The high summer indoor temperature in agricultural greenhouse is not conducive to crop growth,so it is necessary to cool the greenhouse. In this study,taking the agricultural multi-span greenhouse with strong temperat...The high summer indoor temperature in agricultural greenhouse is not conducive to crop growth,so it is necessary to cool the greenhouse. In this study,taking the agricultural multi-span greenhouse with strong temperature adjustment ability for example,we make an experimental analysis on the temperature changes inside and outside the greenhouse under nine different equipment combinations( fan,skylight,sunshade,sunshade + fan,cooling pad + fan,skylight + fan,sunshade + skylight,sunshade + fan + cooling pad,sunshade + skylight + fan),respectively,and conduct the overall assessment on the measures to cool the summer agricultural greenhouse,in order to provide a reference for selecting a cost-effective cooling method for greenhouse. Tests show that the three treatment modes of fan,sunshade and sunshade + fan almost have no cooling capacity; skylight,sunshade + skylight have cooling capacity,but the effect is slow; cooling pad + fan,sunshade + skylight +fan can reduce the indoor temperature,but the effect is not very good; skylight and fan have good cooling effect; sunshade + fan + cooling pad has obvious cooling effect,which can well meet the cooling needs in the summer greenhouse.展开更多
The influence of the panel position on the cooling performance of a radiant panel is analyzed.The coupled simulation of convection and radiation is set up by a computational fluid dynamics(CFD)method.The simulations...The influence of the panel position on the cooling performance of a radiant panel is analyzed.The coupled simulation of convection and radiation is set up by a computational fluid dynamics(CFD)method.The simulations with different panel positions and different indoor heat sources are used to calculate the cooling capacity of the radiant panel and the indoor thermal environment.The simulation results are in good agreement with the experimental results.The results show that when the indoor heat source temperature is low,the convective heat flux is the main influence factor of the cooling capacity and the radiant panel should be placed on the wall or on the ceiling.Otherwise,when the indoor heat source temperature is high,the radiation heat flux is the main factor and the radiant panel should be placed as near to the heat sources as possible.展开更多
The biggest challenge for organic phase change materials(PCMs)used in cold energy storage is to maintain high heat storage capacity while reducing the leakage risk of PCMs during the phase transition process.This is c...The biggest challenge for organic phase change materials(PCMs)used in cold energy storage is to maintain high heat storage capacity while reducing the leakage risk of PCMs during the phase transition process.This is crucial for expanding their applications in the more demanding cold storage field.In this study,novel formstable low-temperature composite PCMs are prepared with mesoporous materials,namely SBA-15 and CMK-3(which are prepared using the template method),as supporting matrices and dodecane as the PCM.Owing to the combined effects of capillary forces within mesoporous materials and interactions among dodecane molecules,both dodecane/SBA-15 and dodecane/CMK-3 exhibit outstanding shape stability and thermal cycling stability even after 200 heating/cooling cycles.In comparison to those of dodecane/SBA-15,dodecane/CMK-3 exhibits superior cold storage performance and higher thermal conductivity.Specifically,the phase transition temperature of dodecane/CMK-3 is-8.81℃ with a latent heat of 122.4 J·g^(-1).Additionally,it has a thermal conductivity of 1.21 W·m^(-1)·K^(-1),which is 9.45 times that of dodecane alone.All these highlight its significant potential for applications in the area of cold energy storage.展开更多
Earth tubes are earth-to-air heat exchangers that are frequently utilized in energy conscious low-rise buildings, but are scarcely reported for tall buildings. The feasibility of applying earth tube cooling to t...Earth tubes are earth-to-air heat exchangers that are frequently utilized in energy conscious low-rise buildings, but are scarcely reported for tall buildings. The feasibility of applying earth tube cooling to tall buildings in a hot summer and cold winter climate zone was studied in this paper. Firstly, the designed cooling load of a tall building was obtained from the energy simulation using the baseline and the modified models with applicable energy efficiency measures. Based on the load, the required cooling capacity, the overall section area and the effective length of the earth