期刊文献+
共找到20篇文章
< 1 >
每页显示 20 50 100
Experimental Study on Mechanical Properties of Q345 Steel after High Temperature Cooling
1
作者 Fei Zhu Yu Zhang Chuntao Zhang 《World Journal of Engineering and Technology》 2020年第3期257-265,共9页
Because of its advantages of light weight, high strength and convenient construction, steel structure has gradually become the first choice for large-span and high-rise structures. The use of high strength steel in bu... Because of its advantages of light weight, high strength and convenient construction, steel structure has gradually become the first choice for large-span and high-rise structures. The use of high strength steel in building engineering can reduce the section size of components and the weight of the structure, thus increasing the building area. But steel is not fire-resistant, when the temperature reaches 600<span style="white-space:nowrap;">°</span>C, steel loses most of the stiffness and strength. Therefore, it is of great significance to study the fire resistance of steel structures, and the mechanical properties of steel structures at high temperature are the foundation of the fire resistance research. The mechanical properties of steel after high temperature are the basis for the safety assessment of steel structure after fire. Therefore, this paper studies the mechanical properties of Q345 steel after high temperature cooling. 展开更多
关键词 Q345 Steel High temperature Natural cooling Mechanical Properties
下载PDF
Exact results on cavity cooling in a system of a two-level atom and a cavity field 被引量:2
2
作者 张玉青 谭磊 +1 位作者 朱中华 刘利伟 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第3期263-268,共6页
Using the algebraic dynamical method, this paper investigates the laser cooling of a moving two-level atom coupled to a cavity field. Analytical solutions of optical forces and the cooling temperatures are obtained. C... Using the algebraic dynamical method, this paper investigates the laser cooling of a moving two-level atom coupled to a cavity field. Analytical solutions of optical forces and the cooling temperatures are obtained. Considering Rb atoms as an example, it finds that the numerical results are relevant to the recent experimental laser cooling investigations. 展开更多
关键词 laser cooling algebraic dynamical method optical forces cooling temperatures
下载PDF
Study on temperature field and settlement of thawing soil under static and dynamic loading
3
作者 LiYun Peng JianKun Liu 《Research in Cold and Arid Regions》 CSCD 2013年第5期659-666,共8页
A series of tests were conducted to analyze temperature field distribution and thawing settlement of a thawing soil under static and dynamic loading at various cooling and thawing temperatures. The results demonstrate... A series of tests were conducted to analyze temperature field distribution and thawing settlement of a thawing soil under static and dynamic loading at various cooling and thawing temperatures. The results demonstrate: (1) the temperature field distribution of the thawing soil was not significantly influenced by the loading form under the tested loading conditions; similar results were obtained for samples at different dynamic loading frequencies and different dynamic loading ampli- tudes, which verified the independence of loading form and temperature field; (2) changed temperature field distributions were found in thawing soil with different cooling and thawing temperatures, and the cooling and thawing temperature of the samples were the main factors affecting their temperature distributions; (3) under the tested conditions, thawing set- tlements were little influenced by the thawing temperature and the dynamic loading frequency; and (4) a linear relation- ship existed between the thawing settlement and the cooling temperature, and a logarithmic function could be used to describe the relationship between the thawing settlement and the loading amplitude. 展开更多
关键词 temperature field thawing settlement thawing soil dynamic loading cooling temperature thawing temperature
下载PDF
Experimental Study of Integration and Polyblends Performance for Improved Mixing-Extruding Machine 被引量:1
4
作者 汪传生 张德伟 李利 《Journal of Donghua University(English Edition)》 EI CAS 2014年第4期453-457,共5页
