期刊文献+
共找到32,713篇文章
< 1 2 250 >
每页显示 20 50 100
Contrast-enhanced harmonic endoscopic ultrasonography for assessment of lymph node metastases in pancreatobiliary carcinoma 被引量:8
1
作者 Takeshi Miyata Masayuki Kitano +10 位作者 Shunsuke Omoto Kumpei Kadosaka Ken Kamata Hajime Imai Hiroki Sakamoto Naoshi Nisida Yogesh Harwani Takamichi Murakami Yoshifumi Takeyama Yasutaka Chiba Masatoshi Kudo 《World Journal of Gastroenterology》 SCIE CAS 2016年第12期3381-3391,共11页
AIM: To assess the usefulness of contrast-enhanced harmonic endoscopic ultrasonography(CH-EUS) for lymph node metastasis in pancreatobiliary carcinoma.METHODS: All patients suspected of pancreatobiliary carcinoma with... AIM: To assess the usefulness of contrast-enhanced harmonic endoscopic ultrasonography(CH-EUS) for lymph node metastasis in pancreatobiliary carcinoma.METHODS: All patients suspected of pancreatobiliary carcinoma with visible lymph nodes after standard EUS between June, 2009 and January, 2012 were enrolled.In the primary analysis, patients with successful EUSfine needle aspiration(FNA) were included. The lymph nodes were assessed by several standard EUS variables(short and long axis lengths, shape, edge characteristic and echogenicity), color Doppler EUS variable [central intranodal blood vessel(CIV) presence] and CH-EUS variable(heterogeneous/homogeneous enhancement patterns). The diagnostic accuracy relative to EUSFNA was calculated. In the second analysis, N-stage diagnostic accuracy of CH-EUS was compared with EUS-FNA in patients who underwent surgical resection.RESULTS: One hundred and nine patients(143 lymph nodes) fulfilled the criteria. The short axis cutoff ≥ 13 mm predicted malignancy with a sensitivity and specificity of 72% and 85%, respectively. These values were 72% and 63% for the long axis cut-off ≥ 20 mm, 62% and 75% for the round shape variable, 81% and 30% for the sharp edge variable, 66% and 61% for the hypoechogenicity variable, 70% and 72% for the CIV-absent variable, and 83% and 91% for the heterogeneous CH-EUS-enhancement variable, respectively. CH-EUS was more accurate than standard and color Doppler EUS, except the short axis cut-off. Notably, three patients excluded because of EUS-FNA failure were correctly N-staged by CH-EUS.CONCLUSION: CH-EUS complements standard and color Doppler EUS and EUS-FNA for assessment of lymph node metastases. 展开更多
关键词 contrast-enhanced harmonic endoscopic ULTRASONOGRAPHY Sensitivity and SPECIFICITY LYMPH node Pancrea
下载PDF
Contrast-enhanced harmonic ultrasound imaging in ablation therapy for primary hepatocellular carcinoma 被引量:7
2
作者 Yasunori Minami Masatoshi Kudo 《World Journal of Radiology》 CAS 2009年第1期86-91,共6页
The success rate of percutaneous radiofrequency(RF)ablation for hepatocellular carcinoma(HCC)depends on correct targeting via an imaging technique.However,RF electrode insertion is not completely accurate for residual... The success rate of percutaneous radiofrequency(RF)ablation for hepatocellular carcinoma(HCC)depends on correct targeting via an imaging technique.However,RF electrode insertion is not completely accurate for residual HCC nodules because B-mode ultrasound(US),color Doppler,and power Doppler US findings cannot adequately differentiate between treated and viable residual tumor tissue.Electrode insertion is also difficult when we must identify the true HCC nodule among many large regenerated nodules in cirrhotic liver.Two breakthroughs in the field of US technology,harmonic imaging and the development of second-generation contrast agents,have recently been described and have demonstrated the potential to dramatically broaden the scope of US diagnosis of hepatic lesions.Contrast-enhanced harmonic US imaging with an intravenous contrast agent can evaluate small hypervascular HCC even when B-mode US cannot adequately characterize tumor.Therefore,contrast-enhanced harmonic US can facilitate RF ablation electrode placement in hypervascular HCC,which is poorly depicted by B-mode US.The use of contrast-enhanced harmonic US in ablation therapy for liver cancer is an efficient approach. 展开更多
关键词 contrast-enhanced harmonic ultrasound HEPATOCELLULAR CARCINOMA RADIOFREQUENCY ablation Second generation MICROBUBBLES
下载PDF
Contrast-enhanced harmonic endoscopic ultrasound imaging: Basic principles, present situation and future perspectives 被引量:8
3
作者 María-Victoria Alvarez-Sánchez Bertrand Napoléon 《World Journal of Gastroenterology》 SCIE CAS 2014年第42期15549-15563,共15页
