期刊文献+
共找到6,627篇文章
< 1 2 250 >
每页显示 20 50 100
Investigation of lacrimal sac space-occupying lesions using color doppler ultrasound, computed tomography, and computed tomography dacryocystography
1
作者 Zhen-Bin Qian Bo Yu +3 位作者 Ye Yang Wei Fang Jian-Li Dong Li-Qing Wei 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第8期1224-1230,共7页
AIM:To observe the imaging features of color Doppler ultrasound(CDU)and computed tomography(CT)or computed tomography dacryocystography(CT-DCG)in different types of lacrimal sac space-occupying lesions(SOLs).METHODS:T... AIM:To observe the imaging features of color Doppler ultrasound(CDU)and computed tomography(CT)or computed tomography dacryocystography(CT-DCG)in different types of lacrimal sac space-occupying lesions(SOLs).METHODS:This retrospective case series study included 21 patients with lacrimal sac SOLs who underwent lacrimal sac surgery between January 2018 and March 2022.The imaging features of CDU and CT or CT-DCG in these patients were extracted from the examination cloud system.The images were observed and analyzed.RESULTS:The detection rate of lacrimal SOLs between CDU(21/21,100%)and CT or CT-DCG(20/21,95.2%)had no statistically significant difference(P=1.0).CDU could detect the blood flow signals in all SOLs except mucocele and mucopeptide concretion.Among them,polyps had characteristic imaging changes on CDU and CT-DCG.The mucoceles and mucopeptide concretions had characteristic imaging changes on CDU,which could provide more information for differential diagnosis.CONCLUSION:The morphology and internal blood flow signals of lacrimal sac SOLs can be observed using CDU.CT or CT-DCG has advantages in observing structural damage around the lacrimal sac mass.Therefore,CDU may be used as a routine examination to exclude lacrimal sac SOLs before dacryocystorhinostomy in the absence of preoperative CT or CT-DCG. 展开更多
关键词 lacrimal sac computed tomography computed tomography dacryocystography color doppler ultrasound space-occupying lesions
下载PDF
Hemodynamic analysis of esophageal varices in patients with liver cirrhosis using color Doppler ultrasound 被引量:24
2
作者 Feng-Hua Li Jing Hao +2 位作者 Jian-Guo Xia Hong-Li Li Hua Fang 《World Journal of Gastroenterology》 SCIE CAS CSCD 2005年第29期4560-4565,共6页
AIM: To study the portal hemodynamics and their relationship with the size of esophageal varices seen at endoscopy and to evaluate whether these Doppler ultrasound parameters might predict variceal bleeding in patien... AIM: To study the portal hemodynamics and their relationship with the size of esophageal varices seen at endoscopy and to evaluate whether these Doppler ultrasound parameters might predict variceal bleeding in patients with liver cirrhosis and portal hypertension. METHODS: One hundred and twenty cirrhotic patients with esophageal varices but without any previous bleeding were enrolled in the prospective study. During a 2-year observation period, 52 patients who had at least one episode of acute esophageal variceal hemorrhage constituted the bleeding group, and the remaining 68 patients without any previous hemorrhage constituted the non-bleeding group. All patients underwent endoscopy before or after color Doppler-ultrasonic examination, and images were interpreted independently by two endoscopists. The control group consisted of 30 healthy subjects, matched to the patient group in age and gender. Measurements of diameter, flow direction and flow velocity in the left gastric vein (LGV) and the portal vein (PV) were done in all patients and controls using color Doppler unit. After baseline measurements, 30 min after oral administration of 75 g glucose in 225 mL, changes of the diameter, flow velocity and direction in the PV and LGV were examined in 60 patients with esophageal varices and 15 healthy controls. RESULTS: The PV and LGV were detected successfully in 115 (96%) and 105 (88%) of 120 cirrhotic patients, respectively, and in 27 (90%) and 21 (70%) of 30 healthy controls, respectively. Among the 120 cirrhotic patients, 37 had F1, 59 had F2, and 24 had F3 grade varices. Compared with the healthy controls, cirrhotic group had a significantly lower velocity in the PV, a significantly greater diameter of the PV and LGV, and a higher velocity in the LGV. In the cirrhotic group, no difference in portal flow velocity and diameter were observed between patients with or without esophageal variceal bleeding (EVB). However, the diameter and blood flow velocity of the LGV were significantly higher for EVB (+) group compared with EVB (-) group (P〈0.01). Diameter of the LGV increased with enlarged size of varices. There were differences between F1 and F2, F1 and F3 varices, but no differences between F2 and F3 varices (P = 0.125). However, variceal bleeding was more frequent in patients with a diameter of LGV 〉6 