One improved mixing-extruding machine was introduced as the second-generation product of the mixing-molding integrated technology. In the extruding system,the conventional single screw extruder was substituted by a sp... One improved mixing-extruding machine was introduced as the second-generation product of the mixing-molding integrated technology. In the extruding system,the conventional single screw extruder was substituted by a special conical twin-screw extruder,resulting in stronger feeding ability,more stable extrusion pressure,and better quality of products. The integrated mathematical model of mixing-extruding process was also established by theoretical derivation and optimization according to the experimental results.Then its accuracy was verified by the influences of the pressure of floating weight and the cooling water temperature of extruder on the mixing-extruding integrated process. The results showed that the changes of both parameters could give rise to the fluctuation of the temperature and apparent viscosity of polyblends, thus further influencing the screw rotation speed. 展开更多
关键词 mixing-extruding machine conical twin-screw mathematical model pressure of floating weight cooling temperature of extruder
下载PDF
Effect of Cooling Start Temperature on Microstructure and Mechanical Properties of X80 High Deformability Pipeline Steel 被引量:7
5
作者 ZHENG Xiao-fei KANG Yong-lin +2 位作者 MENG De-liang AN Shou-yong XIA Dian-xiu 《Journal of Iron and Steel Research(International)》 SCIE EI CAS CSCD 2011年第10期42-46,71,共6页
The effect of cooling (laminar cooling) start temperature on the phase constitution was analyzed by quanti- tative metallography. The martensite/austenite (M/A) island distribution was fixed by colour metallograph... The effect of cooling (laminar cooling) start temperature on the phase constitution was analyzed by quanti- tative metallography. The martensite/austenite (M/A) island distribution was fixed by colour metallography. The strength and uniform elongation of the steels were tested with quasi-static tensile testing machine. The in-coordinate deformation of the soft and hard phases was analyzed using FEM. The results indicate that when the cooling start temperature is 690 ℃, the mechanical properties are the best, meeting the requirements of X80 high deformability pipeline steel. 展开更多
关键词 high deformability pipeline steel cooling start temperature carbon diffusion in-coordinate deformationsM/A island
原文传递
Deterioration Mechanisms of Sulfate Attack on Concrete under Alternate Action 被引量:8
6
作者 高润东 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2010年第2期355-359,共5页
By micro- and macro-observations, the deterioration mechanisms of concrete under alternate action between repeated sub-high temperature/cooling by water and sodium sulfate solution attack (TW-SA) were studied; meanw... By micro- and macro-observations, the deterioration mechanisms of concrete under alternate action between repeated sub-high temperature/cooling by water and sodium sulfate solution attack (TW-SA) were studied; meanwhile, the single sodium sulfate solution attack (SA) was also done as comparison. Micro-observations included the analysis of attack products by thermal analysis method and the determination of sulfate-ion content from surface to interior by chemical titrating method (modified barium sulfate gravimetric method). Macro-observations mainly included the mechanical behaviors such as compressive strength, splitting strength. The experimental results indicate, in both cases, the main attack product is ettringite, only in the first layer of case SA some gypsum is checked; in case SA, the sulfate ions mainly concentrate in the surface layer, so the attack is relatively mild; but in case TW-SA, the repeated sub-high temperature/cooling by water promotes the sulfate ions diffusing inwards, which leads to obvious strength degradation. 展开更多
关键词 CONCRETE SULFATE repeated sub-high temperature/cooling by water attack product sulfate-ion content strength
下载PDF
Novel Matching Strategy for the Coupling of Heat Flux in Furnace Side and CO_(2)Temperature in Tube Side to Control the Cooling Wall Temperatures 被引量:2
7
作者 LIU Chao MIAO Zheng +2 位作者 XU Jinliang XU Zeyu LI Mingjia 《Journal of Thermal Science》 SCIE EI CAS CSCD 2021年第4期1251-1267,共17页
Required by the supercritical carbon dioxide(s CO_(2))coal-fired power cycle,s CO_(2)entering a boiler has a high temperature and can cause overheating of tubes.To eliminate the pressure drop penalty effect,the s CO_(... Required by the supercritical carbon dioxide(s CO_(2))coal-fired power cycle,s CO_(2)entering a boiler has a high temperature and can cause overheating of tubes.To eliminate the pressure drop penalty effect,the s CO_(2)boiler consists of several modules,each having different heat flux received from the furnace side(q)and different CO_(2)temperature in the cooling wall tube(T_f).We aim to search for the best matching strategy coupling furnace side and tube side to obtain the lowest temperature of tubes.By theoretically