Over the last decade, the development of stabilised microbubble contrast agents and improvements in available ultrasonic equipment, such as harmonic imaging, have enabled us to display microbubble enhancements on a gr... Over the last decade, the development of stabilised microbubble contrast agents and improvements in available ultrasonic equipment, such as harmonic imaging, have enabled us to display microbubble enhancements on a greyscale with optimal contrast and spatial resolution. Recent technological advances made contrast harmonic technology available for endoscopic ultrasound(EUS) for the first time in 2008. Thus, the evaluation of microcirculation is now feasible with EUS, prompting the evolution of contrast-enhanced EUS from vascular imaging to images of the perfused tissue. Although the relevant experience is still preliminary, several reports have highlighted contrast-enhanced harmonic EUS(CHEUS) as a promising noninvasive method to visualise and characterise lesions and to differentiate benign from malignant focal lesions. Even if histology remains the gold standard, the combination of CH-EUS and EUS fine needle aspiration(EUS-FNA) can not only render EUS more accurate but may also assist physicians inmaking decisions when EUS-FNA is inconclusive,increasing the yield of EUS-FNA by guiding the puncture with simultaneous imaging of the vascularity.The development of CH-EUS has also opened up exciting possibilities in other research areas,including monitoring responses to anticancer chemotherapy or to ethanolinduced pancreatic tissue ablation,anticancer therapies based on ultrasound-triggered drug and gene delivery,and therapeutic adjuvants by contrast ultrasound-induced apoptosis.Contrast harmonic imaging is gaining popularity because of its efficacy,simplicity and noninvasive nature,and many expectations are currently resting on this technique.If its potential is confirmed in the near future,contrast harmonic imaging will become a standard practice in EUS. 展开更多
关键词 MICROBUBBLES CONTRAST AGENTS contrast-enhanced har
下载PDF
Survival Analysis of Patients Undergoing Intraoperative Contrast-enhanced Ultrasound in the Surgical Treatment of Malignant Glioma
4
作者 Xu CHEN Ya-ni PENG +3 位作者 Fang-ling CHENG Dan CAO An-yu TAO Jian CHEN 《Current Medical Science》 SCIE CAS 2024年第2期399-405,共7页
Objective:Complete resection of malignant gliomas is often challenging.Our previous study indicated that intraoperative contrast-enhanced ultrasound(ICEUS)could aid in the detection of residual tumor remnants and the ... Objective:Complete resection of malignant gliomas is often challenging.Our previous study indicated that intraoperative contrast-enhanced ultrasound(ICEUS)could aid in the detection of residual tumor remnants and the total removal of brain lesions.This study aimed to investigate the survival rates of patients undergoing resection with or without the use of ICEUS and to assess the impact of ICEUS on the prognosis of patients with malignant glioma.Methods:A total of 64 patients diagnosed with malignant glioma(WHO grade HI and IV)who underwent surgery between 2012 and 2018 were included.Among them,29 patients received ICEUS.The effects of ICEUS on overall survival(OS)and progression-free survival(PFS)of patients were evaluated.A quantitative analysis was performed to compare ICEUS parameters between gliomas and the surrounding tissues.Results:The ICEUS group showed better survival rates both in OS and PFS than the control group.The univariate analysis revealed that age,pathology and ICEUS were significant prognostic factors for PFS,with only age being a significant prognostic factor for OS.In multivariate analysis,age and ICEUS were significant prognostic factors for both OS and PFS.The quantitative analysis showed that the intensity and transit time of microbubbles reaching the tumors were significantly different from those of microbubbles reaching the surrounding tissue.Conclusion:ICEUS facilitates the identification of residual tumors.Age and ICEUS are prognostic factors for malignant glioma surgery,and use of ICEUS offers a better prognosis for patients with malignant glioma. 展开更多
关键词 intraoperative contrast-enhanced ultrasound malignant glioma extent of resection SURVIVAL PROGNOSIS
下载PDF
Modulation of High-Order Harmonic Generation from a Monolayer ZnO by Co-rotating Two-Color Circularly Polarized Laser Fields
5
作者 乔月 陈家祺 +3 位作者 周书山 陈基根 蒋士成 杨玉军 《Chinese Physics Letters》 SCIE EI CAS CSCD 2024年第1期34-38,共5页
