期刊文献+
共找到16篇文章
< 1 >
每页显示 20 50 100
低浓度碘对比剂在肥胖患者冠状动脉计算机断层扫描血管造影检查中的应用
1
作者 李燕奎 陈明东 +2 位作者 黄天勤 朱雪平 蒋盛平 《岭南心血管病杂志》 CAS 2024年第2期160-166,共7页
目的探究低浓度碘对比剂在肥胖患者低管电压冠状动脉检查中的应用。方法2020年8月至2021年5月前瞻性入选玉林市第一人民医院80例疑似冠状动脉粥样硬化性心脏病(冠心病)行冠状动脉计算机断层扫描血管造影(coronary computed tomography a... 目的探究低浓度碘对比剂在肥胖患者低管电压冠状动脉检查中的应用。方法2020年8月至2021年5月前瞻性入选玉林市第一人民医院80例疑似冠状动脉粥样硬化性心脏病(冠心病)行冠状动脉计算机断层扫描血管造影(coronary computed tomography angiography,CCTA)检查的肥胖患者。按随机数字表法分组,每组40例。高浓度组采用优维显浓度为370 mgI/mL,低浓度组采用优维显浓度为300 mgI/mL,均进行低管电压CCTA检查。比较两组患者图像的质量、辐射剂量、碘摄入量及注入率、注射对比剂外渗率、不适感及检查前后肾功能指标、对比剂肾病发生情况,并以数字减影血管造影(digital subtraction angiography,DSA)为“金标准”评价低浓度碘对比剂对中度及以上动脉血管狭窄的鉴别诊断价值。结果低浓度组患者的图像质量分值与高浓度组比较,差异无统计学意义[(4.29±0.37)分vs.(4.32±0.36)分,P>0.05],且2名医师对图像质量评估的一致性较高(P<0.05)。两组患者冠状动脉各节段计算机断层扫描(computed tomography,CT)值、对比噪声比(contrast-to-noise ratio,CNR)、信噪比(signal-to-noise ratio,SNR)及图像优良指数(figure of merit,FOM)比较,差异均无统计学意义(P>0.05)。两组患者容积CT剂量指数(volumetric CT dose index,CTDIvol)、有效剂量(effective dose,ED)及造影剂量比较,差异无统计学意义(P>0.05);低浓度组患者总碘用量及碘注入率均少于高浓度组,差异有统计学意义(P<0.05)。相较于治疗前,两组患者治疗后肾功能指标均有所上调,且低浓度组较高浓度组低,差异有统计学意义(P<0.05)。低浓度组患者注射对比剂热感、疼痛感及对比剂肾病发生率均低于高浓度组,差异有统计学意义(P<0.05)。以DSA检查为“金标准”,Kappa检验结果显示,低浓度碘对比剂与DSA诊断动脉血管狭窄程度的一致性较高(P<0.05),且低浓度对比剂对中度及以上动脉血管狭窄的诊断准确率为95.06%。结论低浓度对比剂应用在肥胖患者低管电压条件下行CCTA检查,在保证图像质量及诊断动脉血管狭窄准确率前提下,可明显减少碘摄入量,降低不良反应发生率,值得临床推广与应用。 展开更多
关键词 冠状动脉疾病 碘对比剂 低浓度 肥胖 低管电压 计算机断层扫描血管造影 动脉血管狭窄
下载PDF
双源CT“双低方案”在冠状动脉CT血管成像检查中的可行性研究 被引量:29
2
作者 章辉庆 邱晓晖 +2 位作者 刘艺超 夏俊立 刘海燕 《中国全科医学》 CAS 北大核心 2017年第9期1127-1131,共5页
目的探讨双源CT低管电压低对比剂浓度(双低方案)在冠状动脉CT血管成像(CTA)检查中的可行性。方法选择2014年9月—2015年6月在亳州市人民医院行冠状动脉CTA检查的50例临床疑似或确诊冠心病且体质指数(BMI)≤30.0 kg/m^2的患者,随机分成两... 目的探讨双源CT低管电压低对比剂浓度(双低方案)在冠状动脉CT血管成像(CTA)检查中的可行性。方法选择2014年9月—2015年6月在亳州市人民医院行冠状动脉CTA检查的50例临床疑似或确诊冠心病且体质指数(BMI)≤30.0 kg/m^2的患者,随机分成两组,A组采用管电压100 k V及320 mg I/ml碘克沙醇为对比剂;B组采用管电压80 k V及270 mg I/ml碘克沙醇为对比剂,每组25例。