期刊文献+
共找到210篇文章
< 1 2 11 >
每页显示 20 50 100
Study on Coaxiality Measurement System of Compound Gear Shaft Based on Non⁃contact Optic 被引量:2
1
作者 YE Zhibin LU Yonghua +2 位作者 TAN Jie LI Yanlong CHAI Zhong 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2021年第3期393-403,共11页
Aiming at the shortcomings of traditional contact measurement methods such as low measurement efficiency,high cost and low accuracy,a non-contact optical measurement method based on the laser displacement sensor is pr... Aiming at the shortcomings of traditional contact measurement methods such as low measurement efficiency,high cost and low accuracy,a non-contact optical measurement method based on the laser displacement sensor is proposed.According to the relevant regulations of the coaxiality error evaluation standard and the structural characteristics of the compound gear shaft,we have designed and built a set of supporting software system as well as a hardware test platform.In this paper,the distance difference threshold and scale threshold methods are used to eliminate outlier data.The least squares circle is selected to calculate the center of the circle and the minimum containment cylinder axis method is used as the reference axis of the composite gear shaft.Compensated by the standard step shaft calibration,the coaxiality error of the composite gear shaft can be measured to be within 0.01 mm in less than two minutes.The range value of the multi-section measurement test is 0.065 mm.The average coaxiality error is∅0.476 mm. 展开更多
关键词 compound gear shaft non-contact measurement laser displacement sensor coaxiality measuring system
下载PDF
Effect of low-speed waterjet pressure on the rock-breaking performance of unsubmerged cavitating abrasive waterjet
2
作者 Chen-Xing Fan Deng Li +1 位作者 Yong Kang Hai-Tao Zhang 《Petroleum Science》 SCIE EI CAS CSCD 2024年第4期2638-2649,共12页
Unsubmerged cavitating abrasive waterjet(UCAWJ)has been shown to artificially create a submerged environment that produces shear cavitation,which effectively enhances rock-breaking performance.The shear cavitation gen... Unsubmerged cavitating abrasive waterjet(UCAWJ)has been shown to artificially create a submerged environment that produces shear cavitation,which effectively enhances rock-breaking performance.The shear cavitation generation and collapse intensity depend on the pressure difference between the intermediate high-speed abrasive waterjet and the coaxial low-speed waterjet.However,the effect of the pressure of the coaxial low-speed waterjet is pending.For this purpose,the effect of low-speed waterjet pressure on rock-breaking performance at different standoff distances was experimentally investigated,and the effects of erosion time and ruby nozzle diameter on erosion performance were discussed.Finally,the micromorphology of the sandstone was observed at different locations.The results show that increased erosion time and ruby nozzle diameter can significantly improve the rock-breaking performance.At different standoff distances,the mass loss increases first and then decreases with the increase of low-speed waterjet pressure,the maximum mass loss is 10.4 g at a low-speed waterjet pressure of0.09 MPa.The surface morphology of cavitation erosion was measured using a 3D profiler,the increase in both erosion depth and surface roughness indicated a significant increase in the intensity of the shear cavitation collapse.At a low-speed waterjet pressure of 0.18 MPa,the cavitation erosion surface depth can reach 600μm with a roughness of 127μm. 展开更多
关键词 Rock-breaking Coaxial low-speed waterjet pressure Abrasive waterjet CAVITATION Unsubmerged environment
下载PDF
Coaxial electrohydrodynamic printing of core–shell microfibrous scaffolds with layer-specific growth factors release for enthesis regeneration
3
作者 Lang Bai Meiguang Xu +10 位作者 Zijie Meng Zhennan Qiu Jintao Xiu Baojun Chen Qian Han Qiaonan Liu Pei He Nuanyang Wen Jiankang He Jing Zhang Zhanhai Yin 《International Journal of Extreme Manufacturing》 SCIE EI CAS CSCD 2024年第5期220-238,共19页
The rotator cuff tear has emerged as a significant global health concern.However,existing therapies fail to fully restore the intricate bone-to-tendon gradients,resulting in compromised biomechanical functionalities o... The rotator cuff tear has emerged as a significant global health concern.However,existing therapies fail to fully restore the intricate bone-to-tendon gradients,resulting in compromised biomechanical functionalities of the reconstructed enthesis tissues.Herein,a tri-layered core–shell microfibrous scaffold with layer-specific growth factors(GFs)release is developed using coaxial electrohydrodynamic(EHD)printing for in situ cell recruitment and differentiation to facilitate gradient enthesis tissue repair.Stromal cell-derived factor-1(SDF-1)is loaded in the shell,while basic fibroblast GF,transforming GF-beta,and bone morphogenetic protein-2 are loaded in the core of the EHD-printed microfibrous scaffolds in a