期刊文献+
共找到33,220篇文章
< 1 2 250 >
每页显示 20 50 100
Contrast-enhanced harmonic endoscopic ultrasonography for assessment of lymph node metastases in pancreatobiliary carcinoma 被引量:9
1
作者 Takeshi Miyata Masayuki Kitano +10 位作者 Shunsuke Omoto Kumpei Kadosaka Ken Kamata Hajime Imai Hiroki Sakamoto Naoshi Nisida Yogesh Harwani Takamichi Murakami Yoshifumi Takeyama Yasutaka Chiba Masatoshi Kudo 《World Journal of Gastroenterology》 SCIE CAS 2016年第12期3381-3391,共11页
AIM: To assess the usefulness of contrast-enhanced harmonic endoscopic ultrasonography (CH-EUS) for lymph node metastasis in pancreatobiliary carcinoma.METHODS: All patients suspected of pancreatobiliary carcinoma wit... AIM: To assess the usefulness of contrast-enhanced harmonic endoscopic ultrasonography (CH-EUS) for lymph node metastasis in pancreatobiliary carcinoma.METHODS: All patients suspected of pancreatobiliary carcinoma with visible lymph nodes after standard EUS between June, 2009 and January, 2012 were enrolled. In the primary analysis, patients with successful EUS-fine needle aspiration (FNA) were included. The lymph nodes were assessed by several standard EUS variables (short and long axis lengths, shape, edge characteristic and echogenicity), color Doppler EUS variable [central intranodal blood vessel (CIV) presence] and CH-EUS variable (heterogeneous/homogeneous enhancement patterns). The diagnostic accuracy relative to EUS-FNA was calculated. In the second analysis, N-stage diagnostic accuracy of CH-EUS was compared with EUS-FNA in patients who underwent surgical resection.RESULTS: One hundred and nine patients (143 lymph nodes) fulfilled the criteria. The short axis cut-off &#x02265; 13 mm predicted malignancy with a sensitivity and specificity of 72% and 85%, respectively. These values were 72% and 63% for the long axis cut-off &#x02265; 20 mm, 62% and 75% for the round shape variable, 81% and 30% for the sharp edge variable, 66% and 61% for the hypoechogenicity variable, 70% and 72% for the CIV-absent variable, and 83% and 91% for the heterogeneous CH-EUS-enhancement variable, respectively. CH-EUS was more accurate than standard and color Doppler EUS, except the short axis cut-off. Notably, three patients excluded because of EUS-FNA failure were correctly N-staged by CH-EUS.CONCLUSION: CH-EUS complements standard and color Doppler EUS and EUS-FNA for assessment of lymph node metastases. 展开更多
关键词 contrast-enhanced harmonic endoscopic ultrasonography Sensitivity and specificity Lymph node Pancreatobiliary carcinoma Endoscopic ultrasonography-fine needle aspiration
下载PDF
Contrast-enhanced harmonic endoscopic ultrasound imaging: Basic principles, present situation and future perspectives 被引量:8
2
作者 María-Victoria Alvarez-Sánchez Bertrand Napoléon 《World Journal of Gastroenterology》 SCIE CAS 2014年第42期15549-15563,共15页
Over the last decade, the development of stabilised microbubble contrast agents and improvements in available ultrasonic equipment, such as harmonic imaging, have enabled us to display microbubble enhancements on a gr... Over the last decade, the development of stabilised microbubble contrast agents and improvements in available ultrasonic equipment, such as harmonic imaging, have enabled us to display microbubble enhancements on a greyscale with optimal contrast and spatial resolution. Recent technological advances made contrast harmonic technology available for endoscopic ultrasound(EUS) for the first time in 2008. Thus, the evaluation of microcirculation is now feasible with EUS, prompting the evolution of contrast-enhanced EUS from vascular imaging to images of the perfused tissue. Although the relevant experience is still preliminary, several reports have highlighted contrast-enhanced harmonic EUS(CHEUS) as a promising noninvasive method to visualise and characterise lesions and to differentiate benign from malignant focal lesions. Even if histology remains the gold standard, the combination of CH-EUS and EUS fine needle aspiration(EUS-FNA) can not only render EUS more accurate but may also assist physicians inmaking decisions when EUS-FNA is inconclusive,increasing the yield of EUS-FNA by guiding the puncture with simultaneous imaging of the vascularity.The development of CH-EUS has also opened up exciting possibilities in other research areas,including monitoring responses to anticancer chemotherapy or to ethanolinduced pancreatic tissue ablation,anticancer therapies based on ultrasound-triggered drug and gene delivery,and therapeutic adjuvants by contrast ultrasound-induced apoptosis.Contrast harmonic imaging is gaining popularity because of its efficacy,simplicity and noninvasive nature,and many expectations are currently resting on this technique.If its potential is confirmed in the near future,contrast harmonic imaging will become a standard practice in EUS. 展开更多
关键词 MICROBUBBLES Contrast agents contrast-enhanced harmonic endoscopic ultrasound Pancreatic tumour Gastrointestinal submucosal tumour
下载PDF
Contrast-enhanced harmonic ultrasound imaging in ablation therapy for primary hepatocellular carcinoma 被引量:7
3
作者 Yasunori Minami Masatoshi Kudo 《World Journal of Radiology》 CAS 2009年第1期86-91,共6页