mm. The flow velocity in the LGV of healthy controls was 8.70+1.91 cm/s (n = 21). In patients with liver cirrhosis, it was 10.3+2.1 cm/s (n = 12) when the flow was hepatopetal and 13.5+2.3 cm/s (n = 87) when it was hepatofugal. As the size of varices enlarged, hepatofugal flow velocity increased (P〈0.01) and was significantly different between patients with F1 and F2 varices and between patients with F2 and F3 varices. Variceal bleeding was more frequent in patients with a hepatofugal flow velocity 〉15 cm/s (32 of 52 patients, 61.5%). Within the bleeding group, the mean LGV blood flow velocity was 16.6+2.62 cm/s. No correlation was observed between the portal blood flow velocity and EVB. In all healthy controls, the flow direction in the LGV was hepatopetal, toward the PV. In patients with F1 varices, flow direction was hepatopetal in 10 patients, to-and-fro state in 3 patients, and hepatofugal in the remaining 18. The flow was hepatofugal in 91% patients with F2 and all F3 varices. Changes in diameter of the PV and LGV were not significant before and after ingestion of glucose (PV: 1.41+1.5 cm before and 1.46+1.6 cm after; LGV: 0.57+1.7 cm before and 0.60+1.5 cm after). Flow direction in the LGV was hepatopetal and to-and-fro in 16 patients and hepatofugal in 44 patients before ingestion of glucose. Flow direction changed to hepatofugal in 9 of 16 patients with hepatopetal and to-and-fro blood flow after ingestion of glucose. In 44 patients with hepatofugal blood flow in the LGV, a significant increase in hepatofugal flow velocity was observed in 38 of 44 patients (86%) with esophageal varices. There was a relationship between the percentage changes in flow velocity and the size of varices. Patients who responded excessively to food ingestion might have a high risk for bleeding. The changes of blood flow velocity in the LGV were greater than those in the PV (LGV: 28.3+26.1%, PV: 7.2+13.2%, P〈0.01), whereas no significant changes in the LGV occurred before and after ingestion of glucose in the control subjects. CONCLUSION: Hemodynamics of the PV is unrelated to the degree of endoscopic abnormalities in patients with liver cirrhosis. The most important combinations are endoscopic findings followed by the LGV hemodynamics. Duplex-Doppler ultrasonography has no value in the identification of patients with cirrhosis at risk of variceal bleeding. Hemodynamics of the LGV appears to be superior to those of the PV in predicting bleeding. 展开更多
关键词 HEMODYNAMICS Esophageal varices Liver cirrhosis color doppler ultrasound
下载PDF
Clinical Evaluation of Color Doppler Ultrasound in Selecting the Optimal Treatment Modality for Infantile Hemangioma 被引量:6
3
作者 MinLi JuanLiu +2 位作者 ValeskaMaya DanLuo Bingrong Zhou 《Chinese Medical Sciences Journal》 CAS CSCD 2017年第2期100-106,共7页
Objective We investigated the efficacy and safety of 1064 nm Nd: YAG laser, intense pulsed light (IPL), and lauromacrogol injection in the treatment of hemangioma, in order to evaluate the value of color Doppler u... Objective We investigated the efficacy and safety of 1064 nm Nd: YAG laser, intense pulsed light (IPL), and lauromacrogol injection in the treatment of hemangioma, in order to evaluate the value of color Doppler ultrasound guidance in choosing the optimal treatment modality. Methods Infantile patients who were clinical diagnosed as hemangiomas were randomly divided into group A, who had color Doppler ultrasound examinations before the treatment, and group B who had the treatment without ultrasound evaluation. Patients in the group A were assigned into subgroups according to the depth of lesion by sonography: group A-1 for those who had a lesion depth 〈1.2 mm, and took intense pulsed light therapy; group A-2 for those who had a lesion depth ≥1.2mm and 〈 3 mm, and took long pulse 1064 nm Nd:YAG laser therapy; group A-3 for those who had a lesion depth ≥3mm and 〈5 mm, and were treated by IPL combined with long pulse 1064 nm Nd:YAG laser treatment; Group A-4 for those who had a lesion depth ≥5 mm, and took lauromacrogol injection therapy. Patients in the group B took long pulse 1064 nm Nd:YAG laser treatment without preoperative ultrasound evaluation. The efficacy and adverse reactions of the treatments between the groups were evaluated and compared statistically. Results Totally 113 patients with 128 skin lesions were enrolled in this study, 85 in the group A (mean age 6.8±7.9 months) and 28 in the group B (mean age 6.9±9.9 months). The mean depth of hemangioma was 3.3±1.1 mm in the group A, ranging from 0.5-7.8 mm, with 0.8±0.4 mm, 2.2±0.4 mm, 4.2±0.6 mm and 6.2±0.7 mm in group A1, A2, A3 and A4, respectively. The cure rates and effective rates in the group A were significantly higher than those in the group B (cure rates: 64.5% vs 56.3%, U=3.378, P=0.045; effective rates: 89.5% vs 78.1%, U=4.163, P=0.041). The adverse effect rates of the group A (vesicle 20.0%, pigmentation 46.9%, scarring 17.7%) were lower than those of the group B (vesicle 21.9%, pigmentation 60.4%, scarring 25.0%). Incidences of pigmentation and scarring were statistically significantly different (U=3.884, P=0.034, and U=4.016, P=0.032 respectively) between the two groups. Conclusion With the guidance of color Doppler ultrasound, the efficacy and safety of long pulse 1064 nmNd:YAG laser, intense pulsed light, and lauromacrogol injection in the treatment of infantile hemangioma have better outcomes compared to laser treatment alone without preoperative ultrasound examination. 展开更多