layer-specific manner.Correspondingly,the tri-layered microfibrous scaffolds have a core–shell fiber size of(25.7±5.1)μm,with a pore size sequentially increasing from(81.5±4.6)μm to(173.3±6.9)μm,and to(388.9±6.9μm)for the tenogenic,chondrogenic,and osteogenic instructive layers.A rapid release of embedded GFs is observed within the first 2 d,followed by a faster release of SDF-1 and a slightly slower release of differentiation GFs for approximately four weeks.The coaxial EHD-printed microfibrous scaffolds significantly promote stem cell recruitment and direct their differentiation toward tenocyte,chondrocyte,and osteocyte phenotypes in vitro.When implanted in vivo,the tri-layered core–shell microfibrous scaffolds rapidly restored the biomechanical functions and promoted enthesis tissue regeneration with native-like bone-to-tendon gradients.Our findings suggest that the microfibrous scaffolds with layer-specific GFs release may offer a promising clinical solution for enthesis regeneration. 展开更多
关键词 coaxial electrohydrodynamic printing core-shell structures microfibrous scaffolds growth factors enthesis regeneration
下载PDF
Coaxial Wet Spinning of Boron Nitride Nanosheet‑Based Composite Fibers with Enhanced Thermal Conductivity and Mechanical Strength
4
作者 Wenjiang Lu Qixuan Deng +3 位作者 Minsu Liu Baofu Ding Zhiyuan Xiong Ling Qiu 《Nano-Micro Letters》 SCIE EI CAS CSCD 2024年第2期126-138,共13页
Hexagonal boron nitride nanosheets(BNNSs)exhibit remarkable thermal and dielectric properties.However,their self-assembly and alignment in macroscopic forms remain challenging due to the chemical inertness of boron ni... Hexagonal boron nitride nanosheets(BNNSs)exhibit remarkable thermal and dielectric properties.However,their self-assembly and alignment in macroscopic forms remain challenging due to the chemical inertness of boron nitride,thereby limiting their performance in applications such as thermal management.In this study,we present a coaxial wet spinning approach for the fabrication of BNNSs/polymer composite fibers with high nanosheet orientation.The composite fibers were prepared using a superacid-based solvent system and showed a layered structure comprising an aramid core and an aramid/BNNSs sheath.Notably,the coaxial fibers exhibited significantly higher BNNSs alignment compared to uniaxial aramid/BNNSs fibers,primarily due to the additional compressive forces exerted at the core-sheath interface during the hot drawing process.With a BNNSs loading of 60 wt%,the resulting coaxial fibers showed exceptional properties,including an ultrahigh Herman orientation parameter of 0.81,thermal conductivity of 17.2 W m^(-1)K^(-1),and tensile strength of 192.5 MPa.These results surpassed those of uniaxial fibers and previously reported BNNSs composite fibers,making them highly suitable for applications such as wearable thermal management textiles.Our findings present a promising strategy for fabricating high-performance composite fibers based on BNNSs. 展开更多
关键词 Boron nitride nanosheets Coaxial fiber Interfacial compression Nanosheet aligning Wearable thermal management
下载PDF
Experimental study on temperature fluctuations on plate surface induced by coaxial-jet flow
5
作者 Xue-Yao Xiong Zun-Quan Liu +2 位作者 Guo-Yan Zhou Xing Luo Shan-Tung Tu 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第5期139-153,共15页
In nuclear reactors,temperature fluctuations of fluids may cause fatigue damage to adjacent structures;this is referred to as thermal striping.Research on thermal striping in the upper plenum has mainly focused on flu... In nuclear reactors,temperature fluctuations of fluids may cause fatigue damage to adjacent structures;this is referred to as thermal striping.Research on thermal striping in the upper plenum has mainly focused on fluid fields.Few experimental studies have been reported on solid structures in a fluid field with a coaxial jet.This study entailed an experimental study of the temperature fluctuations in the fluid and on a plate surface caused by a coaxial jet.The temperature fluctuations of the fluid and plate surfaces located at different heights were analyzed.The cause of the temperature fluctuation was analyzed using a transient temperature distribution.The results show that the mixing of the hot and cold fluids gradually becomes uniform in the positive axial direction.The average surface temperatures tended to be consistent.When the jet reaches the plate surface,the swing of the jet center,contraction and expansion of the cold jet,and changes in the jet shape result in temperature fluctuations.The intensity of the temperature fluctuation was affected by the position.More attention should be paid when the plate is located at a lower height,and between the hot and cold-fluid nozzles. 展开更多
关键词 Temperature fluctuation Thermal striping Coaxial jet Thermal mixing The upper plenum of nuclear reactor
下载PDF
Study of plasma parameters of coaxial plasma source using triple Langmuir probe and Faraday cup diagnostics
6
