期刊文献+
共找到276篇文章
< 1 2 14 >
每页显示 20 50 100
Impacted Lower Third Molar Fused with a Supernumerary Tooth—Diagnosis and Treatment Planning Using Cone-Beam Computed Tomography 被引量:11
1
作者 Osny Ferreira-Junior Luciana Dorigatti de .&.Aila +3 位作者 Marcelo Bonifacio da Silva Sampieri Eduardo Dias- Ribeiro Wei-liang Chen Song Fan 《International Journal of Oral Science》 SCIE CAS CSCD 2009年第4期224-228,共5页
This paper reported a case of fusion between an impacted third molar and a supernumerary tooth, in which a surgical intervention was carried out, with the objective of removing the dental elements. The panoramic radio... This paper reported a case of fusion between an impacted third molar and a supernumerary tooth, in which a surgical intervention was carried out, with the objective of removing the dental elements. The panoramic radiography was complemented by the Donovan's radiographic technique; but because of the proximity of the dental element to the mandibular ramus, it was not possible to have a final fusion diagnosis. Hence, the Cone-Beam Computed Tomography--which provides precise three- dimensional information--was used to determinate the fusion diagnosis and also to help in the surgical planning. In this case report we observed that the periapical, occlusal and panoramic were not able to show details which could only be examined through the cone-beam computed tomo- graphy. 展开更多
关键词 third molar supernumerary tooth oral surgery cone-beam computed tomography
下载PDF
Short-term outcomes of radiofrequency ablation for hepatocellular carcinoma using cone-beam computed tomography for planning and image guidance 被引量:5
2
作者 Xue-Song Yao Dong Yan +3 位作者 Xian-Xian Jiang Xiao Li Hui-Ying Zeng Huai Li 《World Journal of Clinical Cases》 SCIE 2021年第7期1580-1591,共12页
BACKGROUND Percutaneous radiofrequency ablation(RFA)is an effective treatment for unresectable hepatocellular carcinoma(HCC)and a minimally invasive alternative to hepatectomy for treating tumour recurrence.RFA is oft... BACKGROUND Percutaneous radiofrequency ablation(RFA)is an effective treatment for unresectable hepatocellular carcinoma(HCC)and a minimally invasive alternative to hepatectomy for treating tumour recurrence.RFA is often performed using contrast-enhanced computed tomography(CECT)and/or ultrasonography.In recent years,angiographic systems with flat panel image detectors and advanced image reconstruction algorithms have broadened the clinical applications of cone-beam computed tomography(CBCT),including RFA.Several studies have shown the effectiveness of using CBCT for immediate treatment assessments and follow-ups.AIM To assess the treatment response to RFA for HCC using CBCT.METHODS Forty-eight patients(44 men;aged 37-89 years)with solitary HCC[median size:3.2(1.2-6.6)cm]underwent RFA and were followed for 25.6(median;13.5-35.2)mo.Image fusion of CBCT and pre-operative CECT or magnetic resonance imaging(MRI)was used for tumour segmentation and needle path and ablation zone planning.Real-time image guidance was provided by overlaying the threedimensional image of the tumour and needle path on the fluoroscopy image.Treatment response was categorized as complete response(CR),partial response(PR),stable disease(SD),or progressive disease(PD).Disease progression,death,time to progression(TTP),and overall survival(OS)were recorded.Kaplan-Meier and Cox regression analyses were performed.RESULTS Initial post-RFA CECT/MRI showed 38 cases of CR(79.2%),10 of PR(20.8%),0 of SD,and 0 of PD,which strongly correlated with the planning estimation(42 CR,87.5%;6 PR,12.5%;0 SD;and 0 PD;accuracy:91.7%,P<0.01).Ten(20.8%)patients died,and disease progression occurred in 31(35.4%,median TTP:12.8 mo)patients,resulting in 12-,24-,and 35-mo OS rates of 100%,81.2%,and 72.2%,respectively,and progression-free survival(PFS)rates of 54.2%,37.1%,and 37.1%,respectively.The median dose-area product of the procedures was 79.05 Gy*cm2(range 40.95-146.24 Gy*cm2),and the median effective dose was 10.27 mSv(range 5.32-19.01 mSv).Tumour size<2 cm(P=0.008)was a significant factor for OS,while age(P=0.001),tumour size<2 cm(P<0.001),tumour stage(P=0.010),and initial treatment response(P=0.003)were significant factors for PFS.CONCLUSION Reliable RFA treatment planning and satisfactory outcomes can be achieved with CBCT. 展开更多
关键词 Hepatocellular carcinoma Radiofrequency ablation cone-beam computed tomography SURVIVAL PROGNOSIS EFFECTIVENESS
下载PDF
Performance evaluation of the simpli¯ed spherical harmonics approximation for cone-beam X-ray luminescence computed tomography imaging 被引量:1
3
作者 Haibo Zhang Guohua Geng +6 位作者 Yanrong Chen Fengjun Zhao Yuqing Hou Huangjian Yi Shunli Zhang Jingjing Yu Xiaowei He 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2017年第3期97-106,共10页
As an emerging molecular imaging modality,cone-beam X-ray luminescence computed tomog-raphy(CB-XLCT)uses X-ray-excitable probes to produce near-infrared(NIR)luminescence and then reconst ructs three-dimensional(3D)dis... As an emerging molecular imaging modality,cone-beam X-ray luminescence computed tomog-raphy(CB-XLCT)uses X-ray-excitable probes to produce near-infrared(NIR)luminescence and then reconst ructs three-dimensional(3D)distribution of the probes from surface measurements.A proper photon-transportation model is critical to accuracy of XLCT.Here,we presented a systematic comparison between the common-used Monte Carlo model and simplified spherical harmonics(SPN).The performance of the two methods was evaluated over several main spec-trums using a known XLCT material.We designed both a global measurement based on the cosine similarity and a locally-averaged relative error,to quantitatively assess these methods.The results show that the SP_(3) could reach a good balance between the modeling accuracy and computational efficiency for all of the tested emission spectrums.Besides,the SP_(1)(which is equivalent to the difusion equation(DE))can be a reasonable alternative model for emission wavelength over 692nm.In vivo experiment further demonstrates the reconstruction perfor-mance of the SP:and DE.This study would provide a valuable guidance for modeling the photon-transportation in CB-XLCT. 展开更多
关键词 cone-beam X-ray luminescence computed tomography photon-transportation model .simplified spherical harmonics approximation diffusion equations.
