BACKGROUND The management of hepatoblastoma(HB)becomes challenging when the tumor remains in close proximity to the major liver vasculature(PMV)even after a full course of neoadjuvant chemotherapy(NAC).In such cases,e...BACKGROUND The management of hepatoblastoma(HB)becomes challenging when the tumor remains in close proximity to the major liver vasculature(PMV)even after a full course of neoadjuvant chemotherapy(NAC).In such cases,extreme liver resection can be considered a potential option.AIM To explore whether computer-assisted three-dimensional individualized extreme liver resection is safe and feasible for children with HB who still have PMV after a full course of NAC.METHODS We retrospectively collected data from children with HB who underwent surgical resection at our center from June 2013 to June 2023.We then analyzed the detailed clinical and three-dimensional characteristics of children with HB who still had PMV after a full course of NAC.RESULTS Sixty-seven children diagnosed with HB underwent surgical resection.The age at diagnosis was 21.4±18.8 months,and 40 boys and 27 girls were included.Fifty-nine(88.1%)patients had a single tumor,39(58.2%)of which was located in the right lobe of the liver.A total of 47 patients(70.1%)had PRE-TEXT III or IV.Thirty-nine patients(58.2%)underwent delayed resection.After a full course of NAC,16 patients still had close PMV(within 1 cm in two patients,touching in 11 patients,compressing in four patients,and showing tumor thrombus in three patients).There were 6 patients of tumors in the middle lobe of the liver,and four of those patients exhibited liver anatomy variations.These 16 children underwent extreme liver resection after comprehensive preoperative evaluation.Intraoperative procedures were performed according to the preoperative plan,and the operations were successfully performed.Currently,the 3-year event-free survival of 67 children with HB is 88%.Among the 16 children who underwent extreme liver resection,three experienced recurrence,and one died due to multiple metastases.CONCLUSION Extreme liver resection for HB that is still in close PMV after a full course of NAC is both safe and feasible.This approach not only reduces the necessity for liver transplantation but also results in a favorable prognosis.Individualized three-dimensional surgical planning is beneficial for accurate and complete resection of HB,particularly for assessing vascular involvement,remnant liver volume and anatomical variations.展开更多
BACKGROUND Subchorionic hematoma(SCH)is a common complication in early pregnancy characterized by the accumulation of blood between the uterine wall and the chorionic membrane.SCH can lead to adverse pregnancy outcome...BACKGROUND Subchorionic hematoma(SCH)is a common complication in early pregnancy characterized by the accumulation of blood between the uterine wall and the chorionic membrane.SCH can lead to adverse pregnancy outcomes such as miscarriage,preterm birth,and other complications.Early detection and accurate assessment of SCH are crucial for appropriate management and improved pregnancy outcomes.AIM To evaluate the diagnostic efficacy of virtual organ computer-assisted analysis(VOCAL)in measuring the volume ratio of SCH to gestational sac(GS)combined with serum progesterone on early pregnancy outcomes in patients with SCH.METHODS A total of 153 patients with SCH in their first-trimester pregnancies between 6 and 11 wk were enrolled.All patients were followed up until a gestational age of 20 wk.The parameters of transvaginal two-dimensional ultrasound,including the circumference of SCH(Cs),surface area of SCH(Ss),circumference of GS(Cg),and surface area of GS(Sg),and the parameters of VOCAL with transvaginal three-dimensional ultrasound,including the three-dimensional volume of SCH(3DVs)and GS(3DVg),were recorded.The size of the SCH and its ratio to the GS size(Cs/Cg,Ss/Sg,3DVs/3DVg)were recorded and compared.RESULTS Compared with those in the normal pregnancy group,the adverse pregnancy group had higher Cs/Cg,Ss/Sg,and 3DVs/3DVg ratios(P<0.05).When 3DVs/3DVg was 0.220,the highest predictive performance predicted adverse pregnancy outcomes,resulting in an AUC of 0.767,and the sensitivity,specificity were 70.2%,75%respectively.VOCAL measuring 3DVs/3DVg combined with serum progesterone gave a diagnostic AUC of 0.824 for early pregnancy outcome in SCH patients,with a high sensitivity of 82.1%and a specificity of 72.1%,which showed a significant difference between AUC.CONCLUSION VOCAL-measured 3DVs/3DVg effectively quantifies the severity of SCH,while combined serum progesterone better predicts adverse pregnancy outcomes.展开更多
This paper discusses the approach to the CET (college English test) oral test based on automatic essay marking (AEM). The reliability and validity arouses a dispute on Internet-based CET (iB-CET) oral test in Ch...This paper discusses the approach to the CET (college English test) oral test based on automatic essay marking (AEM). The reliability and validity arouses a dispute on Internet-based CET (iB-CET) oral test in China, leading to the penetration into oral test contents in dialogue, description or comment, and question answering. Then, a probe into transformation from a spoken document into a textual document is touched on a conversion ratio of 72% adopted at the present time, AEM to be carried forward being a necessary hypothesis for Afterwards, this paper focuses on the pipeline in AEM with the content features and the language itself, which is established in two different models in marking for extraction and detection. Through experiments, this paper reveals the fact that an iB-CET oral test can be performed perfectly in the pipeline of spoken documents transformed into textual documents which can be automatically marked. Hence the design of the iB-CET oral test reaches its reliability and validity.展开更多
The computer-assisted surgery (CAS)has significantly improved the accuracy, reliability and outcomes of traumatic,spinal,nerve surgery and many other operations with a less invasive way.The application of CAS for scap...The computer-assisted surgery (CAS)has significantly improved the accuracy, reliability and outcomes of traumatic,spinal,nerve surgery and many other operations with a less invasive way.The application of CAS for scaphoid fractures remains experimental.The related studies are scanty and most of them are cadaver researches.Some intrinsic defects from the registration procedure,scan and immobilization of limbs may inevitably result in deviations. Some deviations become more obvious with operations of small bones (such as scaphoid)although they are acceptable for spine and other orthopedic surgeries.We reviewed the current literatures on the applications of CAS for scaphoid operation and summarized technical principles,scan and registration methods,immobilization of limbs and their outcomes.On the basis of the data,we analyzed the limitations of this technique and envisioned its future development.展开更多