作者 Sunil KANCHI Rohit SHUKLA Archana SHARMA 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第4期94-100,共7页
Coaxial plasma guns are a type of plasma source that produces plasma which propagates radially and axially controlled by the shape of the ground electrode, which has attracted much interest in several applications. In... Coaxial plasma guns are a type of plasma source that produces plasma which propagates radially and axially controlled by the shape of the ground electrode, which has attracted much interest in several applications. In this work, a 120° opening angle of CPG nozzle is used as a plasma gun configuration that operates at the energy of 150 J. The ionization of polyethylene insulator between the electrodes of the gun produces a cloud of hydrogen and carbon plasma.The triple Langmuir probe and Faraday cup are used to measure plasma density and plasma temperature. These methods are used to measure the on-axis and off-axis plasma divergence of the coaxial plasma gun. The peak values of ion densities measured at a distance of 25 mm on-axis from the plasma gun are(1.6±0.5)×10^(19)m^(-3)and(2.8±0.6)×10^(19)m^(-3)for hydrogen and carbon plasma respectively and the peak temperature is 3.02±0.5 eV. The mean propagation velocity of plasma is calculated using the transit times of plasma at different distances from the plasma gun and is found to be 4.54±0.25 cm/μs and 1.81±0.18 cm/μs for hydrogen and carbon plasma respectively. The Debye radius is obtained from the measured experimental data that satisfies the thin sheath approximation. The shot-to-shot stability of plasma parameters facilitates the use of plasma guns in laboratory experiments. These types of plasma sources can be used in many applications like plasma opening switches, plasma devices, and as plasma sources. 展开更多
关键词 coaxial plasma source triple Langmuir probe Faraday cup plasma density plasma temperature
下载PDF
Numerical Simulation of Droplet Generation in Coaxial Microchannels
7
作者 Zongjun Yin Rong Su Hui Xu 《Fluid Dynamics & Materials Processing》 EI 2024年第3期487-504,共18页
In this study,numerical simulations of the pinching-off phenomena displayed by the dispersed phase in a continuous phase have been conducted using COMSOL Multiphysics(level-set method).Four flow patterns,namely“drop ... In this study,numerical simulations of the pinching-off phenomena displayed by the dispersed phase in a continuous phase have been conducted using COMSOL Multiphysics(level-set method).Four flow patterns,namely“drop flow”,“jet flow”,“squeeze flow”,and“co-flow”,have been obtained for different flow velocity ratios,channel diameter ratios,density ratios,viscosity ratios,and surface tension.The flow pattern map of two-phase flow in coaxial microchannels has been obtained accordingly,and the associated droplet generation process has been critically discussed considering the related frequency,diameter,and pinch-off length.In particular,it is shown that the larger the flow velocity ratio,the smaller the diameter of generated droplets and the shorter the pinch-off length.The pinch-off length of a droplet is influenced by the channel diameter ratio and density ratio.The changes in viscosity ratio have a negligible influence on the droplet generation pinching frequency.With an increase in surface tension,the frequency of generation and pinch-off length of droplets decrease,but for small surface tension the generation diameter of droplet increases. 展开更多
关键词 Droplet generation characteristics coaxial microchannels flow patterns pinch-off length
下载PDF
Percutaneous ultrasound-guided coaxial core needle biopsy for the diagnosis of multiple splenic lesions: A case report
8
作者 Sha-Hong Pu Wu-Yong-Ga Bao +2 位作者 Zhen-Peng Jiang Rui Yang Qiang Lu 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第2期616-621,共6页
BACKGROUND The overlap of imaging manifestations among distinct splenic lesions gives rise to a diagnostic dilemma.Consequently,a definitive diagnosis primarily relies on his-tological results.The ultrasound(US)-guide... BACKGROUND The overlap of imaging manifestations among distinct splenic lesions gives rise to a diagnostic dilemma.Consequently,a definitive diagnosis primarily relies on his-tological results.The ultrasound(US)-guided coaxial core needle biopsy(CNB)not only procures sufficient tissue to help clarify the diagnosis,but reduces the incidence of puncture-related complications.CASE SUMMARY A 41-year-old female,with a history of pulmonary tuberculosis,was admitted to our hospital with multiple indeterminate splenic lesions.Gray-scale ultrasono-graphy demonstrated splenomegaly with numerous well-defined hypoechoic ma-sses.Abdominal contrast-enhanced computed tomography(CT)showed an en-larged spleen with multiple irregular-shaped,peripherally enhancing,hypodense lesions.Positron emission CT revealed numerous abnormal hyperglycemia foci.These imaging findings strongly indicated the possibility of infectious disease as the primary concern,with neoplastic lesions requiring exclusion.To obtain the precise pathological diagnosis,the US-guided coaxial CNB of the spleen was ca-rried out.The patient did not express any discomfort during the procedure.CONCLUSION Percutaneous US-guided coaxial CNB is an excellent and safe option for obtaining precise splenic tissue samples,as it significantly enhances sample yield for exact pathological analysis with minimum trauma to the spleen parenchyma and sur-rounding tissue. 展开更多