The success rate of percutaneous radiofrequency(RF)ablation for hepatocellular carcinoma(HCC)depends on correct targeting via an imaging technique.However,RF electrode insertion is not completely accurate for residual... The success rate of percutaneous radiofrequency(RF)ablation for hepatocellular carcinoma(HCC)depends on correct targeting via an imaging technique.However,RF electrode insertion is not completely accurate for residual HCC nodules because B-mode ultrasound(US),color Doppler,and power Doppler US findings cannot adequately differentiate between treated and viable residual tumor tissue.Electrode insertion is also difficult when we must identify the true HCC nodule among many large regenerated nodules in cirrhotic liver.Two breakthroughs in the field of US technology,harmonic imaging and the development of second-generation contrast agents,have recently been described and have demonstrated the potential to dramatically broaden the scope of US diagnosis of hepatic lesions.Contrast-enhanced harmonic US imaging with an intravenous contrast agent can evaluate small hypervascular HCC even when B-mode US cannot adequately characterize tumor.Therefore,contrast-enhanced harmonic US can facilitate RF ablation electrode placement in hypervascular HCC,which is poorly depicted by B-mode US.The use of contrast-enhanced harmonic US in ablation therapy for liver cancer is an efficient approach. 展开更多
关键词 contrast-enhanced harmonic ultrasound HEPATOCELLULAR CARCINOMA RADIOFREQUENCY ablation Second generation MICROBUBBLES
下载PDF
Modulation of High-Order Harmonic Generation from a Monolayer ZnO by Co-rotating Two-Color Circularly Polarized Laser Fields 被引量:1
4
作者 乔月 陈家祺 +3 位作者 周书山 陈基根 蒋士成 杨玉军 《Chinese Physics Letters》 SCIE EI CAS CSCD 2024年第1期34-38,共5页
By numerically solving the two-dimensional semiconductor Bloch equation,we study the high-order harmonic emission of a monolayer ZnO under the driving of co-rotating two-color circularly polarized laser pulses.By chan... By numerically solving the two-dimensional semiconductor Bloch equation,we study the high-order harmonic emission of a monolayer ZnO under the driving of co-rotating two-color circularly polarized laser pulses.By changing the relative phase between the fundamental frequency field and the second one,it is found that the harmonic intensity in the platform region can be significantly modulated.In the higher order,the harmonic intensity can be increased by about one order of magnitude.Through time-frequency analysis,it is demonstrated that the emission trajectory of monolayer ZnO can be controlled by the relative phase,and the harmonic enhancement is caused by the second quantum trajectory with the higher emission probability.In addition,near-circularly polarized harmonics can be generated in the co-rotating two-color circularly polarized fields.With the change of the relative phase,the harmonics in the platform region can be altered from left-handed near-circularly polarization to right-handed one.Our results can obtain high-intensity harmonic radiation with an adjustable ellipticity,which provides an opportunity for syntheses of circularly polarized attosecond pulses. 展开更多
关键词 POLARIZATION ROTATING harmonic
下载PDF
Double contrast-enhanced ultrasonography improves diagnostic accuracy of T staging compared with multi-detector computed tomography in gastric cancer patients 被引量:1
5
作者 Yan-Fen Xu Hui-Yun Ma +4 位作者 Gui-Ling Huang Yu-Ting Zhang Xue-Yan Wang Ming-Jie Wei Xiao-Qing Pei 《World Journal of Gastroenterology》 SCIE CAS 2024年第23期3005-3015,共11页
BACKGROUND Gastric cancer(GC)is the most common malignant tumor and ranks third for cancer-related deaths among the worldwide.The disease poses a serious public health problem in China,ranking fifth for incidence and ... BACKGROUND Gastric cancer(GC)is the most common malignant tumor and ranks third for cancer-related deaths among the worldwide.The disease poses a serious public health problem in China,ranking fifth for incidence and third for mortality.Knowledge of the invasive depth of the tumor is vital to treatment decisions.AIM To evaluate the diagnostic performance of double contrast-enhanced ultrasonography(DCEUS)for preoperative T staging in patients with GC by comparing with multi-detector computed tomography(MDCT).METHODS This single prospective study enrolled patients with GC confirmed by preoperative gastroscopy from July 2021 to March 2023.Patients underwent DCEUS,including ultrasonography(US)and intravenous contrast-enhanced ultrasonography(CEUS),and MDCT examinations for the assessment of preoperative T staging.Features of GC were identified on DCEUS and criteria developed to evaluate T staging according to the 8th edition of AJCC cancer staging manual.The diagnostic performance of DCEUS was evaluated by comparing it with that of MDCT and surgical-pathological findings were considered as the gold standard.RESULTS A total of 229 patients with GC(80 T1,33 T2,59 T3 and 57 T4)were included.Overall accuracies were 86.9%for DCEUS and 61.1%for MDCT(P<0.001).DCEUS was superior to MDCT for T1(92.5%vs 70.0%,P<0.001),T2(72.7%vs 51.5%,P=0.041),T3(86.4%vs 45.8%,P<0.001)and T4(87.7%vs 70.2%,P=0.022)staging of GC.CONCLUSION DCEUS improved the diagnostic accuracy of preoperative T staging in patients with GC compared with MDCT,and constitutes a promising imaging modality for preoperative evaluation of GC to aid individualized treatment decision-making. 展开更多