tube system was deduced from the heat transfer and fluid flow calculation analytically. Then the performance of the earth tube system was crosschecked and verified via the Computational Fluid Dynamics (CFD) simulation. In the CFD simulation, earth tubes with different diameters and lengths, as well as a full-scale earth tube model with surrounding soil above the depth of constant temperature, were investigated. The outlet air temperatures of the full-scale models were computed with the consideration of different axial distances between adjacent tubes. Meanwhile, multiple conceptual design schemes and the tunnel construction method for the earth tube system were proposed from the perspective of performance enhancement, constructability, efficiency and economy. It revealed that earth tube systems are conditionally feasible for some tall buildings if their design guidelines for climate, underground spaces, construction method, friction of tube interior surface, optimization of effective length and axial distance, as well as synergy with other energy efficiency measures are followed. Even the cooling capacity of earth tubes degrade with time due to the accumulated heat underground, but in a hot summer and cold winter climate zone it can still possibly produce cooled air for a tall building with a Floor Area Ratio of less than 7 effectively in summer.展开更多
In this paper, the theoretical analysis and simulating calculation were conducted for a basic two-stage semiconductor thermoelectric module, which contains one thermocouple in the second stage and several thermocouple...In this paper, the theoretical analysis and simulating calculation were conducted for a basic two-stage semiconductor thermoelectric module, which contains one thermocouple in the second stage and several thermocouples in the first stage. The study focused on the configuration of the two-stage semiconductor thermoelectric cooler, especially investigating the influences of some parameters, such as the current I1 of the first stage, the area A1 of every thermocouple and the number n of thermocouples in the first stage, on the cooling performance of the module. The obtained results of analysis indicate that changing the current I1 of the first stage, the area A1 of thermocouples and the number n of thermocouples in the first stage can improve the cooling performance of the module. These results can be used to optimize the configuration of the two-stage semiconductor thermoelectric module and provide guides for the design and application of thermoelectric cooler.展开更多
The lattice parameter and magnetocaloric properties of three samples of LaFe11.2Co0.7Si1.1-xGax with x = 0, 0.03 and 0.05 have been investigated by X-ray powder diffraction and magnetization measurements. The lattice ...The lattice parameter and magnetocaloric properties of three samples of LaFe11.2Co0.7Si1.1-xGax with x = 0, 0.03 and 0.05 have been investigated by X-ray powder diffraction and magnetization measurements. The lattice parameter increases slightly and the Curie temperature increases somewhat with increasing gallium content. However, a small amount of Ga doping into the sample decreases the magnetic entropy change of the sample. All the samples remain in the first-order magnetic phase transition. The most striking effect of the Ga doping is that the cooling capacity in the samples increases significantly. The maximum magnetic entropy change, ASM and the cooling capacity of the sample LaFe11.2Co0.7Si1.07Ga0.03 are 11.9 J·kg^-1·K^-1 and 254.8 J·kg^-1, respectively.展开更多
Endothermic hydrocarbon fuels are advanced coolants for high-temperature structures of spacecraft. No data of tested-cooling-ability of endothermic fuels have been broadly discussed in literature. In this work a high-...Endothermic hydrocarbon fuels are advanced coolants for high-temperature structures of spacecraft. No data of tested-cooling-ability of endothermic fuels have been broadly discussed in literature. In this work a high-temperature flow calorimeter was designed, and the cooling capacity of six different hydrocarbon fuels were measured. Experimental results showed that these hydrocarbon fuels have capacity for cooling high-temperature structures, and that the cooling capacity of fuel N-1 can reach 3.15 M J/kg, which can nearly satisfy the requirement of thermal management for a Mach 3 cruise aircraft, whose heat sink requirement is about 3.5 M J/kg. The endothermic velocity of hydrocarbon fuels was also measured by the calorimeter.展开更多