关键词 SPLEEN Splenic disease Ultrasound BIOPSY Ultrasound-guided coaxial core needle biopsy Case report
下载PDF
Dynamical Modeling and Dynamic Characteristics Analysisof a Coaxial Dual-Rotor System
9
作者 Yubin Yue Hongjun Wang Shenglun Zhang 《Journal of Dynamics, Monitoring and Diagnostics》 2024年第2期99-111,共13页
The dual-rotor structure serves as the primary source of vibration in aero-engines. Understanding itsdynamical model and analyzing dynamic characteristics, such as critical speed and unbalanced response, arecrucial fo... The dual-rotor structure serves as the primary source of vibration in aero-engines. Understanding itsdynamical model and analyzing dynamic characteristics, such as critical speed and unbalanced response, arecrucial for rotor system dynamics. Previous work introduced a coaxial dual-rotor-support scheme for aeroengines,and a physical model featuring a high-speed flexible inner rotor with a substantial length-to-diameter ratiowas designed. Then a finite element (FE) dynamic model based on the Timoshenko beam elements and rigid bodykinematics of the dual-rotor system is modeled, with the Newmark method and Newton–Raphson method used forthe numerical calculation to study the dynamic characteristics of the system. Three different simulation models,including beam-based FE (1D) model, solid-based FE (3D) model, and transfer matrix model, were designed tostudy the characteristics of mode and the critical speed characteristic of the dual-rotor system. The unbalancedresponse of the dual-rotor system was analyzed to study the influence of mass unbalance on the rotor system. Theeffect of different disk unbalance phases and different speed ratios on the dynamic characteristics of the dual-rotorsystem was investigated in detail. The experimental result shows that the beam-based FE model is effective andsuitable for studying the dual-rotor system. 展开更多
关键词 coaxial dual-rotor system dynamical modeling dynamic characteristics analysis rotor dynamics
下载PDF
Comparison between the SAPIEN S3 and the SAPIEN XT transcatheter heart valves:A single-center experience 被引量:2
10
作者 Fadi J Sawaya Marco Spaziano +9 位作者 Thierry Lefèvre Andrew Roy Phillippe Garot Thomas Hovasse Antoinette Neylon Hakim Benamer Mauro Romano Thierry Unterseeh Marie-Claude Morice Bernard Chevalier 《World Journal of Cardiology》 2016年第12期735-745,共11页
AIM To investigate the clinical outcomes of transcatheter aortic valve implantation(TAVI) with the SAPIEN 3 transcatheter heart valve(S3-THV) vs the SAPIEN XT valve(XT-THV).METHODS We retrospectively analyzed 507 pati... AIM To investigate the clinical outcomes of transcatheter aortic valve implantation(TAVI) with the SAPIEN 3 transcatheter heart valve(S3-THV) vs the SAPIEN XT valve(XT-THV).METHODS We retrospectively analyzed 507 patients that underwent TAVI with the XT-THV and 283 patients that received the S3-THV at our institution between March 2010 and December 2015.RESULTS Thirty-day mortality(3.5% vs 8.7%:OR=0.44,P=0.21) and 1-year mortality(25.7% vs 20.1%,P=0.55) were similar in the S3-THV and the XT-THV groups.The rates of both major vascular complication and paravalvular regurgitation(PVR)>1 were almost 4 times lower in the S3-THV group than the XT-THV group(major vascular complication: 2.8% vs 9.9%,P<0.0001:PVR>1: 2.4% vs 9.7%,P<0.0001).However,the rate of new pacemaker implantation was almost twice as high in the S3-THV group(17.3% vs 9.8%,P=0.03).In the S3 group,independent predictors of new permanent pacemaker were pre-procedural RBBB(OR=4.9:P=0.001),pre-procedural PR duration(OR=1.14,P=0.05) and device lack of coaxiality(OR=1.13:P=0.05) during deployment.CONCLUSION The S3-THV is associated to lower rates of major vascular complications and PVR but higher rates of new pacemaker compared to the XT-THV.Sub-optimal visualization of the S3-THV in relation to the aortic valvular complex during deployment is a predictor of new permanent pacemaker. 展开更多
关键词 SAPIEN-3 valve Vascular complications Permanent pacemaker Lack of coaxiality Paravalvular regurgitation
下载PDF
Development and Application of a Surface High-pressure Injection Device Using a Submersible Electric Pump
11
作者 Li Baoyan Tian Xin +1 位作者 Wang Yong Han Shaoming 《Petroleum Science》 SCIE CAS CSCD 2005年第3期24-27,共4页