analyzing the wall temperature influenced by q,T_f and a comprehensive thermal resistance C,two matching methods are introduced:the heat flux-temperature matching(HTM)which matches higher q with lower T_f,and the heat flux-heat flux matching(HHM)that matches higher q with higher allowable-heat-flux at the temperature limit of tubes.HTM is a conventional method but HHM is newly proposed here.We show that,if C is identical for different modules,the two methods coincide;otherwise,HHM is recommended.For a s CO_(2)boiler driving 1000 MWe power plant,smaller cooling wall temperatures are obtained by HHM than HTM.Based on HHM,the mid-partition wall,heat transfer enhancement,and downward flow are comprehensively used,decreasing the wall temperature significantly. 展开更多
关键词 sCO_(2)power cycle sCO_(2)modular boiler cooling wall temperature allowable heat flux matching strategy
原文传递
The Effect of Warm Water and Its Weak Negative Feedback on the Rapid Intensification of Typhoon Hato(2017) 被引量:3
8
作者 霍子墨 端义宏 刘欣 《Journal of Tropical Meteorology》 SCIE 2020年第4期402-416,共15页
Typhoon Hato (2017) went through a rapid intensification (RI) process before making landfall in Zhuhai,Guangdong Province, as the observational data shows. Within 24 hours, its minimum sea level pressure deepened by35... Typhoon Hato (2017) went through a rapid intensification (RI) process before making landfall in Zhuhai,Guangdong Province, as the observational data shows. Within 24 hours, its minimum sea level pressure deepened by35hPa and its maximum sustained wind speed increased by 20m s-1. According to satellite observations, Hato encountered a large area of warm water and two warm core rings before the RI process, and the average sea surface temperature cooling (SSTC) induced by Hato was only around 0.73℃. Air-sea coupled simulations were implemented to investigate the specific impact of the warm water on its RI process. The results showed that the warm water played an important role by facilitating the RI process by around 20%. Sea surface temperature budget analysis showed that the SSTC induced by mixing mechanism was not obvious due to the warm water. Besides, the cold advection hardly caused any SSTC, either. Therefore, the SSTC induced by Hato was much weaker compared with that in general cases. The negative feedback between ocean and Hato was restrained and abundant heat and moisture were sufficiently supplied to Hato. The warm water helped heat flux increase by around 20%, too. Therefore, the warm water influenced the structure and the intensity of Hato. Although there might be other factors that also participated in the RI process, this study focused on air-sea interaction in tropical cyclone forecast and discussed the impact of warm water on the intensity and structure of a tropical cyclone. 展开更多
关键词 Typhoon Hato rapid intensification warm water air-sea coupled model sea surface temperature cooling
下载PDF
Monte Carlo studies on the burnup measurement for the high temperature gas cooling reactor
9
作者 闫威华 张立国 +2 位作者 张嫣 张钊 肖志刚 《Chinese Physics C》 SCIE CAS CSCD 2013年第11期58-62,共5页
Online fuel pebble burnup measurement in a future high temperature gas cooling reactor is proposed for implementation through a high purity germanimn (HPGe) gamma spectrometer. By using KORIGEN software and MCNP Mon... Online fuel pebble burnup measurement in a future high temperature gas cooling reactor is proposed for implementation through a high purity germanimn (HPGe) gamma spectrometer. By using KORIGEN software and MCNP Monte Carlo simulations, the single pebble gamma radiations to be recorded in the detector are simulated under different, irradiation histories. A specially developed algorithm is applied to analyze the generated spectra to reconstruct the gamma activity of the ~arCs monitoring nuclide. It is demonstrated that by taking into account the intense interfering peaks, the 137Cs activity in the spent pebbles can be derived with a standard deviation of 3.0% (l(r). The results support the feasibility of utilizing the HPGe spectrometry in the online determination of the pebble burimp in future modular pebble bed reactors. 展开更多
关键词 high temperature gas cooling reactor BURNUP T activity Monte Carlo
原文传递
Optimal Thermal Insulation Thickness in Isolated Air-Conditioned Buildings and Economic Analysis
10
作者 Mousa M. Mohamed 《Journal of Electronics Cooling and Thermal Control》 2020年第2期23-45,共23页