Analyzing the effects of heat rejection from condensers of split-type air-conditioning units at lower-floors of MLABs (multi-level apartment buildings), using field measurements to monitor environmental conditions a...Analyzing the effects of heat rejection from condensers of split-type air-conditioning units at lower-floors of MLABs (multi-level apartment buildings), using field measurements to monitor environmental conditions and condenser operation, revealed increases in the inlet air temperature at the condensers at the upper floors, which in turn increased the power and energy requirements for these units and decreased their cooling capacities. Results indicated that a decrease of up to 16,000 tons in cooling capacity and an increase of up to 67.2 MW in the national peak load demand might be reached for a 4 ℃ temperature differential for Kuwait conditions. It is recommended that the condensers be placed in the wind pathway to minimize the impact of heat rejection and stack effect and to optimize the operation of split-type air-conditioning units, and that other factors regarding installation setup and location are investigated.展开更多
Film cooling is an indispensable scheme in the design of highly-efficient cooling configurations to satisfy the thermal protection requirement of turbine hot section components.During the last few decades,vast efforts...Film cooling is an indispensable scheme in the design of highly-efficient cooling configurations to satisfy the thermal protection requirement of turbine hot section components.During the last few decades,vast efforts have been paid on the discrete-hole film cooling enhancement.In this paper,some of the recent literatures related to the passive strategies(such as shaped film cooling holes,upstream ramps,shallow trenches,mesh-fed slots)and the active strategies(such as the use of pulsation modulating device or plasma actuator)for film cooling enhancement are surveyed,with the aim at presenting an updated overview about the state of the art in advanced film cooling.In addition,some challenging issues are also outlined to motivate further investigations in such a broad topic.展开更多
The cooling performance of air-cooled condenser(ACC)is susceptible to adverse impacts of ambient winds.In this work,three kinds of lateral double-layered deflectors installed under the ACC platform are proposed to wea...The cooling performance of air-cooled condenser(ACC)is susceptible to adverse impacts of ambient winds.In this work,three kinds of lateral double-layered deflectors installed under the ACC platform are proposed to weaken the unfavorable effects of cross winds.Through CFD simulation methods,the main parameters of thermo-flow performances of a 2×660 MW direct dry cooling system are obtained,by which it can be concluded that the deflectors can effectively reduce the inlet air temperatures while enhance the mass flow rates of upwind fans due to the guiding effect,especially at high wind speeds,while the improvement of cooling capacity of ACCs in the 0°wind direction is weak.The inclined-vertical deflectors are superior to others in performance improvement of ACCs for all cases,which can reduce the turbine back pressure by 12.15%when the wind speed is 12 m/s,so they can be applied to the performance enhancement of ACCs under windy conditions in practical engineering.展开更多
This article presents an innovative facade system designed to increase the thermal comfort inside an office room and to enhance the cooling capacity of the suspended cooling ceiling. A series of measurements is conduc...This article presents an innovative facade system designed to increase the thermal comfort inside an office room and to enhance the cooling capacity of the suspended cooling ceiling. A series of measurements is conducted in an existing office building with different facade systems (i.e., a combination of grazing and shading). An innovative facade system is devetoped based on this intensive set of measurements. The new system enhances the thermal comfort and cooling capacity of the suspended cooling ceiling. The main usage of the new system is the refurbishment and improvement of existing facade systems.展开更多
As an important component of the stirling-type pulse tube cryocooler(SPTC),an efficient phase shifter can significantly improve the cooling capacity.Compared to the common phase shifter,the active warm displacer(AWD)h...As an important component of the stirling-type pulse tube cryocooler(SPTC),an efficient phase shifter can significantly improve the cooling capacity.Compared to the common phase shifter,the active warm displacer(AWD)has a wider phase adjustment range and therefore can obtain a better phase relationship easily.Based on a two-stage thermal-coupled SPTC operating in the 20 K range,this paper studied the influence of the swept volume ratio between the compressor and displacer.The research found that the swept volume ratio changes the cooling capacity and