所有冠状动脉CTA检查由西门子第二代Definition Flash双源CT完成,扫描范围135 mm,采用自动m As技术,对比剂剂量50 ml,注射速率5.0 ml/s。对图像进行质量评分及客观评价。测量升主动脉(AO)根部的CT值及图像噪声,计算图像信噪比(SNR),测量并计算左冠状动脉主干(LM)、左冠状动脉前降支(LAD)近段、左冠状动脉回旋支(LCX)近段、右冠状动脉(RCA)近段的对比度噪声比(CNR)。记录两组的有效辐射剂量(ED)。结果两组图像质量评分及各血管段评分间差异无统计学意义(P>0.05)。B组AO、LM、LAD近段、LCX近段、RCA近段CT值高于A组(P<0.05)。B组的图像噪声大于A组(P<0.05);两组SNR及LM、LAD近段、LCX近段、RCA近段的CNR比较,差异均无统计学意义(P>0.05)。B组ED低于A组(P<0.05)。结论在80 k V、270 mg I/ml双低条件下行冠状动脉CTA检查,能明显降低对患者的ED及碘摄入量的同时,图像质量能够满足临床诊断要求;对于BMI≤30.0 kg/m^2的患者,行双源CT"双低方案"冠状动脉CTA检查具有可行性及临床借鉴意义。 展开更多
关键词 血管造影术 冠状动脉疾病 双源 体层摄影术 X线计算机 辐射剂量 碘对比剂 低浓度
下载PDF
低管电压、低浓度碘对比剂(双低)在头颈CTA检查中的应用 被引量:16
3
作者 王玉屏 王龙胜 +1 位作者 郑穗生 邹立巍 《安徽医科大学学报》 CAS 北大核心 2015年第5期683-686,共4页
目的探讨低管电压、低浓度碘对比剂(双低)在头颈CT血管造影(CTA)检查中的应用效果。方法选取60例行头颈CTA检查的健康志愿者作为研究对象,并随机分为双低组和常规组,每组30例,双低组采用低管电压、低浓度碘对比剂头颈CTA检查,常规组实... 目的探讨低管电压、低浓度碘对比剂(双低)在头颈CT血管造影(CTA)检查中的应用效果。方法选取60例行头颈CTA检查的健康志愿者作为研究对象,并随机分为双低组和常规组,每组30例,双低组采用低管电压、低浓度碘对比剂头颈CTA检查,常规组实施常规CTA检查,比较两组受检者的图像质量、CT值等级、辐射剂量等。结果双低组不同兴趣区(ROI)的CT值与常规组差异无统计学意义(P>0.05);双低组在右大脑中动脉、左大脑中动脉中的图像质量评分稍低于常规组(P<0.05);在其他ROI中,两组的图像质量评分比较,差异无统计学意义(P>0.05);两组图像质量的主观评分结果差异无统计学意义(P>0.05);双低组的体型特异性剂量估计值、剂量长度乘积值均显著低于常规组(P<0.05)。结论使用低管电压、低浓度对比剂进行头颈CTA检查,能够在不影响图像质量的基础上降低对比剂用量、减少辐射剂量,具有重要的推广应用价值。 展开更多
关键词 头颈CTA 低浓度碘对比剂 低管电压 辐射剂量
下载PDF
不同浓度碘对比剂应用于腹部血管CT的增强效能比较研究 被引量:3
4
作者 杨建华 刘亚龙 贾维 《中外医学研究》 2020年第36期58-60,共3页
目的:探讨不同浓度碘对比剂应用于腹部血管CT过程中的增强效能。方法:选取笔者所在医院于2018年11月-2019年11月收治并实施腹部血管CT检查的患者156例为研究对象,随机将患者分成A组、B组和C组,三组患者的碘总量设定为420 mgI/kg,碘注射... 目的:探讨不同浓度碘对比剂应用于腹部血管CT过程中的增强效能。方法:选取笔者所在医院于2018年11月-2019年11月收治并实施腹部血管CT检查的患者156例为研究对象,随机将患者分成A组、B组和C组,三组患者的碘总量设定为420 mgI/kg,碘注射率设定为1.2 gI/s,给予的碘对比剂浓度分别为270、320 mg/ml和370 mg/ml。对三组患者各层面腹主动脉和门静脉的CT值和医生评分情况,以及各层面腹主动脉和门静脉的信噪比和对比噪声比进行观察和比较。结果:三组患者各层面腹主动脉和门静脉的CT值和医生评分差异均无统计学意义(P>0.05);三组患者各层面腹主动脉和门静脉的信噪比和对比噪声比差异均无统计学意义(P>0.05)。结论:在碘总量和碘注射率总体控制的前提下,给予不同浓度的碘对比剂进行腹部血管CT均能取得较好的增强效能,各组之间的效果基本相当。 展开更多
关键词 不同浓度 碘对比剂 腹部血管CT 增强效能
下载PDF
64排CT“双低”扫描模式在颈部CTA检查中的应用研究 被引量:2
