A review is conducted about the application of the evaporative cooling technology in thermal power plants.Different case studies are considered,namely,evaporative air conditioners,evaporative cooling in direct air-coo...A review is conducted about the application of the evaporative cooling technology in thermal power plants.Different case studies are considered,namely,evaporative air conditioners,evaporative cooling in direct air-cooled systems,gas turbine inlet cooling,wet cooling towers,and hybrid cooling towers with a crosswind effect.Some effort is provided to describe the advantages related to direct evaporative cooling when it is applied in thermal power plants and illustrate the research gaps,which have not been filled yet.In particular,typical case studies are intentionally used to compare the cooling performances when direct evaporative cooling is implemented in different types of cooling towers,including the natural draft wet cooling tower(NDWCT)and the pre-cooled natural draft dry cooling tower(NDDCT).It is shown that the NDWCT provides the best cooling performance in terms of power station cooling,followed by the pre-cooled NDDCT,and the NDDCT;moreover,the evaporative pre-cooling is able to enhance the cooling performance of NDDCT.Besides,on a yearly basis,better NDDCT cooling performances can be obtained by means of a spray-based pre-cooling approach with respect to wet media pre-cooling.Therefore,the use of nozzle spray is suggested for improvement in the performance of indirect/direct air-cooling systems with controlled water consumption.展开更多
With the global warming and sea level rising, it is widely recognized that there is an increasing tendency of typhoon occurrence frequency and intensity. The defenses code against typhoon attacks for nuclear power pla...With the global warming and sea level rising, it is widely recognized that there is an increasing tendency of typhoon occurrence frequency and intensity. The defenses code against typhoon attacks for nuclear power plant should be calibrated because of the increasing threat of typhoon disaster and severe consequences. This paper discusses the probabilistic approach of definitions about "probable maximum typhoon" and "probable maximum storm surge" in nuclear safety regulations of China and has made some design code calibrations by use of a newly proposed Double Layer Nested Mtdti-objective Probability Model (DLNMPM).展开更多
The 300 MW steam turbine installed in Waigaoqiao Power Plant with combined HPIP cylinders of double casing structure is a product of the Shanghai Turbine Works utilizing licensed technology. It has a large heat storag...The 300 MW steam turbine installed in Waigaoqiao Power Plant with combined HPIP cylinders of double casing structure is a product of the Shanghai Turbine Works utilizing licensed technology. It has a large heat storage capacity and good thermal insulation, so the metal temperature of first stage of HP cylinder (FSMTI) may reach 400-450℃ after shut down and it takes 7-8 days to cool to 150℃ by natural cooling, Now with a forced cooling system the cooling time may be reduced to 40 hours, so that the turbine may be opened for repair work in about 5-6 days. The cooling system for #2 unit and test procedure are briefly described below.展开更多
The paper introduces thermal buoyancy effects to experimental investigation of wind tunnel simulation on direct air-cooled condenser for a large power plant. In order to get thermal flow field of air-cooled tower, PIV...The paper introduces thermal buoyancy effects to experimental investigation of wind tunnel simulation on direct air-cooled condenser for a large power plant. In order to get thermal flow field of air-cooled tower, PIV experiments are carried out and recirculation ratio of each condition is calculated. Results show that the thermal flow field of the cooling tower has great influence on the recirculation under the cooling tower. Ameliorating the thermal flow field of the cooling tower can reduce the recirculation under the cooling tower and improve the efficiency of air-cooled condenser also.展开更多
A theoretical analysis of the electricity production of a photovoltaic solar power plant of 22 MW for different sites in Senegal is presented. The study is carried out in two coastal regions (Dakar and Saint-Louis) an...A theoretical analysis of the electricity production of a photovoltaic solar power plant of 22 MW for different sites in Senegal is presented. The study is carried out in two coastal regions (Dakar and Saint-Louis) and two continental regions (Mbacké and Linguère). This study is done using the RET Screen clean energy project management software climate data. The amount of electricity exported to the grid is calculated for each site. The results show that the climatic conditions of the coastal and continental regions are different from November to June. From July to October, which corresponds to the rainy season in Senegal, the climatic conditions of the coastal and continental regions are similar. The results also show that although the efficiency of photovoltaic modules is better on the coast, electricity production varies little from one site to another. Climate conditions in Senegal therefore have no impact on electricity production.展开更多
In this study, we evaluate the ecological impact of effluent cooling water from the Ninh Thuan nuclear power plant II, using a two-dimensional hydraulic model to simulate thermal diffusion from the effluent outfall. S...In this study, we evaluate the ecological impact of effluent cooling water from the Ninh Thuan nuclear power plant II, using a two-dimensional hydraulic model to simulate thermal diffusion from the effluent outfall. Sites selected for this study were Ninh Thuan nuclear power plant and Vinh Hai seawater in four different scenarios. This paper utilized the relationship between surface water temperature and the water temperature at a depth of -15 m to calculate the water temperature at intake and outlet at a depth of -14 m. A combination between the results of interpolated and results of model showed that effluent cooling water from Ninh Thuan plant affected the largest incidence about 2450 m in the North, 880 m in the South and 960 m in the West. It can be considered as safe distance to not to affect the coral reefs ecosystem in the North and sea turtle conservation area in the South. This study was first in this region to have an integrated approach using two-dimensional model.展开更多
