module composed of 60 cavities in series was developed in the software PSPICE to study the influence of switching jitter on the operational performances of LTDs. In the model, each brick in each cavity is capable of operating with jitter in its switch. Additionally, the manner of triggering cables entering into cavities was considered. The performances of the LTD module operating with three typical cavity-triggering sequences were simulated and the simulation results indicate that switching jitter affects slightly the peak and starting time of the output current pulse. However, the enhancement in switching jitter would significantly lengthen the rise time of the output current pulse. Without considering other factors, a jitter lower than 10 ns may be necessary for the switches in the LTD module to provide output current parameters with an acceptable deviation. 展开更多
关键词 linear transformer drivers (LTDs) circuit model pulsed power transmission line JITTER trigger delay
下载PDF
Numerical Analysis of the Output-Pulse Shaping Capability of Linear Transformer Drivers 被引量:2
13
作者 刘鹏 孙风举 +1 位作者 尹佳辉 邱爱慈 《Plasma Science and Technology》 SCIE EI CAS CSCD 2011年第2期246-251,共6页
Output-pulse shaping capability of a linear transformer driver (LTD) module under different conditions is studied, by conducting the whole circuit model simulation by using the PSPICE code. Results indicate that a h... Output-pulse shaping capability of a linear transformer driver (LTD) module under different conditions is studied, by conducting the whole circuit model simulation by using the PSPICE code. Results indicate that a higher impedance profile of the internal transmission line would lead to a wider adjustment range for the output current rise time and a narrower adjustment range for the current peak. The number of cavities in series has a positive effect on the output- pulse shaping capability of LTD. Such an improvement in the output-pulse shaping capability can primarily be ascribed to the increment in the axial electric length of LTD. For a triggering time interval longer than the time taken by a pulse to propagate through the length of one cavity, the output parameters of LTD could be improved significantly. The present insulating capability of gas switches and other elements in the LTD cavities may only tolerate a slightly longer deviation in the triggering time interval. It is feasible for the LTD module to reduce the output current rise time, though it is not useful to improve the peak power effectively. 展开更多
关键词 linear transformer driver (LTD) circuit model pulsed power transmission line impedance profile trigger delay
下载PDF
Broadband microwave frequency doubler based on left-handed nonlinear transmission lines
14
作者 黄杰 顾雯雯 赵倩 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第3期500-505,共6页
A bandwidth microwave second harmonic generator is successfully designed using composite right/left-handed non- linear transmission lines (CRLH NLTLs) in a GaAs monolithic microwave integrated circuit (MMIC) techn... A bandwidth microwave second harmonic generator is successfully designed using composite right/left-handed non- linear transmission lines (CRLH NLTLs) in a GaAs monolithic microwave integrated circuit (MMIC) technology. The structure parameters of CRLH NLTLs, e.g. host transmission line, rectangular spiral inductor, and nonlinear capacitor, have a great impact on the second harmonic performance enhancement in terms of second harmonic frequency, output power, and conversion efficiency. It has been experimentally demonstrated that the second harmonic frequency is deter- mined by the anomalous dispersion of CRLH NLTLs and can be significantly improved by effectively adjusting these structure parameters. A good agreement between the measured and simulated second harmonic performances of Ka-band CRLH NLTLs frequency multipliers is successfully achieved, which further validates the design approach of frequency multipliers on CRLH NLTLs and indicates the potentials of CRLH NLTLs in terms of the generation of microwave and millimeter-wave signal source. 展开更多
关键词 GaAs planar Schottky diode frequency multiplier composite fight/left-handed transmission line monolithic microwave integrated circuit
下载PDF
ANALYSIS OF THE TRANSMISSION PROPERTIES OF TAPERED MUTLICONDUCTOR INTERCONNECTING BUSES IN HIGH-SPEED INTEGRATED CIRCUITS
15
作者 王秉中 《Journal of Electronics(China)》 1994年第1期22-27,共6页