BACKGROUND Artificial intelligence in colonoscopy is an emerging field,and its application may help colonoscopists improve inspection quality and reduce the rate of missed polyps and adenomas.Several deep learning-bas...BACKGROUND Artificial intelligence in colonoscopy is an emerging field,and its application may help colonoscopists improve inspection quality and reduce the rate of missed polyps and adenomas.Several deep learning-based computer-assisted detection(CADe)techniques were established from small single-center datasets,and unrepresentative learning materials might confine their application and generalization in wide practice.Although CADes have been reported to identify polyps in colonoscopic images and videos in real time,their diagnostic performance deserves to be further validated in clinical practice.AIM To train and test a CADe based on multicenter high-quality images of polyps and preliminarily validate it in clinical colonoscopies.METHODS With high-quality screening and labeling from 55 qualified colonoscopists,a dataset consisting of over 71000 images from 20 centers was used to train and test a deep learning-based CADe.In addition,the real-time diagnostic performance of CADe was tested frame by frame in 47 unaltered full-ranged videos that contained 86 histologically confirmed polyps.Finally,we conducted a selfcontrolled observational study to validate the diagnostic performance of CADe in real-world colonoscopy with the main outcome measure of polyps per colonoscopy in Changhai Hospital.RESULTS The CADe was able to identify polyps in the test dataset with 95.0%sensitivity and 99.1%specificity.For colonoscopy videos,all 86 polyps were detected with 92.2%sensitivity and 93.6%specificity in frame-by-frame analysis.In the prospective validation,the sensitivity of CAD in identifying polyps was 98.4%(185/188).Folds,reflections of light and fecal fluid were the main causes of false positives in both the test dataset and clinical colonoscopies.Colonoscopists can detect more polyps(0.90 vs 0.82,P<0.001)and adenomas(0.32 vs 0.30,P=0.045)with the aid of CADe,particularly polyps<5 mm and flat polyps(0.65 vs 0.57,P<0.001;0.74 vs 0.67,P=0.001,respectively).However,high efficacy is not realized in colonoscopies with inadequate bowel preparation and withdrawal time(P=0.32;P=0.16,respectively).CONCLUSION CADe is feasible in the clinical setting and might help endoscopists detect more polyps and adenomas,and further confirmation is warranted.展开更多
The aim of the present study was to compare assessments of sperm concentration and sperm motility analysed by conventional semen analysis with those obtained by computer-assisted semen analysis (CASA) (Copenhagen R...The aim of the present study was to compare assessments of sperm concentration and sperm motility analysed by conventional semen analysis with those obtained by computer-assisted semen analysis (CASA) (Copenhagen Rigshospitalet Image House Sperm Motility Analysis System (CRISMAS) 4.6 software) using semen samples from 166 young Danish men. The CRISMAS software identifies sperm concentration and classifies spermatozoa into three motility categories. To enable comparison of the two methods, the four motility stages obtained by conventional semen analysis were, based on their velocity classifications, divided into three stages, comparable to the three CRISMAS motility categories: rapidly progressive (A), slowly progressive (B) and non-progressive (C+ D). Differences between the two methods were large for all investigated parameters (P〈0.001). CRISMAS overestimated sperm concentration and the proportion of rapidly progressive spermatozoa and, consequently, underestimated the percentages of slowly progressive and non-progressive spermatozoa, compared to the conventional method. To investigate whether results drifted according to time of semen analysis, results were pooled into quarters according to date of semen analysis. CRISMAS motility results appeared more stable over time compared to the conventional analysis; however, neither method showed any trends. Apparently, CRISMAS CASA results and results from the conventional method were not comparable with respect to sperm concentration and motility analysis. This needs to be accounted for in clinics using this software and in studies of determinants of these semen characteristics.展开更多
Glutathione peroxidase, the first example of selenoproteins identified in mammals, was subjected to force field calculations and molecular dynamics in order to enable a clearer comprehension of enzymatic selenium cata...Glutathione peroxidase, the first example of selenoproteins identified in mammals, was subjected to force field calculations and molecular dynamics in order to enable a clearer comprehension of enzymatic selenium catalysis. Starting from the established X-ray structure of bovine GPX, all kinetically defined intermediates and enzyme substrate complexes were modelled. The models thus obtained support the hypothesis that the essential steps of the catalysis are three distinct redox changes of the active site selenium which, in the ground state, presents itself at the surface of selenoperoxidases as the center of a characteristic triad built by selenocysteine, glutarnine and tryptophan. In GPX, four arginine residues and a lysine residue provide an electrostatic architecture which, in each reductive step, directs the donor substrate GSH towards the catalytic center in such a way that 1ts sulfhydryl group must react with the selenium moiety. To this end, different equally efficient modes of substrate binding appear possible. The models are consistent with substrate specificity data, kinetic pattern and other functional characteristics of the enzyme. Comparison of molecular models of GPX with those of other members of the GPX superfamily reveals that the cosubstrate binding mechanisrns are unique for the classical type of cytosolic glutathione peroxidases but cannot operate e. g. in plasma GPX and phospholipid hydroperoxide GPX. The structural differences between the selenoperoxidases, shown to be relevant to their specificities, are discussed in terms of functional diversification within the GPX superfamily展开更多