下载PDF
Comparison of bone alignment and fiducial marker alignment for online cone-beam computed tomography-guided radiation therapy for prostate cancer
4
作者 Hussein M.Metwally 《Oncology and Translational Medicine》 2019年第3期131-136,共6页
Objective The aim of the study was to evaluate the coverage of the prostate when prostatic implanted fiducial markers are used to verify setup of the patients in comparison to the pelvic bones while using conebeam com... Objective The aim of the study was to evaluate the coverage of the prostate when prostatic implanted fiducial markers are used to verify setup of the patients in comparison to the pelvic bones while using conebeam computed tomography(CBCT). Methods Seventeen patients with prostate cancer were included. For each patient, daily online CBCT was done. CT planning was matched with CBCT with the help of fiducial markers(3–5 markers) and another matching with done the help of pelvic bony landmarks. Registration of clinical target volume(CTV) 1 including prostate plus seminal vesicles and CTV2 including prostate only was done and were used to confirm the target volume during the process of matching. Delineation of the rectum on every CBCT was done. Two automatic margin representing planning target volume(PTV) were created. PTV1 was generated by adding 1 cm in all directions(PTV1a) and 0.7 cm in the posterior direction(PTV1b). PTV2 was generated by adding 0.5 cm in all directions(PTV2a) and 0.3 cm in the posterior direction(PTV2b). PTV1a was prescribed to receive 46 Gy in conventional fractionation with a boost dose of 30 Gy to PTV1b. The same dose was prescribed to PTV2a and PTV2b. Calculation of the percentage of intersection between CTV1and CTV2 created on CBCT with the original CTV scan was done. A comparison between the two CTVs(CTV1and CTV2) mean dose and the original delineated CTV was done. Then a comparison to the mean dose of the original CTV of PTV1a, PTV2a(CTV1a and CTV2a), and for PTV1b and PTV2b(CTV1b and CTV2b). Calculation of the mean rectal dose and also V60, V70 and V74 was done on the delineated rectum on every CBCT, and then a comparison to the planned original rectal dose. Results The created CTV1and CTV2 intersection percentage with the original CTV1and CTV2 significantly increased by 85%(range, 65%–95%, P < 0.05), when fiducial markers were used. The main difference of the received mean dose was significantly less in comparison to pelvic bone alignment(0.03% to 2% vs 0.03% to 11.6% for PTV1a, P < 0.006;0.01% to 1.8% vs 0.03% to 10.2% for PTV2a, P < 0.014;0.08 to 2.11 vs 0.04 to 11.29 for PTV1b, P < 0.015 and 0.01 to 1.79 vs 0.01 to 9.69 for PTV2b, P < 0.004). With the use of less PTV margins, significant decrease of the rectal mean dose, V60, V70 and V74 by P < 0.004, P < 0.004, P < 0.0005 and P < 0.009, respectively. Reduction of the CTV1a and CTV1b mean dose by 1.13% and 0.28% in comparison to the initial CTV1a and CTV2a.Conclusion A significant improvement of prostatic cancer patients alignment when fiducial markers are used, with more homogenous dose distribution, and with significant decrease in PTV margins. The delivered rectal dose is significantly less allowing prostate dose escalation. 展开更多
关键词 cone-beam computed tomography(cbct) PROSTATE cancer BONE ALIGNMENT fiducial marker ALIGNMENT
下载PDF
Usefulness of intra-procedural cone-beam computed tomography in modified balloon-occluded retrograde transvenous obliteration of gastric varices
5
作者 Edward Wolfgang Lee Naomi So +4 位作者 Ryan Chapman Justin P McWilliams Christopher T Loh Ronald W Busuttil Stephen T Kee 《World Journal of Radiology》 CAS 2016年第4期390-396,共7页
AIM:To evaluate whether intra-procedural conebeam computed tomography(CBCT)performed during modified balloon-occluded retrograde transvenous obliteration(mB RTO)can accurately determine technical success of complete v... AIM:To evaluate whether intra-procedural conebeam computed tomography(CBCT)performed during modified balloon-occluded retrograde transvenous obliteration(mB RTO)can accurately determine technical success of complete variceal obliteration.METHODS:From June 2012 to December 2014,15 patients who received CBCT during m BRTO for treatment of portal hypertensive gastric variceal bleeding were retrospectively evaluated.Three-dimensional(3D)CBCT images were performed and evaluated prior to the end of the procedure,and these were further analyzed and compared to the pre-procedure contrast-enhanced computed tomography to determine the technical success of m BRTO including:Complete occlusion/obliteration of:(1)gastrorenal shunt(GRS);(2)gastric varices;and(3)afferent feeding veins.Post-mB RTO contrast-enhanced CT was used to confirm the accuracy and diagnostic value of CBCT within 2-3 d.RESULTS:Intra-procedural 3D-CBCT images were 100% accurate in determining the technical success of m BRTO in all 15 cases.CBCT demonstrated complete occlusion/obliteration of GRS,gastric varices,collaterals and afferent feeding veins during m BRTO,which was confirmed with post-m BRTO CT.Two patients showed incomplete obliteration of gastric varices and feeding veins on CBCT,which therefore required additional gelfoam injections to complete the procedure.No patient required additional procedures or other interventions during their follow-up period(684 ± 279 d).CONCLUSION:CBCT during mB RTO appears to accurately and immediately determine the technical success of mB RTO.This may improve the technical and clinical success/outcome of m BRTO and reduce additional procedure time in the future. 展开更多
