期刊文献+
共找到8篇文章
< 1 >
每页显示 20 50 100
Combining TDLAS and multi-fusion algorithms for methane gas concentration detection
1
作者 SHI Guojun SONG Xinmin DONG Taiji 《Optoelectronics Letters》 EI 2024年第6期353-359,共7页
High-precision methane gas detection is of great importance in industrial safety, energy production and environmental protection, etc. However, in the existing measurement techniques, the methane gas concentration inf... High-precision methane gas detection is of great importance in industrial safety, energy production and environmental protection, etc. However, in the existing measurement techniques, the methane gas concentration information is susceptible to noise, which leads to its useful signal being drowned by noise. A fusion algorithm of variational modal decomposition(VMD) and improved wavelet threshold filtering is proposed, which is used in combination with tunable diode laser absorption spectroscopy(TDLAS) to implement a non-contact, high-resolution methane gas concentration detection. The fusion algorithm can perform noise reduction and further segmentation of the methane gas detection signal. And the simulation and experiment verify the effectiveness of the fusion algorithm, and the experimental results show that for the detection of air containing 10 ppm, 30 ppm, 60 ppm, 80 ppm, and 99 ppm methane, the errors are 12.75%, 8.18%, 3.37%, 2.46%, and 1.78%, respectively. 展开更多
关键词 Combining TDLAS and multi-fusion algorithms for methane gas concentration detection TDLAS
原文传递
Combined Transmission Interference Spectrum of No Core Fiber and BP Neural Network for Concentration Sensing Research 被引量:2
2
作者 Fang Wang Heng Lu +1 位作者 Yunpeng Li Yufang Liu 《Journal of Beijing Institute of Technology》 EI CAS 2017年第2期267-275,共9页
To investigate wavelength response of the no core fiber(NCF)interference spectrum to concentration,a three-layer back propagation(BP)neural network model was established to optimize the concentration sensing data.... To investigate wavelength response of the no core fiber(NCF)interference spectrum to concentration,a three-layer back propagation(BP)neural network model was established to optimize the concentration sensing data.In this method,the measured wavelength and the corresponding concentration were trained by a BP neural network,so that the accuracy of the measurement system was optimized.The wavelength was used as the training set and got into the input layer of the three layer BP network model which is used as the input value of the network,and the corresponding actual concentration value was used as the output value of the network,and the optimal network structure was trained.This paper discovers a preferable correlation between the predicted value and the actual value,where the former is approximately equal to the latter.The correlation coefficients of the measured and predicted values for a sucrose concentration were 1.000 89 and 1.003 94;similarly,correlations of0.999 51 and 1.018 8 for a glucose concentration were observed.The results demonstrate that the BP neural network can improve the prediction accuracy of the nonlinear relationship between the interference spectral data and the concentration in NCF sensing systems. 展开更多
关键词 no core fiber dislocation optical fiber BP neural network concentration detection interference spectrum
下载PDF
An all optical fiber gas sensor of NH3 and CO based on based on the spectral absorption and harmonic detection
3
作者 Liu Jin Yang Haima +1 位作者 Yan Chaochao Song Wanqing 《International English Education Research》 2014年第12期100-103,共4页
An all optical fiber gas sensor is presented to detect the concentration of NH3 and CO. Based on the spectral absorption, The wideband light source is used to reflect two narrowband spectra by fiber grating of differe... An all optical fiber gas sensor is presented to detect the concentration of NH3 and CO. Based on the spectral absorption, The wideband light source is used to reflect two narrowband spectra by fiber grating of different duty. and piezoelectric ceramics to obtain narrowband output light. The high sensitivity detection can be measured from the second harmonic signal. The two narrowband spectra are corresponding to the absorption spectra of NH3 and CO. Concentration detection are realized by the detection of variety of light intensity. Sensitivity is proved and cost is reduced. 展开更多
关键词 DISTRIBUTION Optical fiber sensor concentration detection
下载PDF
Investigating the minimum detectable activity concentration and contributing factors in airborne gamma-ray spectrometry 被引量:1