关键词 Double contrast-enhanced ultrasonography Multi-detector computed tomography Gastric cancer T staging
下载PDF
Contrast-enhanced guided endoscopic ultrasound procedures 被引量:1
6
作者 Marcel Ioan Gheorghiu Andrada Seicean +3 位作者 Cristina Pojoga Claudia Hagiu Radu Seicean Zeno Sparchez 《World Journal of Gastroenterology》 SCIE CAS 2024年第17期2311-2320,共10页
Contrast-enhanced endoscopic ultrasound(CH-EUS)can overcome the limi-tations of endoscopic ultrasound-guided acquisition by identifying microvessels inside inhomogeneous tumours and improving the characterization of t... Contrast-enhanced endoscopic ultrasound(CH-EUS)can overcome the limi-tations of endoscopic ultrasound-guided acquisition by identifying microvessels inside inhomogeneous tumours and improving the characterization of these tumours.Despite the initial enthusiasm that oriented needle sampling under CH-EUS guidance could provide better diagnostic yield in pancreatic solid lesions,further studies did not confirm the supplementary values in cases of tissue acquisition guided by CH-EUS.This review details the knowledge based on the available data on contrast-guided procedures.The indications for CH-EUS tissue acquisition include isoechoic EUS lesions with poor visible delineation where CH-EUS can differentiate the lesion vascularisation from the surrounding parenchyma and also the mural nodules within biliopancreatic cystic lesions,which occur in select cases.Additionally,the roles of CH-EUS-guided therapy in patients whose pancreatic fluid collections or bile ducts that have an echogenic content have indications for drainage,and patients who have nonvisualized vessels that need to be highlighted via Doppler EUS are presented.Another indication is represented if there is a need for an immediate assessment of the post-radiofrequency ablation of pancreatic neuroendocrine tumours,in which case CH-EUS can be used to reveal the incomplete tumour destruction. 展开更多
关键词 ENDOSONOGRAPHY contrast-enhanced endoscopic ultrasound Tissue acquisition Fine needle aspiration Fine needle biopsy Drainage Pancreatic fluid collections BIOPSY PANCREAS
下载PDF
Harmonics in the Squirrel Cage Induction Motor Analytic Calculation Part III: Influence on the Torque-speed Characteristic 被引量:1
7
作者 G.Kovács 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第1期86-102,共17页
The harmonics that appear in the squirrel cage asynchronous machine have been discussed in great detail in the literature for a long time. However, the systematization of the phenomenon is still pending, so we made an... The harmonics that appear in the squirrel cage asynchronous machine have been discussed in great detail in the literature for a long time. However, the systematization of the phenomenon is still pending, so we made an attempt to fill this gap in the previous parts of our study by elaborating formulas for calculation of parasitic torques. It was a general demand among those who work in this field towards the author to verify his formulas with measurements. In the literature, it seems,only one detailed, purposeful series of measurements has been published so far, the purpose of which was to investigate the effect of the number of rotor slots on the torque-speed characteristic curve of the machine. The main goal of this study is to verify the correctness of the formulas by comparing them with the referred series of measurements. Relying on this, the expected synchronous parasitic torques were developed for the frequently used rotor slot numbers-as a design guide for the engineer.Thus, together with our complete table for radial magnetic pull published in our previous work, the designer has all the principles, data and formulas available for the right number of rotor slots for his given machine and for the drive system. This brings this series of papers to an end. 展开更多
关键词 Asynchronous parasitic torques Induction motor Squirrel cage rotor Space harmonics Synchronous parasitic torques
下载PDF
Survival Analysis of Patients Undergoing Intraoperative Contrast-enhanced Ultrasound in the Surgical Treatment of Malignant Glioma
8
作者 Xu CHEN Ya-ni PENG +3 位作者 Fang-ling CHENG Dan CAO An-yu TAO Jian CHEN 《Current Medical Science》 SCIE CAS 2024年第2期399-405,共7页
Objective:Complete resection of malignant gliomas is often challenging.Our previous study indicated that intraoperative contrast-enhanced ultrasound(ICEUS)could aid in the detection of residual tumor remnants and the ... Objective:Complete resection of malignant gliomas is often challenging.Our previous study indicated that intraoperative contrast-enhanced ultrasound(ICEUS)could aid in the detection of residual tumor remnants and the total removal of brain lesions.This study aimed to investigate the survival rates of patients undergoing resection with or without the use of ICEUS and to assess the impact of ICEUS on the prognosis of patients with malignant glioma.Methods:A total of 64 patients diagnosed with malignant glioma(WHO grade HI and IV)who underwent surgery between 2012 and 2018 were included.Among