关键词 GASTRIC VARICES MODIFIED balloon-occluded RETROGRADE TRANSVENOUS OBLITERATION GASTRIC variceal bleeding cone-beam computed tomography Coilassisted RETROGRADE TRANSVENOUS OBLITERATION
下载PDF
Knowledge and Practices of Dentists, Oral and Maxillofacial Surgeons of Cone Beam Computed Tomography (CBCT) and the Dentascanner in a Low Income Country: Case of Togo
6
作者 Mazamaesso Tchaou Haréfétéguéna Bissa +7 位作者 Plaodesina Essobozou Pegbessou Abdoulatif Amadou Bidamin N’timon Mawuena Dansou Abdoul-Razakou Adam Lantam Sonhaye Lama-Kegdigoma Agoda-Koussema Komlan Adjenou 《Open Journal of Radiology》 2017年第1期1-8,共8页
Background: In dental-maxillofacial imaging, 3D sectional imaging progressively replaces conventional 2D imaging in developed countries. They are based specially on Computed tomography (CT-Scan), with the Dentascan ap... Background: In dental-maxillofacial imaging, 3D sectional imaging progressively replaces conventional 2D imaging in developed countries. They are based specially on Computed tomography (CT-Scan), with the Dentascan application and cone beam computed tomography (CBCT). In developing countries those technics are newly introduced. Aim: This study aimed at studying the knowledge and practices of dentist and oral and maxillofacial surgeons on sectional imaging such as Dentascan and Cone Beam Computed Tomography (CBCT). Materials and Methods: We conducted an anonymous survey among dentists and oral maxillofacial surgeons in Togo over one month. Results: The response rate was 78.79% (27/33). They were mainly male sex (sex ratio of 2.25 men for one woman). They were aged between 27 and 71 years old with an average of 49.69 years old. The majority (61.54%) had a professional experience over 20 years. The majority of respondents (65.38%) believed their level of knowledge about dental x-Ray was poor. Half of them (50%) confirmed that they had never asked for a Dentascan, and 15.38% asked from time to time for it and only two (7.69%) asked often for this test. 96.15% confirm they have no knowledge of the Dentascan. Regarding the CBCT, 84.62% didn’t ask for it because this technique did not exist in Togo before. 69.20% of respondents confessed to be interested in continuing training on sectional imaging. Conclusion: This study shows that sectional imaging is very little used by oral and dental practitioners in Togo because of the ignorance of the new techniques and the absence of the CBCT. It is therefore necessary to promote the teaching of the new technique of sectional imaging in the training syllabus of oral and dental specialists and to initiate continuing medical training. 展开更多
关键词 KNOWLEDGE Practice Dentascan Cone Beam computed tomography (cbct) DENTIST Oral and Maxillofacial Surgeon TOGO
下载PDF
A Pilot Survey of Odontomas for Size Constancy Using Cone-Beam Computed Tomography: Effect of Age, Sex, Lesion Location, and Histological Type: A Case Series
7
作者 Shinichiro Yamada Hizuru Osanai +2 位作者 Katsumitsu Shimada Hiromasa Hasegawa Keiichi Uchida 《Open Journal of Stomatology》 2021年第12期467-477,共11页
<strong>Objectives: </strong>Odontoma is the most common type of odontogenic tumors. Many studies have analyzed the statistical associations between odontoma location and patient age and sex, according to ... <strong>Objectives: </strong>Odontoma is the most common type of odontogenic tumors. Many studies have analyzed the statistical associations between odontoma location and patient age and sex, according to the histological tumor type. However, few studies have assessed odontoma morphological characteristics using cone-beam computed tomography (CBCT). We aimed to evaluate the association between odontoma location and size. <strong>Methods:</strong> We performed CBCT on patients with odontomas (19 patients;10 women, 9 men;average age, 12.6 [range, 6 - 34] years) according to the pathology type at a university hospital between April 2008 and February 2017. The locations of the lesions were noted, and their sizes were measured on CBCT images. Buccolingual, mesiodistal, and vertical diameters of the lesions were recorded on the same slice with the greatest diameters on axial, coronal, and sagittal CBCT images. <strong>Results: </strong>Altogether, 9 (47.4%) and 10 (52.6%) odontomas were located in the mandible and maxilla, respectively. There was no significant difference in the mesiodistal and vertical diameters on the CBCT image between the mandibular and maxillary groups when the odontoma size was compared with location (p < 0.05). However, the average diameters in only the buccolingual diameter were significantly greater in the maxilla. There were no significant differences between the two groups according to sex, age, or histological type. <strong>Conclusions: </strong>These data suggest that the sizes of odontomas in the maxilla are affected by bone expansion in the buccolingual direction, but they may be invariable in most settings. Three-dimensional assessment across the age groups suggests a lack of variation in size. 展开更多