关键词 color doppler ultrasound infantile hemangioma Nd:YAG laser intense pulsed light LAUROMACROGOL
下载PDF
Assessment of Uterine Receptivity by Endometrial and Subendometrial Blood Flows Measured by Vaginal Color Doppler Ultrasound in Women Undergoing IVF Treatment 被引量:1
4
作者 Min-zhi GAO Xiao-ming ZHAO +3 位作者 Wen-ying LI Gui-mei LIU Xiao-feng JIA Hui-qin ZHANG 《Journal of Reproduction and Contraception》 CAS 2007年第3期205-212,共8页
Objective To evaluate endometrial and subendometrial blood flows measured by vaginal color Doppler ultrasound as a predicator of endometrial receptivity in women undergoing IVF treatment. Methods A total of 119 infert... Objective To evaluate endometrial and subendometrial blood flows measured by vaginal color Doppler ultrasound as a predicator of endometrial receptivity in women undergoing IVF treatment. Methods A total of 119 infertile patients undergoing the first IVF/ICSI-ET cycle were recruited. Three groups were divided according to a color Doppler ultrasound examination performed on the day of hCG injection. Group A, endometrial and subendometrial blood flows were 2 branches and below; group B, endometrial and subendometrial blood flows were between 3 and 4 branches; group C, endometrial and subendometrial blood flows were 5 branches and above. Patients were transferred 1-3 embryos each. Demographic data, ovarian responses, endometrial thickness, PI, RI, development of embryo and IVF result among groups were compared. Results Demographic data, ovarian responses, endometrial thickness, PI, RI and development of embryo among groups have no significant difference. The pregnancy rate of group A was significantly lower than that of group B (P〈0.05) and group C (P〈0.01). The implantation rate of group A was significantly lower than than of group C (P〈0.01). There was no significant difference of the rate of pregnancy and implantation between group B and group C (P〉0.05). Conclusion Endometrial and subendometrial blood flows measured by vaginal color Doppler ultrasound is a good predicator of pregnancy during IVF treatment. A good endometrial and subendometrial blood flows is benefit for the result of IVF. 展开更多
关键词 endometrial and subendometrial blood flows endometrial receptivity in vitro fertilization-embryo transfer (IVF) color doppler ultrasound
下载PDF
The Diagnostic Value of Color Doppler Ultrasound and Grey Scale Sonography in Predicting the Malignancy of Thyroid Nodules 被引量:2
5
作者 Hamad Elniel H. Eltyib Sameh A. Aborizk +2 位作者 Hanan A. Albalawi Afaf S. Almotairi Arwa H. Aidrus 《Open Journal of Radiology》 2020年第4期215-222,共8页
Retrospective study was done at KAUH to determine the sonographic characteristics in predicting the malignancy of thyroid nodules. The sample was 120 patients consisting of 70 benign nodules and 50 malignant nodules. ... Retrospective study was done at KAUH to determine the sonographic characteristics in predicting the malignancy of thyroid nodules. The sample was 120 patients consisting of 70 benign nodules and 50 malignant nodules. Out of 120 patients, 106 (88.3%) female and 14 (11.7%) male patients. Out of 106 female patients, 64 (91.45) had benign and 42 had malignant thyroid nodules. Out of 14 (11.7) male patients, 6 had benign and 8 had malignant thyroid nodules. The youngest patient in our study was 31 years and the oldest patient was 76 years. The common range of patients age was ≥ 60 years and consisting of twenty (28.6%) benign thyroid nodules and fourteen (28%) malignant thyroid nodules. The majority of patients’ age group with malignant thyroid nodules were between 50 - 60 years and consisting of twenty (40%) malignant nodules. In our study, according to the result of gray scale and color Doppler ultrasonography, hypo-echogenicity, solid echo structure, micro-calcification and intra-nodular vascularity were the significant characteristics of malignancy in nodules with sensitivity (72%, 74%, 48% and 88% respectively), specificity (66%, 63%, 94% and 69% respectively), PPV (60%, 59%, 86% and 67% respectively) and NPV (77%, 77%, 72% and 89% respectively). 展开更多
关键词 ultrasound Thyroid Nodules MALIGNANT color doppler Fine Needle Aspiration