The removal building heat load and electrical power consumption by air conditioning system are proportional to the outside conditions and solar radiation intensity. Building construction materials has substantial effe... The removal building heat load and electrical power consumption by air conditioning system are proportional to the outside conditions and solar radiation intensity. Building construction materials has substantial effects on the transmission heat through outer walls, ceiling and glazing windows. Good thermal isolation for buildings is important to reduce the transmitted heat and consumed power. The buildings models are constructed from common materials with 0 - 16 cm of thermal insulation thickness in the outer walls and ceilings, and double-layers glazing windows. The building heat loads were calculated for two types of walls and ceiling with and without thermal insulation. The cooling load temperature difference method, <em>CLTD</em>, was used to estimate the building heat load during a 24-hour each day throughout spring, summer, autumn and winter seasons. The annual cooling degree-day, <em>CDD</em> was used to estimate the optimal thermal insulation thickness and payback period with including the solar radiation effect on the outer walls surfaces. The average saved energy percentage in summer, spring, autumn and winter are 35.5%, 32.8%, 33.2% and 30.7% respectively, and average yearly saved energy is about of 33.5%. The optimal thermal insulation thickness was obtained between 7 - 12 cm and payback period of 20 - 30 month for some Egyptian Cities according to the Latitude and annual degree-days. 展开更多
关键词 Building Heat Load cooling Load temperature Difference Energy Saving Power Consumption Annual cooling Degree-Day Optimal Thermal Insulation Thickness Payback Period
下载PDF
Characteristics of Bi-2223 HTS Tapes Under Short-Circuit Current Impacts in Hybrid Energy Transmission Pipelines
11
作者 Yuguang Sun Chao Yin +2 位作者 Weizhen Li Xinyang Li Xiaohua Jiang 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2024年第2期736-745,共10页
A hybrid energy transmission pipeline is proposed with the aim of long-distance cooperative transmission of electricity and chemical fuels, which is composed of an inner high-temperature superconducting (HTS) power ca... A hybrid energy transmission pipeline is proposed with the aim of long-distance cooperative transmission of electricity and chemical fuels, which is composed of an inner high-temperature superconducting (HTS) power cable and outer liquefied natural gas (LNG) pipeline. The flowing LNG could maintain the operating temperature of the inner HTS power cable within the range of 85 K-90 K, thus the Bi-2223 superconductors in the HTS power cable produce little Joule loss with the transmission current below the critical current. Owing to the advantages of high power density, low transmission losses and economical manufacturing costs, the hybrid energy transmission pipeline is expected to be widely utilized in the near future. In order to ensure the safety of the HTS power cable and explosive LNG in case of short-circuit faults, this paper tests and analyzes the characteristics of Bi-2223 HTS tapes of the Type HT-CA, Type HT-SS and Type H models under short-circuit current impacts at the LNG cooling temperature (85 K-90 K). An experimental platform is designed and established for the ampacity tests of HTS tapes above LN2 cooling temperature (77 K). The AC over-current impact tests at 85 K-90 K are carried out on each sample of Bi-2223 tapes respectively, and the experimental results are analyzed and compared to evaluate their performances under different operating conditions. The results indicate that the Type HT-CA tape can withstand 50 Hz short-circuit current impact with the amplitude of 1108 A (10 times of critical current Ic ) for 100 ms at 90 K, and its resistance is the smallest of the three tested samples under similar current impacts. Therefore, the Type HT-CA Bi-2223 tape is the optimal superconductor of the HTS power cable in the hybrid energy transmission pipeline. 展开更多
关键词 Bi-2223 high-temperature superconducting(HTS)tape critical current hybrid energy transmission pipeline liquefied natural gas(LNG)cooling temperature short-circuit current impact characteristics
原文传递
The Impact of Storm-Induced SST Cooling on Storm Size and Destructiveness: Results from Atmosphere-Ocean Coupled Simulations 被引量:1
12
作者 Tao GUO Yuan SUN +1 位作者 Lei LIU Zhong ZHONG 《Journal of Meteorological Research》 SCIE CSCD 2020年第5期1068-1081,共14页