关键词 cone-beam computed tomography (cbct) ODONTOMA SIZE Location
下载PDF
Dosimetric consequences of tumor volume changes after kilovoltage cone-beam computed tomography for non-operative lung cancer during adaptive intensity-modulated radiotherapy or fractionated stereotactic radiotherapy
8
作者 Jian Hu Ximing Xu +4 位作者 Guangjin Yuan Wei Ge Liming Xu Aihua Zhang Junjian Deng 《Oncology and Translational Medicine》 CAS 2015年第5期195-200,共6页
Objective The aim of this study was to investigate tumor volume changes with kilovoltage cone-beam computed tomography (kV-CBCT) and their dosimetric consequences for non-operative lung cancer during intensity-modul... Objective The aim of this study was to investigate tumor volume changes with kilovoltage cone-beam computed tomography (kV-CBCT) and their dosimetric consequences for non-operative lung cancer during intensity-modulated radiotherapy (IMRT) or fractionated stereotactic radiotherapy. Methods Eighteen patients with non-operative lung cancer who received IMRT consisting of 1.8-2.2 Gy/fraction and five fractions per week or stereotactic radiotherapy with 5-8 Gy/fraction and three fractions a week were studied, kV-CBCT was performed once per week during IMRT and at every fraction during stereotactic radiotherapy. The gross tumor volume (GTV) was contoured on the kV-CBCT images, and adaptive treatment plans were created using merged kV-CBCT and primary planning computed tomogra- phy image sets. Tumor volume changes and dosimetric parameters, including the minimum dose to 95% (D95) or 1% (D1) of the planning target volume (PTV), mean lung dose (MLD), and volume of lung tissue that received more than 5 (Vs), 10 (Vl0), 20 (V20), and 30 (V30) Gy were retrospectively analyzed. Results The average maximum change in GTV observed during IMRT or fractionated stereotactic radio- therapy was -25.85% (range, -13.09% --56.76%). The D95 and Dr of PTV for the adaptive treatment plans in all patients were not significantly different from those for the initial or former adaptive treatment plans. In patients with tumor volume changes of 〉20% in the third or fourth week of treatment during IMRT, adap- tive treatment plans offered clinically meaningful decreases in MLD and V5, V10, V20, and V30; however, in patients with tumor volume changes of 〈 20% in the third or fourth week of treatment as well as in patients with stereotactic radiotherapy, there were no significant or clinically meaningful decreases in the dosimetric parameters. Conclusion Adaptive treatment planning for decreasing tumor volume during IMRT may be beneficial for patients who experience tumor volume changes of 〉20% in the third or fourth week of treatment. 展开更多
关键词 lung cancer kilovoltage cone-beam computed tomography (kV-cbct) intensity-modulated radiotherapy (IMRT) stereotactic radiotherapy tumor changes adaptive planning
下载PDF
Alveolar Ridge Preservation Utilizing Composite (Bioceramics/Collagen) Graft: A Cone-Beam Computed Tomography Assessment in a Randomized Split-Mouth Controlled Trial
9
作者 Khalil Yosouf Omar Heshmeh Khaldoun Darwich 《Journal of Biomedical Science and Engineering》 2021年第2期64-73,共10页
Background: The vast percentage of the alveolar bone resorption process happens within the first 12 to 24 weeks post extraction;however, this phenomenon is chronic, and the alveolar ridge continues to resorb. In order... Background: The vast percentage of the alveolar bone resorption process happens within the first 12 to 24 weeks post extraction;however, this phenomenon is chronic, and the alveolar ridge continues to resorb. In order to prevent this reduction or at least recompense the loss of bone dimensions, the alveolar ridge preservation (ARP) technique was developed. Objectives: This research studied the vertical and horizontal bone dimensional changes as a result of non-molar teeth extraction alone against extraction with alveolar ridge preservation utilizing composite (bioceramics/collagen) graft by cone-beam computed tomography radiographies analyses. Material and Methods: This research was a randomized split-mouth controlled trial. 12 patients need extraction of the maxillary non-molar teeth were enrolled and allocated into 2 groups. 