them,29 patients received ICEUS.The effects of ICEUS on overall survival(OS)and progression-free survival(PFS)of patients were evaluated.A quantitative analysis was performed to compare ICEUS parameters between gliomas and the surrounding tissues.Results:The ICEUS group showed better survival rates both in OS and PFS than the control group.The univariate analysis revealed that age,pathology and ICEUS were significant prognostic factors for PFS,with only age being a significant prognostic factor for OS.In multivariate analysis,age and ICEUS were significant prognostic factors for both OS and PFS.The quantitative analysis showed that the intensity and transit time of microbubbles reaching the tumors were significantly different from those of microbubbles reaching the surrounding tissue.Conclusion:ICEUS facilitates the identification of residual tumors.Age and ICEUS are prognostic factors for malignant glioma surgery,and use of ICEUS offers a better prognosis for patients with malignant glioma. 展开更多
关键词 intraoperative contrast-enhanced ultrasound malignant glioma extent of resection SURVIVAL PROGNOSIS
下载PDF
Bunching enhancement for coherent harmonic generation by using phase merging effects
9
作者 Ke Feng Kangnan Jiang +3 位作者 Runshu Hu Shixia Luan Wentao Wang Ruxin Li 《Matter and Radiation at Extremes》 SCIE EI CSCD 2024年第5期10-21,共12页
In this paper,promising but simple schemes are investigated to enhance the micro-bunching of relativistic electron beams for coherent harmonic generation(CHG)by using phase merging effects.In contrast to the standard ... In this paper,promising but simple schemes are investigated to enhance the micro-bunching of relativistic electron beams for coherent harmonic generation(CHG)by using phase merging effects.In contrast to the standard CHG scheme,two specially designed dispersion sections(DSs)are adopted with the DS-modulator–DS configuration.The phase space of the e beam is appropriately coupled in the first DS,and the electrons within one seed wavelength can merge to the same phase with a matched second DS.Micro-bunching of the e beam can thus be enhanced by a large margin with much higher-harmonic components.Taking e beams from laser wakefield accelerators(LWFAs)as an example,start-to-end simulations are performed to show the effectiveness and robustness of the proposed schemes with several configurations.The beam current can be optimized to several tens to hundreds of kiloamperes,and the radiation power reaches hundreds of megawatts in the extreme ultraviolet regime within a 3.5 m-long beamline.The proposed schemes offer new opportunities for future compact free-electron lasers driven by LWFAs and provides prospects for truly compact and widely applicable systems. 展开更多
关键词 MODULATOR harmonic PHASE
下载PDF
High-order harmonic generation of ZnO crystals in chirped and static electric fields
10
作者 张玲玉 何永林 +5 位作者 谢卓璇 高芳艳 徐清芸 葛鑫磊 罗香怡 郭静 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第1期335-343,共9页
High harmonic generation in ZnO crystals under chirped single-color field and static electric field are investigated by solving the semiconductor Bloch equation(SBE). It is found that when the chirp pulse is introduce... High harmonic generation in ZnO crystals under chirped single-color field and static electric field are investigated by solving the semiconductor Bloch equation(SBE). It is found that when the chirp pulse is introduced, the interference structure becomes obvious while the harmonic cutoff is not extended. Furthermore, the harmonic efficiency is improved when the static electric field is included. These phenomena are demonstrated by the classical recollision model in real space affected by the waveform of laser field and inversion symmetry. Specifically, the electron motion in k-space shows that the change of waveform and the destruction of the symmetry of the laser field lead to the incomplete X-structure of the crystal-momentum-resolved(k-resolved) inter-band harmonic spectrum. Furthermore, a pre-acceleration process in the solid four-step model is confirmed. 展开更多
关键词 high-order harmonic generation the semiconductor Bloch equation k-resolved inter-band harmonic spectrum four-step semiclassical model
下载PDF
Evaluating microvascular invasion in hepatitis B virus-related hepatocellular carcinoma based on contrast-enhanced computed tomography radiomics and clinicoradiological factors
11
作者 Zi-Ling Xu Gui-Xiang Qian +6 位作者 Yong-Hai Li Jian-Lin Lu Ming-Tong Wei Xiang-Yi Bu Yong-Sheng Ge Yuan Cheng Wei-Dong Jia 《World Journal of Gastroenterology》 SCIE CAS 2024年第45期4801-4816,共16页