下载PDF
Measurement of Liver Size and Intrahepatic Blood Flow of Red-eared Turtles by Color Doppler Ultrasound
6
作者 Cheng Yu Xie Fuqiang 《Animal Husbandry and Feed Science》 CAS 2015年第4期246-248,共3页
In the study, a total of 20 red-eared turtles ( half male and half female) were selected to conduct the measurement of liver size and intrahepatic blood flow of red-eared turtles by color Doppler ultrasound. The res... In the study, a total of 20 red-eared turtles ( half male and half female) were selected to conduct the measurement of liver size and intrahepatic blood flow of red-eared turtles by color Doppler ultrasound. The results showed that the fight hepatic lobe could be scanned through the right carotid anterior acoustic win- dow, and the left hepatic lobe could be scanned through the left carotid anterior acoustic window, but the vision would be obstructed by the air in trachea. The liver could also be scanned through the left femoral anterior acoustic window and the fight femoral anterior acoustic window when filling of bladder was good. The correla- tion regression analysis suggested that estimated values of liver showed no linear relationship with weight, the longest back curve and the widest back curve. Through the study, the normal indicators for ultrasound examination of red-eared turtle liver were established, in order to provide a reference for examination of turtle liver. 展开更多
关键词 Red-eared turtle color doppler ultrasound LIVER Blood flow
下载PDF
TREATMENT OF SIMPLE RENAL CYSTS BY COLOR DOPPLER ULTRASOUND GUIDED PERCUTANEOUS PUNCTURE CATHETERIZATION DRAINAGE AND 99% ETHANOL PERFUSION
7
作者 邓晓俊 褚建 +3 位作者 郎根强 曹建伟 庄剑秋 章益峰 《Medical Bulletin of Shanghai Jiaotong University》 CAS 2012年第2期69-73,共5页
Objective To investigate the effect and safety of the treatment of renal cysts with color Doppler ultrasound guided percutaneous puncture catheterization drainage and repeated 99% ethanol perfusion. MethodsFifty-eight... Objective To investigate the effect and safety of the treatment of renal cysts with color Doppler ultrasound guided percutaneous puncture catheterization drainage and repeated 99% ethanol perfusion. MethodsFifty-eight patients with primary renal cysts were treated with color Doppler ultrasound guided percutaneous puncture catheterization drainage and 99% ethanol perfusion. If the cyst volume was<500 mL, the complete evacuation of the cyst was followed by injection with 99% ethanol in a volume equal to 25% of the total cyst volume, twice per day, 10 min for each injection. If the cyst volume was>500 mL, injection was given three times per day, 20 min for each injection, and the patient was asked to move in different positions to help distributing the ethanol over the cyst wall. ResultsFifty-eight cysts were detected in the 58 patients. Puncture was performed and the success rate was 100%. Central venous catheter was introduced into the cysts. After follow-up for 0.5 to 3 years, 56 renal cysts were disappeared. The cure rate was 96.6%, and the complications such as bleeding, infection, and organ injuries were not found. ConclusionThe treatment of renal cyst with color Doppler ultrasound guided percutaneous puncture catheterization drainage and 99% ethanol injection is an effective and safe method for the patients with renal cysts. 展开更多
关键词 renal cyst puncture color doppler ultrasound central venous catheter ethanol
原文传递
Diagnosis of parathyroid tumor using Color Doppler ultrasound
8
作者 Qiuling Shi Haibo Fan Qi Lin Zhanghong Wei Ying Wu 《International English Education Research》 2014年第2期74-77,共4页
What the liver organized examining to the diagnosis of liver disease, course of disease alive is appraised and treated and taught fruits by stages, judge respects such as the prognosis, etc. play an important role. In... What the liver organized examining to the diagnosis of liver disease, course of disease alive is appraised and treated and taught fruits by stages, judge respects such as the prognosis, etc. play an important role. In recent years, supersound lead down, examine marksmanship walk liver puncture the technology that examines living to employ at clinic extensively becoming while being living. In order to appraise its application effect, specially carry on reviewing summary analysis. 展开更多
关键词 color doppler ultrasound DIAGNOSIS TUMOUR
下载PDF
Hemodynamic Changes on Color Doppler Flow Imaging and Intravenous Contrast-enhanced Ultrasound for Assessing Transplanted Liver and Early Diagnosis of Complications 被引量:1
9
作者 黄道中 陈云超 +1 位作者 李开艳 张青萍 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2008年第3期284-286,共3页