12 sockets after atraumatic extraction were filled with a composite graft in the role of the test group, 12 sockets left to unassisted healing after atraumatic extraction without any graft materials in the role of the control group. Two CBCT radiographs were taken at baseline and at 4 months after extraction for comparison. Both vertical and horizontal resorptions of the alveolar ridge were analyzed between test and control group by CBCT radiographs. Results: 4 months after extraction, there was a mean of vertical alveolar bone resorption compared with the baseline (0.56 ± 0.15 mm) in the test group and (1.47 ± 0.30 mm) in the control group. Whereas it was a mean of horizontal alveolar bone resorption compared with the baseline (0.90 ± 0.16 mm) in the test group and (2.26 ± 0.30 mm) in the control group. Therefore, there was a significant difference between the two groups. Conclusions: Within the limitations of this research, we demonstrated that the osteogen-plug technique significantly decreased the reduction of the bone dimensional in comparison to the tooth extraction alone, and showed that the dimensional change of the alveolar ridge after tooth extraction was minimized by using an osteogen-plug. 展开更多
关键词 Randomized Controlled Trial Composite Graft Alveolar Ridge Preservation Atraumatic Extraction cone-beam computed tomography
下载PDF
Advanced 4-dimensional cone-beam computed tomography reconstruction by combining motion estimation, motioncompensated reconstruction, biomechanical modeling and deep learning
10
作者 You Zhang Xiaokun Huang Jing Wang 《Visual Computing for Industry,Biomedicine,and Art》 2019年第1期221-235,共15页
4-Dimensional cone-beam computed tomography(4D-CBCT)offers several key advantages over conventional 3DCBCT in moving target localization/delineation,structure de-blurring,target motion tracking,treatment dose accumul... 4-Dimensional cone-beam computed tomography(4D-CBCT)offers several key advantages over conventional 3DCBCT in moving target localization/delineation,structure de-blurring,target motion tracking,treatment dose accumulation and adaptive radiation therapy.However,the use of the 4D-CBCT in current radiation therapy practices has been limited,mostly due to its sub-optimal image quality from limited angular sampling of conebeam projections.In this study,we summarized the recent developments of 4D-CBCT reconstruction techniques for image quality improvement,and introduced our developments of a new 4D-CBCT reconstruction technique which features simultaneous motion estimation and image reconstruction(SMEIR).Based on the original SMEIR scheme,biomechanical modeling-guided SMEIR(SMEIR-Bio)was introduced to further improve the reconstruction accuracy of fine details in lung 4D-CBCTs.To improve the efficiency of reconstruction,we recently developed a U-net-based deformation-vector-field(DVF)optimization technique to leverage a population-based deep learning scheme to improve the accuracy of intra-lung DVFs(SMEIR-Unet),without explicit biomechanical modeling.Details of each of the SMEIR,SMEIR-Bio and SMEIR-Unet techniques were included in this study,along with the corresponding results comparing the reconstruction accuracy in terms of CBCT images and the DVFs.We also discussed the application prospects of the SMEIR-type techniques in image-guided radiation therapy and adaptive radiation therapy,and presented potential schemes on future developments to achieve faster and more accurate 4D-CBCT imaging. 展开更多
关键词 cone-beam computed tomography Image reconstruction Motion estimation Biomechanical modeling Deep learning
下载PDF
Cone beam computed tomographic analyses of alveolar bone anatomy at the maxillary anterior region in Chinese adults 被引量:15
11
作者 Zhixuan Zhou Wu Chen +3 位作者 Ming Shen Chao Sun Jun Li Ning Chen 《The Journal of Biomedical Research》 CAS 2014年第6期498-505,共8页
To provide an anatomical basis for clinical implant esthetics,we evaluated the morphology of the nasopalatine canal(NPC) and analyzed labial and interproximal bone anatomy at the maxillary anterior region.We sought ... To provide an anatomical basis for clinical implant esthetics,we evaluated the morphology of the nasopalatine canal(NPC) and analyzed labial and interproximal bone anatomy at the maxillary anterior region.We sought to investigate the effect of maxillary protrusion and tooth labiolingual inclination on labial bone anatomy in Chinese adults.Three dimensional(3D) images were reconstructed using cone-beam computed tomography(CBCT) images from 80 Chinese subjects and by SimPlant 11.04.The dimensions of the NPC,the thickness and profile of the labial bone,the width and height of the interproximal bone,angle sella-nasion-subspinale(SNA) and angle upper central incisor-nasion,subspinale(U1-NA) were measured.The incisive foramen of the NPC was markedly wider than its nasal foramen.The dimension of its labial bone wall demonstrated an increasing width from the crestal to apical measurements.The labial bone at the maxillary anterior region was rather thin,especially at 3 mm below the cemento-enamel junction(CEJ) and the mid-root level;the profile of the labial bone was more curved at the central incisor,and the interproximal bone became wider and shorter posteriorly.There were significant relationships between maxillary protrusion and labial bone profile,tooth labiolingual inclination and labial bone thickness(P 〈 0.02).To achieve optimal esthetic outcome of implant,bone augmentation is necessary at the maxillary anterior region.For immediate or early placement at the maxillary anterior region,the implant should be located palatally to reduce labial bone resorption and marginal recession;its apex should be angulated palatally to avoid labial perforation at the apical region.To protect the NPC,implants at the central incisor region should be placed away from NPC. 展开更多