By numerically solving the two-dimensional semiconductor Bloch equation,we study the high-order harmonic emission of a monolayer ZnO under the driving of co-rotating two-color circularly polarized laser pulses.By chan... By numerically solving the two-dimensional semiconductor Bloch equation,we study the high-order harmonic emission of a monolayer ZnO under the driving of co-rotating two-color circularly polarized laser pulses.By changing the relative phase between the fundamental frequency field and the second one,it is found that the harmonic intensity in the platform region can be significantly modulated.In the higher order,the harmonic intensity can be increased by about one order of magnitude.Through time-frequency analysis,it is demonstrated that the emission trajectory of monolayer ZnO can be controlled by the relative phase,and the harmonic enhancement is caused by the second quantum trajectory with the higher emission probability.In addition,near-circularly polarized harmonics can be generated in the co-rotating two-color circularly polarized fields.With the change of the relative phase,the harmonics in the platform region can be altered from left-handed near-circularly polarization to right-handed one.Our results can obtain high-intensity harmonic radiation with an adjustable ellipticity,which provides an opportunity for syntheses of circularly polarized attosecond pulses. 展开更多
关键词 POLARIZATION ROTATING harmonic
下载PDF
High-order harmonic generation of ZnO crystals in chirped and static electric fields
6
作者 张玲玉 何永林 +5 位作者 谢卓璇 高芳艳 徐清芸 葛鑫磊 罗香怡 郭静 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第1期335-343,共9页
High harmonic generation in ZnO crystals under chirped single-color field and static electric field are investigated by solving the semiconductor Bloch equation(SBE). It is found that when the chirp pulse is introduce... High harmonic generation in ZnO crystals under chirped single-color field and static electric field are investigated by solving the semiconductor Bloch equation(SBE). It is found that when the chirp pulse is introduced, the interference structure becomes obvious while the harmonic cutoff is not extended. Furthermore, the harmonic efficiency is improved when the static electric field is included. These phenomena are demonstrated by the classical recollision model in real space affected by the waveform of laser field and inversion symmetry. Specifically, the electron motion in k-space shows that the change of waveform and the destruction of the symmetry of the laser field lead to the incomplete X-structure of the crystal-momentum-resolved(k-resolved) inter-band harmonic spectrum. Furthermore, a pre-acceleration process in the solid four-step model is confirmed. 展开更多
关键词 high-order harmonic generation the semiconductor Bloch equation k-resolved inter-band harmonic spectrum four-step semiclassical model
下载PDF
Double contrast-enhanced ultrasonography improves diagnostic accuracy of T staging compared with multi-detector computed tomography in gastric cancer patients
7
作者 Yan-Fen Xu Hui-Yun Ma +4 位作者 Gui-Ling Huang Yu-Ting Zhang Xue-Yan Wang Ming-Jie Wei Xiao-Qing Pei 《World Journal of Gastroenterology》 SCIE CAS 2024年第23期3005-3015,共11页
BACKGROUND Gastric cancer(GC)is the most common malignant tumor and ranks third for cancer-related deaths among the worldwide.The disease poses a serious public health problem in China,ranking fifth for incidence and ... BACKGROUND Gastric cancer(GC)is the most common malignant tumor and ranks third for cancer-related deaths among the worldwide.The disease poses a serious public health problem in China,ranking fifth for incidence and third for mortality.Knowledge of the invasive depth of the tumor is vital to treatment decisions.AIM To evaluate the diagnostic performance of double contrast-enhanced ultrasonography(DCEUS)for preoperative T staging in patients with GC by comparing with multi-detector computed tomography(MDCT).METHODS This single prospective study enrolled patients with GC confirmed by preoperative gastroscopy from July 2021 to March 2023.Patients underwent DCEUS,including ultrasonography(US)and intravenous contrast-enhanced ultrasonography(CEUS),and MDCT examinations for the assessment of preoperative T staging.Features of GC were identified on DCEUS and criteria developed to evaluate T staging according to the 8th edition of AJCC cancer staging manual.The diagnostic performance of DCEUS was evaluated by comparing it with that of MDCT and surgical-pathological findings were considered as the gold standard.RESULTS A total of 229 patients with GC(80 T1,33 T2,59 T3 and 57 T4)were included.Overall accuracies were 86.9%for DCEUS and 61.1%for MDCT(P<0.001).DCEUS was superior to MDCT for T1(92.5%vs 70.0%,P<0.001),T2(72.7%vs 51.5%,P=0.041),T3(86.4%vs 45.8%,P<0.001)and T4(87.7%vs 70.2%,P=0.022)staging of GC.CONCLUSION DCEUS improved the diagnostic accuracy of preoperative T staging in patients with GC compared with MDCT,and constitutes a promising imaging modality for preoperative evaluation of GC to aid individualized treatment decision-making. 展开更多