BACKGROUND Microvascular invasion(MVI)is a significant indicator of the aggressive behavior of hepatocellular carcinoma(HCC).Expanding the surgical resection margin and performing anatomical liver resection may improv... BACKGROUND Microvascular invasion(MVI)is a significant indicator of the aggressive behavior of hepatocellular carcinoma(HCC).Expanding the surgical resection margin and performing anatomical liver resection may improve outcomes in patients with MVI.However,no reliable preoperative method currently exists to predict MVI status or to identify patients at high-risk group(M2).AIM To develop and validate models based on contrast-enhanced computed tomo-graphy(CECT)radiomics and clinicoradiological factors to predict MVI and identify M2 among patients with hepatitis B virus-related HCC(HBV-HCC).The ultimate goal of the study was to guide surgical decision-making.METHODS A total of 270 patients who underwent surgical resection were retrospectively analyzed.The cohort was divided into a training dataset(189 patients)and a validation dataset(81)with a 7:3 ratio.Radiomics features were selected using intra-class correlation coefficient analysis,Pearson or Spearman’s correlation analysis,and the least absolute shrinkage and selection operator algorithm,leading to the construction of radscores from CECT images.Univariate and multivariate analyses identified significant clinicoradiological factors and radscores associated with MVI and M2,which were subsequently incorporated into predictive models.The models’performance was evaluated using calibration,discrimination,and clinical utility analysis.RESULTS Independent risk factors for MVI included non-smooth tumor margins,absence of a peritumoral hypointensity ring,and a high radscore based on delayed-phase CECT images.The MVI prediction model incorporating these factors achieved an area under the curve(AUC)of 0.841 in the training dataset and 0.768 in the validation dataset.The M2 prediction model,which integrated the radscore from the 5 mm peritumoral area in the CECT arterial phase,α-fetoprotein level,enhancing capsule,and aspartate aminotransferase level achieved an AUC of 0.865 in the training dataset and 0.798 in the validation dataset.Calibration and decision curve analyses confirmed the models’good fit and clinical utility.CONCLUSION Multivariable models were constructed by combining clinicoradiological risk factors and radscores to preoper-atively predict MVI and identify M2 among patients with HBV-HCC.Further studies are needed to evaluate the practical application of these models in clinical settings. 展开更多
关键词 Radiomics contrast-enhanced computed tomography Hepatocellular carcinoma Microvascular invasion Hepatitis B virus
下载PDF
Tunable spectral continuous shift of high-order harmonic generation in atoms by a plasmon-assisted shaping pulse
12
作者 王源 李玉龙 +7 位作者 乔月 高娜 郭福明 陈洲 赫兰海 杨玉军 赵曦 王俊 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期433-440,共8页
We delve into the phenomenon of high-order harmonic generation within a helium atom under the influence of a plasmon-assisted shaping pulse.Our findings reveal an intriguing manipulation of the frequency peak position... We delve into the phenomenon of high-order harmonic generation within a helium atom under the influence of a plasmon-assisted shaping pulse.Our findings reveal an intriguing manipulation of the frequency peak position in the harmonic emission by adjusting the absolute phase parameter within the frequency domain of the shaping pulse.This phenomenon holds potential significance for experimental setups necessitating precisely tuned single harmonics.Notably,we observe a modulated shift in the created harmonic photon energy,spanning an impressive range of 1.2 eV.This frequency peak shift is rooted in the asymmetry exhibited by the rising and falling edges of the laser pulse,directly influencing the position of the peak frequency emission.Our study quantifies the dependence of this tuning range and the asymmetry of the laser pulse,offering valuable insights into the underlying mechanisms driving this phenomenon.Furthermore,our investigation uncovers the emergence of semi-integer order harmonics as the phase parameter is altered.We attribute this discovery to the intricate interference between harmonics generated by the primary and secondary return cores.This observation introduces an innovative approach for generating semi-integer order harmonics,thus expanding our understanding of high-order harmonic generation.Ultimately,our work contributes to the broader comprehension of complex phenomena in laser-matter interactions and provides a foundation for harnessing these effects in various applications,particularly those involving precise spectral control and the generation of unique harmonic patterns. 展开更多
关键词 high-order harmonic semi-integer-order spectra shift inhomogeneous field
下载PDF
Gastrointestinal contrast-enhanced ultrasonography for diagnosis and treatment of peptic ulcer in children
13
作者 Yu-Hua Zhang Zhi-Hua Xu +1 位作者 Shuang-Shuang Ni Hong-Xia Luo 《World Journal of Gastroenterology》 SCIE CAS 2024年第7期705-713,共9页