关键词 cone beam computed tomography(cbct nasopalatine canal(NPC) alveolar bone maxillary anterior region implant esthetics
下载PDF
Applied Anatomic Site Study of Palatal Anchorage Implants Using Cone Beam Computed Tomography 被引量:7
12
作者 Ren-fa Lai Hui Zou +1 位作者 Wei-dong Kong Wei Lin 《International Journal of Oral Science》 SCIE CAS CSCD 2010年第2期98-104,共7页
Aim The purpose of this study was to conduct quantitative research on bone height and bone mineral density of palatal implant sites for implantation, and to provide reference sites for safe and stable palatal implants... Aim The purpose of this study was to conduct quantitative research on bone height and bone mineral density of palatal implant sites for implantation, and to provide reference sites for safe and stable palatal implants. Methodology Three-dimensional reformatting images were reconstructed by cone beam computed tomography (CBCT) in 34 patients, aged 18 to 35 years, using EZ Implant software. Bone height was measured at 20 sites of interest on the palate. Bone mineral density was measured at the 10 sites with the highest implantation rate, classified using K-mean cluster analysis based on bone height and bone mineral density. Results According to the cluster analysis, 10 sites were classified into three clusters. Significant differences in bone height and bone mineral density were detected between these three clusters (P〈0.05). The greatest bone height was obtained in cluster 2, followed by cluster 1 and cluster 3. The highest bone mineral density was found in cluster 3, followed by cluster 1 and cluster 2. Conclusion CBCT plays an important role in pre-surgical treatment planning. CBCT is helpful in identifying safe and stable implantation sites for palatal anchorage. 展开更多
关键词 palatal implant cone-beam computed tomography bone height bone mineral density
下载PDF
Bone mineral density in cone beam computed tomography:Only a few shades of gray 被引量:3
13
作者 Marcio José da Silva Campos Thainara Salgueiro de Souza +2 位作者 Sergio Luiz Mota Júnior Marcelo Reis Fraga Robert Willer Farinazzo Vitral 《World Journal of Radiology》 CAS 2014年第8期607-612,共6页
Cone beam computed tomography(CBCT) has often been used to determine the quality of craniofacial bone structures through the determination of mineral density, which is based on gray scales of the images obtained. Howe... Cone beam computed tomography(CBCT) has often been used to determine the quality of craniofacial bone structures through the determination of mineral density, which is based on gray scales of the images obtained. However, there is no consensus regarding the accuracy of the determination of the gray scales in these exams. This study aims to provide a literature review concerning the reliability of CBCT to determine bone mineral density. The gray values obtained with CBCT show a linear relationship with the attenuation coefficients of the materials, Hounsfield Units values obtained with medical computed tomography, and density values from dual energy X-ray absorciometry. However, errors are expected when CBCT images are used to define the quality of the scanned structures be-cause these images show inconsistencies and arbitrari-ness in the gray values, particularly when related to abrupt change in the density of the object, X-ray beam hardening effect, scattered radiation, projection data discontinuity-related effect, differences between CBCTdevices, changes in the volume of the field of view(FOV), and changes in the relationships of size and position between the FOV and the object evaluated. A few methods of mathematical correction of the gray scales in CBCT have been proposed; however, they do not generate consistent values that are independent of the devices and their configurations or of the scanned objects. Thus, CBCT should not be considered the ex-amination of choice for the determination of bone and soft tissue mineral density at the current stage, par-ticularly when values obtained are to be compared to predetermined standard values. Comparisons between symmetrically positioned structures inside the FOV and in relation to the exomass of the object, as it occurs with the right and left sides of the skull, seem to be viable because the effects on the gray scale in the re-gions of interest are the same. 展开更多
关键词 tomography cone-beam computed tomography Bone mineral density REPRODUCIBILITY of results
下载PDF
基于CBCT观察上颌阻生尖牙患者蝶鞍形态变异情况
14
作者 缪世维 严沁月 +3 位作者 胡丹艳 曹丹 Izadikhah Iman 严斌 《口腔医学》 CAS 2024年第2期105-109,共5页