efficiency of the cryocooler mainly by changing the phase difference between the pressure wave and the volume flow at the cold end.It was found from the results of the simulation and experiments that there is an optimal displacement of the displacer(Xd)of 2.5 mm and an optimal phase angle of 15°to obtain the highest cooling efficiency while the displacement of the compressor is constant.The cooling capacity at 20 K is 1.3 W while the input electrical power of the second stage compressor is 202 W,which indicates an overall relative Carnot efficiency(rCOP)of 0.055 in terms of input electrical power.In addition,due to the reasonable setting of precooling temperature and capacity,the swept volume ratio and phase at the maximum cooling capacity and maximum efficiency are consistent in this study.The research improves the understanding of phase shifters and has guiding significance for the optimization of the SPTC working below 20 K.展开更多
基金Supported by Scientific and Technological Achievement Extension Project of Experimental Demonstration Station(Base)in Northwest A&F University(TGZX2016-31)Xi'an Science and Technology Project(NC1504 3)
文摘The high summer indoor temperature in agricultural greenhouse is not conducive to crop growth,so it is necessary to cool the greenhouse. In this study,taking the agricultural multi-span greenhouse with strong temperature adjustment ability for example,we make an experimental analysis on the temperature changes inside and outside the greenhouse under nine different equipment combinations( fan,skylight,sunshade,sunshade + fan,cooling pad + fan,skylight + fan,sunshade + skylight,sunshade + fan + cooling pad,sunshade + skylight + fan),respectively,and conduct the overall assessment on the measures to cool the summer agricultural greenhouse,in order to provide a reference for selecting a cost-effective cooling method for greenhouse. Tests show that the three treatment modes of fan,sunshade and sunshade + fan almost have no cooling capacity; skylight,sunshade + skylight have cooling capacity,but the effect is slow; cooling pad + fan,sunshade + skylight +fan can reduce the indoor temperature,but the effect is not very good; skylight and fan have good cooling effect; sunshade + fan + cooling pad has obvious cooling effect,which can well meet the cooling needs in the summer greenhouse.
基金The National Natural Science Foundation of China(No.50778094)
文摘The influence of the panel position on the cooling performance of a radiant panel is analyzed.The coupled simulation of convection and radiation is set up by a computational fluid dynamics(CFD)method.The simulations with different panel positions and different indoor heat sources are used to calculate the cooling capacity of the radiant panel and the indoor thermal environment.The simulation results are in good agreement with the experimental results.The results show that when the indoor heat source temperature is low,the convective heat flux is the main influence factor of the cooling capacity and the radiant panel should be placed on the wall or on the ceiling.Otherwise,when the indoor heat source temperature is high,the radiation heat flux is the main factor and the radiant panel should be placed as near to the heat sources as possible.
基金supported by the National Natural Science Foundation of China(Grant No.51906230)the Key scientific and technological projects in Henan Province(Grant No.212102210007)the Project of Zhongyuan Science and Technology Innovation Talents(Grant No.234200510011).
文摘The biggest challenge for organic phase change materials(PCMs)used in cold energy storage is to maintain high heat storage capacity while reducing the leakage risk of PCMs during the phase transition process.This is crucial for expanding their applications in the more demanding cold storage field.In this study,novel formstable low-temperature composite PCMs are prepared with mesoporous materials,namely SBA-15 and CMK-3(which are prepared using the template method),as supporting matrices and dodecane as the PCM.Owing to the combined effects of capillary forces within mesoporous materials and interactions among dodecane molecules,both dodecane/SBA-15 and dodecane/CMK-3 exhibit outstanding shape stability and thermal cycling stability even after 200 heating/cooling cycles.In comparison to those of dodecane/SBA-15,dodecane/CMK-3 exhibits superior cold storage performance and higher thermal conductivity.Specifically,the phase transition temperature of dodecane/CMK-3 is-8.81℃ with a latent heat of 122.4 J·g^(-1).Additionally,it has a thermal conductivity of 1.21 W·m^(-1)·K^(-1),which is 9.45 times that of dodecane alone.All these highlight its significant potential for applications in the area of cold energy storage.