5
作者 侯青 《中外医疗》 2019年第4期193-195,共3页
目的探讨颈部CTA检查中进行64排CT "双低"扫描模式的应用研究。方法方便选择2015年6月—2016年2月来该院进行颈部CTA检查者90例,根据随机数字表法分为对照组和观察组,每组45例,观察组进行64排CT"双低"扫描模式,300 ... 目的探讨颈部CTA检查中进行64排CT "双低"扫描模式的应用研究。方法方便选择2015年6月—2016年2月来该院进行颈部CTA检查者90例,根据随机数字表法分为对照组和观察组,每组45例,观察组进行64排CT"双低"扫描模式,300 mgI/mL碘海醇对比剂,100 k V管电压,对照组进行常规64排CT扫描模式,即350 mgI/mL碘海醇对比剂,120 k V管电压,由两名资质较高的影像科医师评价图像质量,比较两组的对比噪声比(CNR)、信噪比(SNR)、噪声、CT值等临床指标情况;比较两组的颈部动脉血管1分节段、2分节段、3分节段、4分节段的图像质量情况。结果观察组的对比噪声比(CNR)、信噪比(SNR)、噪声、CT值等临床指标情况分别为(40.2±6.3)、(40.6±7.9)、(9.1±2.3)、(388.6±40.3)HU,对照组分别为(58.9±10.8)、(69.7±15.7)、(7.4±0.5)、(490.8±60.2)HU,差异有统计学意义(t=10.03,11.11,4.85,9.46,P<0.05);而观察组与对照组的颈部动脉血管1分节段、2分节段、3分节段、4分节段的图像质量比较,差异无统计学意义(P>0.05)。结论颈部CTA检查中应用64排CT"双低"扫描模式可显著降低患者所受的碘总量和辐射剂量,同时可获得较佳的图像质量。 展开更多
关键词 低浓度对比剂 低管电压 碘总量 辐射剂量 颈部CTA
下载PDF
不同碘浓度对比剂对冠脉CT血管造影图像质量的影响 被引量:6
6
作者 马燕辉 陈岩 +2 位作者 徐妍妍 孙宏亮 谢晟 《中日友好医院学报》 CAS 2021年第2期85-88,F0003,共5页
目的:比较2种不同碘浓度对比剂对冠脉CT血管造影(CTA)图像质量的影响。方法:回顾性分析门诊行冠脉CTA检查、体重<90kg且身体质量指数<30kg/m^(2)、未行冠脉支架植入术或搭桥术的患者,共97例。男45例、女52例;平均55.8±11.0... 目的:比较2种不同碘浓度对比剂对冠脉CT血管造影(CTA)图像质量的影响。方法:回顾性分析门诊行冠脉CTA检查、体重<90kg且身体质量指数<30kg/m^(2)、未行冠脉支架植入术或搭桥术的患者,共97例。男45例、女52例;平均55.8±11.0岁。根据所用对比剂不同(碘佛醇350mg I/ml或碘普罗胺370mg I/ml)分为2组。2组均采用对比剂和生理盐水双筒注射,流速5ml/s,对比剂总量75ml,生理盐水30ml。由2名放射科医师采用盲法对冠脉CTA图像质量进行评分(1~4分)及测量分析。比较2组间图像质量的差异。结果:2组间冠脉血管密度值不存在统计学差异(P>0.05),但采用1.8g I/s碘流率(IDR)校正后,碘佛醇组显著高于碘普罗胺组(P<0.05)。2组的平均图像质量得分、图像噪声、信噪比、对比噪声比均不存在统计学差异(均P>0.05)。结论:在相同对比剂注射方案下,不同浓度含碘对比剂(350mg I/ml vs.370mg I/ml)的冠脉CTA图像质量无明显的统计学差异,进行IDR校正后,相对低浓度对比剂组的血管密度值更高。 展开更多
关键词 冠脉CT血管造影 图像质量 对比剂 碘浓度
下载PDF
不同碘浓度对比剂对肝脏CT增强扫描静脉期图像质量的影响 被引量:5
7
作者 胡勤勤 张德川 +2 位作者 祝君 曾国飞 杨华 《局解手术学杂志》 2022年第11期1000-1004,共5页