BACKGROUND The detection rate of peptic ulcer in children is improving,with development of diagnostic procedures.Gastroscopy is the gold standard for the diagnosis of peptic ulcer,but it is an invasive procedure.Gastr... BACKGROUND The detection rate of peptic ulcer in children is improving,with development of diagnostic procedures.Gastroscopy is the gold standard for the diagnosis of peptic ulcer,but it is an invasive procedure.Gastrointestinal contrast-enhanced ultrasonography(CEUS)has the advantages of being painless,noninvasive,nonradioactive,easy to use,and safe.AIM To investigate the clinical value of CEUS for diagnosis and treatment of peptic ulcer in children.METHODS We investigated 43 children with digestive tract symptoms in our hospital from January 2021 to June 2022.All children were examined by routine ultrasound,gastrointestinal CEUS,and gastroscopy.The pathological results of gastroscopy were taken as the gold standard.Routine ultrasonography was performed before gastrointestinal CEUS.Conventional ultrasound showed the thickness of the gastroduodenal wall,gastric peristalsis,and the adjacent organs and tissues around the abdominal cavity.Gastrointestinal CEUS recorded the thickness of the gastroduodenal wall;the size,location and shape of the ulcer;gastric peristalsis;and adjacent organs and tissues around the abdominal cavity.The results of routine ultrasound and gastrointestinal ultrasound were compared with those of gastroscopy to evaluate the diagnostic results and coincidence rate of routine ultrasound and gastrointestinal CEUS.All children received informed consent from their guardians for CEUS.This study was reviewed and approved by the hospital medical ethics committee.RESULTS Among the 43 children,17(15 male,2 female)were diagnosed with peptic ulcer by gastroscopy.There were 26 children with nonpeptic ulcer.There were eight cases of peptic ulcer and 35 of nonpeptic ulcer diagnosed by conventional ultrasound.The diagnostic coincidence rate of peptic ulcer in children diagnosed by conventional ultrasound was 79.1%(34/43),which was significantly different from that of gastroscopy(P=0.033).It indicates that the coincidence rate of gastrointestinal contrast-enhanced ultrasound and gastroscope is low.Fifteen cases of peptic ulcer and 28 of nonpeptic ulcer were diagnosed by CEUS.The diagnostic coincidence rate of peptic ulcer in children was 95.3%(41/43).There was no significant difference between CEUS and gastroscopy(P=0.655).It indicates that the coincidence rate of gastrointestinal contrast-enhanced ultrasound and gastroscope is high.CONCLUSION Gastrointestinal CEUS has a high coincidence rate in the diagnosis of peptic ulcer in children,and can be used as a preliminary examination method. 展开更多
关键词 contrast-enhanced ultrasound Peptic ulcer CHILDREN Gastrointestinal tract Abdominal pain Acoustic contrast agent
下载PDF
Correlation of dynamic contrast-enhanced ultrasonography and the Ki-67 labelling index in pancreatic ductal adenocarcinoma
14
作者 Xiao-Jing Lin Shu Zhu +4 位作者 Dan Wang Jing-Yuan Chen Su-Xian Wei Shi-Yun Chen Hong-Chang Luo 《World Journal of Gastroenterology》 SCIE CAS 2024年第44期4697-4708,共12页
BACKGROUND Pancreatic ductal adenocarcinoma(PDAC)is a highly malignant and aggressive tumor,and high Ki-67 expression indicates poor histological differentiation and prognosis.Therefore,one of the challenges in diagno... BACKGROUND Pancreatic ductal adenocarcinoma(PDAC)is a highly malignant and aggressive tumor,and high Ki-67 expression indicates poor histological differentiation and prognosis.Therefore,one of the challenges in diagnosing preoperatively patients with PDAC is predicting the degree of malignancy.Dynamic contrast-enhanced ultrasonography(DCE-US)plays a crucial role in abdominal tumor diagnosis,and can adequately show the microvascular composition within the tumors.However,the relationship between DCE-US and the Ki-67 labelling index remains unclear at the present time.AIM To predict the correlation between Ki-67 expression and the parameters of DCEUS.METHODS Patients with PDAC who underwent DCE-US were retrospectively analyzed.Patients who had received any treatment(radiotherapy or chemotherapy)prior to DCE-US;had incomplete clinical,imaging,or pathologic information;and had poor-quality image analysis were excluded.Correlations between Ki-67 expression and the parameters of DCE-US in patients with PDAC were assessed using Spearman’s rank correlation analysis.The diagnostic performances of these parameters in high Ki-67 expression group were evaluated according to receiver operating characteristic curve.RESULTS Based on the Ki-67 labelling index,30 patients were divided into two groups,i.e.,the high expression group and the low expression group.Among the relative quantitative parameters between the two groups,relative half-decrease time(rHDT),relative peak enhancement,relative wash-in perfusion index and relative wash-in rate were significantly different between two groups(P=0.018,P=0.025,P=0.028,P=0.035,respectively).The DCE-US parameter rHDT was moderately correlated with Ki-67 expression,and rHDT≥1.07 was more helpful in accurately diagnosing high Ki-67 expression,exhibiting a sensitivity and specificity of 53.8%and 94.1%,respectively.CONCLUSION One parameter of DCE-US,rHDT,correlates with high Ki-67 expression.It demonstrates that parameters obtained noninvasively by DCE-US could better predict Ki-67 expression in PDAC preoperatively. 展开更多
关键词 Pancreatic ductal adenocarcinoma Dynamic contrast-enhanced ultrasonography Ki-67 antigen Quantitative analysis Prognostic situation
下载PDF
Clinical value of oral contrast-enhanced ultrasonography in diagnosis of gastric tumors
15
作者 Chuan-Yu Wang Xiao-Jing Fan +6 位作者 Fei-Liang Wang Yue-Yue Ge Zhao Cai Wei Wang Xin-Ping Zhou Jun Du De-Wei Dai 《World Journal of Gastrointestinal Oncology》 SCIE 2024年第1期110-117,共8页