目的 利用锥形束CT(cone-beam computed tomography,CBCT)探讨上颌尖牙阻生与蝶鞍形态变异的相关性,从三维方向上评价蝶鞍变异对上颌尖牙阻生的临床预判。方法 收集125例上颌阻生尖牙患者(研究组)和125例与之相匹配的尖牙正常萌出者(对... 目的 利用锥形束CT(cone-beam computed tomography,CBCT)探讨上颌尖牙阻生与蝶鞍形态变异的相关性,从三维方向上评价蝶鞍变异对上颌尖牙阻生的临床预判。方法 收集125例上颌阻生尖牙患者(研究组)和125例与之相匹配的尖牙正常萌出者(对照组)。将所有样本CBCT数据导入Dolphin软件,进行重建头颅侧位片和三维图像,记录观察各组蝶鞍桥接(Ⅰ、Ⅱ、Ⅲ型)的类型分布和发生情况。使用SPSS 25.0软件对各组结果进行统计学分析。结果 研究组蝶鞍桥接的发生率显著高于对照组(P=0.004),PIC(腭侧尖牙阻生)组蝶鞍桥接的发生率显著高于对照组(P=0.007),Ⅱ型和Ⅲ型蝶鞍桥接分布和对照组存在统计学差异(P=0.012)。而BIC(唇侧尖牙阻生)组和对照组蝶鞍桥接的发生情况无统计学差异。三维重建图像上各组间蝶鞍桥接发生率无统计学差异(P>0.05)。结论 上颌尖牙阻生与蝶鞍桥接的发生情况有相关性,但仅上颌尖牙腭侧阻生患者更易发生蝶鞍桥接,而上颌尖牙唇侧阻生患者蝶鞍桥接的发生情况无变化。 展开更多
关键词 锥形束CT 上颌阻生尖牙 蝶鞍桥接
下载PDF
Ablation margin assessment of liver tumors with intravenous contrast-enhanced C-arm computed tomography 被引量:2
15
作者 Jin Iwazawa Shoichi Ohue +1 位作者 Naoko Hashimoto Takashi Mitani 《World Journal of Radiology》 CAS 2012年第3期109-114,共6页
AIM:To evaluate the feasibility of intravenous contrast-enhanced C-arm computed tomography (CT) for assessing ablative areas and margins of liver tumors. METHODS: Twelve patients (5 men, 7 women; mean age, 69.5 years)... AIM:To evaluate the feasibility of intravenous contrast-enhanced C-arm computed tomography (CT) for assessing ablative areas and margins of liver tumors. METHODS: Twelve patients (5 men, 7 women; mean age, 69.5 years) who had liver tumors (8 hepatocellular carcinomas, 4 metastatic liver tumors; mean size, 16.3 mm; size range, 8-20 mm) and who underwent percutaneous radiofrequency ablations (RFAs) with a flat-detector C-arm system were retrospectively reviewed. Intravenously enhanced C-arm CT and multidetector computed tomography (MDCT) images were obtained at the end of the RFA sessions and 3-7 d after RFA to evaluate the ablative areas and margins. The ablated areas and margins were measured using axial plane images acquired by both imaging techniques, with prior contrast-enhanced MDCT images as the reference. The sensitivity, specificity, and positive and negative predictive values of C-arm CT for detecting insufficient ablative margins (< 5 mm) were calculated. Statistical differences in the ablative areas and margins evaluated with both imaging techniques were compared using a paired t-test. RESULTS: All RFA procedures were technically successful. Of 48 total ablative margins, 19 (39.6%) and 20 (41.6%) margins were found to be insufficient with C-arm CT and MDCT, respectively. Moreover, there were no significant differences between these 2 imaging techniques in the detection of these insufficient ablative margins. The sensitivity, specificity, and positive and negative predictive values for detecting insufficient margins by C-arm CT were 90.0%, 96.4%, 94.7% and 93.1%, respectively. The mean estimated ablative areas calculated from C-arm CT (462.5 ± 202.1 mm2) and from MDCT (441.2 ± 212.5 mm2) were not significantly different. The mean ablative margins evaluated by C-arm CT (6.4 ± 2.2 mm) and by MDCT (6.0 ± 2.4 mm) were also not significantly different. CONCLUSION: The efficacy of intravenous contrast-enhanced C-arm CT in assessing the ablative areas and margins after RFA of liver tumors is nearly equivalent to that of MDCT. 展开更多
关键词 Radiofrequency ablation cone-beam computed tomography Safety margin Liver NEOPLASMS
下载PDF
基于CBCT中牙髓和牙体体积的机器学习用于青少年儿童年龄推断
16
作者 韩佳璇 沈诗慧 +3 位作者 吴怡文 孙晓丹 陈天南 陶疆 《法医学杂志》 CAS CSCD 北大核心 2024年第2期143-148,共6页
目的利用锥形束计算机体层成像(cone beam computed tomography,CBCT)影像中左上颌中切牙与左上颌尖牙的牙髓体积和牙体体积,采用逐步回归法和机器学习方法分别推断青少年儿童年龄,并对推断效果进行比较分析。方法收集498例上海市汉族... 目的利用锥形束计算机体层成像(cone beam computed tomography,CBCT)影像中左上颌中切牙与左上颌尖牙的牙髓体积和牙体体积,采用逐步回归法和机器学习方法分别推断青少年儿童年龄,并对推断效果进行比较分析。方法收集498例上海市汉族青少年儿童口腔颌面CBCT影像,测量左上颌中切牙与尖牙的牙髓体积和牙体体积并加以运算,运用K-最近邻、岭回归和决策树3种机器学习算法以及逐步回归法建立4个年龄推断模型,计算并比较决定系数、平均误差、均方根误差、均方误差和平均绝对误差等指标。绘制相关性热图,对参数间的单调关系进行可视化分析。结果K-最近邻模型(R^(2)=0.779)和岭回归模型(R^(2)=0.729)相对于逐步回归法(R^(2)=0.617)表现更为优越,而决策树模型(R^(2)=0.494)的拟合效果较差。相关性热图显示,年龄和牙髓体积、牙髓与牙体硬组织的体积比以及牙髓与牙体的体积比之间呈单调负相关。结论牙髓体积及牙髓体积占比与年龄之间存在密切关系,采用基于CBCT的机器学习方法能够提供更为准确的年龄推断结果,为进一步开展基于CBCT的深度学习牙龄推断研究奠定基础。 展开更多
关键词 法医人类学 法医齿科学 年龄推断 锥形束计算机体层成像 机器学习 青少年 儿童
下载PDF
Endodontic management of a fused left maxillary second molar and two paramolars using cone beam computed tomography: A case report 被引量:1
17
作者 Xiao-Han Mei Jin Liu +6 位作者 Wei Wang Qian-Xia Zhang Tao Hong Shi-Zhu Bai Xiao-Gang Cheng Yu Tian Wen-Kai Jiang 《World Journal of Clinical Cases》 SCIE 2022年第23期8367-8374,共8页
BACKGROUND Fused teeth usually involve several complications,such as the development of caries in the groove between fused crowns,tooth impaction,diastemas,aesthetic and periodontal problems,and pulpal pathosis,due to... BACKGROUND Fused teeth usually involve several complications,such as the development of caries in the groove between fused crowns,tooth impaction,diastemas,aesthetic and periodontal problems,and pulpal pathosis,due to the complex anatomical structure of fused teeth.A thorough diagnosis is paramount to forming an accurate treatment plan and obtaining a favourable prognosis.With the advent of cone-beam computed tomography(CBCT),accurate 3-dimensional images of teeth and their surrounding dentoalveolar structures can now be readily obtained,and the technology can accurately provide a minimally invasive approach