A comparative study of pancreatic endocrine function and related metabolism after long-term survival between the patients with combined kidneypancreas transplantation vs those with combined en bloc ' liver-pancreas transplantation
1
作者 朱晓峰 《外科研究与新技术》 2011年第4期292-292,共1页
Objective To compare the effects of combined en bloc liver - pancreas transplantation ( LPT) with portal vein drainage and simultaneous combined kidney - pancreas transplantation ( KPT) with systemic venous drainage o... Objective To compare the effects of combined en bloc liver - pancreas transplantation ( LPT) with portal vein drainage and simultaneous combined kidney - pancreas transplantation ( KPT) with systemic venous drainage on the pancreatic endocrine function and related me- 展开更多
关键词 LPT A comparative study of pancreatic endocrine function and related metabolism after long-term survival between the patients with combined kidneypancreas transplantation vs those with combined en bloc liver-pancreas transplantation KPT
下载PDF
Land deformation monitoring in mining area with PPP-AR 被引量:5
2
作者 Hu Hong Gao Jingxiang Yao Yifei 《International Journal of Mining Science and Technology》 SCIE EI 2014年第2期207-212,共6页
The mining area deformation monitoring theory and method using precise point positioning (PPP) ambi- guity resolution (AR) were studied, and an ambiguity fixing model with satellite and receiver combina- tion phas... The mining area deformation monitoring theory and method using precise point positioning (PPP) ambi- guity resolution (AR) were studied, and an ambiguity fixing model with satellite and receiver combina- tion phase delay (CPD) was proposed for zero-differenced PPP ambiguity fixing and its corresponding formula derivation was given. The data processing results for I h at six IGS stations in China show that 93% of ambiguities can be fixed within 10 min and all ambiguities can be fixed within 15 min. After ambi- guity fixing, the positioning accuracy is improved by more than 85% in the E and N directions, with abso- lute positioning accuracy reaching millimeter level, and it was improved by 70% in the U direction, reaching centimeter level; the proposed zero-differenced ambiguity fixing model can effectively improve the convergence rate and positioning accuracy in PPP. Data monitoring continuously conducted for half a year at four COPS stations of Shanxi China Coal Pingshuo Group validated the feasibility of using PPP in mining area deformation monitoring. 展开更多
关键词 Deformation monitoring precise point positioning Ambiguity combination phase delay (CPD) Ionosphere-free combination
下载PDF
On the System Performance of Mobile Edge Computing in an Uplink NOMA WSN With a Multiantenna Access Point Over Nakagami-m Fading 被引量:1
3
作者 Van-Truong Truong Van Nhan Vo +1 位作者 Dac-Binh Ha Chakchai So-In 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2022年第4期668-685,共18页
In this paper,we study the system performance of mobile edge computing(MEC)wireless sensor networks(WSNs)using a multiantenna access point(AP)and two sensor clusters based on uplink nonorthogonal multiple access(NOMA)... In this paper,we study the system performance of mobile edge computing(MEC)wireless sensor networks(WSNs)using a multiantenna access point(AP)and two sensor clusters based on uplink nonorthogonal multiple access(NOMA).Due to limited computation and energy resources,the cluster heads(CHs)offload their tasks to a multiantenna AP over Nakagami-m fading.We proposed a combination protocol for NOMA-MEC-WSNs in which the AP selects either selection combining(SC)or maximal ratio combining(MRC)and each cluster selects a CH to participate in the communication process by employing the sensor node(SN)selection.We derive the closed-form exact expressions of the successful computation probability(SCP)to evaluate the system performance with the latency and energy consumption constraints of the considered WSN.Numerical results are provided to gain insight into the system performance in terms of the SCP based on system parameters such as the number of AP antennas,number of SNs in each cluster,task length,working frequency,offloading ratio,and transmit power allocation.Furthermore,to determine the optimal resource parameters,i.e.,the offloading ratio,power allocation of the two CHs,and MEC AP resources,we proposed two algorithms to achieve the best system performance.Our approach reveals that the optimal parameters with different schemes significantly improve SCP compared to other similar studies.We use Monte Carlo simulations to confirm the validity of our analysis. 展开更多
关键词 Mobile edge computing(MEC) Nakagami-m fading OFFLOADING selection combining(SC)/maximal ratio combining(MRC) successful computation probability(SCP) uplink nonortho-gonal multiple access(NOMA) wireless sensor networks(WSNs)
下载PDF
SURVEY ON CLINICAL STUDY OF COMPOUND ACUPUNCTURE ANESTHESIA IN RECENT 10 YEARS IN CHINA
4
作者 秦必光 胡北喜 张兰英 《World Journal of Acupuncture-Moxibustion》 2002年第3期3-7,共5页
In the present paper, the authors make a review on the progresses of acupuncture anesthesia (AA) from ① historical development, ② research on acupuncture combined with local anesthesia; ③ research on acupuncture co... In the present paper, the authors make a review on the progresses of acupuncture anesthesia (AA) from ① historical development, ② research on acupuncture combined with local anesthesia; ③ research on acupuncture combined with epidural anesthesia; and ④ research on acupuncture combined with general anesthesia. Compound acupuncture anesthesia provides a new anesthetic measure for surgical operations and has a definite analgesic effect and many advantages, and should be investigated further. 展开更多
关键词 Acupuncture anesthesia Acupuncture combined with local anesthesia Acupuncture combined with epidural anesthesia Acupuncture combined with general anesthesia