Animals have evolved a variety of behavior patterns to adapt to the environment. Motion-capture technology is utilized to quantify and characterize locomotor behaviors to reveal the mechanisms of animal motion. In the...Animals have evolved a variety of behavior patterns to adapt to the environment. Motion-capture technology is utilized to quantify and characterize locomotor behaviors to reveal the mechanisms of animal motion. In the capture of flexible, small animals with complex locomotor behaviors, the markers interfere with each other easily, and the motion forms(bending, twisting) of the moving parts are obviously different;thus, it is a great challenge to realize accurate quantitative characterization of complex locomotor behaviors. The correlation between the marker properties, including the size and space length, and the precision of the system are revealed in this paper, and the effects of diverse marker shapes on the capturing accuracy of the captured objects in different motion forms were tested. Results showed that the precision of system is significantly improved when the ratio of the space length to the diameter of the markers is larger than four;for the capture of the spatial twisting motion of the flexible object, the hexagon markers had the lowest spatial lost-marker rate relative to the circle, triangle, and square. Customized markers were used to capture the locomotor behavior of the gecko-inspired robot(rigid connection) and the gecko(flexible connection). The results showed that this marking technology can achieve high accuracy of motion capture for geckos(the average deviation was approximately 0.32 mm, and the average deviation’s variation rate was approximately 0.96%). In this paper, the marking technology for the motion capture of flexible, small animals with complex motion is proposed;it can effectively improve the system precision as well as the capture accuracy, and realize the quantitative characterization of the complex motion of flexible, small objects. It provides a reliable technical means to deeply study the evolution of the motion function of small animals and advance systematic research of motion-capture technology.展开更多
Autonomic networking is one of the hot research topics in the research area of future network architectures.In this paper, we introduce context-aware and autonomic attributes into DiffServ QoS framework, and propose a...Autonomic networking is one of the hot research topics in the research area of future network architectures.In this paper, we introduce context-aware and autonomic attributes into DiffServ QoS framework, and propose a novel autonomic packet marking(APM) algorithm.In the proposed autonomic QoS framework, APM is capable of collecting various QoS related contexts, and adaptively adjusting its behavior to provide better QoS guarantee according to users' requirements and network conditions.Simulation results show that APM provides better performance than traditional packet marker, and significantly improves user's quality of experience.展开更多
The essential requirement for precise localization of a self-driving car is a lane-level map which includes road markings(RMs).Obviously,we can build the lane-level map by running a mobile mapping system(MMS)which is ...The essential requirement for precise localization of a self-driving car is a lane-level map which includes road markings(RMs).Obviously,we can build the lane-level map by running a mobile mapping system(MMS)which is equipped with a high-end 3D LiDAR and a number of high-cost sensors.This approach,however,is highly expensive and ineffective since a single high-end MMS must visit every place for mapping.In this paper,a lane-level RM mapping system using a monocular camera is developed.The developed system can be considered as an alternative to expensive high-end MMS.The developed RM map includes the information of road lanes(RLs)and symbolic road markings(SRMs).First,to build a lane-level RM map,the RMs are segmented at pixel level through the deep learning network.The network is named RMNet.The segmented RMs are then gathered to build a lane-level RM map.Second,the lane-level map is improved through loop-closure detection and graph optimization.To train the RMNet and build a lane-level RM map,a new dataset named SeRM set is developed.The set is a large dataset for lane-level RM mapping and it includes a total of 25157 pixel-wise annotated images and 21000 position labeled images.Finally,the proposed lane-level map building method is applied to SeRM set and its validity is demonstrated through experimentation.展开更多
BACKGROUND Most complex renal stones are managed primarily with percutaneous nephrolithotomy(PCNL).However,PCNL is still a great challenge for surgeons because of poor comprehension on complex adjacent structures.Nove...BACKGROUND Most complex renal stones are managed primarily with percutaneous nephrolithotomy(PCNL).However,PCNL is still a great challenge for surgeons because of poor comprehension on complex adjacent structures.Novel techniques are required to assist in planning and navigation.AIM To apply and evaluate the Hisense computer-assisted surgery(CAS)system in PCNL.METHODS A total of 60 patients with complex renal stones were included.Thirty patients in the CAS group had three-dimensional(3 D)virtual models constructed with the CAS system.The model assisted in planning and navigating in the CAS system.Thirty patients in the control group planned and navigated as standard PCNL,without the application of the CAS system.Success rate of one attempt,operation time,initial stone-free rate,decrease in hemoglobin,and complications were collected and analyzed.RESULTS There were no statistically significant differences in the baseline characteristics or planning characteristics.The success rate of one puncturing attempt(90%vs 67%,P=0.028)and the initial stone-free rate(87%vs 63%,P=0.037)were significantly higher in the CAS group.However,there were no statistically significant differences in the operation time(89.20±29.60 min vs 92.33±33.08 min,P=0.859)or in the decrease in hemoglobin(11.07±8.32 g/L vs 9.03±11.72 g/L,P=0.300)between the CAS group and the control group.No statistically significant differences in the incidence of complications(Clavien-Dindo grade≥2)were found.CONCLUSION Compared with standard PCNL,CAS-assisted PCNL had advantages in terms of the puncturing success rate and stone-free rate.The Hisense CAS System was recommended to assist in preoperative planning and intraoperative navigation for an intuitive,precise and convenient PCNL.展开更多
To improve the weak corrosion resistance of silicon steel to acid solution and alkaline solution with high temperature,a stable hierarchical micro/nanostructure superhydrophobic surface with myriad irregular micro-sca...To improve the weak corrosion resistance of silicon steel to acid solution and alkaline solution with high temperature,a stable hierarchical micro/nanostructure superhydrophobic surface with myriad irregular micro-scale hump and sheet-like nanostructure was successfully prepared on silicon steel by a simple,efficient and facile operation in large-area laser marking treatment.The morphology,composition,wettability of the as-prepared surface were studied.The superhydrophobic performance of the surface was investigated as well.Additionally,the corrosion resistance of the superhydrophobic surface to acidic solutions at room temperature and alkaline solutions at high temperature (80 ℃) was carefully explored.The corrosion resistance mechanism was clarified.Moreover,considering the practical application of the surface in the future,the hardness of the hierarchical micro/nanostructure superhydrophobic surface was studied.The experimental results indicate that the hierarchical micro/nanostructure surface with texture spacing of 100 μm treated at laser scanning speed of 100 mms/ presents superior superhydrophobicity after decreasing surface energy.The contact angle can be as high as 156.6°.Additionally,the superhydrophobic surface provide superior and stable anticorrosive protection for silicon steel in various corrosive environments.More importantly,the prepared structure of the surface shows high hardness,which ensures that the surface of the superhydrophobic surface cannot be destroyed easily.The surface is able to maintain great superhydrophobic performance when it suffers from slight impacting and abrasion.展开更多