目的探讨不同碘浓度对比剂对肝脏CT增强扫描静脉期图像质量的影响。方法纳入我院因肝肿瘤行3次及以上上腹部CT增强扫描检查的36例患者,同一患者3次检查分别采用碘浓度为370 mgI/mL、320 mgI/mL、270 mgI/mL的3种对比剂,分别设为370组、... 目的探讨不同碘浓度对比剂对肝脏CT增强扫描静脉期图像质量的影响。方法纳入我院因肝肿瘤行3次及以上上腹部CT增强扫描检查的36例患者,同一患者3次检查分别采用碘浓度为370 mgI/mL、320 mgI/mL、270 mgI/mL的3种对比剂,分别设为370组、320组、270组,每次对比剂总量均为1.2 mL/kg,注射速度均为3.5 mL/s。测量静脉期门静脉、静脉期肝静脉、静脉期肝实质及平扫肝实质CT值,计算静脉期门静脉与静脉期肝实质CT值差值(门静脉强化值)、静脉期肝静脉与静脉期肝实质CT值差值(肝静脉强化值)、静脉期肝实质CT值与平扫肝实质CT值差值(肝实质强化值)。比较3组间静脉期门静脉、静脉期肝静脉、静脉期肝实质及其强化值差异,并采用四级评分标准对图像质量进行目测评分。结果370组、320组、270组门静脉强化值分别为(48.90±17.98)Hu、(45.62±22.98)Hu、(37.38±14.48)Hu;370组、320组、270组肝静脉强化值分别为(45.57±20.61)Hu、(44.14±18.93)Hu、(36.38±21.10)Hu;370组、320组、270组肝实质强化值分别为(47.65±11.19)Hu、(46.92±13.29)Hu、(38.04±12.58)Hu。370组及320组静脉期肝实质及肝实质强化值均高于270组(P<0.05),370组和320组间差异无统计学意义(P>0.05)。370组、320组、270组图像质量评分分别为(3.50±0.70)分、(3.42±0.73)分和(3.03±0.88)分,370组静脉期图像质量明显优于320组及270组,270组静脉期图像质量最差。结论碘对比剂浓度对肝脏CT增强扫描静脉期图像质量具有重要影响,高浓度的对比剂能提升肝脏静脉的显影对比效果。 展开更多
关键词 X射线 对比剂 碘浓度 肝脏 图像质量
下载PDF
Value of liver computed tomography with iodixanol 270, 80 kVp and iterative reconstruction 被引量:5
8
作者 Diomidis Botsikas Isabelle Barnaure +3 位作者 Sylvain Terraz Christoph D Becker Anastasia Kalovidouri Xavier Montet 《World Journal of Radiology》 CAS 2016年第7期693-699,共7页
AIM: To evaluate the image quality of hepatic multidetector computed tomography(MDCT) with dynamic contrast enhancement. METHODS: It uses iodixanol 270 mg/m L(Visipaque 270) and 80 kVp acquisitions reconstructed with ... AIM: To evaluate the image quality of hepatic multidetector computed tomography(MDCT) with dynamic contrast enhancement. METHODS: It uses iodixanol 270 mg/m L(Visipaque 270) and 80 kVp acquisitions reconstructed with sinogram affirmed iterative reconstruction(SAFIRE?) in comparison with a standard MDCT protocol. Fiftythree consecutive patients with known or suspected hepatocellular carcinoma underwent 55 CT examinations, with two different four-phase CT protocols. The first group of 30 patients underwent a standard 120 kVp acquisition after injection of Iohexol 350 mg/m L(Accupaque 350~?) and reconstructed with filtered back projection. The second group of 25 patients underwent a dual-energy CT at 80-140 kVp with iodixanol 270. The 80 kVp component of the second group was reconstructed iteratively(SAFIRE?