In this study, both an atmospheric model [Weather Research and Forecasting(WRF) model] and an atmosphere(WRF)–ocean(Princeton Ocean Model;POM) coupled model are used to simulate the tropical cyclone(TC) Kaemi(2006). ... In this study, both an atmospheric model [Weather Research and Forecasting(WRF) model] and an atmosphere(WRF)–ocean(Princeton Ocean Model;POM) coupled model are used to simulate the tropical cyclone(TC) Kaemi(2006). By comparing the simulation results of the models, effects of oceanic elements, especially the TC-induced sea surface temperature(SST) cooling, on the simulated TC size and destructiveness are identified and analyzed. The results show that there are no notable differences in the simulated TC track and its intensity between the uncoupled and coupled experiments;however, there are large differences in the TC size(i.e., the radius of gale-force wind)between the two experiments, and it is the TC-induced SST cooling that decreases the TC size. The SST cooling contributes to the decrease of air–sea moisture difference(ASMD) outside the TC eyewall, which subsequently leads to the decreases in surface enthalpy flux(SEF), radial sea-level pressure gradient, absolute vorticity advection, and wind speed outside the TC eyewall. As a result, the TC size and size-dependent TC destructive potential all decrease remarkably. 展开更多
关键词 tropical cyclone(TC)size DESTRUCTIVENESS sea surface temperature(SST)cooling
原文传递
Self-acting Afterheat Removal in High Temperature Gas Cooled Reactors
13
作者 Kugeler K.,Phlippen P.W.,Nieβen H.F. Institute for Safety Research and Reactor Technology, Research Center Jülich,Jülich D 52428, Germany 《Tsinghua Science and Technology》 SCIE EI CAS 1998年第4期1167-1178,共12页
Much more nuclear energy capacity is needed than currently installed to meet the demand of energy and the requirement on environment protection in the next decades. More stringent nuclear safety standards have to be e... Much more nuclear energy capacity is needed than currently installed to meet the demand of energy and the requirement on environment protection in the next decades. More stringent nuclear safety standards have to be established for future nuclear power plants.The philosophy of a catastrophe free nuclear technology is presented in this paper. The issue of afterheat removal of high temperature gas cooled reactors is handled.It is a striking inherent safety feature of the modular high temperature gas cooled reactor design that the afterheat removal takes place without any active core cooling systems. 展开更多
关键词 nuclear safety afterheat high temperature gas cooled reactors
原文传递
Correlation of Microstructure Feature with Impact Fracture Behavior in a TMCP Processed High Strength Low Alloy Construction Steel 被引量:3
14
作者 Wen-Ting Zhu Jun-Jun Cui +2 位作者 Zhen-Ye Chen Yang Zhao Li-Qing Chen 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2022年第4期527-536,共10页
The present article aims at elucidating the effect of thermo-mechanical controlled processing(TMCP), especially the finish cooling temperature, on microstructure and mechanical properties of high strength low alloy st... The present article aims at elucidating the effect of thermo-mechanical controlled processing(TMCP), especially the finish cooling temperature, on microstructure and mechanical properties of high strength low alloy steels for developing superior low temperature toughness construction steel. The microstructural features were characterized by scanning electron microscope equipped with electron backscatter diffraction, and the mechanical behaviors in terms of tensile properties and impact toughness were analyzed in correlation with microstructural evolution. The results showed that the lower finish cooling temperature could lead to a considerable increase in impact toughness for this steel. A mixed microstructure was obtained by TMCP at lower finish cooling temperature, which contained much fine lath-like bainite with dot-shaped M/A constituent and less granular bainite and bainite ferrite. In this case, this steel possesses yield and ultimate tensile strengths of ~ 885 MPa and 1089 MPa, respectively, and a total elongation of ~ 15.3%, while it has a lower yield ratio of ~ 0.81. The superior impact toughness of ~ 89 J at-20 °C was obtained, and this was resulted from the multi-phase microstructure including grain refinement, preferred grain boundaries misorientation, fine lath-like bainite with dot-shaped M/A constituent. 展开更多
关键词 High strength low alloy steel Thermo-mechanical controlled processing(TMCP) Finish cooling temperature Microstructure Mechanical properties Impact toughness
原文传递
Effect of Thermomechanical Controlled Processing on Mechanical Properties of 490 MPa Grade Low Carbon Cold Heading Steel 被引量:1
15
作者 LI Zhuang 《Journal of Iron and Steel Research(International)》 SCIE EI CAS CSCD 2009年第3期43-48,共6页
