In conjunction with the working characteristics of the high-clearance wheeled sprayer and the benefits of the closed hydraulic system,a series of reasonable working parameters should be established,and a hydraulic sys...In conjunction with the working characteristics of the high-clearance wheeled sprayer and the benefits of the closed hydraulic system,a series of reasonable working parameters should be established,and a hydraulic system that fulfills the requisite specifications should be designed.The AMESim software model is employed to construct a closed hydraulic transmission system,and the simulation analysis is then performed according to the data of hydraulic components.According to analysis results,the prototype can be optimized and upgraded,and a verification test is further carried out.The test results demonstrate that the designed closed hydraulic transmission system meets the actual working requirements of the high-clearance wheeled sprayer and provides a stable experimental platform for intelligent control of agricultural machinery.展开更多
This paper presents the results of a comparative investigation into the effects of the ignition method on the ballistic properties of a single-base gun propellant,as determined via closed vessel tests.Conventional gun...This paper presents the results of a comparative investigation into the effects of the ignition method on the ballistic properties of a single-base gun propellant,as determined via closed vessel tests.Conventional gunpowder ignition and plasma jet ignition methods were used,and differences in the ignition time were analysed.The influence of the ignition method on the dynamic vivacity is discussed.It is shown that this influence is significant in the first phase of the combustion process,and with respect to the low values of the loading density.In the second phase of the combustion process,and for large values of the loading density,the dynamic vivacity plots for the two ignition methods converge.Regarding the burning law,close values of the exponent were obtained for the two ignition methods.The dynamic vivacity plots determined for plasma ignition reveal stronger dependence on the loading density than those determined for gunpowder ignition.The conclusion is that plasma ignition is not a solution to the problems inherent to the process of determining the ballistic properties of propellants,which results in deviation of the burning process from the geometric burning law.展开更多
A general method has been developed for analyzing pressure buildup data from a well located in a system with both production and injection wells in a closed, bounded two-phase flow reservoir. The proposed method enabl...A general method has been developed for analyzing pressure buildup data from a well located in a system with both production and injection wells in a closed, bounded two-phase flow reservoir. The proposed method enables one to calculate the total mobility or permeability-thickness product, the skin factor, the average drainage-area pressure and the injection-production ratio (at the instant of shut-in) with accuracy from pressure buildup (or falloff) data dominated by a linear trend of reservoir pressure. Out of thousands of well tests, several typical field examples have been presented to illustrate the application of the proposed method for analyzing pressure transient data from a well located in a water-injection multiwell reservoir. And the possible application of this method to heterogeneous systems such as naturally fractured reservoirs is also discussed. Approaches to aid practicing engineers in verifying the buildup interpretation (or recognizing the interference of offset wells) are presented. Extension of the presented method to a gas well located in a multiwell gas reservoir is also suggested展开更多
In order to provide a novel and more effective alternative to the commonly used relay protection testing device that outputs only the sinusoidal testing signals, the concept of fault waveform regenerator is proposed i...In order to provide a novel and more effective alternative to the commonly used relay protection testing device that outputs only the sinusoidal testing signals, the concept of fault waveform regenerator is proposed in this paper, together with its hardware structure and software flow chart. Fault waveform regenerator mainly depends on its power amplifiers (PAs) to regenerate the fault waveforms recorded by digital fault recorder (DFR). To counteract the PA’s inherent nonlinear distortions, a digital closed-loop modification technique that is different from the predistortion technique is conceived. And the experimental results verify the effectiveness of the fault waveform regenerator based on the digital closed-loop modification technique.展开更多
基金Supported by 2023 Xinjiang Uygur Autonomous Region R&D and Promotion and Application of Key Technologies of CNC Sprayer for Seed Corn(2023NC010).
文摘In conjunction with the working characteristics of the high-clearance wheeled sprayer and the benefits of the closed hydraulic system,a series of reasonable working parameters should be established,and a hydraulic system that fulfills the requisite specifications should be designed.The AMESim software model is employed to construct a closed hydraulic transmission system,and the simulation analysis is then performed according to the data of hydraulic components.According to analysis results,the prototype can be optimized and upgraded,and a verification test is further carried out.The test results demonstrate that the designed closed hydraulic transmission system meets the actual working requirements of the high-clearance wheeled sprayer and provides a stable experimental platform for intelligent control of agricultural machinery.
基金supported by the National Research Centre,Poland [grant number DOB-BIO8/05/01/2016]the Ministry of Defence of Poland [grant number GBMON/13-988/2018/WAT]
文摘This paper presents the results of a comparative investigation into the effects of the ignition method on the ballistic properties of a single-base gun propellant,as determined via closed vessel tests.Conventional gunpowder ignition and plasma jet ignition methods were used,and differences in the ignition time were analysed.The influence of the ignition method on the dynamic vivacity is discussed.It is shown that this influence is significant in the first phase of the combustion process,and with respect to the low values of the loading density.In the second phase of the combustion process,and for large values of the loading density,the dynamic vivacity plots for the two ignition methods converge.Regarding the burning law,close values of the exponent were obtained for the two ignition methods.The dynamic vivacity plots determined for plasma ignition reveal stronger dependence on the loading density than those determined for gunpowder ignition.The conclusion is that plasma ignition is not a solution to the problems inherent to the process of determining the ballistic properties of propellants,which results in deviation of the burning process from the geometric burning law.
文摘A general method has been developed for analyzing pressure buildup data from a well located in a system with both production and injection wells in a closed, bounded two-phase flow reservoir. The proposed method enables one to calculate the total mobility or permeability-thickness product, the skin factor, the average drainage-area pressure and the injection-production ratio (at the instant of shut-in) with accuracy from pressure buildup (or falloff) data dominated by a linear trend of reservoir pressure. Out of thousands of well tests, several typical field examples have been presented to illustrate the application of the proposed method for analyzing pressure transient data from a well located in a water-injection multiwell reservoir. And the possible application of this method to heterogeneous systems such as naturally fractured reservoirs is also discussed. Approaches to aid practicing engineers in verifying the buildup interpretation (or recognizing the interference of offset wells) are presented. Extension of the presented method to a gas well located in a multiwell gas reservoir is also suggested
文摘In order to provide a novel and more effective alternative to the commonly used relay protection testing device that outputs only the sinusoidal testing signals, the concept of fault waveform regenerator is proposed in this paper, together with its hardware structure and software flow chart. Fault waveform regenerator mainly depends on its power amplifiers (PAs) to regenerate the fault waveforms recorded by digital fault recorder (DFR). To counteract the PA’s inherent nonlinear distortions, a digital closed-loop modification technique that is different from the predistortion technique is conceived. And the experimental results verify the effectiveness of the fault waveform regenerator based on the digital closed-loop modification technique.