4
作者 Yi Gu Kun Sun +6 位作者 Liang-Quan Ge Yuan-Dong Li Qing-Xian Zhang Xuan Guan Wan-Chang Lai Zhong-Xiang Lin Xiao-Zhong Han 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2021年第10期30-38,共9页
In this study,the theory of minimum detectable activity concentration(MDAC)for airborne gamma-ray spectrometry(AGS)was derived,and the relationship between the MDAC and the intrinsic effi-ciency of a scintillation cou... In this study,the theory of minimum detectable activity concentration(MDAC)for airborne gamma-ray spectrometry(AGS)was derived,and the relationship between the MDAC and the intrinsic effi-ciency of a scintillation counter,volume,and energy res-olution of scintillation crystals,and flight altitude of an aircraft was investigated.To verify this theory,experi-mental devices based on NaI and CeBr 3 scintillation counters were prepared,and the potassium,uranium,and thorium contents in calibration pads obtained via the stripping ratio method and theory were compared.The MDACs of AGS under different conditions were calculated and analyzed using the proposed theory and the Monte Carlo method.The relative errors found via a comparison of the experimental and theoretical results were less than 4%.The theory of MDAC can guide the work of AGS in probing areas with low radioactivity. 展开更多
关键词 Airborne gamma-ray spectrometry(AGS) Minimum detectable activity concentration(MDAC) Sensitivity
下载PDF
Detection of Oxygen Based on Host-Guest Doped Room-Temperature Phosphorescence Material
5
作者 Zhang Wei Li Gengchen +6 位作者 Su Hao Dai Wenbo Sun Peng Shi Jianbing Tong Bina Cai Zhengxu Dong Yuping 《有机化学》 SCIE CAS CSCD 北大核心 2024年第8期2523-2529,共7页
Quantitative oxygen detection,especially at low concentrations,holds significant importance in the realms of biology,complex environments,and chemical process engineering.Due to the high sensitivity and rapid response... Quantitative oxygen detection,especially at low concentrations,holds significant importance in the realms of biology,complex environments,and chemical process engineering.Due to the high sensitivity and rapid response of the triplet excitons of phosphorescence to oxygen,pure organic room-temperature phosphorescence(RTP)materials have garnered widespread attention in recent years for oxygen detection.However,simultaneously achieving ultralong phosphorescence at room temperature and quantitative oxygen detection from pure organic host-guest doped materials poses challenges.The d ensely packed materials may decrease non-radiative decay to increase the phosphorescence,but are unsuitable for oxygen diffusion in oxygen detection.Herein,the oxygen sensitivity of host-guest doped RTP materials using 4-bromo-N,N-bis(4-(tertbutyl)phenyl)aniline(TPABuBr)as the host and 6-bromo-2-butyl-1H-benzo[de]isoquinoline-1,3(2H)-dione(NIBr)as the guest was developed.The doped material exhibits fluorescence-phosphorescence dual-emission behavior at room temperature.The tert-butyl groups in TPABuBr facilitate appropriate intermolecular spacing in the crystal state,enhancing oxygen permeability.Therefore,oxygen penetration can quench the phosphorescence emission.The observed linear relationship between the phosphorescence intensity of the doped material and the oxygen volume fraction conforms to the Stern-Volmer equation,suggesting its potential for quantitative analysis of oxygen concentration.The calculated limit of detection is 0.015%(φ),enabling the analysis of oxygen with a volume fraction of less than 2.5%(φ).Moreover,the doped materials demonstrate rapid response and excellent photostability,indicating their potential utility as oxygen sensors.This study elucidates the design and characteristics of NIBr/TPABuBr doped materials,highlighting their potential application in oxygen concentration detection and offering insights for the design of oxygen sensors. 展开更多
关键词 organic room-temperature phosphorescence host-guest doped strategy oxygen sensitive materials oxygen concentration detection
原文传递
Capability of Raman lidar for monitoring the variation of atmospheric CO_2 profile 被引量:4
6
作者 赵培涛 张寅超 +5 位作者 王莲 胡顺星 苏嘉 曹开法 赵曰峰 胡欢陵 《Chinese Physics B》 SCIE EI CAS CSCD 2008年第1期335-342,共8页