-Siemens). All hyperdense and hypodense hepatic lesions ≥ 5 mm were identified with both protocols. Aorta and portal vessels/liver parenchyma contrast to noise ratio(CNR) in arterial phase, hypervascular lesion/liver parenchyma CNR in arterial phase, hypodense lesion/liver parenchyma CNR in portal and late phase were calculated in both groups.RESULTS: Aorta/liver and focal lesions altogether/liver CNR were higher for the second protocol(P = 0.0078 and 0.0346). Hypervascular lesions/liver CNR was not statistically different(P = 0.86). Hypodense lesion/liver CNR in the portal phase was significantly higher for the second group(P = 0.0107). Hypodense lesion/liver CNR in the late phase was the same for both groups(P = 0.9926).CONCLUSION: MDCT imaging with 80 kVp with iterative reconstruction and iodixanol 270 yields equal or even better image quality. 展开更多
关键词 Multiphasic dynamic LIVER COMPUTED TOMOGRAPHY Low-kVp COMPUTED TOMOGRAPHY Iso-osmolar iodinE contrast agent Low iodinE concentration contrast agent Iterative reconstruction
下载PDF
心脏CT血管成像中碘对比剂浓度对肥胖病人冠状动脉检查图像质量、肾功能及碘用量的影响 被引量:1
9
作者 章爱华 高文霞 姚世文 《安徽医药》 CAS 2023年第9期1800-1803,共4页
目的探讨心脏CT血管成像(CTA)中不同碘对比剂浓度对肥胖病人冠状动脉检查图像质量、不良反应发生率及碘用量的影响。方法选取2021年1月至2022年3月如皋市人民医院100例行心脏CTA检查的肥胖冠心病病人,以抽签法随机分为两组,各50例。对照... 目的探讨心脏CT血管成像(CTA)中不同碘对比剂浓度对肥胖病人冠状动脉检查图像质量、不良反应发生率及碘用量的影响。方法选取2021年1月至2022年3月如皋市人民医院100例行心脏CTA检查的肥胖冠心病病人,以抽签法随机分为两组,各50例。对照组CTA检查中碘对比剂浓度为370 mgI/mL,研究组CTA检查中碘对比剂浓度为350 mgI/mL。比较两组图像质量、图像CT值、对比剂参数、肾功能指标。结果研究组图像质量评分及各血管段评分与对照组比较,差异无统计学意义(P>0.05);研究组噪声(30.25±4.12)低于对照组(40.78±8.37),差异有统计学意义(P<0.05),两组信噪比及对比噪声比(CNR)、图像CT值比较,差异无统计学意义(P>0.05);研究组碘摄入量(17.44±2.14)g,低于对照组的(126.33±2.37)g,差异有统计学意义(P<0.05),研究组对比剂总量、注射流率、碘流率低于对照组,差异有统计学意义(P<0.05);两组检查后肾功能指标比较,差异无统计学意义(P>0.05)。结论与高浓度碘对比剂比较,肥胖病人行心脏CTA检查中采用低浓度碘对比剂在保障图像质量的前提下能降低噪声,且能减少对比剂总量和碘摄入量,具有可行性及临床借鉴意义。 展开更多