关键词 Double contrast-enhanced ultrasonography Multi-detector computed tomography Gastric cancer T staging
下载PDF
Tunable spectral continuous shift of high-order harmonic generation in atoms by a plasmon-assisted shaping pulse
8
作者 王源 李玉龙 +7 位作者 乔月 高娜 郭福明 陈洲 赫兰海 杨玉军 赵曦 王俊 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期433-440,共8页
We delve into the phenomenon of high-order harmonic generation within a helium atom under the influence of a plasmon-assisted shaping pulse.Our findings reveal an intriguing manipulation of the frequency peak position... We delve into the phenomenon of high-order harmonic generation within a helium atom under the influence of a plasmon-assisted shaping pulse.Our findings reveal an intriguing manipulation of the frequency peak position in the harmonic emission by adjusting the absolute phase parameter within the frequency domain of the shaping pulse.This phenomenon holds potential significance for experimental setups necessitating precisely tuned single harmonics.Notably,we observe a modulated shift in the created harmonic photon energy,spanning an impressive range of 1.2 eV.This frequency peak shift is rooted in the asymmetry exhibited by the rising and falling edges of the laser pulse,directly influencing the position of the peak frequency emission.Our study quantifies the dependence of this tuning range and the asymmetry of the laser pulse,offering valuable insights into the underlying mechanisms driving this phenomenon.Furthermore,our investigation uncovers the emergence of semi-integer order harmonics as the phase parameter is altered.We attribute this discovery to the intricate interference between harmonics generated by the primary and secondary return cores.This observation introduces an innovative approach for generating semi-integer order harmonics,thus expanding our understanding of high-order harmonic generation.Ultimately,our work contributes to the broader comprehension of complex phenomena in laser-matter interactions and provides a foundation for harnessing these effects in various applications,particularly those involving precise spectral control and the generation of unique harmonic patterns. 展开更多
关键词 high-order harmonic semi-integer-order spectra shift inhomogeneous field
下载PDF
Gastrointestinal contrast-enhanced ultrasonography for diagnosis and treatment of peptic ulcer in children
9
作者 Yu-Hua Zhang Zhi-Hua Xu +1 位作者 Shuang-Shuang Ni Hong-Xia Luo 《World Journal of Gastroenterology》 SCIE CAS 2024年第7期705-713,共9页
BACKGROUND The detection rate of peptic ulcer in children is improving,with development of diagnostic procedures.Gastroscopy is the gold standard for the diagnosis of peptic ulcer,but it is an invasive procedure.Gastr... BACKGROUND The detection rate of peptic ulcer in children is improving,with development of diagnostic procedures.Gastroscopy is the gold standard for the diagnosis of peptic ulcer,but it is an invasive procedure.Gastrointestinal contrast-enhanced ultrasonography(CEUS)has the advantages of being painless,noninvasive,nonradioactive,easy to use,and safe.AIM To investigate the clinical value of CEUS for diagnosis and treatment of peptic ulcer in children.METHODS We investigated 43 children with digestive tract symptoms in our hospital from January 2021 to June 2022.All children were examined by routine ultrasound,gastrointestinal CEUS,and gastroscopy.The pathological results of gastroscopy were taken as the gold standard.Routine ultrasonography was performed before gastrointestinal CEUS.Conventional ultrasound showed the thickness of the gastroduodenal wall,gastric peristalsis,and the adjacent organs and tissues around the abdominal cavity.Gastrointestinal CEUS recorded the thickness of the gastroduodenal wall;the size,location and shape of the ulcer;gastric peristalsis;and adjacent organs and tissues around the abdominal cavity.The results of routine ultrasound and gastrointestinal ultrasound were compared with those of gastroscopy to evaluate the diagnostic results and coincidence rate of routine ultrasound and gastrointestinal CEUS.All children received informed consent from their guardians for CEUS.This study was reviewed and approved by the hospital medical ethics committee.RESULTS Among the 43 children,17(15 male,2 female)were diagnosed