Analysis approach and formulas for the transmission properties of uniform multicon-ductor interconnecting buses in high-speed integrated circuits are presented in this article. And further, by using a network approach... Analysis approach and formulas for the transmission properties of uniform multicon-ductor interconnecting buses in high-speed integrated circuits are presented in this article. And further, by using a network approach, a tapered bus system can be analyzed as a set of cascaded uniform buses with slightly different strip widths. Obtained results are in good agreement with the experimental data. 展开更多
关键词 High SPEED integrated circuit INTERCONNECTION TRANSMISSION lineS Network SCATTERING PARAMETER
下载PDF
Advances in Developing Transitions in Microwave Integrated Circuits
16
作者 张运传 王秉中 《Journal of Electronic Science and Technology of China》 2005年第1期40-44,共5页
Advances in developing transitions in microwave integrated circuits during the last ten years are reviewed. Some typical structures of transition are introduced. Transition structures can be classified into two basic ... Advances in developing transitions in microwave integrated circuits during the last ten years are reviewed. Some typical structures of transition are introduced. Transition structures can be classified into two basic types: one is transition between the same kind of transmission lines on different planes of a common substrate, the other transition between different types of transmission lines. Furthermore, future development of transition structures is discussed. 展开更多
关键词 ADVANCE transition structure microwave integrated circuits transmission line
下载PDF
特勒根似功率保护在同塔双回交流输电线路中的应用
17
作者 刘世明 曾琦器 +2 位作者 赵文琛 张超 蒋林 《电网技术》 EI CSCD 北大核心 2024年第3期1322-1330,共9页
随着我国电网规模快速扩张,输电通道资源日渐紧缺,同塔多回输电技术逐渐得到广泛应用。超/特高压远距离输电线路一般以差动保护作为双重主保护,与纵联距离/方向保护构成双重化配置。但用于同塔双回输电线路时,分布电容电流将影响差动保... 随着我国电网规模快速扩张,输电通道资源日渐紧缺,同塔多回输电技术逐渐得到广泛应用。超/特高压远距离输电线路一般以差动保护作为双重主保护,与纵联距离/方向保护构成双重化配置。但用于同塔双回输电线路时,分布电容电流将影响差动保护的灵敏度;同时,由于双回线线间和相间较强的电磁耦合作用,线间互感的影响将会降低纵联距离、纵联方向保护判断的正确性,导致原来的保护配置方案难以直接应用。将特勒根似功率保护原理推广至同塔双回线路,提出了一种基于特勒根似功率定理的同塔双回输电线路纵联保护方法,能够不受双回线内部复杂电磁耦合、分布电容、系统负荷等影响,并验证了该保护的对时方案在双回线路中的适用性。采用MATLAB/Simulink仿真软件搭建1000kV特高压同塔双回输电线示范工程模型,经大量仿真实验,验证了所提保护方法的有效性。 展开更多
关键词 特勒根似功率定理 双回输电线路 纵联保护 双重化配置
下载PDF
基于倾斜摄影的多回输电线路实景三维模型构建系统设计
18
作者 姚磊 张雷 +2 位作者 迟兴江 赵留学 戴润东 《电子设计工程》 2024年第15期35-40,共6页
为了使改进多回输电线路三维模型更加符合实际情况,该文将倾斜摄影技术引入多回输电线路实景三维模型构建系统中,提升数据获取的精准性。硬件方面,微处理器作为指令核心处理结构,负责读取并解析指令;设计多回输电线路数据采集模块和EP3S... 为了使改进多回输电线路三维模型更加符合实际情况,该文将倾斜摄影技术引入多回输电线路实景三维模型构建系统中,提升数据获取的精准性。硬件方面,微处理器作为指令核心处理结构,负责读取并解析指令;设计多回输电线路数据采集模块和EP3SE110F1152C4数据存储器,并利用数据存储器对系统运行过程中的多项数据进行存储;软件方面,借助倾斜摄影技术,获取多回输电线路数据,并计算其对应的比例尺和航高,再对获取的数据进行优化,消除数据中的误差,并对其进行配准处理和特征匹配以及纹理映射和归一化处理,由此完成对多回输电线路实景三维模型的构建。经过实验验证,和以往的多回输电线路实景三维模型构建系统相比,设计的基于倾斜摄影的多回输电线路实景三维模型构建系统在实际应用中模型构建完整度为95.6%,构建效果更好。 展开更多
关键词 倾斜摄影 多回输电线路 实景三维模型 特征匹配
下载PDF
多线并行轨道电路电容耦合干扰机理研究
19
作者 傅宗纯 李捷 《科技资讯》 2024年第12期60-62,共3页
高速铁路车站并行股道多,应用场景复杂,在三线并行情况下,中间股道易受两旁线路的电磁干扰影响。当2条线路均与中间股道同向时,中间股道所受电容耦合干扰为2条线路干扰之和,且邻线耦合电容越大,干扰亦越强。为减少多线并行邻线间的电容... 高速铁路车站并行股道多,应用场景复杂,在三线并行情况下,中间股道易受两旁线路的电磁干扰影响。当2条线路均与中间股道同向时,中间股道所受电容耦合干扰为2条线路干扰之和,且邻线耦合电容越大,干扰亦越强。为减少多线并行邻线间的电容耦合干扰,可采取改变线路相对布局、采用屏蔽等设计措施,确保高速铁路车站轨道电路工作的稳定性和可靠性。 展开更多
关键词 高速铁路 多线并行 轨道电路 邻线干扰 电容耦合
下载PDF
On-line detecting of transformer winding deformation based on parameter identification of leakage inductance
20
作者 郝治国 张保会 李朋 《Journal of Pharmaceutical Analysis》 SCIE CAS 2007年第1期24-28,共5页
Transformers are required to demonstrate the ability to withstand short circuit currents.Over currents caused by short circuit can give rise to windings deformation.In this paper,a novel method is proposed to monitor ... Transformers are required to demonstrate the ability to withstand short circuit currents.Over currents caused by short circuit can give rise to windings deformation.In this paper,a novel method is proposed to monitor the state of transformer windings,which is achieved through on-line detecting the leakage inductance of the windings.Specifically,the mathematical model is established for online identifying the leakage inductance of the windings by applying least square algorithm(LSA) to the equivalent circuit equations.The effect of measurement and model inaccuracy on the identification error is analyzed,and the corrected model is also given to decrease these adverse effect on the results.Finally,dynamic test is carried out to verify our method.The test results clearly show that our method is very accurate even under the fluctuation of load or power factor.Therefore,our method can be effectively used to on-line detect the windings deformation. 展开更多
关键词 Leakage inductance parameter identification windings deformation on-line monitoring least square equivalent circuit equation
下载PDF
上一页 1 2 128 下一页 到第
使用帮助 返回顶部