to acquire detailed diagnostic information.Therefore,we utilize CBCT data herein to generate a digital model for the infected region in a patient,and this model enables us to better plan the management of his case.CASE SUMMARY This report details the diagnosis and endodontic treatment of a rare case involving a fused maxillary second molar and two paramolars with apical periodontitis.The patient experienced pain upon biting and cold sensitivity in the area of the maxillary left molar.No caries or other defects were identified in these teeth,and a normal response to a pulp electric viability test was observed.With the aid of CBCT and digital model technology,we initially suspected that the infection originated from the isthmus between the maxillary second molar and two paramolars.Therefore,we only treated the isthmus by an endodontic approach and did not destroy the original tooth structure;furthermore,the vital pulp was retained,and good treatment outcomes were observed at the 24-month follow-up.CONCLUSION This finding may provide new insights and perspectives on the diagnosis and treatment of fused teeth. 展开更多
关键词 cone-beam computed tomography scans Endodontic therapy Fusion of teeth Maxillary molar Digital model technology Case report
下载PDF
Clinical Endodontic Applications of Cone Beam-Computed Tomography in Modern Dental Practice 被引量:1
18
作者 Johnah C. Galicia Jeffrey Kawilarang Peter Z. Tawil 《Open Journal of Stomatology》 2017年第7期314-326,共13页
Nearly two decades since Cone Beam-Computed Tomography (CBCT) was introduced in dentistry, this technology has been proven to be a useful asset in modern dental practice. The information gleaned from a CBCT scan influ... Nearly two decades since Cone Beam-Computed Tomography (CBCT) was introduced in dentistry, this technology has been proven to be a useful asset in modern dental practice. The information gleaned from a CBCT scan influences treatment decisions and prognostication of challenging endodontic cases. The authors present six cases that utilized CBCT to diagnose vertical root fracture, to assess resorption, to guide the clinician in overcoming anatomical complexities, to hurdle diagnostic dilemmas and to perform pre-surgical evaluation. Initially, a thorough clinical assessment was performed;however, conventional periapical radiographs were not able to provide sufficient information to arrive at a definite diagnosis or a thorough treatment plan. CBCT was therefore deemed helpful for these cases. Clearly, there are advantages to using CBCT. With a better understanding of each case, the clinician can plan a definitive treatment plan and offer a clearer case prognosis to their patient. 展开更多
关键词 ENDODONTICS cone-beam computed tomography Case REPORTS RADIOGRAPHY
下载PDF
Application of Cone-beam Computed Tomography in Interventional Therapies for Liver Malignancy:A Consensus Statement by the Chinese College of Interventionalists
19
作者 Bin-Yan Zhong Zhong-Zhi Jia +5 位作者 Wen Zhang Chang Liu Shi-Hong Ying Zhi-Ping Yan Cai-Fang Ni Clinical Guidelines Committee of Chinese College of Interventionalists 《Journal of Clinical and Translational Hepatology》 SCIE 2024年第10期886-891,共6页
Despite its crucial role in interventional therapies for liver malignancy,cone-beam computed tomography(CBCT)has not yet been fully integrated into clinical practice due to several complicating factors,including nonst... Despite its crucial role in interventional therapies for liver malignancy,cone-beam computed tomography(CBCT)has not yet been fully integrated into clinical practice due to several complicating factors,including nonstandardized operations and limited recognition of CBCT among interventional radiologists.In response,the Chinese College of Interventionalists has released a consensus statement aimed at standardizing and promoting the application of CBCT in the interventional therapies for liver malignancy.This statement summarizes CBCT scanning techniques,and operational standards,and highlights its potential applications in clinical practice. 展开更多
关键词 cone-beam computed tomography Interventional radiology Liver malignancy Consensus statement CHEMOEMBOLIZATION Ablation
原文传递
Application of cone beam computed tomography in facial imaging science
20
作者 Zacharias Fourie Janalt Damstra 《上海口腔医学》 CAS CSCD 北大核心 2012年第2期220-231,共12页
Facial imaging is used to study the facial shapeand its developmental changes over time.This isimportant to diagnose acquired malformations,to studynormal and abnormal growth and to differentiatebetween the results of... Facial imaging is used to study the facial shapeand its developmental changes over time.This isimportant to diagnose acquired malformations,to studynormal and abnormal growth and to differentiatebetween the results of treatment and normal growth,and to validate facial recognition.The two mainmethods to study and record facial imaging are bymeans of cephalometry and anthropometry[1].Cephalometrics is the scientific study of themeasurements of the 展开更多
关键词 口腔医学 临床分析 患者 症状
下载PDF
上一页 1 2 14 下一页 到第
使用帮助 返回顶部