文摘Earth tubes are earth-to-air heat exchangers that are frequently utilized in energy conscious low-rise buildings, but are scarcely reported for tall buildings. The feasibility of applying earth tube cooling to tall buildings in a hot summer and cold winter climate zone was studied in this paper. Firstly, the designed cooling load of a tall building was obtained from the energy simulation using the baseline and the modified models with applicable energy efficiency measures. Based on the load, the required cooling capacity, the overall section area and the effective length of the earth tube system was deduced from the heat transfer and fluid flow calculation analytically. Then the performance of the earth tube system was crosschecked and verified via the Computational Fluid Dynamics (CFD) simulation. In the CFD simulation, earth tubes with different diameters and lengths, as well as a full-scale earth tube model with surrounding soil above the depth of constant temperature, were investigated. The outlet air temperatures of the full-scale models were computed with the consideration of different axial distances between adjacent tubes. Meanwhile, multiple conceptual design schemes and the tunnel construction method for the earth tube system were proposed from the perspective of performance enhancement, constructability, efficiency and economy. It revealed that earth tube systems are conditionally feasible for some tall buildings if their design guidelines for climate, underground spaces, construction method, friction of tube interior surface, optimization of effective length and axial distance, as well as synergy with other energy efficiency measures are followed. Even the cooling capacity of earth tubes degrade with time due to the accumulated heat underground, but in a hot summer and cold winter climate zone it can still possibly produce cooled air for a tall building with a Floor Area Ratio of less than 7 effectively in summer.
基金Project supported by the National Basic Research Program of China (Grant Nos G2001039302 and 2007CB307001)the Natural Science Foundation of Guangdong Province (Grant No 2003A1030405)the Natural Science Foundation of Guangzhou City,China (Grant No 1999-Z035-01)
文摘In this paper, the theoretical analysis and simulating calculation were conducted for a basic two-stage semiconductor thermoelectric module, which contains one thermocouple in the second stage and several thermocouples in the first stage. The study focused on the configuration of the two-stage semiconductor thermoelectric cooler, especially investigating the influences of some parameters, such as the current I1 of the first stage, the area A1 of every thermocouple and the number n of thermocouples in the first stage, on the cooling performance of the module. The obtained results of analysis indicate that changing the current I1 of the first stage, the area A1 of thermocouples and the number n of thermocouples in the first stage can improve the cooling performance of the module. These results can be used to optimize the configuration of the two-stage semiconductor thermoelectric module and provide guides for the design and application of thermoelectric cooler.
基金the Opening Foun-dation of Guangxi Key Laboratory for the Advance Materi-als and New Preparation Technology
文摘The lattice parameter and magnetocaloric properties of three samples of LaFe11.2Co0.7Si1.1-xGax with x = 0, 0.03 and 0.05 have been investigated by X-ray powder diffraction and magnetization measurements. The lattice parameter increases slightly and the Curie temperature increases somewhat with increasing gallium content. However, a small amount of Ga doping into the sample decreases the magnetic entropy change of the sample. All the samples remain in the first-order magnetic phase transition. The most striking effect of the Ga doping is that the cooling capacity in the samples increases significantly. The maximum magnetic entropy change, ASM and the cooling capacity of the sample LaFe11.2Co0.7Si1.07Ga0.03 are 11.9 J·kg^-1·K^-1 and 254.8 J·kg^-1, respectively.
基金Project (No. 863-2-1-1-7) supported by the Hi-Tech Research and Development Program (863) of China
文摘Endothermic hydrocarbon fuels are advanced coolants for high-temperature structures of spacecraft. No data of tested-cooling-ability of endothermic fuels have been broadly discussed in literature. In this work a high-temperature flow calorimeter was designed, and the cooling capacity of six different hydrocarbon fuels were measured. Experimental results showed that these hydrocarbon fuels have capacity for cooling high-temperature structures, and that the cooling capacity of fuel N-1 can reach 3.15 M J/kg, which can nearly satisfy the requirement of thermal management for a Mach 3 cruise aircraft, whose heat sink requirement is about 3.5 M J/kg. The endothermic velocity of hydrocarbon fuels was also measured by the calorimeter.
文摘Analyzing the effects of heat rejection from condensers of split-type air-conditioning units at lower-floors of MLABs (multi-level apartment buildings), using field measurements to monitor environmental conditions and condenser operation, revealed increases in the inlet air temperature at the condensers at the upper floors, which in turn increased the power and energy requirements for these units and decreased their cooling capacities. Results indicated that a decrease of up to 16,000 tons in cooling capacity and an increase of up to 67.2 MW in the national peak load demand might be reached for a 4 ℃ temperature differential for Kuwait conditions. It is recommended that the condensers be placed in the wind pathway to minimize the impact of heat rejection and stack effect and to optimize the operation of split-type air-conditioning units, and that other factors regarding installation setup and location are investigated.