with peptic ulcer by gastroscopy.There were 26 children with nonpeptic ulcer.There were eight cases of peptic ulcer and 35 of nonpeptic ulcer diagnosed by conventional ultrasound.The diagnostic coincidence rate of peptic ulcer in children diagnosed by conventional ultrasound was 79.1%(34/43),which was significantly different from that of gastroscopy(P=0.033).It indicates that the coincidence rate of gastrointestinal contrast-enhanced ultrasound and gastroscope is low.Fifteen cases of peptic ulcer and 28 of nonpeptic ulcer were diagnosed by CEUS.The diagnostic coincidence rate of peptic ulcer in children was 95.3%(41/43).There was no significant difference between CEUS and gastroscopy(P=0.655).It indicates that the coincidence rate of gastrointestinal contrast-enhanced ultrasound and gastroscope is high.CONCLUSION Gastrointestinal CEUS has a high coincidence rate in the diagnosis of peptic ulcer in children,and can be used as a preliminary examination method. 展开更多
关键词 contrast-enhanced ultrasound Peptic ulcer CHILDREN Gastrointestinal tract Abdominal pain Acoustic contrast agent
下载PDF
Clinical value of oral contrast-enhanced ultrasonography in diagnosis of gastric tumors
10
作者 Chuan-Yu Wang Xiao-Jing Fan +6 位作者 Fei-Liang Wang Yue-Yue Ge Zhao Cai Wei Wang Xin-Ping Zhou Jun Du De-Wei Dai 《World Journal of Gastrointestinal Oncology》 SCIE 2024年第1期110-117,共8页
BACKGROUND The incidence of gastric cancer remains high,and it is the sixth most common cancer and the fourth leading cause of cancer deaths worldwide.Oral contrastenhanced ultrasonography is a simple,non-invasive,and... BACKGROUND The incidence of gastric cancer remains high,and it is the sixth most common cancer and the fourth leading cause of cancer deaths worldwide.Oral contrastenhanced ultrasonography is a simple,non-invasive,and painless method for the diagnosis of gastric tumors.AIM To explore the diagnostic value of oral contrast-enhanced ultrasonography for the detection of gastric tumors.METHODS The screening results based on oral contrast-enhanced ultrasonography and electronic gastroscopy were compared with those of the postoperative pathological examination.RESULTS Among 42 patients with gastric tumors enrolled in the study,the diagnostic accordance rate was 95.2%for oral contrast-enhanced ultrasonography(n=40)and 90.5%for electronic gastroscopy(n=38)compared with postoperative pathological examination.The Kappa value of consistency test with pathological findings was 0.812 for oral contrast-enhanced ultrasonography and 0.718 for electronic gastroscopy,and there was no significant difference between them(P=0.397).For the TNM staging of gastric tumors,the accuracy rate of oral contrast enhanced ultrasonography was 81.9%for the overall T staging and 50%,77.8%,100%,and 100%for T1,T2,T3,and T4 staging,respectively.The sensitivity and specificity were both 100%for stages T3 and T4.The diagnostic accuracy rate of oral contrast-enhanced ultrasonography was 93.8%,80%,100%,and 100%for stages N0,N1-N3,M0,and M1,respectively.CONCLUSION The accordance rate of qualitative diagnosis by oral contrast-enhanced ultrasonography is comparable to that of gastroscopy,and it could be used as the preferred method for the early screening of gastric tumors. 展开更多
关键词 Oral contrast-enhanced ultrasonography Gastric tumor Electronic gastroscopy Controlled study Pathological examination DIAGNOSIS
下载PDF
Terahertz quasi-perfect vortex beam with integer-order and fractional-order generated by spiral spherical harmonic axicon
11
作者 涂思语 刘德峰 +2 位作者 刘劲松 杨振刚 王可嘉 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第1期458-467,共10页
We propose a new method to generate terahertz perfect vortex beam with integer-order and fractional-order. A new optical diffractive element composed of the phase combination of a spherical harmonic axicon and a spira... We propose a new method to generate terahertz perfect vortex beam with integer-order and fractional-order. A new optical diffractive element composed of the phase combination of a spherical harmonic axicon and a spiral phase plate is designed and called spiral spherical harmonic axicon. A terahertz Gaussian beam passes through the spiral spherical harmonic axicon to generate a terahertz vortex beam. When only the topological charge number carried by spiral spherical harmonic axicon increases, the ring radius of terahertz vortex beam increases slightly, so the beam is shaped into a terahertz quasi-perfect vortex beam. Importantly, the terahertz quasi-perfect vortex beam can carry not only integer-order topological charge number but also fractional-order topological charge number. This is the first time that vortex beam and quasi-perfect vortex beam with fractional-order have been successfully realized in terahertz domain and experiment. 展开更多