Zooplankton samples were collected using 505, 160 and 77 μm mesh nets around a power plant during four seasons in 2011. We measured total length of zooplankton and divided zooplankton into seven size classes in order...Zooplankton samples were collected using 505, 160 and 77 μm mesh nets around a power plant during four seasons in 2011. We measured total length of zooplankton and divided zooplankton into seven size classes in order to explore how zooplankton community size-structure might be altered by thermal discharge from power plant. The total length of zooplankton varied from 93.7 to 40 074.7 μm. The spatial distribution of mesozooplankton(200-2 000 μm) populations were rarely affected by thermal discharge, while macro-(2 000-10 000 μm)and megalo-zooplankton(>10 000 μm) had an obvious tendency to migrate away from the outfall of power plant.Thus, zooplankton community tended to become smaller and biodiversity reduced close to power plant.Moreover, we compared the zooplankton communities in three different mesh size nets. Species richness,abundance, evenness index and Shannon-Wiener diversity index of the 505 μm mesh size were significantly lower than those recorded from the 160 and 77 μm mesh size. Average zooplankton abundance was highest in the 77 μm mesh net((27 690.0±1 633.7) ind./m^3), followed by 160 μm mesh net((9 531.1±1 079.5) ind./m^3), and lowest in 505 μm mesh net((494.4±104.7) ind./m^3). The ANOSIM and SIMPER tests confirmed that these differences were mainly due to small zooplankton and early developmental stages of zooplankton. It is the first time to use the 77 μm mesh net to sample zooplankton in such an environment. The 77 μm mesh net had the overwhelming abundance of the copepod genus Oithona, as an order of magnitude greater than recorded for 160 μm mesh net and 100% loss through the 505 μm mesh net. These results indicate that the use of a small or even multiple sampling net is necessary to accurately quantify entire zooplankton community around coastal power plant.展开更多
This paper is concerned with water saving for water-loop cooling tower system in power plants. A newly developed water saving device of swirling flow is presented. The key point is that the new water saving device mak...This paper is concerned with water saving for water-loop cooling tower system in power plants. A newly developed water saving device of swirling flow is presented. The key point is that the new water saving device makes the steam swirl up along the device wall rather than engender laminar flow in a corrugated plate. The corrugated plate device can save approximately 10 percent of the total lost water. In contrast to the scale model of corrugated plate water saving device, experimental analyses have demonstrated that the new water saving device of swirling flow is more efficient, with a capacity of saving more than 20 percent of water.展开更多
基金supported by the Shandong Natural Science Foundation(Grant No.ZR2022ME008)the Shandong Provincial Science and Technology SMEs Innovation Capacity Improvement Project(2022TSGC2018)+3 种基金the Shenzhen Science and Technology Program(KCXFZ20201221173409026)The financial supports from the“Young Scholars Program of Shandong University”(YSPSDU,No.2018WLJH73)the Open Project of State Key Laboratory of Clean Energy Utilization,Zhejiang University(Program Number ZJUCEU2020011)the Shandong Natural Science Foundation(Grant No.ZR2021ME118)are gratefully acknowledged。
文摘A review is conducted about the application of the evaporative cooling technology in thermal power plants.Different case studies are considered,namely,evaporative air conditioners,evaporative cooling in direct air-cooled systems,gas turbine inlet cooling,wet cooling towers,and hybrid cooling towers with a crosswind effect.Some effort is provided to describe the advantages related to direct evaporative cooling when it is applied in thermal power plants and illustrate the research gaps,which have not been filled yet.In particular,typical case studies are intentionally used to compare the cooling performances when direct evaporative cooling is implemented in different types of cooling towers,including the natural draft wet cooling tower(NDWCT)and the pre-cooled natural draft dry cooling tower(NDDCT).It is shown that the NDWCT provides the best cooling performance in terms of power station cooling,followed by the pre-cooled NDDCT,and the NDDCT;moreover,the evaporative pre-cooling is able to enhance the cooling performance of NDDCT.Besides,on a yearly basis,better NDDCT cooling performances can be obtained by means of a spray-based pre-cooling approach with respect to wet media pre-cooling.Therefore,the use of nozzle spray is suggested for improvement in the performance of indirect/direct air-cooling systems with controlled water consumption.
基金supported by the Nationam Natural Science Foundation of China(Grant No.50679076)Office of State Flood Control and Drought Relief Headquarters of China(Grant No.20060120)
文摘With the global warming and sea level rising, it is widely recognized that there is an increasing tendency of typhoon occurrence frequency and intensity. The defenses code against typhoon attacks for nuclear power plant should be calibrated because of the increasing threat of typhoon disaster and severe consequences. This paper discusses the probabilistic approach of definitions about "probable maximum typhoon" and "probable maximum storm surge" in nuclear safety regulations of China and has made some design code calibrations by use of a newly proposed Double Layer Nested Mtdti-objective Probability Model (DLNMPM).