关键词 冠状血管造影术 冠心病 肥胖 CT血管成像 碘对比剂 浓度 图像质量
下载PDF
不同浓度碘对比剂的腹部CT增强图像质量比较 被引量:2
10
作者 梁瑞鹏 石娇阳 +3 位作者 张莹 李永隆 周军 张秀富 《影像研究与医学应用》 2022年第16期10-12,共3页
目的:比较两种不同浓度碘对比剂的腹部计算机断层扫描(computed tomography,CT)增强图像质量,从应用不同浓度对比剂角度探索个性化扫描方案。方法:选取2020年10月—2021年8月期间于重庆大学附属江津医院接受腹部CT增强检查的100例患者... 目的:比较两种不同浓度碘对比剂的腹部计算机断层扫描(computed tomography,CT)增强图像质量,从应用不同浓度对比剂角度探索个性化扫描方案。方法:选取2020年10月—2021年8月期间于重庆大学附属江津医院接受腹部CT增强检查的100例患者为研究对象,根据选用碘对比剂浓度的不同分为高浓度组(碘海醇组350 mgI/mL,n=59)和低浓度组(碘克沙醇组300 mgI/mL,n=41),统计分析两组患者一般统计学资料、静脉期与平扫期强化差值、主观评分、信噪比、对比噪声比参数和不良事件发生情况。结果:两组患者的一般统计学资料均不存在显著差异(P> 0.05),两组患者均无不良事件发生。高浓度组平扫期与静脉期强化差值为(67.07±15.43)HU、主观评分为(3.34±0.66)分、信噪比为(6.0±1.9)、对比噪声比为(14.68±3.13);低浓度组平扫期与静脉期强化差值为(56.47±16.13) HU、主观评分为(2.83±0.63)分、信噪比为(5.61±2.26)、对比噪声比为(14.74±3.45),两组患者强化差值、主观评分差异存在统计学意义(P <0.05);信噪比、对比噪声比不存在显著差异(P> 0.05)。结论:没有明显的碘对比剂不良反应临床指征时,腹部CT增强检查选择高浓度碘对比剂能够为临床提供较好的影像图像。 展开更多
关键词 碘对比剂 浓度 腹部 计算机断层扫描 图像质量
下载PDF
64排MDCT不同碘对比剂浓度对原发性肝癌血流灌注参数的影响及临床意义探索 被引量:4
11
作者 杨云飞 谢毅 焦成文 《肝脏》 2020年第11期1175-1177,共3页
目的初步分析64排MDCT不同碘对比剂浓度对原发性肝癌血流灌注参数的影响,并探讨其临床意义,为原发性肝癌患者影像学结果诊断的进一步精确化及碘对比剂使用的安全性评估提供参考依据。方法于2017年2月至2018年3月,采用病例抽样的方法抽... 目的初步分析64排MDCT不同碘对比剂浓度对原发性肝癌血流灌注参数的影响,并探讨其临床意义,为原发性肝癌患者影像学结果诊断的进一步精确化及碘对比剂使用的安全性评估提供参考依据。方法于2017年2月至2018年3月,采用病例抽样的方法抽取上海市海军特色医学中心消化内科及肿瘤科收治的原发性肝癌患者,在征得患者及其家属同意的前提下将所有入选患者随机等额分配至不同碘对比剂浓度组[A组为300 mg I/mL(1.90 mL/kg),B组为380 mg I/mL(1.50 mL/kg)]并行多排螺旋CT检查,同时分析不同碘对比剂浓度组CT检测结果及与肝癌血流参数间的关系。结果高碘对比剂浓度组的肝实质门脉期CT值、主动脉动脉期CT值、门静脉门脉期CT值、动脉期检出敏感性均显著高于低碘对比剂浓度组,而肝血流量(BF)、肝血容量(BV)、肝动脉灌注量(HAP)均显著低于低碘对比剂浓度组(均有P<0.05)。结论较高碘对比剂浓度[380 mg I/mL(1.50 mL/kg)]组在64排MDCT检测原发性肝癌过程中有更好的敏感性,同时该组对应的血流灌注各项参数提示患者的肝动脉及门静脉的压力值均相对较低,但二者间的因果关系需进一步验证。 展开更多
关键词 64排MDCT 碘对比剂浓度 原发性肝癌 血流灌注参数
下载PDF
不同碘浓度对比剂对头部CT动脉成像质量的影响研究 被引量:1
12
作者 谭强 《吉林医学》 CAS 2016年第11期2643-2645,共3页