In order to assess the effect of enhancement release of chum salmon(Oncorhynchus keta),otolith strontium(Sr)marking method was used to tag chum salmon released in Tangwang River in 2016.The homing chum salmon were det...In order to assess the effect of enhancement release of chum salmon(Oncorhynchus keta),otolith strontium(Sr)marking method was used to tag chum salmon released in Tangwang River in 2016.The homing chum salmon were detected and the samples were collected in Tangwang River,Ussuri River and Suifen River in the autumn of2018.The samples were analyzed by examining Sr and calcium(Ca)fingerprints in the otolith using electron probe microanalysis.The results suggested that two samples collected in Tangwang River had the marking ring near the core of otolith where the Sr concentration and Sr/Ca ratio were significantly higher than comparative samples.Proving that the two fish belonged to the released population in Tangwang River in 2016.This article indicated the success of the enhancement release of chum salmon from the Tangwang River for the first time and also confirmed the validity of Sr marking in enhancement release of fishes.展开更多
This paper describes a novel algorithm for fragile watermarking of 3D models. Fragile watermarking requires detection of even minute intentional changes to the 3D model along with the location of the change. This pose...This paper describes a novel algorithm for fragile watermarking of 3D models. Fragile watermarking requires detection of even minute intentional changes to the 3D model along with the location of the change. This poses a challenge since inserting random amount of watermark in all the vertices of the model would generally introduce perceptible distortion. The proposed algorithm overcomes this challenge by using genetic algorithm to modify every vertex location in the model so that there is no perceptible distortion. Various experimental results are used to justify the choice of the genetic algorithm design parameters. Experimental results also indicate that the proposed algorithm can accurately detect location of any mesh modification.展开更多
This study explores the reasons underlying the frequent appearance of "marking problem" during the production of double-walled copper-brazed steel tubes. To this end, we compared two types of copper-coated steel str...This study explores the reasons underlying the frequent appearance of "marking problem" during the production of double-walled copper-brazed steel tubes. To this end, we compared two types of copper-coated steel strips, of which one has almost no problem during production, whereas the other has higher number of incidences of "marking problem". We analyzed the chemical composition,mechanical properties,the cross-sectional metallographs, and surface quality of the trimmed edge in both types of specimen. After the roll forming process, the bonding condition between the steel layers of the tubes before and after brazing process has also been examined. Results indicate that the chemical composition and mechanical properties of the two kinds of strips are similar; however, the edge quality of the trimmed strips is significantly different. It is believed that the irregular shape of the edge portions in the strips will be more pronounced during the bevel treatment. Consequently, smooth and tight seams cannot be guaranteed by such uneven beveled edges,which lead to higher number of incidences of "marking problem" during production.展开更多
Laser marking is a laser processing technology used in many fields of industry like automotive [1], aerospace [2], microelectronic [3] and medecine [4]. CO2 laser is an appropriate source for marking glasses [5]. Comp...Laser marking is a laser processing technology used in many fields of industry like automotive [1], aerospace [2], microelectronic [3] and medecine [4]. CO2 laser is an appropriate source for marking glasses [5]. Compared to the other techniques of marking, the principal advantages of the use of the laser are: made inalterable, high degree of accuracy and the smoothness of the features, the possibility of marking at difficult to reach places, and the fact of being able to mark fragile materials like ceramic and glass [6]. In this experimental work, the influence of marking parameters like interaction time laser-glass, laser power, shooting time etc. on the micromarking precision are reported. A “melt” depth prediction model has been established.展开更多
BACKGROUND Congenital maxillomandibular syngnathia is an extremely rare disorder characterized by craniofacial malformations and inability to open the mouth adequately, which leads to problems with feeding, swallowing...BACKGROUND Congenital maxillomandibular syngnathia is an extremely rare disorder characterized by craniofacial malformations and inability to open the mouth adequately, which leads to problems with feeding, swallowing, and breathing as well as temporomandibular joint ankylosis. The main goal of the surgery is to release the ankylosis, establish functioning mandible, and prevent re-fusion.However, surgical procedures for this disease are rarely reported.CASE SUMMARY Here, we report a 7-mo-old girl with bilateral maxillomandibular syngnathia. The patient presented with difficulty in feeding, breathing, sounding, and swallowing and had developmental dysplasia. For treatment, we performed bone isolation by computer-assisted navigation and used silicone to fix the wound surface to prevent refusion of bone. To our knowledge, this is the only syngnathia case in the literature treated using computer-assisted navigation. With the guidance of precise navigation, we were able to minimize operation time by at least one hour,the patient's blood vessels, nerves, and tooth germs were well protected, and excessive bleeding was avoided. After six weeks, the patient showed improvement in mouth opening and no major issues of feeding.CONCLUSION Application of computer-assisted navigation can significantly improve accuracy,effectiveness, and surgical safety in correcting congenital maxillomandibular syngnathia.展开更多
基金Supported by National Natural Science Foundation of China,No.82293665Anhui Provincial Department of Education University Research Project,No.2023AH051763.