The value of color Doppler flow imaging (CDFI) and intravenous contrast-enhanced ultrasound (CEUS) for assessing the transplanted liver and early diagnosing complications by examining hemodynamic changes was discu... The value of color Doppler flow imaging (CDFI) and intravenous contrast-enhanced ultrasound (CEUS) for assessing the transplanted liver and early diagnosing complications by examining hemodynamic changes was discussed. Seventy-five patients with orthotopic liver transplantation (OLT) underwent CDFI. The following parameters were measured: peak systolic velocity (PS), resistance index (RI) and Doppler perfusion index (DPI) of the hepatic artery (HA), time average velocity (TAV) of portal vein (PV) and velocity of hepatic vein (HV) in different stages postoperation, And 11 patients of them received CEUS. Thirty healthy subjects were enrolled as controls, The results showed that: (1) In 23 patients without obvious complications, TAV of PV within 15 days post-operation was significantly higher than in controls (P〈0.05), PS and DPI of HA within 7 days postoperation were lower, but RI was higher than in controls (P〈0.05); (2) When the hepatic artery thrombosis (HAT) occurred, PS and DPI of HA were obviously decreased, but TAV of PV significantly increased like a high saw-tooth wave; (3) While rejection occurred, both TAV of PV and PS of HA were decreased with the increase in RI of HA, and the triphasic wave of HV disappeared and displayed as saw-tooth wave; (4) The incidence of biliary complications in liver transplantation was increased when DPI was reduced; (5) Seven cases of hepatic carcinoma relapse after OLT demonstrated hyperecho in the arterial phase and hypoecho in the portal and later phase on CEUS; (6) In 2 cases of HA thrombus, there was no visualized enhancement in arterial phase of CEUS, but enhancement during the portal vein and parenchymal phase. It was concluded that the hemodynamic changes of PV, HA and HV in the transplanted liver are valuable for assessing the transplanted liver and early diagnosing complications on CDFI and CEUS. 展开更多
关键词 color doppler flow imaging liver transplantation HEMODYNAMICS postoperative complications intravenous contrast-enhanced ultrasound
下载PDF
Color Doppler ultrasonographic examination on the relationship between the gallbladder bed and major branch of the middle hepatic vein 被引量:3
10
作者 Wei-Zhong Zhang, Jie Shen, Jue-Xing Xie and Hong Zhu Taizhou, China Departments of Surgery and Ultrasonography , Taizhou First People’s Hospital, Taizhou 318020, China 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS 2005年第2期299-301,共3页
BACKGROUND: There is a controversy about the risk of injury to the branch of the middle hepatic vein during lapa- roscopic cholecystectomy. This study was conducted to further investigate the relationship between the ... BACKGROUND: There is a controversy about the risk of injury to the branch of the middle hepatic vein during lapa- roscopic cholecystectomy. This study was conducted to further investigate the relationship between the gallbladder bed and the branch of the middle hepatic vein. METHODS: Color Doppler ultrasound was used to exa- mine the anatomical relationship between the gallbladder bed and the branches of the middle hepatic vein in 143 healthy volunteers. RESULTS: Not all the middle hepatic vein extended close to the gallbladder bed, the branches and gallbladder beds in 23 subjects were not in the same plane during ultrasound scanning. In 21 of the 143 subjects the branch of the middle hepatic vein was completely adherent to the gallbladder bed with a diameter ranging from 1.2 mm to 3.6 mm. In 10 subjects the branches of the middle hepatic vein traversed approximately 1.0 mm from the gallbladder bed with a dia- meter ranging from 1.6 mm to 3.0 mm. CONCLUSIONS: In most subjects the branch of the middle hepatic vein and the gallbladder bed are well separated. Only patients with large branches of the middle hepatic vein close to the gallbladder bed are at risk of hemorrhage during laparoscopic cholecystectomy. 展开更多
关键词 laparoscopic cholecystectomy color doppler ultrasound hepatic vein
下载PDF
Correlation Study of Color Doppler Examination of Deep Veins of Both Lower Extremities Combined with Fibrinolysis System in Hypertension during Pregnancy 被引量:4
11
作者 Chundong Qiu Haiyan Chen +3 位作者 Xiaohua Huang Xiaoling Kong Chong Liang Chunhong Qiu 《Open Journal of Obstetrics and Gynecology》 2020年第8期981-989,共9页