Injection recovery is an important measure for increasing the oil recovery rate of an oil field. One way is that centrifugal pumps or plunger pumps are used in an injection station to responsible for injection over a ... Injection recovery is an important measure for increasing the oil recovery rate of an oil field. One way is that centrifugal pumps or plunger pumps are used in an injection station to responsible for injection over a large area under the same pressure. This method is ineffective for low-permeability layers. For the oilfields in dispersed distribution in the marginal areas of Daqing, the low water-absorbing section needs an injection with a high delivery pressure and a low discharge capacity; another way is to install the submersible electric pump upside down, but because the submersible electric pump and the motor are underground, it is difficult for installation and maintenance. Introduced in this paper is the development and application of a surface high-pressure injection device with a submersible electric pump. Bysuccessful resolving some problems, such as the axial force of the submersible electric pump, sealing, level regulation of the pump, coaxiality and vibration, the device has the good points of running smoothly, moving easily, installation and maintains quickly and long period of running. This device can effectively solve the injection of the low water-absorbing section and of oilfields in dispersed locations. The recovery rate of oilfields is also enhanced. 展开更多
关键词 Submersible electric pump surface high-pressure injection axial force SEALING coaxiality
下载PDF
Electrospun nanofibers as a wound dressing for treating diabetic foot ulcer 被引量:14
12
作者 Yan Liu Shiya Zhou +1 位作者 Yanlin Gao Yinglei Zhai 《Asian Journal of Pharmaceutical Sciences》 SCIE CAS 2019年第2期130-143,共14页
Diabetes is one of the most prevalent diseases in the world with high-mortality and complex complications including diabetic foot ulcer(DFU). It has been reported that the difficulties in repairing the wound related t... Diabetes is one of the most prevalent diseases in the world with high-mortality and complex complications including diabetic foot ulcer(DFU). It has been reported that the difficulties in repairing the wound related to DFU has much relationship with the wound infection,change of inflammatory responses, lack of extracellular matrix(ECM), and the failure of angiogenesis. Following the development of medical materials and pharmaceutical technology, nanofibers has been developed by electrospinning with huge porosity, excellent humidity absorption, a better oxygen exchange rate, and some antibacterial activities. That is to say, as a potential material, nanofibers must be a wonderful candidate for the DFU treatment with so many benefits. Careful selection of polymers from natural resource and synthetic resource can widen the nanofibrous application. Popular methods applied for the nanofibrous fabrication consist of uniaxial electrospinning and coaxial electrospinning. Furthermore, nanofibers loading chemical, biochemical active pharmaceutical ingredient(API)or even stem cells can be wonderful dosage forms for the treatment of DFU. This review summarizes the present techniques applied in the fabrication of nanofibrous dressing(ND)that utilizes a variety of materials and active agents to offer a better health care for the patients suffering from DFU. 展开更多
关键词 NANOFIBERS Nanofibrous DRESSING DIABETIC foot ULCER UNIAXIAL ELECTROSPINNING Coaxial ELECTROSPINNING
下载PDF
Outcomes of 1.8-3.0 mm incision phacoemulsification combined with trabeculectomy for primary angle-closure glaucoma with cataract 被引量:10
13
作者 Qing Wang Zheng-Xuan Jiang Rong-Feng Liao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第2期246-251,共6页
●AIM:To compare efficacy of coaxial microincisions(1.8 mm,2.2 mm)and small incisions(3.0 mm)on phacoemulsification combined with trabeculectomy for primary angle-closure glaucoma(PACG)with cataract.●METHODS:Ninety-s... ●AIM:To compare efficacy of coaxial microincisions(1.8 mm,2.2 mm)and small incisions(3.0 mm)on phacoemulsification combined with trabeculectomy for primary angle-closure glaucoma(PACG)with cataract.●METHODS:Ninety-six patients(96 eyes)with PACG and cataract were recruited and randomly divided into three groups between January 2015 and June 2017.Group A(3.0 mm incision),B(2.2 mm incision),and C(1.8 mm incision)comprised 30,34 and 32 eyes respectively.All cases were treated with clear corneal incision phacoemulsification combined with trabeculectomy.Data including best corrected visual acuity(BCVA),corneal astigmatism,corneal endothelial cell counts(CECC),intraocular pressure(IOP),and complications were collected before the operation,and at postoperative 1 d,1 and 3 mo.