目的:在头部CT动脉成像检查过程中应用不同碘浓度对比剂后会得到不同效果的成像,本次探究的主要目的就是探究对比剂浓度对成像质量的影响。方法:选取接诊的101例患者,经随机数字法随机分成A、B、C三组,对三组患者采用不同浓度的对比剂,... 目的:在头部CT动脉成像检查过程中应用不同碘浓度对比剂后会得到不同效果的成像,本次探究的主要目的就是探究对比剂浓度对成像质量的影响。方法:选取接诊的101例患者,经随机数字法随机分成A、B、C三组,对三组患者采用不同浓度的对比剂,比较分析扫描检查的结果。结果:A、B、C三组的对比剂浓度不断升高,颈内动脉CT值、基底动脉CT值不断增大,成像的质量越来越高;A、B、C三组出现不良反应的概率分别为9.09%、20.59%及35.29%,C组最高且明显高于A组,差异具有统计学意义(P<0.05)。结论:对比剂的浓度是影响检查扫描质量的主要因素,其浓度越高扫描质量越好但是患者出现的不良反应越多,因此应把握对比剂的使用浓度。 展开更多
关键词 碘浓度 对比剂 部CT动脉成像
下载PDF
不同碘浓度对比剂在肾脏MSCT扫描中的作用 被引量:1
13
作者 石朋 《中国继续医学教育》 2019年第16期81-83,共3页
目的针对不同碘浓度对比剂在进行肾脏MSCT扫描中的效果进行分析。方法在本院2016年1月—2017年10月期间,随机对46例疑似患有肾脏疾病的患者进行研究,其中23例患者采用浓度为300mgI/mL的对比剂,记为对比组,剩下23例患者采用浓度为400 mgI... 目的针对不同碘浓度对比剂在进行肾脏MSCT扫描中的效果进行分析。方法在本院2016年1月—2017年10月期间,随机对46例疑似患有肾脏疾病的患者进行研究,其中23例患者采用浓度为300mgI/mL的对比剂,记为对比组,剩下23例患者采用浓度为400 mgI/mL的对比剂,记为观察组,对两组患者进行肾脏MSCT扫描,对比不同时间下,两组患者各项指标的MSCT强化值。结果观察组患者采用400 mgI/mL的对比剂进行MSCT扫描后,各项数据的增强效果均要高于对比组(P<0.05)。结论针对不同碘浓度对比剂在进行肾脏MSCT扫描后,高浓度的碘对比剂的效果要优于标准浓度的碘对比剂,在临床医学中,可根据患者的病情适当加大碘对比剂的浓度,增强其在扫描中的作用。 展开更多
关键词 碘浓度 肾脏疾病 MSCT 扫描 对比剂 临床价值 增强效果
下载PDF
低kVp、低浓度对比剂在双下肢CTA中的应用价值 被引量:5
14
作者 李林坤 褚玉静 +2 位作者 孙积宁 王文娟 耿海 《临床放射学杂志》 CSCD 北大核心 2018年第6期1047-1050,共4页
目的探讨低kVp、低浓度对比剂在双下肢动脉CT血管造影(CTA)中的应用价值。方法搜集临床怀疑下肢动脉疾病的患者136例,随机分成两组:A组68例应用肘静脉注射常用浓度(350 mg I/ml)对比剂90-100ml,进行常规CT扫描(120 kVp);B组68例... 目的探讨低kVp、低浓度对比剂在双下肢动脉CT血管造影(CTA)中的应用价值。方法搜集临床怀疑下肢动脉疾病的患者136例,随机分成两组:A组68例应用肘静脉注射常用浓度(350 mg I/ml)对比剂90-100ml,进行常规CT扫描(120 kVp);B组68例患者应用肘静脉注射低浓度(270 mgI/ml)对比剂90-100 ml,进行低k Vp CT扫描(100 kVp),两组均采用噪声指数(NI)为11的CARE Dose 4D自动mA调节技术;两组纳入条件均为体质量指数(BMI)〈25。主观图像质量评估由两名从事心血管影像诊断20年以上的专家进行盲法审阅,并对血管成像质量达成一致。两组图像的客观质量利用检测股动脉、大收肌的CT值,图像噪声(SD),对比噪声比(CNR)来判断。统计两组的辐射剂量例如平均CT容积剂量指数(CTDIvol),CNR和对比剂注射量。结果 A、B两组图像质量优良率分别为92.6%、91.2%,图像质量评分分别为:(3.6±0.6)分、(3.7±0.6)分;CTDIvol分别为(6.0±0.8)mGy、(4.0±0.9)mGy;对比剂注射剂量分别为(31.5±1.5)g、(26.7±1.6)g;有效mA分别为:(76.3±8.1)mA、(81.8±8.8)m ;SD分别为:10.0±1.7、11.6±2.4;CNR分别为:28.6±6.9、29.7±6.1。