BACKGROUND The incidence of gastric cancer remains high,and it is the sixth most common cancer and the fourth leading cause of cancer deaths worldwide.Oral contrastenhanced ultrasonography is a simple,non-invasive,and... BACKGROUND The incidence of gastric cancer remains high,and it is the sixth most common cancer and the fourth leading cause of cancer deaths worldwide.Oral contrastenhanced ultrasonography is a simple,non-invasive,and painless method for the diagnosis of gastric tumors.AIM To explore the diagnostic value of oral contrast-enhanced ultrasonography for the detection of gastric tumors.METHODS The screening results based on oral contrast-enhanced ultrasonography and electronic gastroscopy were compared with those of the postoperative pathological examination.RESULTS Among 42 patients with gastric tumors enrolled in the study,the diagnostic accordance rate was 95.2%for oral contrast-enhanced ultrasonography(n=40)and 90.5%for electronic gastroscopy(n=38)compared with postoperative pathological examination.The Kappa value of consistency test with pathological findings was 0.812 for oral contrast-enhanced ultrasonography and 0.718 for electronic gastroscopy,and there was no significant difference between them(P=0.397).For the TNM staging of gastric tumors,the accuracy rate of oral contrast enhanced ultrasonography was 81.9%for the overall T staging and 50%,77.8%,100%,and 100%for T1,T2,T3,and T4 staging,respectively.The sensitivity and specificity were both 100%for stages T3 and T4.The diagnostic accuracy rate of oral contrast-enhanced ultrasonography was 93.8%,80%,100%,and 100%for stages N0,N1-N3,M0,and M1,respectively.CONCLUSION The accordance rate of qualitative diagnosis by oral contrast-enhanced ultrasonography is comparable to that of gastroscopy,and it could be used as the preferred method for the early screening of gastric tumors. 展开更多
关键词 Oral contrast-enhanced ultrasonography Gastric tumor Electronic gastroscopy Controlled study Pathological examination DIAGNOSIS
下载PDF
Abnormal transition of the electron energy distribution with excitation of the second harmonic in low-pressure radio-frequency capacitively coupled plasmas
16
作者 余乐怡 陆文琪 张丽娜 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第8期58-63,共6页
The self-excited second harmonic in radio-frequency capacitively coupled plasma was significantly enhanced by adjusting the external variable capacitor.At a lower pressure of 3 Pa,the excitation of the second harmonic... The self-excited second harmonic in radio-frequency capacitively coupled plasma was significantly enhanced by adjusting the external variable capacitor.At a lower pressure of 3 Pa,the excitation of the second harmonic caused an abnormal transition of the electron energy probability function,resulting in abrupt changes in the electron density and temperature.Such changes in the electron energy probability function as well as the electron density and temperature were not observed at the higher pressure of 16 Pa under similar harmonic changes.The phenomena are related to the influence of the second harmonic on stochastic heating,which is determined by both amplitude and the relative phase of the harmonics.The results suggest that the self-excited high-order harmonics must be considered in practical applications of lowpressure radio-frequency capacitively coupled plasmas. 展开更多
关键词 RADIO-FREQUENCY capacitively coupled plasma harmonicS the electron energy probability function
下载PDF
Clinical application of oral contrast-enhanced ultrasound in evaluating the preoperative T staging of gastric cancer
17
作者 Yu Liang Wan-Yi Jing +6 位作者 Jun Song Qiu-Xin Wei Zhi-Qing Cai Juan Li Ping Wu Dong Wang Yi Ma 《World Journal of Gastroenterology》 SCIE CAS 2024年第41期4439-4448,共10页
BACKGROUND Oral contrast-enhanced ultrasound(OCEUS)is widely used in the noninvasive diagnosis and screening of gastric cancer(GC)in China.AIM To investigate the clinical application of OCEUS in evaluating the preoper... BACKGROUND Oral contrast-enhanced ultrasound(OCEUS)is widely used in the noninvasive diagnosis and screening of gastric cancer(GC)in China.AIM To investigate the clinical application of OCEUS in evaluating the preoperative T staging of gastric cancer.METHODS OCEUS was performed before the operation,and standard ultrasound images were retained.The depth of infiltration of GC(T-stage)was evaluated according to the American Joint Committee on Cancer 8th edition of the tumor-nodemetastasis staging criteria.Finally,with postoperative pathological staging as the gold standard reference,the sensitivity,specificity,negative predictive value,positive predictive value,and diagnostic value of OCEUS T staging were evaluated.RESULTS OCEUS achieved diagnostic accuracy rates of 76.6%(T1a),69.6%(T1b),62.7%(T2),60.8%(T3),88.0%(T4a),and 88.7%(T4b),with an average of 75.5%.Ultrasonic T staging sensitivity exceeded 62%,aside from T1b at 40.3%,while specificity was over 91%,except for T3 with 83.5%.The Youden index was above 60%,with T1b and T2 being exceptions.OCEUS T staging corresponded closely with pathology in T4b(kappa>0.75)and moderately in T1a,T1b,T2,T3,and T4a(kappa 0.40-0.75),registering a concordance rate exceeding 84%.CONCLUSION OCEUS was effective,reliable,and accurate in diagnosing the preoperative T staging of GC.As a noninvasive diagnostic technique,OCEUS merits clinical popularization. 展开更多