●RESULTS:All the patients were successfully treated with surgery.The BCVA of groups B and C were significantly improved as compared to group A at postoperative 1 d,1 and 3 mo(all P<0.05),but there was no difference between groups B and C at each time interval(all P>0.05).The corneal astigmatism of group A was statistically higher than that of group B(P=0.026);corneal astigmatism of group B was statistically higher than that of group C at postoperative 1 d(P=0.006).The corneal astigmatism of group A at postoperative 3 mo was significantly higher than that before operation(P=0.003).At postoperative 1 and 3 mo,corneal astigmatism of groups B and C were significantly lower than that of group A(all P<0.05).The CECC in group B was significantly higher than that of group A(P=0.020),and CECC in group C was significantly higher than that of group B(P=0.034)at postoperative 1 d.At postoperative 1 and 3 mo,CECC of groups B and C were significantly higher than that of group A(all P<0.05).In each group,postoperative mean IOP at each time interval was significantly lower than preoperative IOP(all P<0.05).●CONCLUSION:Coaxial microincision phacoemulsification combined with trabeculectomy for PACG with cataract has better curative efficacy in reducing postoperative corneal astigmatism and corneal endothelial cell injury than traditional small incision combined surgery,and the 1.8 mm microincision has better curative efficacy than 2.2 mm microincision in the early postoperative period. 展开更多
关键词 coaxial MICROINCISION GLAUCOMA CATARACT PHACOEMULSIFICATION TRABECULECTOMY
下载PDF
Flexible,Highly Thermally Conductive and Electrically Insulating Phase Change Materials for Advanced Thermal Management of 5G Base Stations and Thermoelectric Generators 被引量:9
14
作者 Ying Lin Qi Kang +4 位作者 Yijie Liu Yingke Zhu Pingkai Jiang Yiu‑Wing Mai Xingyi Huang 《Nano-Micro Letters》 SCIE EI CAS CSCD 2023年第3期1-15,共15页
Thermal management has become a crucial problem for high-power-density equipment and devices.Phase change materials(PCMs)have great prospects in thermal management applications because of their large capacity of heat ... Thermal management has become a crucial problem for high-power-density equipment and devices.Phase change materials(PCMs)have great prospects in thermal management applications because of their large capacity of heat storage and isothermal behavior during phase transition.However,low intrinsic thermal conductivity,ease of leakage,and lack of flexibility severely limit their applications.Solving one of these problems often comes at the expense of other performance of the PCMs.In this work,we report core–sheath structured phase change nanocomposites(PCNs)with an aligned and interconnected boron nitride nanosheet network by combining coaxial electrospinning,electrostatic spraying,and hot-pressing.The advanced PCN films exhibit an ultrahigh thermal conductivity of 28.3 W m^(-1)K^(-1)at a low BNNS loading(i.e.,32 wt%),which thereby endows the PCNs with high enthalpy(>101 J g^(-1)),outstanding ductility(>40%)and improved fire retardancy.Therefore,our core–sheath strategies successfully balance the trade-off between thermal conductivity,flexibility,and phase change enthalpy of PCMs.Further,the PCNs provide powerful cooling solutions on 5G base station chips and thermoelectric generators,displaying promising thermal management applications on high-power-density equipment and thermoelectric conversion devices. 展开更多
关键词 Coaxial electrospinning Boron nitride nanosheets Phase change nanocomposites Thermal conductivity Thermal management
下载PDF
Temperature‑Arousing Self‑Powered Fire Warning E‑Textile Based on p-n Segment Coaxial Aerogel Fibers for Active Fire Protection in Firefighting Clothing 被引量:7
15
作者 Hualing He Yi Qin +6 位作者 Zhenyu Zhu Qing Jiang Shengnan Ouyang Yuhang Wan Xueru Qu Jie Xu Zhicai Yu 《Nano-Micro Letters》 SCIE EI CAS CSCD 2023年第12期141-160,共20页
Firefighting protective clothing is a crucial protective equipment for firefighters to minimize skin burn and ensure safety firefighting operation and rescue mission.A recent increasing concern is to develop self-powe... Firefighting protective clothing is a crucial protective equipment for firefighters to minimize skin burn and ensure safety firefighting operation and rescue mission.A recent increasing concern is to develop self-powered fire warning materials that can be incorporated into the firefighting clothing to achieve active fire protection for firefighters before the protective clothing catches fire on fireground.However,it is still a challenge to facilely design and manufacture thermoelectric(TE)textile(TET)-based fire warning electronics with dynamic surface conformability and breathability.Here,we develop an alternate coaxial wet-spinning strategy to continuously produce alternating p/n-type TE aerogel fibers involving n-type Ti_(3)C_(2)T_(x)MXene and p-type MXene/SWCNT-COOH as core materials,and tough aramid nanofiber as protective shell,which simultaneously ensure the flexibility and high-efficiency TE power generation.With such alternating p/n-type TE fibers,TET-based self-powered fire warning sensors with high mechanical stability and wearability are successfully fabricated through stitching the alternating p-n segment TE fibers into aramid fabric.The results indicate that TET-based fire warning electronics containing 50 p-n pairs produce the open-circuit voltage of 7.5 mV with a power density of 119.79 nW cm-2 at a temperature difference of 300℃.The output voltage signal is then calculated as corresponding surface temperature of firefighting clothing based on a linear relationship between TE voltage and temperature.The fire alarm response time and flame-retardant properties are further displayed.Such self-powered fire warning electronics are true textiles that offer breathability and compatibility with body movement,demonstrating their potential application in firefighting clothing. 展开更多