<strong>Objective</strong><span style="font-family:Verdana;"><strong>:</strong></span><span style="font-family:Verdana;"> To investigate the correlation be... <strong>Objective</strong><span style="font-family:Verdana;"><strong>:</strong></span><span style="font-family:Verdana;"> To investigate the correlation between deep static color Doppler ultrasound of both lower extremities combined with fibrinolytic system detection in pregnancy-induced hypertension.</span><span style="font-family:""> </span><b><span style="font-family:Verdana;">Methods</span></b><b><span style="font-family:Verdana;">:</span></b><span style="font-family:Verdana;"> A total of 70 normal pregnant women, 70 pregnant women with hypertension during pregnancy, and 50 healthy non-pregnant women in the same period were selected as the research objects. The deep veins of both lower limbs were examined by Rili Erlangshen’s color Doppler ultrasound diagnostic instrument (CDU),</span><span style="font-family:""> </span><span style="font-family:""><span style="font-family:Verdana;">and the </span><span style="font-family:Verdana;">fibrinolysis system was tested by enzyme-linked immunosorbent assay (ELISA) </span><span style="font-family:Verdana;">method and </span><a name="OLE_LINK12"></a><span style="font-family:Verdana;">automatic hemagglutination analyzer.</span><b><span style="font-family:Verdana;"> Results</span></b></span><b><span style="font-family:Verdana;">:</span></b><b><span style="font-family:""> </span></b><span style="font-family:Verdana;">Compared with the non-pregnant group, the inner diameters of the left/right femoral vein (CFV) and popliteal vein (POV) in the normal pregnancy group and the pregnancy-induced hypertension group were significantly widened, and the peak blood flow spectrum was significantly reduced. The difference was statistically significant (P < 0.01);FIB, PLG, t-PA, PAI, D-Dimer were significantly increased, the difference was statistically significant (P < 0.01);Compared with the normal pregnancy group, the inner diameter of the left/right femoral vein (CFV) in the hypertensive pregnancy group was significantly wider than that in the normal pregnancy group, and the peak value of the left/right POV blood flow spectrum was significantly lower than that in the normal pregnancy group,</span><span style="font-family:""> </span><span style="font-family:Verdana;">the difference w</span><span style="font-family:Verdana;">as</span><span style="font-family:Verdana;"> statistically significant (P < 0.01)</span><span style="font-family:Verdana;">,</span><span style="font-family:""> <span style="font-family:Verdana;">while the left/right popliteal vein (POV) inner diameter, left/right CFV blood flow peak value did not change significantly from the normal pregnancy</span><span style="font-family:Verdana;"> grou</span></span><span style="font-family:Verdana;">p, </span><span style="font-family:Verdana;">and the difference was not statistically significant (P > 0.05);FIB, PLG, PAI, D-Dimer of the hypertensive disease group during pregnancy significantly increased, the difference was statistically significant (P < 0.01), while t-PA was not statistically significant (P > 0.05).</span><span style="font-family:""> </span><b><span style="font-family:Verdana;">Conclusion</span></b><b><span style="font-family:Verdana;">:</span></b><b><span style="font-family:""> </span></b><span style="font-family:Verdana;">Normal pregnant women have a hypercoagulable state compared with healthy non-pregnant women, and pregnant women with hypertension during pregnancy are more likely to be in a pre-thrombotic state than pregnant women with normal pregnancy. Deep vein CDU examination of both lower extremities combined with blood fibrinolysis monitoring is of great value in the prevention and treatment of hypertension during pregnancy.</span> 展开更多
关键词 Hypertension during Pregnancy Prothrombotic State color doppler ultrasound Fibrinolysis Index
下载PDF
Paper Clinical Value of Color Doppler Ultrasonography in Diagnosis of Lower Extremity Arterial Disease of Diabetes Patients 被引量:2
12
作者 Jianyu Zhang Haijiao Mao 《Journal of Biosciences and Medicines》 2020年第6期209-214,共6页
<div style="text-align:justify;"> <strong>Objective:</strong> To evaluate the diagnostic value of color Doppler ultrasound in the diagnosis of diabetic lower extremity vascular diseases. &l... <div style="text-align:justify;"> <strong>Objective:</strong> To evaluate the diagnostic value of color Doppler ultrasound in the diagnosis of diabetic lower extremity vascular diseases. <strong>Methods: </strong>48 patients with diabetic lower extremity vascular disease admitted in our hos-pital from September 2018 to September 2019 were included in the study and divided into the observation group, and another 48 patients with the same period of health examination in our hospital were included in the study and divided into the control group. Both groups used color Doppler ultrasound to detect the blood flow of lower extremity vessels. The incidence of blood flow, vascular diameter and stenosis, occlusion and arteriosclerosis of the lower extremity were observed. <strong>Results:</strong> The blood flow and vascular di-ameter of the lower extremity in the observation group were significantly lower than those in the control group (p < 0.05). The incidence of vascular stenosis, vascular occlusion, thrombus, intimal thickening