关键词 Gastric cancer Oral contrast-enhanced ultrasound Tumor-node-metastasis staging Noninvasive diagnosis and screening Clinical value
下载PDF
Terahertz quasi-perfect vortex beam with integer-order and fractional-order generated by spiral spherical harmonic axicon
18
作者 涂思语 刘德峰 +2 位作者 刘劲松 杨振刚 王可嘉 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第1期458-467,共10页
We propose a new method to generate terahertz perfect vortex beam with integer-order and fractional-order. A new optical diffractive element composed of the phase combination of a spherical harmonic axicon and a spira... We propose a new method to generate terahertz perfect vortex beam with integer-order and fractional-order. A new optical diffractive element composed of the phase combination of a spherical harmonic axicon and a spiral phase plate is designed and called spiral spherical harmonic axicon. A terahertz Gaussian beam passes through the spiral spherical harmonic axicon to generate a terahertz vortex beam. When only the topological charge number carried by spiral spherical harmonic axicon increases, the ring radius of terahertz vortex beam increases slightly, so the beam is shaped into a terahertz quasi-perfect vortex beam. Importantly, the terahertz quasi-perfect vortex beam can carry not only integer-order topological charge number but also fractional-order topological charge number. This is the first time that vortex beam and quasi-perfect vortex beam with fractional-order have been successfully realized in terahertz domain and experiment. 展开更多
关键词 TERAHERTZ spiral spherical harmonic axicon quasi-perfect vortex beam topological charge number
下载PDF
Evaluating the efficacy of percutaneous puncture biopsy guided by contrast-enhanced ultrasound for peripheral pulmonary lesions
19
作者 Xiao Jiang Jun Chen +8 位作者 Fang-Fang Gu Zhong-Rong Li Yu-Shan Song Jing-Jing Long Shu-Zhen Zhang Ting-Ting Xu Yong-Jun Tang Ji-Ying Gu Xiang-Ming Fang 《World Journal of Clinical Cases》 SCIE 2024年第19期3791-3799,共9页
BACKGROUND The incidence and mortality of lung cancer have increased annually.Accurate diagnosis can help improve therapeutic efficacy of interventions and prognosis.Percutaneous lung biopsy is a reliable method for t... BACKGROUND The incidence and mortality of lung cancer have increased annually.Accurate diagnosis can help improve therapeutic efficacy of interventions and prognosis.Percutaneous lung biopsy is a reliable method for the clinical diagnosis of lung cancer.Ultrasound-guided percutaneous lung biopsy technology has been widely promoted and applied in recent years.AIM To investigate the diagnostic value of contrast-enhanced ultrasound(CEUS)-guided percutaneous biopsy in peripheral pulmonary lesions.METHODS We retrospectively collected data on 237 patients with peripheral thoracic focal lesions who underwent puncture biopsy at Wuxi People’s Hospital.The patients were randomly divided into two groups:The CEUS-guided before lesion puncture group(contrast group)and conventional ultrasound-guided group(control group).Analyze the diagnostic efficacy of the puncture biopsy,impact of tumor size,and number of puncture needles and complications were analyzed and compared between the two groups.RESULTS Accurate pathological results were obtained for 92.83%(220/237)of peripheral lung lesions during the first biopsy,with an accuracy rate of 95.8%(113/118)in the contrast group and 89.9%(107/119)in the control group.The difference in the area under the curve(AUC)between the contrast and the control groups was not statistically significant(0.952 vs 0.902,respectively;P>0.05).However,when the lesion diameter≥5 cm,the diagnostic AUC of the contrast group was higher than that of the control group(0.952 vs 0.902,respectively;P<0.05).In addition,the average number of puncture needles in the contrast group was lower than that in the control group(2.58±0.53 vs 2.90±0.56,respectively;P<0.05).CONCLUSION CEUS guidance can enhance the efficiency of puncture biopsy of peripheral pulmonary lesions,especially for lesions with a diameter≥5 cm.Therefore,CEUS guidance has high clinical diagnostic value in puncture biopsy of peripheral focal lung lesions. 展开更多
关键词 contrast-enhanced ultrasound Peripheral lung lesions Ultrasound guidance BIOPSY Peripheral thoracic focal lesions
下载PDF
THE GRADIENT ESTIMATE OF SUBELLIPTIC HARMONIC MAPS WITH A POTENTIAL
20
作者 Han LUO 《Acta Mathematica Scientia》 SCIE CSCD 2024年第4期1189-1199,共11页
In this paper,we investigate subelliptic harmonic maps with a potential from noncompact complete sub-Riemannian manifolds corresponding to totally geodesic Riemannian foliations.Under some suitable conditions,we give ... In this paper,we investigate subelliptic harmonic maps with a potential from noncompact complete sub-Riemannian manifolds corresponding to totally geodesic Riemannian foliations.Under some suitable conditions,we give the gradient estimates of these maps and establish a Liouville type result. 展开更多
关键词 sub-Riemannian manifolds subelliptic harmonic maps with potential gradient estimate Liouville Theorem
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部