文摘BACKGROUND The management of hepatoblastoma(HB)becomes challenging when the tumor remains in close proximity to the major liver vasculature(PMV)even after a full course of neoadjuvant chemotherapy(NAC).In such cases,extreme liver resection can be considered a potential option.AIM To explore whether computer-assisted three-dimensional individualized extreme liver resection is safe and feasible for children with HB who still have PMV after a full course of NAC.METHODS We retrospectively collected data from children with HB who underwent surgical resection at our center from June 2013 to June 2023.We then analyzed the detailed clinical and three-dimensional characteristics of children with HB who still had PMV after a full course of NAC.RESULTS Sixty-seven children diagnosed with HB underwent surgical resection.The age at diagnosis was 21.4±18.8 months,and 40 boys and 27 girls were included.Fifty-nine(88.1%)patients had a single tumor,39(58.2%)of which was located in the right lobe of the liver.A total of 47 patients(70.1%)had PRE-TEXT III or IV.Thirty-nine patients(58.2%)underwent delayed resection.After a full course of NAC,16 patients still had close PMV(within 1 cm in two patients,touching in 11 patients,compressing in four patients,and showing tumor thrombus in three patients).There were 6 patients of tumors in the middle lobe of the liver,and four of those patients exhibited liver anatomy variations.These 16 children underwent extreme liver resection after comprehensive preoperative evaluation.Intraoperative procedures were performed according to the preoperative plan,and the operations were successfully performed.Currently,the 3-year event-free survival of 67 children with HB is 88%.Among the 16 children who underwent extreme liver resection,three experienced recurrence,and one died due to multiple metastases.CONCLUSION Extreme liver resection for HB that is still in close PMV after a full course of NAC is both safe and feasible.This approach not only reduces the necessity for liver transplantation but also results in a favorable prognosis.Individualized three-dimensional surgical planning is beneficial for accurate and complete resection of HB,particularly for assessing vascular involvement,remnant liver volume and anatomical variations.
文摘BACKGROUND Subchorionic hematoma(SCH)is a common complication in early pregnancy characterized by the accumulation of blood between the uterine wall and the chorionic membrane.SCH can lead to adverse pregnancy outcomes such as miscarriage,preterm birth,and other complications.Early detection and accurate assessment of SCH are crucial for appropriate management and improved pregnancy outcomes.AIM To evaluate the diagnostic efficacy of virtual organ computer-assisted analysis(VOCAL)in measuring the volume ratio of SCH to gestational sac(GS)combined with serum progesterone on early pregnancy outcomes in patients with SCH.METHODS A total of 153 patients with SCH in their first-trimester pregnancies between 6 and 11 wk were enrolled.All patients were followed up until a gestational age of 20 wk.The parameters of transvaginal two-dimensional ultrasound,including the circumference of SCH(Cs),surface area of SCH(Ss),circumference of GS(Cg),and surface area of GS(Sg),and the parameters of VOCAL with transvaginal three-dimensional ultrasound,including the three-dimensional volume of SCH(3DVs)and GS(3DVg),were recorded.The size of the SCH and its ratio to the GS size(Cs/Cg,Ss/Sg,3DVs/3DVg)were recorded and compared.RESULTS Compared with those in the normal pregnancy group,the adverse pregnancy group had higher Cs/Cg,Ss/Sg,and 3DVs/3DVg ratios(P<0.05).When 3DVs/3DVg was 0.220,the highest predictive performance predicted adverse pregnancy outcomes,resulting in an AUC of 0.767,and the sensitivity,specificity were 70.2%,75%respectively.VOCAL measuring 3DVs/3DVg combined with serum progesterone gave a diagnostic AUC of 0.824 for early pregnancy outcome in SCH patients,with a high sensitivity of 82.1%and a specificity of 72.1%,which showed a significant difference between AUC.CONCLUSION VOCAL-measured 3DVs/3DVg effectively quantifies the severity of SCH,while combined serum progesterone better predicts adverse pregnancy outcomes.
基金The Humanities and Social Sciences Project granted from the Ministry of Education in China(No.10YJA740061,11YJA740121)the Teaching Reform Key Project under Educational Section of Jiangsu Province(No.2011JSJG453)+3 种基金Southeast University Teaching Reform Project for Graduates(No.2010-54)Southeast University Teaching Reform Project for Post-Graduates(No.KJGKT12-06)the Natural Science Foundation of Jiangsu Province(No.BK2008354)the National Natural Science Foundation of China(No.6550181821,60975017)
文摘This paper discusses the approach to the CET (college English test) oral test based on automatic essay marking (AEM). The reliability and validity arouses a dispute on Internet-based CET (iB-CET) oral test in China, leading to the penetration into oral test contents in dialogue, description or comment, and question answering. Then, a probe into transformation from a spoken document into a textual document is touched on a conversion ratio of 72% adopted at the present time, AEM to be carried forward being a necessary hypothesis for Afterwards, this paper focuses on the pipeline in AEM with the content features and the language itself, which is established in two different models in marking for extraction and detection. Through experiments, this paper reveals the fact that an iB-CET oral test can be performed perfectly in the pipeline of spoken documents transformed into textual documents which can be automatically marked. Hence the design of the iB-CET oral test reaches its reliability and validity.