基金financial support for this project from the National Natural Science Foundation of China(Nos.U1508212 and 51706097)National Science and Technology Major Project,China(No.2017-III-00110037)。
文摘Film cooling is an indispensable scheme in the design of highly-efficient cooling configurations to satisfy the thermal protection requirement of turbine hot section components.During the last few decades,vast efforts have been paid on the discrete-hole film cooling enhancement.In this paper,some of the recent literatures related to the passive strategies(such as shaped film cooling holes,upstream ramps,shallow trenches,mesh-fed slots)and the active strategies(such as the use of pulsation modulating device or plasma actuator)for film cooling enhancement are surveyed,with the aim at presenting an updated overview about the state of the art in advanced film cooling.In addition,some challenging issues are also outlined to motivate further investigations in such a broad topic.
基金The National Natural Science Foundation of China(Grant No.51476055,51821004)the National Basic Research Program of China(Grant No.2015CB251503)the Fundamental Research Funds for the Central Universities(Grant No.2018QN036)are gratefully acknowledged for supporting this research.
文摘The cooling performance of air-cooled condenser(ACC)is susceptible to adverse impacts of ambient winds.In this work,three kinds of lateral double-layered deflectors installed under the ACC platform are proposed to weaken the unfavorable effects of cross winds.Through CFD simulation methods,the main parameters of thermo-flow performances of a 2×660 MW direct dry cooling system are obtained,by which it can be concluded that the deflectors can effectively reduce the inlet air temperatures while enhance the mass flow rates of upwind fans due to the guiding effect,especially at high wind speeds,while the improvement of cooling capacity of ACCs in the 0°wind direction is weak.The inclined-vertical deflectors are superior to others in performance improvement of ACCs for all cases,which can reduce the turbine back pressure by 12.15%when the wind speed is 12 m/s,so they can be applied to the performance enhancement of ACCs under windy conditions in practical engineering.
文摘This article presents an innovative facade system designed to increase the thermal comfort inside an office room and to enhance the cooling capacity of the suspended cooling ceiling. A series of measurements is conducted in an existing office building with different facade systems (i.e., a combination of grazing and shading). An innovative facade system is devetoped based on this intensive set of measurements. The new system enhances the thermal comfort and cooling capacity of the suspended cooling ceiling. The main usage of the new system is the refurbishment and improvement of existing facade systems.
基金supported by the National Natural Science Foundation of China(No.51806231)the Strategic Priority Research Program of Chinese Academy of Sciences(Grant No.XDB35000000).
文摘As an important component of the stirling-type pulse tube cryocooler(SPTC),an efficient phase shifter can significantly improve the cooling capacity.Compared to the common phase shifter,the active warm displacer(AWD)has a wider phase adjustment range and therefore can obtain a better phase relationship easily.Based on a two-stage thermal-coupled SPTC operating in the 20 K range,this paper studied the influence of the swept volume ratio between the compressor and displacer.The research found that the swept volume ratio changes the cooling capacity and efficiency of the cryocooler mainly by changing the phase difference between the pressure wave and the volume flow at the cold end.It was found from the results of the simulation and experiments that there is an optimal displacement of the displacer(Xd)of 2.5 mm and an optimal phase angle of 15°to obtain the highest cooling efficiency while the displacement of the compressor is constant.The cooling capacity at 20 K is 1.3 W while the input electrical power of the second stage compressor is 202 W,which indicates an overall relative Carnot efficiency(rCOP)of 0.055 in terms of input electrical power.In addition,due to the reasonable setting of precooling temperature and capacity,the swept volume ratio and phase at the maximum cooling capacity and maximum efficiency are consistent in this study.The research improves the understanding of phase shifters and has guiding significance for the optimization of the SPTC working below 20 K.