文摘The 300 MW steam turbine installed in Waigaoqiao Power Plant with combined HPIP cylinders of double casing structure is a product of the Shanghai Turbine Works utilizing licensed technology. It has a large heat storage capacity and good thermal insulation, so the metal temperature of first stage of HP cylinder (FSMTI) may reach 400-450℃ after shut down and it takes 7-8 days to cool to 150℃ by natural cooling, Now with a forced cooling system the cooling time may be reduced to 40 hours, so that the turbine may be opened for repair work in about 5-6 days. The cooling system for #2 unit and test procedure are briefly described below.
文摘The paper introduces thermal buoyancy effects to experimental investigation of wind tunnel simulation on direct air-cooled condenser for a large power plant. In order to get thermal flow field of air-cooled tower, PIV experiments are carried out and recirculation ratio of each condition is calculated. Results show that the thermal flow field of the cooling tower has great influence on the recirculation under the cooling tower. Ameliorating the thermal flow field of the cooling tower can reduce the recirculation under the cooling tower and improve the efficiency of air-cooled condenser also.
文摘A theoretical analysis of the electricity production of a photovoltaic solar power plant of 22 MW for different sites in Senegal is presented. The study is carried out in two coastal regions (Dakar and Saint-Louis) and two continental regions (Mbacké and Linguère). This study is done using the RET Screen clean energy project management software climate data. The amount of electricity exported to the grid is calculated for each site. The results show that the climatic conditions of the coastal and continental regions are different from November to June. From July to October, which corresponds to the rainy season in Senegal, the climatic conditions of the coastal and continental regions are similar. The results also show that although the efficiency of photovoltaic modules is better on the coast, electricity production varies little from one site to another. Climate conditions in Senegal therefore have no impact on electricity production.
文摘In this study, we evaluate the ecological impact of effluent cooling water from the Ninh Thuan nuclear power plant II, using a two-dimensional hydraulic model to simulate thermal diffusion from the effluent outfall. Sites selected for this study were Ninh Thuan nuclear power plant and Vinh Hai seawater in four different scenarios. This paper utilized the relationship between surface water temperature and the water temperature at a depth of -15 m to calculate the water temperature at intake and outlet at a depth of -14 m. A combination between the results of interpolated and results of model showed that effluent cooling water from Ninh Thuan plant affected the largest incidence about 2450 m in the North, 880 m in the South and 960 m in the West. It can be considered as safe distance to not to affect the coral reefs ecosystem in the North and sea turtle conservation area in the South. This study was first in this region to have an integrated approach using two-dimensional model.
基金The National Key Research and Development Program of China under contract No.2018YFD0900702the K.C.Wong Magna Fund in Ningbo University(SS)。
文摘Zooplankton samples were collected using 505, 160 and 77 μm mesh nets around a power plant during four seasons in 2011. We measured total length of zooplankton and divided zooplankton into seven size classes in order to explore how zooplankton community size-structure might be altered by thermal discharge from power plant. The total length of zooplankton varied from 93.7 to 40 074.7 μm. The spatial distribution of mesozooplankton(200-2 000 μm) populations were rarely affected by thermal discharge, while macro-(2 000-10 000 μm)and megalo-zooplankton(>10 000 μm) had an obvious tendency to migrate away from the outfall of power plant.Thus, zooplankton community tended to become smaller and biodiversity reduced close to power plant.Moreover, we compared the zooplankton communities in three different mesh size nets. Species richness,abundance, evenness index and Shannon-Wiener diversity index of the 505 μm mesh size were significantly lower than those recorded from the 160 and 77 μm mesh size. Average zooplankton abundance was highest in the 77 μm mesh net((27 690.0±1 633.7) ind./m^3), followed by 160 μm mesh net((9 531.1±1 079.5) ind./m^3), and lowest in 505 μm mesh net((494.4±104.7) ind./m^3). The ANOSIM and SIMPER tests confirmed that these differences were mainly due to small zooplankton and early developmental stages of zooplankton. It is the first time to use the 77 μm mesh net to sample zooplankton in such an environment. The 77 μm mesh net had the overwhelming abundance of the copepod genus Oithona, as an order of magnitude greater than recorded for 160 μm mesh net and 100% loss through the 505 μm mesh net. These results indicate that the use of a small or even multiple sampling net is necessary to accurately quantify entire zooplankton community around coastal power plant.
文摘This paper is concerned with water saving for water-loop cooling tower system in power plants. A newly developed water saving device of swirling flow is presented. The key point is that the new water saving device makes the steam swirl up along the device wall rather than engender laminar flow in a corrugated plate. The corrugated plate device can save approximately 10 percent of the total lost water. In contrast to the scale model of corrugated plate water saving device, experimental analyses have demonstrated that the new water saving device of swirling flow is more efficient, with a capacity of saving more than 20 percent of water.