基金the National Natural Science Foundation of China(No.51675036)the Innovation and Development Project of Intelligent Manufacturing Technique from Beijing Municipal Science and Technology Commission(No.Z161100001516012).
文摘The computer-assisted surgery (CAS)has significantly improved the accuracy, reliability and outcomes of traumatic,spinal,nerve surgery and many other operations with a less invasive way.The application of CAS for scaphoid fractures remains experimental.The related studies are scanty and most of them are cadaver researches.Some intrinsic defects from the registration procedure,scan and immobilization of limbs may inevitably result in deviations. Some deviations become more obvious with operations of small bones (such as scaphoid)although they are acceptable for spine and other orthopedic surgeries.We reviewed the current literatures on the applications of CAS for scaphoid operation and summarized technical principles,scan and registration methods,immobilization of limbs and their outcomes.On the basis of the data,we analyzed the limitations of this technique and envisioned its future development.
基金the National Key R&D Program of China,No.2018YFC1313103the National Natural Science Foundation of China,No.81670473 and No.81873546+1 种基金the“Shu Guang”Project of Shanghai Municipal Education Commission and Shanghai Education Development Foundation,No.19SG30the Key Area Research and Development Program of Guangdong Province,China,No.2018B010111001.
文摘BACKGROUND Artificial intelligence in colonoscopy is an emerging field,and its application may help colonoscopists improve inspection quality and reduce the rate of missed polyps and adenomas.Several deep learning-based computer-assisted detection(CADe)techniques were established from small single-center datasets,and unrepresentative learning materials might confine their application and generalization in wide practice.Although CADes have been reported to identify polyps in colonoscopic images and videos in real time,their diagnostic performance deserves to be further validated in clinical practice.AIM To train and test a CADe based on multicenter high-quality images of polyps and preliminarily validate it in clinical colonoscopies.METHODS With high-quality screening and labeling from 55 qualified colonoscopists,a dataset consisting of over 71000 images from 20 centers was used to train and test a deep learning-based CADe.In addition,the real-time diagnostic performance of CADe was tested frame by frame in 47 unaltered full-ranged videos that contained 86 histologically confirmed polyps.Finally,we conducted a selfcontrolled observational study to validate the diagnostic performance of CADe in real-world colonoscopy with the main outcome measure of polyps per colonoscopy in Changhai Hospital.RESULTS The CADe was able to identify polyps in the test dataset with 95.0%sensitivity and 99.1%specificity.For colonoscopy videos,all 86 polyps were detected with 92.2%sensitivity and 93.6%specificity in frame-by-frame analysis.In the prospective validation,the sensitivity of CAD in identifying polyps was 98.4%(185/188).Folds,reflections of light and fecal fluid were the main causes of false positives in both the test dataset and clinical colonoscopies.Colonoscopists can detect more polyps(0.90 vs 0.82,P<0.001)and adenomas(0.32 vs 0.30,P=0.045)with the aid of CADe,particularly polyps<5 mm and flat polyps(0.65 vs 0.57,P<0.001;0.74 vs 0.67,P=0.001,respectively).However,high efficacy is not realized in colonoscopies with inadequate bowel preparation and withdrawal time(P=0.32;P=0.16,respectively).CONCLUSION CADe is feasible in the clinical setting and might help endoscopists detect more polyps and adenomas,and further confirmation is warranted.
文摘The aim of the present study was to compare assessments of sperm concentration and sperm motility analysed by conventional semen analysis with those obtained by computer-assisted semen analysis (CASA) (Copenhagen Rigshospitalet Image House Sperm Motility Analysis System (CRISMAS) 4.6 software) using semen samples from 166 young Danish men. The CRISMAS software identifies sperm concentration and classifies spermatozoa into three motility categories. To enable comparison of the two methods, the four motility stages obtained by conventional semen analysis were, based on their velocity classifications, divided into three stages, comparable to the three CRISMAS motility categories: rapidly progressive (A), slowly progressive (B) and non-progressive (C+ D). Differences between the two methods were large for all investigated parameters (P〈0.001). CRISMAS overestimated sperm concentration and the proportion of rapidly progressive spermatozoa and, consequently, underestimated the percentages of slowly progressive and non-progressive spermatozoa, compared to the conventional method. To investigate whether results drifted according to time of semen analysis, results were pooled into quarters according to date of semen analysis. CRISMAS motility results appeared more stable over time compared to the conventional analysis; however, neither method showed any trends. Apparently, CRISMAS CASA results and results from the conventional method were not comparable with respect to sperm concentration and motility analysis. This needs to be accounted for in clinics using this software and in studies of determinants of these semen characteristics.