关键词 TERAHERTZ spiral spherical harmonic axicon quasi-perfect vortex beam topological charge number
下载PDF
Contrast-enhanced guided endoscopic ultrasound procedures
12
作者 Marcel Ioan Gheorghiu Andrada Seicean +3 位作者 Cristina Pojoga Claudia Hagiu Radu Seicean Zeno Sparchez 《World Journal of Gastroenterology》 SCIE CAS 2024年第17期2311-2320,共10页
Contrast-enhanced endoscopic ultrasound(CH-EUS)can overcome the limi-tations of endoscopic ultrasound-guided acquisition by identifying microvessels inside inhomogeneous tumours and improving the characterization of t... Contrast-enhanced endoscopic ultrasound(CH-EUS)can overcome the limi-tations of endoscopic ultrasound-guided acquisition by identifying microvessels inside inhomogeneous tumours and improving the characterization of these tumours.Despite the initial enthusiasm that oriented needle sampling under CH-EUS guidance could provide better diagnostic yield in pancreatic solid lesions,further studies did not confirm the supplementary values in cases of tissue acquisition guided by CH-EUS.This review details the knowledge based on the available data on contrast-guided procedures.The indications for CH-EUS tissue acquisition include isoechoic EUS lesions with poor visible delineation where CH-EUS can differentiate the lesion vascularisation from the surrounding parenchyma and also the mural nodules within biliopancreatic cystic lesions,which occur in select cases.Additionally,the roles of CH-EUS-guided therapy in patients whose pancreatic fluid collections or bile ducts that have an echogenic content have indications for drainage,and patients who have nonvisualized vessels that need to be highlighted via Doppler EUS are presented.Another indication is represented if there is a need for an immediate assessment of the post-radiofrequency ablation of pancreatic neuroendocrine tumours,in which case CH-EUS can be used to reveal the incomplete tumour destruction. 展开更多
关键词 ENDOSONOGRAPHY contrast-enhanced endoscopic ultrasound Tissue acquisition Fine needle aspiration Fine needle biopsy Drainage Pancreatic fluid collections BIOPSY PANCREAS
下载PDF
ESTIMATE ON THE BLOCH CONSTANT FOR CERTAIN HARMONIC MAPPINGS UNDER A DIFFERENTIAL OPERATOR
13
作者 陈洁玲 刘名生 《Acta Mathematica Scientia》 SCIE CSCD 2024年第1期295-310,共16页
In this paper,we first obtain the precise values of the univalent radius and the Bloch constant for harmonic mappings of the formL(f)=zfz-zfz,where f represents normalized harmonic mappings with bounded dilation.Then,... In this paper,we first obtain the precise values of the univalent radius and the Bloch constant for harmonic mappings of the formL(f)=zfz-zfz,where f represents normalized harmonic mappings with bounded dilation.Then,using these results,we present better estimations for the Bloch constants of certain harmonic mappings L(f),where f is a K-quasiregular harmonic or open harmonic.Finally,we establish three versions of BlochLandau type theorem for biharmonic mappings of the form L(f).These results are sharp in some given cases and improve the related results of earlier authors. 展开更多
关键词 Bloch-Landau type theorem Bloch constant linear complex operator harmonic mapping biharmonic mapping UNIVALENT
下载PDF
Elliptically polarized high-order harmonic generation of Ar atom in an intense laser field
14
作者 胡杰 王一琛 +6 位作者 景秋霜 姜威 王革文 赵逸文 肖礴 梁红静 马日 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第5期453-457,共5页
High-order harmonic generation(HHG) of Ar atom in an elliptically polarized intense laser field is experimentally investigated in this work.Interestingly,the anomalous ellipticity dependence on the laser ellipticity(... High-order harmonic generation(HHG) of Ar atom in an elliptically polarized intense laser field is experimentally investigated in this work.Interestingly,the anomalous ellipticity dependence on the laser ellipticity(ε) in the lower-order harmonics is observed,specifically in the 13rd-order,which displays a maximal harmonic intensity at ε ≈ 0.1,rather than at ε = 0 as expected.This contradicts the general trend of harmonic yield,which typically decreases with the increase of laser ellipticity.In this study,we attribute this phenomenon to the disruption of the symmetry of the wave function by the Coulomb effect,leading to the generation of a harmonic with high ellipticity.This finding provides valuable insights into the behavior of elliptically polarized harmonics and opens up a potential way for exploring new applications in ultrafast spectroscopy and light–matter interactions. 展开更多