Lidar (Light detection and ranging) has special capabilities for remote sensing of many different behaviours of the atmosphere. One of the techniques which show a great deal of promise for several applications is Ra... Lidar (Light detection and ranging) has special capabilities for remote sensing of many different behaviours of the atmosphere. One of the techniques which show a great deal of promise for several applications is Raman scattering. The detecting capability, including maximum operation range and minimum detectable gas concentration is one of the most significant parameters for lidar remote sensing of pollutants. In this paper, based on the new method for evaluating the capabilities of a Raman lidar system, we present an evaluation of detecting capability of Raman lidar for monitoring atmospheric CO2 in Hefei. Numerical simulations about the influence of atmospheric conditions on lidar detecting capability were carried out, and a conclusion can be drawn that the maximum difference of the operation ranges caused by the weather conditions alone can reach about 0.4 to 0.5km with a measuring precision within 30ppmv. The range of minimum detectable concentration caused by the weather conditions alone can reach about 20 to 35 ppmv in vertical direction for 20000 shots at a distance of 1 km on the assumption that other parameters are kept constant. The other corresponding parameters under different conditions are also given. The capability of Raman lidar operated in vertical direction was found to be superior to that operated in horizontal direction. During practical measurement with the Raman lidar whose hardware components were fixed, aerosol scattering extinction effect would be a significant factor that influenced the capability of Raman lidar. This work may be a valuable reference for lidar system designing, measurement accuracy improving and data processing. 展开更多
关键词 Raman lidar atmospheric CO2 minimum detectable concentration
下载PDF
Design and development of a plastic scintillator based whole body β/γ contamination monitoring system 被引量:2
7
作者 Vaishali M.Thakur Amit Jain +4 位作者 P.Ashokkumar Rekha Anilkumar Pravin Sawant Probal Chaudhury L.M.Chaudhari 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2021年第5期33-42,共10页
Plastic scintillation detectors based whole body β/γ contamination monitors are developed for use in radiation facilities.This microcontroller-based multi-detector system uses 13 plastic scintillator detectors,with ... Plastic scintillation detectors based whole body β/γ contamination monitors are developed for use in radiation facilities.This microcontroller-based multi-detector system uses 13 plastic scintillator detectors,with minimized dead detection zones,monitoring the whole body,and conforming to the contamination limit prescribed by the regulatory authority.This system has the features for monitoring hands,feet,head,and faceβ/γusing contamination monitors and portal exit monitors.It can detect gamma sources at a dose rate of 10 n Gyh^(-1).The system is calibrated using b sources^(90)Sr/^(90)Y,^(204)Tl,and^(36)Cl,and the efficiency is found to be 29%,22%,and 18%,respectively.Theminimumdetectableβ/γcontaminationis0.15 Bqcm^(-2),which is significantly less than the minimum detection objectives on head,face,hands,and feet. 展开更多
关键词 Plastic scintillation detector Contamination monitor MICROCONTROLLER Minimum detection Objective(MDO) Minimum detection concentration(MDC)
下载PDF
Optimization of PGNAA set-up for the elements detection in aqueous solution 被引量:5
8
作者 JIA WenBao HEI DaQian +2 位作者 CHENG Can ZHANG HaoJia SHAN Qing 《Science China(Technological Sciences)》 SCIE EI CAS 2014年第3期625-629,共5页
A prompt gamma neutron activation analysis(PGNAA)set-up was developed for the elements detection in aqueous solution,which includes a 241Am-Be neutron source and a 4-inch BGO detector.The geometry of set-up is determi... A prompt gamma neutron activation analysis(PGNAA)set-up was developed for the elements detection in aqueous solution,which includes a 241Am-Be neutron source and a 4-inch BGO detector.The geometry of set-up is determined by a series of simulations with the MOCA code to improve the efficiency of the elements detection.The thermal neutron flux and the gamma-ray self-absorption are considered during the optimization calculations.Experiments were performed to validate the set-up using samples including chlorine and mercury,respectively.The result shows that the characteristic peak count has linear relationship with the chlorine and mercury concentration changing.The minimum detectable concentrations of chlorine and mercury were found as 54 mg/L and 51.4 mg/L,respectively. 展开更多
关键词 PGNAA elements detection minimum detectable concentrations MOCA
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部