关键词 Self-powered fire warning Coaxial wet spinning P-n segment thermoelectric fiber Thermoelectric textiles Active fire protection
下载PDF
Research on a combinatorial control method for coaxial rotor aircraft based on sliding mode 被引量:5
16
作者 Yi-ran Wei Hong-bin Deng +2 位作者 Zhen-hua Pan Ke-wei Li Han Chen 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2022年第2期280-292,共13页
Aiming at the position and attitude tracking of coaxial rotor aircraft(CRA),this paper proposes a combinatorial control method of sliding mode control(SMC)coupled with proportional-integralderivative control(PIDC).Con... Aiming at the position and attitude tracking of coaxial rotor aircraft(CRA),this paper proposes a combinatorial control method of sliding mode control(SMC)coupled with proportional-integralderivative control(PIDC).Considering the complete description of flight dynamics,aerodynamics and airflow interference,the dynamical model of CRA is established.The dynamical model is simplified according to the actual flight,then the simplified dynamical model is divided into two subsystems:a fully-actuated subsystem and an under-actuated subsystem.The controller of the fully-actuated subsystem consists of a SMC controller coupled with a rate bounded PIDC controller,while the controller of the under-actuated subsystem is composed of a SMC controller.The sliding manifold is defined by combining the position and velocity tracking errors of the state variables for each subsystem.Lyapunov stability theory is used to verify the stability of the sliding mode controller,which ensures that all state trajectories of the system can reach and stay on the sliding mode surface,the uncertainty and external interference of the model are compensated.Simulation and experiment compared with the conventional PIDC are carried out,the results demonstrate the effectiveness and the robustness of the proposed control method of this paper. 展开更多
关键词 Coaxial rotor aircraft Sliding mode control Position and attitude tracking Simulation Experiment
下载PDF
Power consumption and flow field characteristics of a coaxial mixer with a double inner impeller 被引量:4
17
作者 刘宝庆 张义堃 +2 位作者 陈明强 厉鹏 金志江 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2015年第1期1-6,共6页
A coaxial mixer meeting the actual demand of a system with high and variable viscosity is investigated. It has an outer wall-scraping frame and a double inner impeller consisting of a four-pitched-blade turbine and Ru... A coaxial mixer meeting the actual demand of a system with high and variable viscosity is investigated. It has an outer wall-scraping frame and a double inner impeller consisting of a four-pitched-blade turbine and Rushton turbine. The power consumption and flow field characteristics of the coaxial mixer in laminar and transitional flow are simulated numerically, and then the distribution of velocity field, shear rate and mass flow rate are analyzed. The simulation results indicate that the outer frame has little effect on the power consumption of the double inner impeller whether in laminar or transitional flow, whereas the inner combined impeller has a great effect on the power consumption of the outer frame. Compared with the single rotation mode, the power consumption of the outer frame will decrease in co-rotation mode and increase in counter-rotation mode. The velocity, shear rate and mass flow rate are relatively high near the inner impeller in all operating modes, and only under double-shaft agitation will the mixing performance near the free surface be improved.In addition, these distributions in the co-rotation and counter-rotation modes show little difference, but the co-rotation mode is recommended for the advantage of low power consumption. 展开更多
关键词 Coaxial mixer Power consumption Flow field characteristics Numerical simulation
下载PDF
Investigation on discharge characteristics of a coaxial dielectric barrier discharge reactor driven by AC and ns power sources 被引量:7
18
作者 Qian WANG Feng LIU +2 位作者 Chuanrun MIAO Bing YAN Zhi FANG 《Plasma Science and Technology》 SCIE EI CAS CSCD 2018年第3期78-86,共9页