关键词 high-order harmonic generation Coulomb effect elliptically polarized intense laser field
下载PDF
Optimization of extreme ultraviolet vortex beam based on high harmonic generation
15
作者 肖礴 赵逸文 +6 位作者 程方晶 王革文 姜威 王一琛 胡杰 梁红静 马日 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第5期459-464,共6页
In high harmonic generation(HHG),Laguerre–Gaussian(LG) beams are used to generate extreme ultraviolet(XUV)vortices with well-defined orbital angular momentum(OAM),which have potential applications in fields such as m... In high harmonic generation(HHG),Laguerre–Gaussian(LG) beams are used to generate extreme ultraviolet(XUV)vortices with well-defined orbital angular momentum(OAM),which have potential applications in fields such as microscopy and spectroscopy.An experimental study on the HHG driven by vortex and Gaussian beams is conducted in this work.It is found that the intensity of vortex harmonics is positively correlated with the laser energy and gas pressure.The structure and intensity distribution of the vortex harmonics exhibit significant dependence on the relative position between the gas jet and the laser focus.The ring-like structures observed in the vortex harmonics,and the interference of quantum paths provide an explanation for the distinct structural characteristics.Moreover,by adjusting the relative position between the jet and laser focus,it is possible to discern the contributions from different quantum paths.The optimization of the HH vortex field is applicable to the XUV,which opens up a new way for exploiting the potential in optical spin or manipulating electrons by using the photon with tunable orbital angular momentum. 展开更多
关键词 high harmonic generation phase matching extreme ultraviolet vortex beam quantum path interference
下载PDF
Harmonic balance simulation of the influence of component uniformity and reliability on the performance of a Josephson traveling wave parametric amplifier
16
作者 郑煜臻 熊康林 +1 位作者 冯加贵 杨辉 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第4期339-343,共5页
A Josephson traveling wave parametric amplifier(JTWPA),which is a quantum-limited amplifier with high gain and large bandwidth,is the core device of large-scale measurement and control systems for quantum computing.A ... A Josephson traveling wave parametric amplifier(JTWPA),which is a quantum-limited amplifier with high gain and large bandwidth,is the core device of large-scale measurement and control systems for quantum computing.A typical JTWPA consists of thousands of Josephson junctions connected in series to form a transmission line and hundreds of shunt LC resonators periodically loaded along the line for phase matching.Because the variation of these capacitors and inductors can be detrimental to their high-frequency characteristics,the fabrication of a JTWPA typically necessitates precise processing equipment.To guide the fabrication process and further improve the design for manufacturability,it is necessary to understand how each electronic component affects the amplifier.In this paper,we use the harmonic balance method to conduct a comprehensive study on the impact of nonuniformity and fabrication yield of the electronic components on the performance of a JTWPA.The results provide insightful and scientific guidance for device design and fabrication processes. 展开更多
关键词 Josephson traveling wave parametric amplifier(JTWPA) harmonic balance method YIELDS UNIFORMITY
下载PDF
Harmonics in the Squirrel Cage Induction Motor Analytic Calculation Part III: Influence on the Torque-speed Characteristic
17
作者 G.Kovács 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第1期86-102,共17页
The harmonics that appear in the squirrel cage asynchronous machine have been discussed in great detail in the literature for a long time. However, the systematization of the phenomenon is still pending, so we made an... The harmonics that appear in the squirrel cage asynchronous machine have been discussed in great detail in the literature for a long time. However, the systematization of the phenomenon is still pending, so we made an attempt to fill this gap in the previous parts of our study by elaborating formulas for calculation of parasitic torques. It was a general demand among those who work in this field towards the author to verify his formulas with measurements. In the literature, it seems,only one detailed, purposeful series of measurements has been published so far, the purpose of which was to investigate the effect of the number of rotor slots on the torque-speed characteristic curve of the machine. The main goal of this study is to verify the correctness of the formulas by comparing them with the referred series of measurements. Relying on this, the expected synchronous parasitic torques were developed for the frequently used rotor slot numbers-as a design guide for the engineer.Thus, together with our complete table for radial magnetic pull published in our previous work, the designer has all the principles, data and formulas available for the right number of rotor slots for his given machine and for the drive system. This brings this series of papers to an end. 展开更多