and plaque in the observation group was 85.42%, 22.92%, 10.42% and 93.75% respectively, which was significantly higher than that in the control group was 10.42%, 0.00%, 0.00% and 14.58% (p < 0.05). The incidence of lower extremity vascular lesions in the observation group was significantly higher than that in the control group (p < 0.05). <strong>Conclusion:</strong> Color Doppler ultrasound is of high diagnostic value in the diagnosis of diabetic lower extremity vascular diseases, and can be used to determine the blood flow of the lower extremity and the inner diameter of popliteal artery, thigh artery, dorsalis pedis artery and so on. At the same time, it can also clearly show the specific situation of vascular occlusion, arteriosclerosis and thrombosis, which is of great signif-icance for the prevention and diagnosis of lower extremity vascular lesions, and can provide the basis for the treatment of lower extremity vascular lesions. </div> 展开更多
关键词 Super color doppler ultrasound Diabetic Complications Lower Extremity Vascular Disease Diagnostic Value
下载PDF
Measurements Of Cerebral Blood Flow in Postasphyxiated Newborns by Color Doppler Imaging(CDI) 被引量:7
13
作者 常立文 汪元芳 刘婉君 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 1996年第4期249-252,共4页
Cerebral blood flow of 10 asphyxiated term newborns was continuously measured during the first 7 days of life and compared with that of 10 normal term infants by CDI. Frequency spectrum and blood flow variables in the... Cerebral blood flow of 10 asphyxiated term newborns was continuously measured during the first 7 days of life and compared with that of 10 normal term infants by CDI. Frequency spectrum and blood flow variables in the anterior, middle and posterior cerebral arteries were studied. The results showed evidently lower systolic amplitude in patients than that in normal subjects. End diastolic amplitude was zero in part of vessels, and values of bloed flow variables were all lower in day 1 of the life as compared with the control groups. Frequency spectrum recovered to normal patterns in 9 survived infants in day 2. but blood flow variables recovered to normal by day 7. Values of resistance index (RI) rose to 1 in some vessels of moderate hypoxic ischemic encephalopathy (HIE) infants and stayed at 1 in the severe HIE infants. It is concluded that low CBF plays a key role in brain damage of post-asphyxiated newborns and RI may be an important parameter in the evaluation prognosis. 展开更多
关键词 asphyxiated newborns cerebral blood flow ultrasound imaging color doppler
下载PDF
Role of color Doppler flow imaging in applicable anatomy of spleen vessels
14
作者 Wei-Li Xu Suo-Lin Li +2 位作者 Yan Wang Meng Li Ai-Guo Niu 《World Journal of Gastroenterology》 SCIE CAS CSCD 2009年第5期607-611,共5页
AIM: To explore the role of color Doppler flow imaging (CDFI) in visualization of spleen vessels and to define its value for spleen micro-invasive operation. METHODS: A total of 36 patients requiring laparoscopic ... AIM: To explore the role of color Doppler flow imaging (CDFI) in visualization of spleen vessels and to define its value for spleen micro-invasive operation. METHODS: A total of 36 patients requiring laparoscopic splenectomy (LS) for various hematopathies and autoimmune diseases were randomly selected from April 2005 to May 2008. Anatomic types of spleen pedicle, adjacent relations between spleen vessels and pancreas, diameters of spleen artery and vein were detected and recorded by preoperative CDFI. Different operative procedures were performed according to different anatomic frameworks. The parameters were recorded by telerecording during LS and compared with those by preoperative CDFI using Chi-square test. RESULTS: Two anatomic types of spleen pedicle and four different adjacent relations between spleen vessels and pancreas were detected by CDFI. The diameters of spleen artery and vein detected by CDFI were 0.46 ± 0.09 cm and 0.85 ± 0.35 cm, respectively. There was no statistical difference between the parameters recorded by CDFI and by telerecording (X^2 = 0.250, 0.677, P 〉 0.05). LS was successfully performed following the anatomic information provided by preoperative CDFI.CONCLUSION: Different anatomic frameworks of spleen vessels can be provided by preoperative CDFI, which instructs micro-invasive operation of spleen and increase the safety of operation. 展开更多
关键词 ultrasound color doppler imaging SPLEEN ANATOMY Laparoscopic operation
下载PDF
钼靶和超声多普勒结合血清肿瘤标志物诊断早期乳腺癌研究 被引量:3
15
作者 王海霞 宋倩 +1 位作者 郑国红 曹钢 《中国医学装备》 2024年第1期82-87,共6页