文摘Glutathione peroxidase, the first example of selenoproteins identified in mammals, was subjected to force field calculations and molecular dynamics in order to enable a clearer comprehension of enzymatic selenium catalysis. Starting from the established X-ray structure of bovine GPX, all kinetically defined intermediates and enzyme substrate complexes were modelled. The models thus obtained support the hypothesis that the essential steps of the catalysis are three distinct redox changes of the active site selenium which, in the ground state, presents itself at the surface of selenoperoxidases as the center of a characteristic triad built by selenocysteine, glutarnine and tryptophan. In GPX, four arginine residues and a lysine residue provide an electrostatic architecture which, in each reductive step, directs the donor substrate GSH towards the catalytic center in such a way that 1ts sulfhydryl group must react with the selenium moiety. To this end, different equally efficient modes of substrate binding appear possible. The models are consistent with substrate specificity data, kinetic pattern and other functional characteristics of the enzyme. Comparison of molecular models of GPX with those of other members of the GPX superfamily reveals that the cosubstrate binding mechanisrns are unique for the classical type of cytosolic glutathione peroxidases but cannot operate e. g. in plasma GPX and phospholipid hydroperoxide GPX. The structural differences between the selenoperoxidases, shown to be relevant to their specificities, are discussed in terms of functional diversification within the GPX superfamily
基金funded by the National Natural Science Foundation of China (Grant Nos. 31601870 and 51435008)Natural Science Foundation of Jiangsu Province, China (Grant No. SBK20160800 to Zhouyi WANG)Jiangsu Provincial Key Laboratory of Bionic Functional Materials
文摘Animals have evolved a variety of behavior patterns to adapt to the environment. Motion-capture technology is utilized to quantify and characterize locomotor behaviors to reveal the mechanisms of animal motion. In the capture of flexible, small animals with complex locomotor behaviors, the markers interfere with each other easily, and the motion forms(bending, twisting) of the moving parts are obviously different;thus, it is a great challenge to realize accurate quantitative characterization of complex locomotor behaviors. The correlation between the marker properties, including the size and space length, and the precision of the system are revealed in this paper, and the effects of diverse marker shapes on the capturing accuracy of the captured objects in different motion forms were tested. Results showed that the precision of system is significantly improved when the ratio of the space length to the diameter of the markers is larger than four;for the capture of the spatial twisting motion of the flexible object, the hexagon markers had the lowest spatial lost-marker rate relative to the circle, triangle, and square. Customized markers were used to capture the locomotor behavior of the gecko-inspired robot(rigid connection) and the gecko(flexible connection). The results showed that this marking technology can achieve high accuracy of motion capture for geckos(the average deviation was approximately 0.32 mm, and the average deviation’s variation rate was approximately 0.96%). In this paper, the marking technology for the motion capture of flexible, small animals with complex motion is proposed;it can effectively improve the system precision as well as the capture accuracy, and realize the quantitative characterization of the complex motion of flexible, small objects. It provides a reliable technical means to deeply study the evolution of the motion function of small animals and advance systematic research of motion-capture technology.
基金Supported by the National Grand Fundamental Research 973 Program of China under Grant No. 2009CB320504the National High Technology Development 863 Program of China under Grant No.2007AA01Z206 and No.2009AA01Z210the EU FP7 Project EFIPSANS (INFSO-ICT-215549)
文摘Autonomic networking is one of the hot research topics in the research area of future network architectures.In this paper, we introduce context-aware and autonomic attributes into DiffServ QoS framework, and propose a novel autonomic packet marking(APM) algorithm.In the proposed autonomic QoS framework, APM is capable of collecting various QoS related contexts, and adaptively adjusting its behavior to provide better QoS guarantee according to users' requirements and network conditions.Simulation results show that APM provides better performance than traditional packet marker, and significantly improves user's quality of experience.
基金This work was supported by the Industry Core Technology Development Project,20005062Development of Artificial Intelligence Robot Autonomous Navigation Technology for Agile Movement in Crowded Space,funded by the Ministry of Trade,industry&Energy(MOTIE,Republic of Korea).
文摘The essential requirement for precise localization of a self-driving car is a lane-level map which includes road markings(RMs).Obviously,we can build the lane-level map by running a mobile mapping system(MMS)which is equipped with a high-end 3D LiDAR and a number of high-cost sensors.This approach,however,is highly expensive and ineffective since a single high-end MMS must visit every place for mapping.In this paper,a lane-level RM mapping system using a monocular camera is developed.The developed system can be considered as an alternative to expensive high-end MMS.The developed RM map includes the information of road lanes(RLs)and symbolic road markings(SRMs).First,to build a lane-level RM map,the RMs are segmented at pixel level through the deep learning network.The network is named RMNet.The segmented RMs are then gathered to build a lane-level RM map.Second,the lane-level map is improved through loop-closure detection and graph optimization.To train the RMNet and build a lane-level RM map,a new dataset named SeRM set is developed.The set is a large dataset for lane-level RM mapping and it includes a total of 25157 pixel-wise annotated images and 21000 position labeled images.Finally,the proposed lane-level map building method is applied to SeRM set and its validity is demonstrated through experimentation.
基金Supported by the Science and Technology Program in Chinese Medicine of Shandong Province,No.2020M074。
文摘BACKGROUND Most complex renal stones are managed primarily with percutaneous nephrolithotomy(PCNL).However,PCNL is still a great challenge for surgeons because of poor comprehension on complex adjacent structures.Novel techniques are required to assist in planning and navigation.AIM To apply and evaluate the Hisense computer-assisted surgery(CAS)system in PCNL.METHODS A total of 60 patients with complex renal stones were included.Thirty patients in the CAS group had three-dimensional(3 D)virtual models constructed with the CAS system.The model assisted in planning and navigating in the CAS system.Thirty patients in the control group planned and navigated as standard PCNL,without the application of the CAS system.Success rate of one attempt,operation time,initial stone-free rate,decrease in hemoglobin,and complications were collected and analyzed.RESULTS There were no statistically significant differences in the baseline characteristics or planning characteristics.The success rate of one puncturing attempt(90%vs 67%,P=0.028)and the initial stone-free rate(87%vs 63%,P=0.037)were significantly higher in the CAS group.However,there were no statistically significant differences in the operation time(89.20±29.60 min vs 92.33±33.08 min,P=0.859)or in the decrease in hemoglobin(11.07±8.32 g/L vs 9.03±11.72 g/L,P=0.300)between the CAS group and the control group.No statistically significant differences in the incidence of complications(Clavien-Dindo grade≥2)were found.CONCLUSION Compared with standard PCNL,CAS-assisted PCNL had advantages in terms of the puncturing success rate and stone-free rate.The Hisense CAS System was recommended to assist in preoperative planning and intraoperative navigation for an intuitive,precise and convenient PCNL.