B组较A组CNR差异没有统计学意义(t=0.72,P=0.47)。B组较A组对比剂注射剂量差异具有统计学意义(t=18.47,P=0.00)。B组较A组CTA成像质量差异没有统计学意义(t=0.92,P=0.36)。B组较A组CTDIvol明显降低(t=13.91,P=0.00),平均降低了33.3%。结论在下肢动脉CTA时,管电压100 kVp、自动mA、270 mgI/ml浓度对比剂,可以替代管电压120 kVp,自动mA、350 mgI/ml浓度对比剂的CTA,在碘对比剂注射量减少的情况下,辐射剂量明显下降。 展开更多
关键词 常用浓度碘对比剂 低浓度碘对比剂 低剂量 低辐射 血管成像
原文传递
64排MDCT检查中不同浓度碘对比剂对高龄肝硬化肝癌患者诊断价值与安全性 被引量:7
15
作者 唐啸 程若勤 简纪华 《中国临床研究》 CAS 2017年第8期1039-1042,共4页
目的探究不同浓度碘对比剂在64排多排螺旋CT(MDCT)中对高龄肝硬化肝癌患者的诊断价值与安全性。方法选取2014年1月至2015年12月收治的80例高龄肝硬化肝癌患者,采用随机数字表法将患者均分为A组和B组,每组40例,两组患者均行平扫和增强扫... 目的探究不同浓度碘对比剂在64排多排螺旋CT(MDCT)中对高龄肝硬化肝癌患者的诊断价值与安全性。方法选取2014年1月至2015年12月收治的80例高龄肝硬化肝癌患者,采用随机数字表法将患者均分为A组和B组,每组40例,两组患者均行平扫和增强扫描,A组使用370 mg I/ml的优维显增强,B组使用300 mg I/ml的优维显增强,均注射100 ml,注射速度均为3.0 ml/s。测量两组患者增强肝实质、主动脉、门静脉的CT值,并统计两组患者病灶检出结果和两组患者不良反应发生情况。结果 A组患者增强后的肝实质CT值在门脉期、延迟期均明显高于B组(P均<0.05),A组主动脉CT值在动脉期明显高于B组(P<0.05),A组门静脉CT值在门脉期、延迟期均明显高于B组(P均<0.05);80例患者检出肝癌病灶236个,所有病灶动脉期和门脉期的诊断敏感性A组高于B组(P<0.05);两组患者的不良反应总发生率无统计学差异(P>0.05)。结论在高龄肝硬化肝癌患者的MDCT扫描中,高浓度对比剂在肝实质、主动脉、门静脉中能产生更高的CT值,且高浓度对比剂在动脉期和门脉期亦能提高肝癌的检出率,安全性与低浓度对比剂相似。 展开更多
关键词 对比剂碘浓度 多排螺旋CT 肝硬化肝癌 诊断价值
原文传递
不同浓度碘对比剂对乳腺导管造影图像质量的影响 被引量:2
16
作者 赵瑾 黄林 袁元 《华西医学》 CAS 2016年第7期1247-1250,共4页
目的探讨乳腺导管造影中不同浓度碘对比剂对图像质量的影响。方法选择2008年6月-2009年10月50例非妊娠哺乳期的乳头溢液患者行数字平板X线成像(DR)的乳腺导管造影检查。将患者的左乳设为L组,右乳设为R组。L组使用碘离子浓度为370 mg/m ... 目的探讨乳腺导管造影中不同浓度碘对比剂对图像质量的影响。方法选择2008年6月-2009年10月50例非妊娠哺乳期的乳头溢液患者行数字平板X线成像(DR)的乳腺导管造影检查。将患者的左乳设为L组,右乳设为R组。L组使用碘离子浓度为370 mg/m L的碘帕醇注射液,R组使用碘离子浓度为300 mg/m L的碘帕醇注射液。对两组图像进行质量评分和平均密度评估。结果 L组和R组的图像质量评分均为(2.8±0.2)分,差异无统计学意义(P>0.05)。L组和R组乳房轴位的主导管内平均密度值分别为(4 020.25±96.26)、(3 984.75±117.67)HU,侧斜位的主导管内平均密度值分别为(4 067.13±24.69)、(3 971.25±167.32)HU,侧位的主导管内平均密度值分别为(4 058.88±52.07)、(4 034.75±67.54)HU,组间比较差异无统计学意义(P>0.05)。结论乳腺导管造影中使用不同浓度(300、370 mg/m L)的非离子型碘对比剂对诊断的影响无明显差异。 展开更多
关键词 数字乳腺成像 乳腺导管造影 非离子型碘对比剂浓度
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部