期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Constant fraction discriminator in pulsed time-of-flight laser rangefinding 被引量:4
1
作者 Ruitong ZHENG GuanhaoWU 《Frontiers of Optoelectronics》 2012年第2期182-186,共5页
Constant fraction discriminator (CFD) is one of theoretic method which can locate timing point at same fraction of echo pulse in pulsed time-of-flight (TOF) laser rangefinding. In this paper, the theory of CFD met... Constant fraction discriminator (CFD) is one of theoretic method which can locate timing point at same fraction of echo pulse in pulsed time-of-flight (TOF) laser rangefinding. In this paper, the theory of CFD method was analyzed in reality condition. The design, simulation and printed-circuit-board (PCB) performance of CFD circuit were shown. Finally, an over amplified method was introduced, by which the influence of direct-current (DC) bias error could be reduced. The experimental results showed that timing discriminator could set the timing point to a certain point on echo pulse, which did not depend on the amplitude of echo pulse. 展开更多
关键词 constant fraction discriminator (CFD) time-of-flight (TOF) pulsed TOF laser rangending direct-current(DC) bias error
原文传递
Design of a high-sampling-rate electronic module for array-detector positron annihilation lifetime measurements
2
作者 Jiale Cai Daowu Li +7 位作者 Yingjie Wang Zhiming Zhang Peilin Wang Haohui Tang Baoyi Wang Xingzhong Cao Fuyan Liu Long Wei 《Radiation Detection Technology and Methods》 CSCD 2019年第3期127-135,共9页
Introduction In this study,a high-time-resolution electronic module with a high channel density and low power consumption was designed for the measurement of the multi-detector array positron annihilation lifetimes.Th... Introduction In this study,a high-time-resolution electronic module with a high channel density and low power consumption was designed for the measurement of the multi-detector array positron annihilation lifetimes.This electronic module consisted of 32 input channels,and each channel provided a high sampling rate up to 5.12 GSPS based on a Domino Ring Sampler 4(DRS4)chip.Compared to the high-speed flash analog-digital converter(FADC),DRS4 chip has a higher channel density with an affordable lower price and power consumption.Methods The developed electronic module was also capable of real-time data analysis for directly extracting the time information of input signals at the data acquisition site,thereby significantly decreasing the data rate.The digital constant fraction discriminator(DCFD)algorithm was implemented in the field programmable gate array(FPGA)for performing the time pick-up.Results The coincidence time resolution of the electronic module was measured,and the test results revealed a value of 26 ps.A prototypical 16-pixel detector module of the multi-detector system was evaluated using this electronic module,and the coincidence time resolution of the prototypical module was 411.84 ps.Conclusions The electronic module was confirmed to satisfy the severe requirements of the multi-array-detector positron annihilation lifetime measurement system.It was also suitable for other high-time-resolution,high-channel-density,costeffective,and low-power-consumption applications. 展开更多
关键词 Digital constant fraction discriminator FPGA DRS4 Positron lifetime
原文传递
A fast digital timing and analysis system based on real-time dCFD technique for nuclear physics experiments 被引量:1
3
作者 SUN Jian LIANG Hao +1 位作者 XIE ShuXin CHENG Bin 《Science China(Technological Sciences)》 SCIE EI CAS 2012年第9期2651-2655,共5页
In this paper a fast digital real-time spectrometer was developed for timing and analysis of nuclear pulse signals. The hardware system design and algorithm implementation with field-programming gate array (FPGA) an... In this paper a fast digital real-time spectrometer was developed for timing and analysis of nuclear pulse signals. The hardware system design and algorithm implementation with field-programming gate array (FPGA) and digital signal processor (DSP) were introduced. The performance of the digital constant fraction discrimination (dCFD) platform was experimentally tested with Agilent 80 MHz function/arbitrary waveform generator and LaC13:Ce3+ scintillator detector for 22Na positron annihilation gamma spectroscopy. The amplitude and time information of "/photon was online obtained. The energy resolution could be 5.525% and the timing resolution 293.75 ps, the system error estimation of dCFD approach was also studied. The results showed that this spectrometer achieved a timing resolution close to that of traditional CFD timing resolution with a more sim- plified system structure. 展开更多
关键词 digital constant fraction discrimination real-time processing FPFA DSP experimental spectrum measurement
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部