Thermomechanical controlled processing (TMCP) of low carbon cold heading steel in different austenite conditions were conducted by a laboratory hot rolling mill. Effect of various processing parameters on the mechan... Thermomechanical controlled processing (TMCP) of low carbon cold heading steel in different austenite conditions were conducted by a laboratory hot rolling mill. Effect of various processing parameters on the mechanical properties of the steel was investigated. The results showed that the mechanical properties of the low carbon cold heading steel could be significantly improved by TMCP without heat treatment. The improvement of mechanical properties can be attributed mainly to the ferrite grain refinement due to low temperature rolling. In the experiments the better ultimate tensile strength and ductility are obtained by lowering finishing cooling temperature within the temperature range from 650 ℃ to 550 ℃ since the interlamellar space in pearlite colonies become smaller. Good mechanical properties can be obtained in a proper austenite condition and thermomechanical processing parameter. The ferrite morphology has a more pronounced effect on the mechanical behavior than refinement of the microstructure. It is possible to realize the replacement of medium-carbon by low-carbon for 490 MPa grade cold heading steel with TMCP. 展开更多
关键词 thermomechanical controlled processing TMCP low carbon cold heading steel low temperature rolling finishing cooling temperature
原文传递
Effects of Technological Parameters on Microstructures and Properties of Low Cost Hot Rolled Dual-Phase Steel on CSP Line 被引量:1
16
作者 DONG Rui-feng 1,2,LI De-gang 1,2,YAN Bo 2,WANG Guo-dong 1 (1.The State Key Lab of Rolling and Automation,Northeastern University,Shenyang 110004,China 2.Baotou Iron and Steel (Group) Co Ltd,Compact Strip Production Plant,Baotou 014010,China) 《Journal of Iron and Steel Research(International)》 SCIE EI CAS CSCD 2011年第S1期615-620,共6页
The effects of technological parameters on microstructures and properties of low cost hot rolled dual-phase steel was researched by design different finish rolling temperature,mid cooling temperature between laminar c... The effects of technological parameters on microstructures and properties of low cost hot rolled dual-phase steel was researched by design different finish rolling temperature,mid cooling temperature between laminar cooling and UFC (ultra fast cooling) and stable UFC rate on the same gauge strips with the same chemistry composition during the manufacture process.It is the key for controlling coil temperature to control finish rolling temperature and mid cooling temperature between laminar cooling and UFC that based on stable UFC rate precondition.The lower finish rolling temperature,with mid cooling temperature between laminar cooling and UFC,the better to form martensite is.The foundation of developing the similar productions on the similar product line was supplied.It is good to technological advancement of developing high affixation value production as hot rolled DP steel,TRIP steel etc.in CSP line. 展开更多
关键词 finish rolling temperature mid cooling temperature between laminar cooling and UFC hot rolled dual-phase steel microstructures and properties
原文传递
Research on Alloying Design and Process Control for X100 Hot-Rolled Strips
17
作者 JIA Shu-jun 1,LIU Qing-you 1,PENG Ling-li 1,QU Peng 2 (1.China Iron and Steel Research Institute Group,Beijing 100081,China 2.Benxi Steel Group Corporation,Benxi 100083,Liaoning,China) 《Journal of Iron and Steel Research(International)》 SCIE EI CAS CSCD 2011年第S1期675-680,共6页
The influence of alloying design,controlled rolling technology and cooling system of X100 hot-rolled strips on microstructure and micro-hardness has been discussed in detail in this paper.The results show that optimal... The influence of alloying design,controlled rolling technology and cooling system of X100 hot-rolled strips on microstructure and micro-hardness has been discussed in detail in this paper.The results show that optimal chemical composition range of X100 hot-rolled strips is obtained on the basis of X80 by increasing contents of C,Mn,Ni and Mo of X80.The granular bainite microstructure could be refined and the volume fraction and size of M-A islands could be controlled in a reasonable range by reasonably regulating cooling rate and coiling temperature of X100 pipeline steel,which ensure high strength and toughness of X100 pipeline steel. 展开更多
关键词 alloying design DEFORMATION cooling rate final cooling temperature granular bainite
原文传递
Heat Transfer During Quenching by Plate Roller Quenching Machine 被引量:5
18