A coaxial dielectric barrier discharge(DBD) reactor with double layer dielectric barriers has been developed for exhaust gas treatment and excited either by AC power or nanosecond(ns)pulse to generate atmospheric ... A coaxial dielectric barrier discharge(DBD) reactor with double layer dielectric barriers has been developed for exhaust gas treatment and excited either by AC power or nanosecond(ns)pulse to generate atmospheric pressure plasma. The comparative study on the discharge characteristics of the discharge uniformity, power deposition, energy efficiency, and operation temperature between AC and ns pulsed coaxial DBD is carried out in terms of optical and electrical characteristics and operation temperature for optimizing the coaxial DBD reactor performance. The voltages across the air gap and dielectric layer and the conduction and displacement currents are extracted from the applied voltages and measured currents of AC and ns pulsed coaxial DBDs for the calculation of the power depositions and energy efficiencies through an equivalent electrical model. The discharge uniformity and operating temperature of the coaxial DBD reactor are monitored and analyzed by optical images and infrared camera. A heat conduction model is used to calculate the temperature of the internal quartz tube. It is found that the ns pulsed coaxial DBD has a much higher instantaneous power deposition in plasma, a lower total power consumption, and a higher energy efficiency compared with that excited by AC power and is more homogeneous and stable. The temperature of the outside wall of the AC and ns pulse excited coaxial DBD reaches 158 ℃ and 64.3 ℃ after 900 s operation, respectively.The experimental results on the comparison of the discharge characteristics of coaxial DBDs excited by different powers are significant for understanding of the mechanism of DBDs,reducing energy loss, and optimizing the performance of coaxial DBD in industrial applications. 展开更多
关键词 coaxial dielectric barrier discharge discharge characteristics nanosecond pulse operation temperature
下载PDF
Detection of Coaxial Backscattered Electrons in SEM 被引量:5
19
作者 JIANG Chang-zhong REN Da-zhi (Department of Physics, Wuhan University, Wuhan 430072, China) 《Wuhan University Journal of Natural Sciences》 CAS 2000年第1期41-44,共4页
We present a coaxial detection of the backscattered electrons in SEM. The lens-aperture has been used to filter in energy and focus the backscattered electrons. This particular geometry allows us to eliminate the low ... We present a coaxial detection of the backscattered electrons in SEM. The lens-aperture has been used to filter in energy and focus the backscattered electrons. This particular geometry allows us to eliminate the low energy backscattered electrons and collect the backscattered electrons, which are backscattered close to the incident beam orientation. The main advantage of this geometry is adapted to topographic contrast attenuation and atomic number contrast enhancement. Thus this new SEM is very suitable to analyze the material composition. 展开更多
关键词 scanning electron microscopy backscattered electrons coaxial detection
下载PDF
Corneal biomechanical properties changes after coaxial 2,2-mm microincision and standard 3,0-mm phacoemulsification 被引量:4
20
作者 Zhe Zhang Hua Yu +3 位作者 Hui Dong Li Wang Ya-Ding Jia Su-Hua Zhang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第2期230-234,共5页
AIM: To compare the changes in corneal biomechanics measured by ocular response analyzer (ORA) after 2.2-ram microincision cataract surgery and 3.0-mm standard coaxial phacoemulsification. METHODS: The prospectiv... AIM: To compare the changes in corneal biomechanics measured by ocular response analyzer (ORA) after 2.2-ram microincision cataract surgery and 3.0-mm standard coaxial phacoemulsification. METHODS: The prospective nonrandomized study comprised eyes with cataract that had 2.2-mm coaxial microincision or 3.0 -mm standard incision phacoemulsification. The corneal hysteresis (CH), corneal resistance factor (CRF), corneal-compensated intraocular pressure (IOPcc) and Goldmann-correlated intraocular pressure (IOPg) were measured by ORA preoperatively and at ld, 1-, 2-, 3- and 4-week postoperatively. Results were analyzed and compared between groups. RESULTS: In both groups, CH decreased in the immediate postoperative period (P〈0.05), returned to the preoperative level at one week (P =0.249) in the 2.2-mm group, and at two weeks in the 3.0-mm group (P --0.264); there was no significant change in CRF values. In 2.2-mm group, mean IOPcc and IOPg increased at ld postoperatively (both ,P〈0.05), and returned to preoperative level at one week (,0 =0.491 and P =0.923, respectively). In 3.0-mm group, mean IOPcc and IOPg increased at ld and lwk postoperatively (P =0.005 and ,P =0.029, respectively), and returned to preoperative level at 2wk (P =0.347 and P =0.887, respectively). CONCLUSION: Significant differences between preoperative and postoperative corneal biomechanical values were found for CH, IOPcc and IOPg. But the recovery time courses were different between the two groups. The 2.2-mm coaxial microincision cataract surgery group seemed recovery faster compared to the 3.0-mm standard coaxial phacoemulsification group. 展开更多
关键词 coaxial microincision cataract surgery 2.2-mm microincision corneal biomechanical parameters time course
下载PDF
上一页 1 2 11 下一页 到第
使用帮助 返回顶部