目的:探讨钼靶、超声多普勒和血清肿瘤标志物中血清前列腺特异抗原(PSA)、血清糖类抗原15-3(CA153)、黏蛋白1(MUC1)、人类生长分化因子3(GDF3)单独及联合检测在早期乳腺癌诊断中的价值。方法:选取2018年1月至2021年12月在唐山市人民医... 目的:探讨钼靶、超声多普勒和血清肿瘤标志物中血清前列腺特异抗原(PSA)、血清糖类抗原15-3(CA153)、黏蛋白1(MUC1)、人类生长分化因子3(GDF3)单独及联合检测在早期乳腺癌诊断中的价值。方法:选取2018年1月至2021年12月在唐山市人民医院经病理检查确诊的96例乳腺癌患者(乳腺癌组)和同期在本院接受诊治的70例乳腺良性疾病患者(良性病灶组)以及同时选取在本院体检健康的50名体检者(健康对照组),以术后病理检查为“金标准”,比较钼靶、超声多普勒检查以及血清PSA、CA153、MUC1、GDF3单独及6者联合应用对乳腺癌的诊断价值。结果:乳腺癌组96例乳腺癌患者中有78例乳腺超声诊断为恶性,阳性检出率为81.3%;80例钼靶X射线检查诊断为恶性,阳性检出率为83.1%;乳腺癌组的血清PSA、CA153、MUC1及GDF3的水平明显高于良性病灶组和健康对照组,差异均有统计学意义(t_(良性病灶组)=8.783、10.361、11.258、18.965;t_(健康对照组)=9.564、12.658、12.688、20.163,P<0.05);以乳腺癌作为因变量,血清PSA、CA153、MUC1及GDF3为自变量,进行Logistic回归分析,血清PSA、CA153、MUC1及GDF3是乳腺癌的重要危险因素(OR=1.165、1.168、1.472、1.248,P<0.05);受试者工作特征(ROC)曲线分析各指标单独应用时:乳腺超声、钼靶,血清PSA、CA153、MUC1及GDF3的ROC曲线下面积(AUC)(95%CI)、灵敏度和特异度分别为0.723(0.595~0.851)、82.56%和67.32%,0.761(0.636~0.886)、85.79%和65.36%,0.833(0.726~0.941)、81.48%和85.73%,0.837(0.738~0.926)、61.25%和70.17%,0.768(0.648~0.889)、71.49%和80.87%,0.613(0.469~0.758)、52.94%和50.57%;而6项联合应用时AUC(95%CI)、灵敏度和特异度分别为0.958(0.905~0.999)、96.37%和84.83%,其诊断效能更高。结论:钼靶、超声多普勒和血清PSA、CA153、MUC1、GDF3联合检测效能高于单独检测,有助于早期鉴别和诊断乳腺癌。 展开更多
关键词 乳腺癌 钼靶X射线摄影 彩色多普勒超声 前列腺特异性抗原(PSA) 糖类抗原153(CA153) 黏蛋白1(MUC1) 人生长分化因子3(GDF3)
下载PDF
彩色多普勒超声血流评分对附件扭转患者卵巢活性的预测价值 被引量:1
16
作者 田彩 杜洁贤 +1 位作者 赵聪颖 温树彬 《河北医药》 CAS 2024年第3期400-403,共4页
目的研究卵巢彩色多普勒血流成像(CDFI)评分预测附件扭转患者卵巢活性的价值。方法选取经手术证实的32例附件扭转患者,根据卵巢血流信号进行评分,将其与术中卵巢活性进行对比分析。结果卵巢CDFI评分推测卵巢存活的灵敏度为90%,特异度为8... 目的研究卵巢彩色多普勒血流成像(CDFI)评分预测附件扭转患者卵巢活性的价值。方法选取经手术证实的32例附件扭转患者,根据卵巢血流信号进行评分,将其与术中卵巢活性进行对比分析。结果卵巢CDFI评分推测卵巢存活的灵敏度为90%,特异度为81.82%,阳性预测值为69.23%,阴性预测值为94.74%,卵巢CDFI血流存在与手术中卵巢存活的一致性较好,Kappa值为0.664。结论CDFI能够对附件扭转者卵巢活性进行预估,卵巢血流评分可为临床提供较为可靠、有效的影像学依据。 展开更多
关键词 超声 彩色多普勒血流成像 附件扭转 卵巢肿瘤
下载PDF
超声造影诊断下肢淋巴水肿的研究进展
17
作者 付文艳 王雅晳 +3 位作者 段莎莎 施依璐 金之湲 张小杉 《中国医学影像学杂志》 CSCD 北大核心 2024年第1期109-112,共4页
下肢淋巴水肿是一种慢性、进行性疾病,严重影响患者生活质量;早期诊断和治疗可延缓病情进展,有利于改善患者预后。目前常见的下肢淋巴水肿诊断技术均具有一定的缺点而使应用受限。超声造影具有无创、便捷、实时、重复性好的特点,能够增... 下肢淋巴水肿是一种慢性、进行性疾病,严重影响患者生活质量;早期诊断和治疗可延缓病情进展,有利于改善患者预后。目前常见的下肢淋巴水肿诊断技术均具有一定的缺点而使应用受限。超声造影具有无创、便捷、实时、重复性好的特点,能够增强淋巴管中淋巴液的显像,对浅表淋巴管显像具有较高敏感度,近年来逐渐应用于下肢淋巴水肿诊断。本文对超声造影在下肢淋巴水肿中的应用情况进行综述。 展开更多
关键词 下肢淋巴水肿 超声造影 彩色多普勒超声 综述
下载PDF
急性粒-单核细胞白血病患者造血干细胞移植后微血栓形成凝血指标监测及治疗1例报告
18
作者 沈连军 吴蔚 +6 位作者 吉薇 王红 孙幸 施青青 孙梅 顾健 倪军 《诊断学理论与实践》 2024年第2期180-183,共4页
本文报道1例急性粒-单核细胞白血病(急性髓系白血病M4型)(CBFB基因阳性)患者,经亲缘半相合造血干细胞移植后并发下肢微血栓形成,并总结其诊治经验。该患者经常规化疗后获完全缓解,但又于2年后复发,遂予行亲缘半相合造血干细胞移植。在... 本文报道1例急性粒-单核细胞白血病(急性髓系白血病M4型)(CBFB基因阳性)患者,经亲缘半相合造血干细胞移植后并发下肢微血栓形成,并总结其诊治经验。该患者经常规化疗后获完全缓解,但又于2年后复发,遂予行亲缘半相合造血干细胞移植。在患者接受移植后的常规治疗期间,动态观察其凝血相关指标[包括D-二聚体(D-dimer, D-D)、抗凝血酶Ⅲ(antithrombinⅢ,AT-Ⅲ)、血管性血友病因子(von Willebrand factor, vWF)、纤维蛋白原降解产物(fibrinogen degradation products, FDP)、纤维蛋白单体(fibrin monomer, FM)]。在移植后100 d左右,患者出现黄疸及转氨酶升高,采用经右下肢股静脉置管行血浆置换治疗3次。在去除静脉置管1周后,患者出现左踝部指凹性水肿,血管B超检查提示其左下肢腓肠肌浅静脉丛有微血栓形成;凝血指标检测显示,D-D、vWF、FDP、FM等指标升高,AT-Ⅲ水平降低。予口服拜瑞妥5 mg/d抗栓治疗2周后,患者上述凝血指标渐趋正常,左下肢肌间静脉丛血栓和肢肿消失。在造血干细胞移植后,除密切检查血管B超,动态监测D-D、AT-Ⅲ、vWF、FDP、FM等凝血指标可预测移植相关微血栓和高凝状态,并为临床开展有效抗的凝治疗提供实验依据。 展开更多
关键词 凝血指标 亲缘半相合造血干细胞移植 微血栓形成 彩色多普勒超声
下载PDF
彩色多普勒超声对感染性休克病人肾脏血流动力学及预后评估的价值
19
作者 徐维 许继元 +2 位作者 李茂琴 曹健锋 朱莎莎 《安徽医药》 CAS 2024年第3期581-585,共5页
目的 分析彩色多普勒超声检测感染性休克病人肾脏血流动力学参数及其对预后评估的价值。方法 回顾性分析徐州市中心医院2019年1月至2020年1月收治120例感染性休克病人病历资料,按病人急性肾损伤(AKI)程度分为无AKI组(n=23)、AKI 1~2期组... 目的 分析彩色多普勒超声检测感染性休克病人肾脏血流动力学参数及其对预后评估的价值。方法 回顾性分析徐州市中心医院2019年1月至2020年1月收治120例感染性休克病人病历资料,按病人急性肾损伤(AKI)程度分为无AKI组(n=23)、AKI 1~2期组(n=46)和AKI 3期组(n=51),对比三组肾血流动力学参数检查结果,分析病人肾血流动力学参数与肾功能损害的关系;依据病人预后情况分为存活组(n=52)和死亡组(n=68),分析彩色多普勒超声检测肾脏血流动力学参数与病人预后的关系。结果 与无AKI组病人相比,AKI 1~2期组和AKI 3期组病人的肾叶间动脉收缩期最大血流速度(PSV)[(34.57±5.01)cm/s、(29.32±4.53)cm/s比(54.21±7.00)cm/s]和舒张末期血流速度(EDV)[(12.18±3.01)cm/s、(9.54±2.49)cm/s比(24.87±3.59)cm/s]显著下降(P<0.05);PSV和EDV随AKI分期增加而显著下降(P<0.05),肾血管阻力指数(RI)随AKI分期增加而升高(P<0.05);PSV和EDV与感染性休克病人的AKI分期呈负相关,RI与AKI分期呈正相关。死亡组病人的EDV(11.06±3.00)cm/s显著低于存活组(16.65±5.21)cm/s(P<0.05),RI显著高于存活组(P<0.05);死亡组病人的基础疾病占比63.24%、急性生理学和慢性健康状况评价Ⅱ(APACHEⅡ)(24.87±4.77)分和多器官功能障碍综合征(MODS)评分(7.12±0.89)分均显著高于存活组[40.38%、(17.21±4.12)分、(5.37±0.54)分](P<0.05);基础疾病、APACHEⅡ评分、MODS评分、EDV以及RI均是感染性休克病人预后评估的独立危险因素(P<0.05),方差膨胀因子(VIF)均<3。结论 彩色多普勒超声检测感染性休克病人的肾脏血流动力学可反映AKI病情严重程度,可用于评估病人的预后。 展开更多
关键词 感染性休克 彩色多普勒超声 肾脏血流动力学 肾功能损害 预后
下载PDF
DNA无创产前检测及彩色多普勒超声检查在高危孕妇胎儿 染色体异常筛查中的应用价值
20
作者 成艳 马雯 +2 位作者 权秋宁 于青 杜小云 《检验医学与临床》 CAS 2024年第2期217-220,共4页
目的探讨DNA无创产前检测(NIPT)及彩色多普勒超声(简称彩超)检查在高危孕妇胎儿染色体异常筛查中的应用价值。方法选取2020年1月至2022年12月于该院接受产前检查的5862例高危孕妇作为研究对象,均接受NIPT、彩超检查,以羊水穿刺结果或分... 目的探讨DNA无创产前检测(NIPT)及彩色多普勒超声(简称彩超)检查在高危孕妇胎儿染色体异常筛查中的应用价值。方法选取2020年1月至2022年12月于该院接受产前检查的5862例高危孕妇作为研究对象,均接受NIPT、彩超检查,以羊水穿刺结果或分娩结局作为诊断胎儿染色体异常的金标准,比较NIPT、彩超检查及二者联合检查对高危孕妇胎儿染色体异常的诊断效能。结果5862例高危孕妇中共检出167例胎儿染色体异常,检出率为2.85%。167例胎儿染色体异常中胎儿染色体数目异常161例,构成比为96.41%;胎儿染色体结构异常6例,构成比为3.59%。彩超检查共诊断出119例孕妇胎儿染色体异常,经一致性分析,彩超检查诊断胎儿染色体异常的灵敏度为0.713,特异度为0.884,准确率为87.96%,Kappa=0.215,P<0.05。NIPT共诊断出133例孕妇胎儿染色体异常,经一致性分析,NIPT诊断胎儿染色体异常的灵敏度为0.796,特异度为0.945,准确率为94.05%,Kappa=0.408,P<0.05。彩超检查联合NIPT共诊断出158例孕妇胎儿染色体异常,经一致性分析,二者联合检查诊断胎儿染色体异常的灵敏度为0.946,特异度为0.986,准确率为98.50%,Kappa=0.775,P<0.05。结论NIPT与彩超检查用于筛查高危孕妇胎儿染色体异常均具有一定价值,二者联合检查可获得更高的灵敏度、特异度和准确率,能有效降低漏诊及误诊风险。 展开更多
关键词 DNA无创产前检测 彩色多普勒超声检查 高危孕妇 胎儿染色体异常 应用价值
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部