作者 WANG Chao WANG Zhao-dong +3 位作者 YUAN Guo WANG Dao-yuan WU Jun-ping WANG Guo-dong 《Journal of Iron and Steel Research(International)》 SCIE EI CAS CSCD 2013年第5期1-5,共5页
For plate quenching on a roller quenching machine, heat transfer process is investigated. According to the practical online experiment of plate center temperature, average heat transfer coefficient under different con... For plate quenching on a roller quenching machine, heat transfer process is investigated. According to the practical online experiment of plate center temperature, average heat transfer coefficient under different conditions and temperature fields are analyzed by numerical simulation. The results show that, at the water temperature of 15 ℃, the instantaneous maximum quenching cooling rate is 17.6 ℃/s for the plate of 50 mm in thickness in roller quenching process. In the temperature range of 400-850 ℃, the maximum is 12.1 ℃/s. With the plate surface temperature decreasing, surface heat transfer coefficient increases at first, and reaches the maximum value of about 15 000 W/(m^2·K), and then decreases. The calculated heat transfer coefficients are applied to analyze plate temperature field of different thicknesses, and the difference between the calculated and measured temperature is less than 5%. 展开更多
关键词 plate roller quenching machine heat transfer coefficient water temperature cooling rate
原文传递
Two Phase Flow Stability in the HTR-10 Steam Generator
19
作者 居怀明 左开芬 +1 位作者 刘志勇 徐元辉 《Tsinghua Science and Technology》 SCIE EI CAS 2001年第1期75-79,共5页
A 10MW High Temperature Gas Cooled Reactor (HTR-10) designed by the Institute of Nuclear Energy Technology (INET) is now being constructed. The steam generator (SG) in the HTR-10 is one of the most important component... A 10MW High Temperature Gas Cooled Reactor (HTR-10) designed by the Institute of Nuclear Energy Technology (INET) is now being constructed. The steam generator (SG) in the HTR-10 is one of the most important components for reactor safety. The thermal-hydraulic performance of the SG was investigated. A full scale HTR-10 Steam Generator Two Tube Engineering Model Test Facility (SGTM-10) was installed and tested at INET. This paper describes the SGTM-10 thermal hydraulic experimental system in detail. The SGTM-10 simulates the actual thermal and structural parameters of the HTR-10. The SGTM-10 includes three separated loops: the primary helium loop, the secondary water loop, and the tertiary cooling water loop. Two parallel tubes are arranged in the test assembly. The main experimental equipment is shown in the paper. Expermental results are given illustrating the effects of the outlet pressures, the heating power, and the inlet subcooling. 展开更多
关键词 high temperature gas cooled reactor once-through steam generator helical tube steam generator two phase flow stability
原文传递
Mass production of magnetocaloric LaFeMnSiB alloys with hydrogenation
20
作者 Tao Zhang Cheng-yong Wang +2 位作者 Lugee Li Yong Zhang Cui-lan Liu 《Journal of Iron and Steel Research(International)》 SCIE EI CAS CSCD 2017年第4期462-468,共7页
LaFe_(11.39)Mn_(0.35)Si_(1.26)B_(0.1)Hxalloys were prepared by hydrogenation.Samples were annealed at 1343Kfor30-90 hto form the NaZn13 phase.La-rich andα-Fe secondary phases were also detected.Saturated hydr... LaFe_(11.39)Mn_(0.35)Si_(1.26)B_(0.1)Hxalloys were prepared by hydrogenation.Samples were annealed at 1343Kfor30-90 hto form the NaZn13 phase.La-rich andα-Fe secondary phases were also detected.Saturated hydrogenation at 553 Kand 0.15 MPa of H_2 pressure for 5hwas employed to improve the Curie temperature of the alloys to 279 K.The maximum magnetic entropy change,relative cooling power,and adiabatic temperature change of LaFe_(11.39)Mn_(0.35)Si_(1.26)B_(0.1)H_x annealed at 1343 Kfor 90hafter hydrogen absorption are 6.38J/(kg·K)(magnetic changesμ0ΔH =1.65T),100.1J/kg(μ0ΔH =1.65T),and 2.2 K(μ0ΔH =1.48T),respectively.Although the maximum magnetic entropy change of the LaFe_(11.39)Mn_(0.35)Si_(1.26)B_(0.1)H_x alloys is lower than those of similar alloys with high purity raw materials,the relative cooling power is nearly the same.The effect of impurities of the raw materials used was also discussed.It is assumed that the impurity of 0.2wt.% Al is responsible for the reduced entropy change of the resulted alloys.The LaFe_(11.39)Mn_(0.35)Si_(1.26)B_(0.1)H_x alloys prepared by this method could be a low cost alternative material for room temperature magnetic cooling applications. 展开更多
关键词 Magnetocaloric effect Annealing Hydrogenation Adiabatic temperature change Relative cooling power Maximum magnetic entropy change
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部