关键词 Asynchronous parasitic torques Induction motor Squirrel cage rotor Space harmonics Synchronous parasitic torques
下载PDF
Airgap-harmonic-oriented Partitioned Design Method of PMV Motor with Improved Torque Performances
18
作者 Zhaopeng Wu Li Quan +3 位作者 Zixuan Xiang Deyang Fan Tengguang Wang Xiaoyong Zhu 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第1期43-50,共8页
Here,we introduce a partitioned design method that is oriented toward airgap harmonic for permanent magnet vernier(PMV)motors.The method proposes the utilization of airgap flux harmonics as an effective bridge between... Here,we introduce a partitioned design method that is oriented toward airgap harmonic for permanent magnet vernier(PMV)motors.The method proposes the utilization of airgap flux harmonics as an effective bridge between the torque design region and the torque performances.To illustrate the efficacy of this method,a partitioned design PMV motor is presented and compared with the initial design.Firstly,the torque design region of the rotor is artfully divided into the torque enhancement region and ripple reduction region.Meanwhile,the main harmonics that generate output torque are chosen and enhanced,optimization.Moreover,the harmonics that generate torque ripple are selected and reduced based on torque harmonics optimization.Finally,the functions of the partitioned PMV motor torque are assessed based on the finite element method.By the purposeful design of these two regions,the output torque is strengthened while torque ripple is inhibited effectively,verifying the effectiveness and reasonability of the proposed design method. 展开更多
关键词 Permanent magnet vernier(PMV)motor Airgap flux harmonic Partitioned design Low torque ripple
下载PDF
Wavelength Dependent Nonlinear Spectroscopic Study of Third Harmonic Generation Probed by Rotational Maker Fringes Method
19
作者 Calford Odhiambo Otieno 《Open Journal of Microphysics》 2024年第2期13-23,共11页
Efficient third-order nonlinearities of the Zinc Oxide and Al-doped Zinc Oxide were studied by Third Harmonic Generation (Third Harmonic Generation) Maker fringes to establish the effect Aluminum of Aluminum doping (A... Efficient third-order nonlinearities of the Zinc Oxide and Al-doped Zinc Oxide were studied by Third Harmonic Generation (Third Harmonic Generation) Maker fringes to establish the effect Aluminum of Aluminum doping (Al-doping) on the cubic nonlinearities. Adding the Al-dopant to the Zinc Oxide crystal structure results in changes that affect the optical and nonlinear characteristics. Presented results indicate that the magnitude of X<sup>(3)</sup> was enhanced at single experimental wavelengths;however, across the broadband experimental spectrum, the effect of Al-doping remained relatively constant. The observed enhancement of third-order nonlinearity was purely from the bound electronic response. The observation is attributed to increased charge carriers and spontaneous polarization in the Zinc Oxide and Al-doped Zinc Oxide crystal structure. 展开更多
关键词 Nonlinear Optics harmonic Generation Maker Fringes Zinc Oxide
下载PDF
Identities on q-Harmonic Numbers
20
作者 Mengxiao Zhou Haitao Jin Huanhuan Zheng 《Journal of Applied Mathematics and Physics》 2024年第5期1796-1803,共8页
With the help of the classical Abel’s lemma on summation by parts and algorithm of q-hypergeometric summations, we deal with the summation, which can be written as multiplication of a q-hypergeometric term and q-harm... With the help of the classical Abel’s lemma on summation by parts and algorithm of q-hypergeometric summations, we deal with the summation, which can be written as multiplication of a q-hypergeometric term and q-harmonic numbers. This enables us to construct and prove identities on q-harmonic numbers. Several examples are also given. 展开更多
关键词 harmonic Numbers q-Zeilberger Algorithm Abel’s Lemma
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部