基金the National Natural Science Foundation of China(No.51875425)。
文摘To improve the weak corrosion resistance of silicon steel to acid solution and alkaline solution with high temperature,a stable hierarchical micro/nanostructure superhydrophobic surface with myriad irregular micro-scale hump and sheet-like nanostructure was successfully prepared on silicon steel by a simple,efficient and facile operation in large-area laser marking treatment.The morphology,composition,wettability of the as-prepared surface were studied.The superhydrophobic performance of the surface was investigated as well.Additionally,the corrosion resistance of the superhydrophobic surface to acidic solutions at room temperature and alkaline solutions at high temperature (80 ℃) was carefully explored.The corrosion resistance mechanism was clarified.Moreover,considering the practical application of the surface in the future,the hardness of the hierarchical micro/nanostructure superhydrophobic surface was studied.The experimental results indicate that the hierarchical micro/nanostructure surface with texture spacing of 100 μm treated at laser scanning speed of 100 mms/ presents superior superhydrophobicity after decreasing surface energy.The contact angle can be as high as 156.6°.Additionally,the superhydrophobic surface provide superior and stable anticorrosive protection for silicon steel in various corrosive environments.More importantly,the prepared structure of the surface shows high hardness,which ensures that the surface of the superhydrophobic surface cannot be destroyed easily.The surface is able to maintain great superhydrophobic performance when it suffers from slight impacting and abrasion.
基金The Natural Science Foundation of Heilongjiang Province of China under contract No.YQ2019C034the Special Financial Funds of the Ministry of Agriculture and Rural Affairs under contract No.2130135。
文摘In order to assess the effect of enhancement release of chum salmon(Oncorhynchus keta),otolith strontium(Sr)marking method was used to tag chum salmon released in Tangwang River in 2016.The homing chum salmon were detected and the samples were collected in Tangwang River,Ussuri River and Suifen River in the autumn of2018.The samples were analyzed by examining Sr and calcium(Ca)fingerprints in the otolith using electron probe microanalysis.The results suggested that two samples collected in Tangwang River had the marking ring near the core of otolith where the Sr concentration and Sr/Ca ratio were significantly higher than comparative samples.Proving that the two fish belonged to the released population in Tangwang River in 2016.This article indicated the success of the enhancement release of chum salmon from the Tangwang River for the first time and also confirmed the validity of Sr marking in enhancement release of fishes.
文摘This paper describes a novel algorithm for fragile watermarking of 3D models. Fragile watermarking requires detection of even minute intentional changes to the 3D model along with the location of the change. This poses a challenge since inserting random amount of watermark in all the vertices of the model would generally introduce perceptible distortion. The proposed algorithm overcomes this challenge by using genetic algorithm to modify every vertex location in the model so that there is no perceptible distortion. Various experimental results are used to justify the choice of the genetic algorithm design parameters. Experimental results also indicate that the proposed algorithm can accurately detect location of any mesh modification.
文摘This study explores the reasons underlying the frequent appearance of "marking problem" during the production of double-walled copper-brazed steel tubes. To this end, we compared two types of copper-coated steel strips, of which one has almost no problem during production, whereas the other has higher number of incidences of "marking problem". We analyzed the chemical composition,mechanical properties,the cross-sectional metallographs, and surface quality of the trimmed edge in both types of specimen. After the roll forming process, the bonding condition between the steel layers of the tubes before and after brazing process has also been examined. Results indicate that the chemical composition and mechanical properties of the two kinds of strips are similar; however, the edge quality of the trimmed strips is significantly different. It is believed that the irregular shape of the edge portions in the strips will be more pronounced during the bevel treatment. Consequently, smooth and tight seams cannot be guaranteed by such uneven beveled edges,which lead to higher number of incidences of "marking problem" during production.
文摘Laser marking is a laser processing technology used in many fields of industry like automotive [1], aerospace [2], microelectronic [3] and medecine [4]. CO2 laser is an appropriate source for marking glasses [5]. Compared to the other techniques of marking, the principal advantages of the use of the laser are: made inalterable, high degree of accuracy and the smoothness of the features, the possibility of marking at difficult to reach places, and the fact of being able to mark fragile materials like ceramic and glass [6]. In this experimental work, the influence of marking parameters like interaction time laser-glass, laser power, shooting time etc. on the micromarking precision are reported. A “melt” depth prediction model has been established.
基金Supported by Ninth People's Hospital affiliated to Shanghai Jiao Tong University,School of Medicine "Multi-Disciplinary Team" Clinical Research Project,No.201701011
文摘BACKGROUND Congenital maxillomandibular syngnathia is an extremely rare disorder characterized by craniofacial malformations and inability to open the mouth adequately, which leads to problems with feeding, swallowing, and breathing as well as temporomandibular joint ankylosis. The main goal of the surgery is to release the ankylosis, establish functioning mandible, and prevent re-fusion.However, surgical procedures for this disease are rarely reported.CASE SUMMARY Here, we report a 7-mo-old girl with bilateral maxillomandibular syngnathia. The patient presented with difficulty in feeding, breathing, sounding, and swallowing and had developmental dysplasia. For treatment, we performed bone isolation by computer-assisted navigation and used silicone to fix the wound surface to prevent refusion of bone. To our knowledge, this is the only syngnathia case in the literature treated using computer-assisted navigation. With the guidance of precise navigation, we were able to minimize operation time by at least one hour,the patient's blood vessels, nerves, and tooth germs were well protected, and excessive bleeding was avoided. After six weeks, the patient showed improvement in mouth opening and no major issues of feeding.CONCLUSION Application of computer-assisted navigation can significantly improve accuracy,effectiveness, and surgical safety in correcting congenital maxillomandibular syngnathia.